Evaluation of Nuclear Facility Decommissioning Projects. Summary Status Report,Three Mile Island Unit 2,Reactor Coolant System & Systems Decontamination
ML20206F663
Person / Time
Site: Crane 
Issue date: 05/31/1986
From: Doerge D, Miller R, Scotti K
UNC NUCLEAR INDUSTRIES
To:
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
CON-FIN-B-7568 NUREG-CR-4315, NUREG-CR-4315-V01, NUREG-CR-4315-V1, NUDOCS 8606240547
Download: ML20206F663 (43)


Text

._

/

/

i NUREG/CR-4315 Vol.1 d

Evaluation of Nuclear Facility

Decommissioning Projects Summary Status Report Three Mile Island Unit 2 Reactor Coolant System and Systems Decontamination f

Prepared by D. H. Doerge, R. L. Miller, K. S. Scotti UNC Nuclear Industries Prepared for U.S. Nuclear Regulatory Commission P

PDR

~

5 NOTICE This report was prepared as an account of work sponsored by an agency of the United States 4

Government. Neither the United States Government not any agency thereof, or any of their employees, makes any warranty, expressed or implied, or assumes any legal liability of re-sponsibility for any third party's use, or the results of such use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such third party would not infringe privately owned rights.

i NOTICE Availability of Reference Materials Cited in NRC Publications Most documents cited in NRC publications will be available from one of the following sources:

j 1.

The NRC Public Document Room,1717 H Street, N.W.

Washington, DC 20555 i

2. The Supermtendent of Documents, U.S. Government Printing 01fice, Pmt Ottere Box 37082, i

Washington, DC 20013 7082

3. The National Technical Information Service, Springfield, VA 22161 Although the listing that follows represents the majority of documents cited in NRC publications, it is not intended to be exhaustive.

j I

Referenced documents available for inspection and copying for a fee from the NRC Public Docu l

ment Room include NRC correspondence and internal NRC memoranda; NRC Office of Inspection and Enforcement bulletins, circulars, information notices, inspection and investigation notices;

{

Licensee Event Reports; vendor reports and correspondence; Commission papers; and applicant and licensee documents and corresponderace.

The following documents in the NUREG series are available for purchase from the GPO Sales i

Program: formal NRC staff and contractor reports, NRC-sponsored conference proceedings, and NRC booklets and brochures. Also available are Regulatory Guides NRC regulations in the Code of Federal Regulations, and Nuclear Regulatory Commission issuances.

Documents available from the National Technical information Service include NUREG series reports and technical reports prepared by other federal agencies and reports prepared by the Atomic Energy Commission, forerunner agency to the Nuclear Regulatory Commission.

l Documents available from public and special technical libraries include all open literature items, such as books, journal and periodical articles, and transactions. Feabral Register notices, federal and state legislation, and congressional reports can usually be obtained from these libraries.

Documents such as theses, dissertations, foreign reports and translations,and non NRC conference proceedings are available for purchase from the organization sponsoring the publication cited.

l Single copies of NRC draft reports are available free, to the extent of supply, upon written request i

to the Division of Technical Information and Document Control U S. Nuclear Regulatory Com mission, Washington, DC 20555.

Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at the NRC Library, 7920 Norfolk Avenue, Bethesda, Maryland, and are available there for reference t e by the public. Codes and standards are usually copyrighted and may be purchased from the uginating organization or, if they are American National Standards, from the American National Standards Institute,1430 Broadway, New York, NY 10018.

NUREG/CR-4315 Vol.1 Evaluation of Nuclear Facility Decommissioning Projects Summary Status Report Three Mile Island Unit 2 Reactor Coolant System and Systems Decontamination Manuscript Completed: February 1986 Date Published: May 1986 Prepared by D. H. Doerge, R. L. Miller, K. S. Scotti UNC Nuclear Industries Richland, WA 99352 Prep: red for Division of Engineering Technology Offics of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, D.C. 20555 NRC FIN B7568

ABSTRACT This document summarizes information relating to the decontamination and restoration of the Three Mile Island Unit 2 reactor coolant system and other plant systems.

Data have been collected from activity reports, reactor containment entry records, and other sources and entered in a computerized data system which permits extraction / manipulation of specific data which can be used in planning for recovery from a loss of coolant event similar to that experienced oy the Three Mile Island Unit 2 on March 28, 1979.

This report contains a summary of radiation exposures, manpower, and time spent in radiation areas during the referenced period.

Support activities conducted outside of radiation areas are not included.

