ML20206G799

From kanterella
Jump to navigation Jump to search
Supplemental Matl for First Quarter 1985 Dose Assessment Rept
ML20206G799
Person / Time
Site: Crane 
Issue date: 03/31/1985
From:
GENERAL PUBLIC UTILITIES CORP.
To:
Shared Package
ML20206G594 List:
References
NUDOCS 8606250445
Download: ML20206G799 (2)


Text

7 THREE MILE ISLAND UNIT 2 LIQUID AND GASEOUS EFFLUENTS T

(Sumary of All Releases)

,,0100'.

TYPE EFFLUENT JANUARY FEBRUARY MARCH 1st QUARTER 1985 Page 11 of 22 I.

Liquid Effluent:

A.

Fission and activation products (not including H-3 gases & alpha) 1.

Total, Release (C1) (Note 2) 1.06E-5 2.29E-5 6.37E-6 3.99E-5

2.. Concentration (u i/cc) 4.22E-12 1.15E-11 2.05E-12 5.36E-12 i

c B.

Tritium 1.

Total release (C1) 1.21E-5 1.23E-5 1.12E-5 3.56E-5 2.

Concentration (uC1/cc) 4.82E-12 6.18E-12 3.80E-12 4.78E-12 C.

Dissolved and entrained gases 1.

Total release (C1)

<LLD

<tLD

<LLD

<LLD 2.

Concentration (uci/cc)

N/A N/A N/A N/A D.

Gross alpha radioactivity 1.

Total release (C1) (Note 3)

( LLD (LW

( LLD (p

E.

Volume of waste released priortodilution(liters)(Note 1) 2.58E4 1.99E3 1.10E4 3.68E4 F.

Volume of dilution water (flow to river in liters fromNPDESReport) 2.51E9 1.99E9 2.95E9 7.45E9 G.

Number of batch releases:

10 9

8 27 "Sn The concentration of radioactive material other than dissolved or entrained noble gases in liquid

$8 effluent released to the unrestricted area shall not exceed the values specified in 10CFR 20 gt Appendix 8. Table II.

m Present liquid effluent release limits are 10% of the concentration values specified in 10CFR 20, om 88 ygg Appendix 8. Table II.

i i

ouw "ci Liquid effluent releases are also limited to 10CFR 50, Appendix I, not to exceed a dose of 3 mrem total body and 10 mrem to any organ per year.

Note 1) Includes only those releases which were found to contain radioisotopic concentration >LLD.

Note 2)

Includes Industrial Waste and Sanitary Waste.

Note 3) These activities were determmed by composite sampling

_ _ = _ _

l

ATTACHMENT 1985 UNIT 2 LIQUID RADIONUCLIDE RELEASES BY ISOTOPE (C1) k4I ge f

RADIONUCLIDE JANUARY FEBRUARY HARCH 1st QUARTER 1985 Fission and activation products (not including alpha H-3 8 gases)

<LLD

<LLD

<LLD

<tLD

<LLD

<LLD

<LLD

<LLD Ag-110m Ce-144

<LLD

<LLD

<LLD

<lLD

<LLD

<tLD

<LLD

<lLD

- Co-58

~

Co-60

<LLD

<LLD

<LLD

<LLD Cs-134

<LLD

<LLD

<LLD

<LLD Cs-137 1.09E-6 1.61E-6 1.06E-6 3.76E-6 I-131

<tLD

<LLD

<tLD

<LI.D Sr-90

  • 9.49E-6 2.13E-5 5.31E-6 3.61E-S TOTAL 1.06E-5 2.29E-5 6.37E-6 3.99E-5 H-3 1.21E-5 1.23E-5 1.12E-5 3.56E-5
  • The values reported include Sr-90 activity and any activity not specifically identified. Thus, the reported Sr-90 value represents a conservative estimate (i.e. overestimate) and contains activity fran other beta-garmn emitters which were not positively identified during conduct of analytical procedures.

l 90

_ _ _