7590-01-P UNITED STATES NUCLEAR REGULATORY COMMISSION COMMONWEALTH EDISON COMPANY DOCKET NO. STN 50-454 l
BYRON STATION. UNIT NO.1 ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT The U.S. Nuclear Regulatory Commission (the Commission ) is considering issuance of an exemption from certain requirements of its regulations for Facility Operating License No.
i NPF-37, issued to Commonwealth Edison Company (Comed, the licensee), for operation of Byron Station, Unit 1, located in Ogle County, Illinois.
ENVIRONMENTAL ASSESSMENT Identification of Pronosed Action:
The proposed action would exempt Comed from the requirements of 10 CFR 70.24, which require a monitoring system that will energize clear audible alarms if accidental criticality occurs in each area in which special nuclear material is handled, used, or stored. The proposed action would also exempt the licensee from the requirements to maintain emergency procedures for each area in which this licensed special nuclear material is handled, used, or stored to ensure that all personnel withdraw to an area of safety upon the sounding of the alarm, to familiarize personnel with the evacuation plan, and to designate responsible individuals for determining the cause of the alarm, and to place radiation survey instruments in accessible location for use in such an emergency.
The proposed action is in accordance with the licensee's application for exemption dated October 16,1997.
9903180261 990303 PDR ADOCK 05000454 P
PDR-x
=:
. 2 The Need for the Prooosed Action:
The purpose of 10 CFR 70.24 is to ensure that if a criticality were to occur during the handling of special nuclear material, pe"sonnel would be alerted to that fact and would take appropriate action. At a commercial nuclear power plant, the inadvertent criticality with which 10 CFR 70.24 is concemed could occur during fuel handing operations. The special nuclear material that could be assembled into a critica! mass at a commercial nuclear power plant is in the form of nuclear fuel; the quantity of other forms of special nuclear material that is stored on site in a given location is small enough to preclude achieving a critical mass. Because the fuel is not enrichad beyond 5.0 weight percent Uranium-235 and because commercial nuclear plant licensees have procedures and design features that prevent inadvertent criticality, the staff has 1
determined that it is unlikely that an inadvertent criticality could occur due to the handling of special nuclear material at a commercial power reactor. The requirements of 10 CFR 70.24, therefore, are not necessary to ensure the safety of personnel during the handling of special nuclear materials at commercial power reactors.
Environmentalimoacts of the Prooosed Action:
The Commission has completed its evaluation of the proposed actions and concludes that there is no significant environmental impact to Byron. Inadvertent or accidental criticality will be precluded through compliance with the Byron Station Technical Specifications (TSs), the design of the fuel storage racks providing geometric spacing of fuel assemblies in their storage locations, and administrative controls imposed on fuel handling procedures. TSs requirements specify reactivity limits for the fuel storage racks and minimum spacing between tho fuel assemblies in the storage racks.
. - - ~ -.. _.... - - -. -...
. ~ Appendix A of 10 CFR Part 50, " General Design Criteria for Nuclear Power Plants,"
l (GDC) Criterion 62, requires that criticality in the fuel storage and handling system shall be prevented by physical systems or processes, preferably by use of geometrically-safe configurations. This is met at Byron Station, as identified in the Updated Final Safety Analysis Report (UFSAR). Byron Station UFSAR Section g.1.1.1, New Fuel Storage - Design Basis, states that, "...the new fuel storage racks are designed such that the effectiva multiplication factor does not exceed 0.95 with fuel of a maximum enrichment of 5.00 wt% u-235 in place,'
assuming the stored assemblies are completely submerged in unborated water at a conservative water temperature and with no credit for neutron poison in the fuel assembly."
NUREG-0876, " Safety Evaluation Report Related to the Operation of ByroriStation, Units 1 and 2," dated February 1982, determined that the design of the Byron new fuel storage racks -
satisfied the requirements of GDC 62.
The proposed exemption would not result in any significant radiological impacts. The
. proposed exemption would not affect radiological plant effluents nor cause any significant occupational exposures since the TSs, design controls (including geometric spacing of fuel assembly storage spaces), and administrative controls preclude inadvertent criticality. The j
amount of radioactive waste would not be changed by the proposed exemption.
The proposed exemption does not result in any significant nonradiological environmental impacts. The proposed exemption involves features located entirely within the restricted area as defined in 10 CFR Part 20. It does not affect non-radiological plant effluents and has no other environmental impact. Accordingly, the Commission concludes that there are no significant non-radiological environmental impacts associated the proposed action.
...- ~
o.
.4 a
Alt,ematives to the Proposed Action:
Since the Commission has concluded that there is no measurable environmental impact associated with the proposed action, any attematives with equal or greater environmental
- impact need not be evaluated. As an attemative to the proposed exemption, the staff -
considered denial of the requested exemption. Denial of the request would result in no change in current environmental impacts. The environmentalimpacts of the proposed action and the attemative are similar.
A'temative Use of Resourggg:
The action does not involve the use of any resources not previously considered in the
" Final Environmental Statement Related to the Operation of Byron Station, Units 1 and 2" dated April 1982.
Aaencies and Persons Consulted:
In accordance with its stated policy, on February 24,1999, the staff consulted with the Illinois State official, Mr. Frarik Niziolek, Head, Reactor Sa' ety Section, Division of Engineering, f
Illinois Department of Nuclear Safety, regarding the environmental impact of the proposed action. The State official had no comments.
FINDING OF NO SIGNIFICANT IMPACT Based upon the environmental assessment, the Commission concludes that the proposed action will not have a significant effect on the quality of the human environment.
Accordingly, the Commission has determined not to prepare an environmental impact statement for the proposed action.
For further details with respect to the proposed action, see the licensee's letter dated J
October 16,1997, which is available for public inspection at the Commission's Public Document
..;,7
=
, Room, which is located at the Gelman Building,2120 L Street, NW., Washington, D.C., and at the local public document room located at the Byron Public Library District,109 N. Franklin, P.O. Box 434, Byron, litinois 61010.
Dated at Rockville, Maryland, this @ day of M erus 1999.
FOR THE NUCLEAR REGULATORY COMMISSION C C
&T Stuart A. Richards, Director j
Project Directorate 111-2 Division of Licensing Project Management Office of Nuclear Reactor Regulation i