Computer reports included are:

e A chronological listing of all activities related to decontamination and restoration of the reactor coolant system and other plant systems for the period of April 5, 1979, through December 19, 1984.

e A summary of labor and exposures by department for the same time

period, o Summary reports for each major task undertaken in connection with this specific work scope during the referenced time period.

[

iii

TABLE OF CONTENTS PAGE

1.0 INTRODUCTION

1 2.0

SUMMARY

OF LABOR AND EXPOSURES BY DEPARTMENT..........

3

3.0 DESCRIPTION

OF COMPUTER REPORTS 4

3.1 TMI-2 Acronyms and Abbreviations.............

4 3.2 THI-2 Notes and Descriptions...............

4 3.3 Activity Report - THI-2 Reactor Coolant' Systems (RCS) and Systems Decontamination (chronological summary)...... 6 3.4 Activity Report - TMI-2 RCS and Systems Decontamination -

Summaries of Individual Tasks...............

6 4.0 COMPUTER REPORTS........................

8 4.1 TMI-2 Acronyms and Abbreviations 8

4.2 TMI-2 Notes and Descriptions 14 4.3 Activity Report - TMI-2 RCS and Systems Decontamination (chronological summary).................

17 1

4.4 Activity Report - TMI-2 RCS and Systems Decontamination -

4 i

Summaries of Individual Tasks..............

26 i

4 v

l

~

l l

l EVALUATION OF NUCLEAR FACILITY DECOMMISSIONING PROJECTS PROGRAM THREE MILE ISLAND UNIT 2 Reactor Coolant System and Systems Decontamination

1.0 INTRODUCTION

The Three Mile Island Unit 2 (TMI-2) nuclear power station is located near Middletown, Pennsylvania.

TMI-2 is a pressurized water reactor rated at 959 MWe. The reactor began commercial operation on December 30, 1978.

On March 28,1979, TMI-2 experienced a partial loss of coolant water which exposed the upper portion of the reactor.

Resulting temperatures in the core region were in excess of 2500F causing considerable damage to the core and possibly to other reactor components.

Contaminated reactor coolant water was released to the reactor building basement and to the auxiliary and fuel handling buildings (Figures 1 and 2). This release resulted in gross contamination requiring extensive decontamination and waste handling operations to restore these buildings.

Decontamination and repair activities have required many labor man-hours and man-rems of exposure.

Because of the vast quantity of data generated during decontamination, equipment recovery and waste handling activities, the U. S. Nuclear Regulatory Commission (NRC) requested that the data be assembled, analyzed, and entered into a computer data base for historical purposes.

The information also serves as a comprehensive base line for future planning, estimates, and actions required should a nuclear facility be confronted with problems similar to those experienced at TMI-2.

Work within the scope of this report is being conducted under the Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program.

The ENFDP program was originated in 1981 under the auspices of the NRC Office of Nuclear Regulatory Research and is currently acministered through the Division of Engineering Technology.

UNC Nuclear Industries (UNC) is responsible for technical direction of the program and for preparation of documentation and summary comparisons of evaluated projects. See NUREG/CR-2522, " Evaluation of Nuclear Facility Decommissioning Projects," for a complete description of the Program Plan.

Under the ENFDP program, data is assembled in a form that permits input into a computerized decommissioning data system (DDS). A proprietary computer software package, MAPPER, provides a method for accumulation and manipulation of decommissioning performance information. MAPPER stands for Maintain, Prepare, and Produce Executive Reports.

THREE MILE ISLAND UNIT 2 REACTOR EU;1Dii;G (C0~1TtJf.'T.1ElT, AUXIUARY BU!LDl?JG C00UNG TOVAR ig s...

g,4.........

i g

i s...,,, s ij ll

.;- M'. v. a.i r.ieri w...

i c. -- ;

bi Ilmalij2 EURD1I'G u.:........u.,

n... m l Ny..;..,,

..w.

s.

i.- i -

i.,...

7

'.-@4, i

T,3 i

g y__ i i

v...... q

.J.;.

,f***

F::.:.

qo 1 a.r..c,.- i h' c 4,_.,_

__. c. "/"_ _.i L ' * "'

v,.,,,,. - 3, i-aew.

i o

c. i u r.:u, n...

t,n.. :..,-

,,g_

,;_;;;;;;;_===_

m i

,-,. p.

,m,,.,, _,

, u.n y'/!

u.. i. % -

p d ' = ' '-- =- m o; 5

' c,L.r. ;*;

g G$-pa'.

.iv.a.3%

m.. g-s......., r--l 3 c..s.-s

......!~

g-

.n

,..,w e, o

w m--il

..... _c: u v.

m._N--i y

+l l

,a,.,..

m.

w n,a m _w,

w

_m m

i i..

u, c.

-~

_i -

w.

s.,.. w s --

e a _

.q e

w.............

........1.......x....,

~ '. -

c.o, Figure 1. Reactor & Auxiliary Buildings.

\\

3,

+

i m v e

n..

77_.. _-

w+

l

=w m

i

,. r-i c,.m...=.

[

s i 4.

s i,

ii

..y U.

..c.i,a -

+=

a,

~

aJ u.

i

_. s.._ _..

m

.. o a w

-a

.g r.:

e..

o c

m G.

r Qc-3 oo

.D..

/

, o~

J" N/

  • -a 3 O

I I

-- L

_j 0

0

~

~~q jl hL

- 1..-r a r, ~. _M_i.

t A. P(--,

o

=

(...

=

.u.

9

=

(....=

(

o Io m

- - -. a a

c.:..._.,,.. m.

m

.2

......p.

ll:'l':, ;;=

l,,. :

u----=---- a

-n

.:.m...

m m

'A. ';

Figure 2. Auxiliary & Fuel-Handling Building.

l l

Because of the volume and variety of information being collected at TMI-2, nine categories of ENFDP reports have been established and are as follows:

Volume 1 - Reactor Coolant System and Systems Decontamination Volume 2 - Reactor Building Decontamination Volume 3 - Reactor Defueling and Disassembly Volume 4 - Auxiliary and Fuel Handling Building Decontamination Volume 5 - Common Support Facilities and Systems Operations Volume 6 - Plant Stability and Safety Activities Volume 7 - Liquid Waste Handling Volume 8 - Solid Waste Handling Volume 9 - Radioactive Waste and Laundry Shipments Periodic activity status and summary reports for these nine categories will be published as NUREG/CR-4315 Three Mile Island Unit 2 documents.

This report covers activities relating to decontamination and repair of the Reactor Coolant System (RCS), see figure 3, and other reactor systems for the period of April 5, 1979 through December 19, 1984.

Data have been collected from activity reports, reactor containment entry records, and other sources. This report contains a summary of radiation exposures, manpower, and time spent in radiation areas, during the period referenced,- in chronological order.

Additionally, summary reports for each major task related to decontam-ination and repair of the RCS and other reactor systems, and a summary of labor and exposures by department (manually assembled) are included.

2.0

SUMMARY

OF LABOR AND EXPOSURES BY DEPARTMENT The following (Table 1) is a manually-assembled summary of labor and exposures by department for the period April 5, 1979 through December 19, 1984.

l __

l TABLE 1 Personnel Labor Exposure Entries Man-Hours Man-Rem 4

AD Unit 2 Administration 2

2.75 0.015 CH Chemistry - Unit 1 6

12.16 0.027 CM Unit 2 - Maintenance (General) 57 111.24 0.021 CN Contractor (all crafts) 342 686.57 6.262 CR Corporate 110 206.36 1.584 DM Unit 2 Decon Maintenance 8

20.66 0.010 EG Engineering Staff - Unit 1 2

5.89 0.011 EL Unit 2 Engineering Staff 12 10.42 0.220 ES Unit 2 Engineering Staff 9

26.67 0.113 HP Health Physics (Rad Engineering) 109 246.52 2.155 IC Unit 2 Instrument and Control 30 72.18 0.046 ME Mechanical Maintenance - Unit 1 2

1.40 0.060 MM Unit 2 Mechanical Maintenance 110 256.99 1.200 OP Unit 2 Site Operations 175 678.07 1.607 OS Operations - Unit 1 1

1.08 0.020 QA Quality Assurance 10 13.13 0.068 RP Unit 2 Recovery Programs 8

38.80 0.078 RW Rad Waste - Unit 1 1

3.67 0.008 UM Unit 2 Utilities Maintenance 80 157.97 1.210 VI Visitor 1

DNA*

0.025 TOTAL RCS AND SYSTEMS DECON TIU75 2,552.53 14.740 i

  • Data Not Available - RWP hours were not recorded in 1979.

i

3.0 DESCRIPTION

OF COMPUTER REPORTS The computer reports included in this document are:

3.1 Activity Report TMI-2 Acronyms and Abbreviations This is a general report master listing of acronyms and abbreviations used in TMI-2 reports. All acronyms and abbreviations shown in this general report may not necessarily appear in this document but may be contained in the other volumes of NUREG/CR-4315, THREE MILE ISLAND UNIT 2.

3.2 Activity Report - TMI-2 Notes and Descriptions This report describes the data for each column listing in these activity reports.

It also includes a separate department code abbreviation listing which does not appear in the master TMI-2 acronyms and abbreviations report.

i TMI-2 Reactor Coolant System Y

N Station North 7

X N/ "

A.h.f valv. nozzi.s Cor. ficos tann A D

Spray on.

V C

y or. flooc tank a S 0 1

RC-P-2A RC-P-2B in.

Aux I

FW Inl.t v

HP Q

  • g inj r

Auw R

P-1A I

iit "

gpelfigw w

el.*.,

P c- - -

Main g

hg h.a er -

L nosti..

A

/

c j

p

I

]

nozzi./j (V DH O O.g si..rn a.n.r.ier.A g,

i si..m g.n.rator a no,"l,.

k....., v....,

Figure 3. __

= _.

3.0 DESCRIPTION

OF COMPUTER REPORTS 3.3 Activity Report - TMI-2 Reactor Coolant System and Systems Decontamination This report is a chronological summary of data on manpower, radiation exposure, and labor man-hours spent in radiation areas during decontamination of the reactor coolant system and other systems. Each line of this report represents a task performed, man-hours spent, and radiation exposure received by various department personnel during performance of that task.

3.4 Activity Reports - TMI-2 Reactor Coolant System and Systems Decontamination - Summaries of Individual Tasks Eight separate areas of activity.are summarized for the period of April 5, 1979 through December 19, 1984. Those activities were:

o RCS DECONTAMINATION Reactor Coolant System Decontamination o AFHB SYS & TKS DECON Auxiliary and Fuel Handling Building Systems and Tanks Decontamination o RCBT B&C DCCON Reactor Coolant Bleed Tank B&C Decontamination o RCBT A DECON Reactor Coolant Bleed Tank A Decontamination o MAKEUP FILTERS DECON Makeup Filters Decontamination o PWST DECON Process Water Storage Tank Decontamination o OTSG B DECON Once Through Steam Generator B Decontamination o SYS & TKS RX DECON Reactor System and Tanks Decontamination l

i e,

Table 2 compiles these eight individual ~ summary reports and, again, presents the total exposure and man-hours expended on tasks during the period covered by this report, TABLE 2

SUMMARY

OF LABOR AND EXPOSURES BY TASK 4

April 5, 1979 through December 19, 1984 Labor Exposure Task Description (Man-Hours)

(Man-Rem)

RCS Decon 353.93 1.960 AFHB SYS & TKS Decon 295.69 3.518 RCBT B&C Decon 129.19

.806 RCBT A Decon 302.84 2.452 Makeup Filters Decon 378.16 3.539 PWST Decon 147.35

.076 OTSG B Decon 865.91 2.046 SYS & TKS RX Decon 59.46

.343 TOTALS 2,552.53 14.740 9

, 4

--g,--..-

,e-r,

-e---

n

--,rnm

i l

4.0 COMPUTER REPORTS 4.1 TMI-2 Acronyms and Abbreviations t

DATE 062485 PAGE 2

PNO.

1

.TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR THI-2 REPORTS M H3036

.T,FLD.

  • A.C.R O.N. YM.... M.OD.. P. N.U.M...................D.E.S.C.R.IP.T.

ION................................................................................

. e...

  • THIS REPORT IS A WORKING DOCUMENT AND WILL BE UPDATED PERIODICALLY.
  • (SOME ABBREVIATIONS FOUND IN DATA HAVE NOT BEEN IDENTIFIED TO DATE, THESE
  • ABBREVIATIONS OR ACRONYMS WILL BE IDENTIFIED AND INCLUDED IN SUBSEQUENT
  • REPORTS)

ACC ACCESS ACOUS ACOUSTIC OR #COUSTICAL ACQ ACQUISITION ACQUI ACQUISITION ADPTR ADAPTER AFHB AU%ILIARY AND FUEL HANDLING BUILDING AH AIR HANDLING AHE AIR HANDLING EQUIPMENT AHVG AIR HANDLING VALVE

'G' AH-C AIR HANDLING VALVE

'C' I

ALC AUXILIARY LIQUID CLEANUP (EPICOR 2)

W3 Ahd ANNULUS 8

APSR AXIAL POWER SHAPING ROD ARLK AIRLOCK AUX AUXILIARY (BUILDING)

BLK BLOCK BTL(S)

BOTTLE (S)

BWST BORATED WATER STORAGE TANK B&W BABC0CK & WILCOX CAT CHEMICAL ADDITION TANK CCB CHEMICAL CLEANING BUILDING CCTB CHEMICAL CLEANING TANK

'B' CCTV CLOSED CIRCUIT TELEVISION CDT CONDENSATE DRAIN TANK CFT CORE FLODD TANK CHEM ADD CHEMICAL ADDITION CHK CHECK CLR(S)

COOLER (S)

CNTRL CONTROL COL COLUMN CONC CONCENTRATED COND CONDENSER OR CONDENSATE CONN CONNECT OR CONNECTOR CONST CONSTRUCT OR CONSTRUCTION CONT -

CONTAMINATED CONTR CONTRACTOR CORR CORRIDOR CGUP COUPLE OR COUPLING COV COVERAGE CRO CONTROL ROD DRIVE CRDM CONTROL ROD DRIVE MECHANISM CTMT CONTAINMENT CU CLEAN UP i

DATE 062485 PAGE 3

PNO.

2

.TMI-2 UNC: DOS - ACRONYMS AND AB8REVIATIONS FOR TMI-2 REP 0dTS H H3036

.T.FLD.

  • AC.RO.N.Y.M.... MO.D.. P.. N. U.M.

..................D.E.S.C.RIPT.I.O.N................................................................................

3..

CONTAMINATED WASTE STORAGE TANK CWST CWT CONTAMINATED WASTE TANK DEBOR DE80 RATED OR DE80 RATING DECCN DECONTAMINATION DEMIN DEMINERALIZER DH DECAY HEAT DHV DECAY HEAT VAULT DISCON DISCONNECT DP DIFFERENTIAL PRESSURE DSMNTL DISMANTLE DWCS DEFUELING WATER CLEANUP SYSTEM EFF EFFLUENT EL ELECTRICAL OR ELEVATION ELEC ELECTRIC OR ELECTRICAL ELEVTR ELEVATOR ELEV(S)

ELEVATION (S)

EQUIP EQUIPMENT e

EVAP EVAPORATOR EXP EXPERIMENT

_a C3 FAC FACILITY e

FHS FUEL HANDLING BUILDING FILT FILTER FLNGE FLANGE FLT FILTER FSV FIRE SERVICE VALVE FTC FUEL TRANSFER CANAL FTS FUEL TRANSFER SYSTEM FUNCT FUNCTION OR FUNCTIONAL GEN GENERAL GLV8X GLOVE 80X HOR HEADER HEPA HIGH EFFICIENCY PARTICULATE AIR HI LEV HIGH LEVEL (WASTE)DIOLOGICAL EN1INEERING)

HP HEALTH PHYSICS (RA HPR HEALTH PHYSICS IN-LINE MONITOR HRF-68 HIGH RAD FILTER GLOVE 80X HSEKPG HOUSEKEEPING HVAC HEAT VENTILATION, AIR CONDITIONING H-2 HYDR 6 GEN ICC INTERMEDIATE CLOSED COOLING WATER SYSTEM IIF INTERNALS INDEXING FIXTURE INF INFLUENT INJ INJECTION INSP INSPECT OR INSPECTION INST INSTRUMENT OR INSTRUMENTATION INSTL INSTALL OR INSTALLATION INTERMED INTERMEDIATE LA8 LABORATORY LD LEAD LL LOW LEVEL (WASTE)

DATE 062485 PAGE 4

PNO.

3

.TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR THI-2 REPORTS M H3036

.T.FLD.

  • . A.C. R. O.N Y.M.... M. O.D. P.. N. U.M.

................D.E.S.C.R..IP.T..IO.N................................................................................

LN(S)

LINE(S)

LOCA LOSS OF COOLANT ACCIDENT LP LDW PRESSURE MAG MAGNETIC MAINT MAINTAIN OR MAINTENANCE MAIL MATERIAL MB MC MOTOR CONTROL MC CTR MOTOR CONTROL CENTER MDH MINI-DECAY HEAT MDHR MINI DECAY HEAT REMOVAL SYSTEM MEAS MEASURE OR MEASUREMENT MISC MISCELLANEOUS MONIT(S)

MONITOR (S)

MOV MOTOR OPERATED %'ALVE MT EMPTY MU MAKE UP s

MUF MAKE UP FILTER

_a MUP MAKE UP PUMP

-s MUV MAKE UP VALVE e

MW MISCELLANEOUS WASTE MWHT MISCELLANEOUS WASTE HOLDUP TANK MWT HISCELLANEOUS WASTE TANK NEUT NEUTRON NI NUCLEAR INSTRUMENT OR INSTRUMENTATION NLB MANUFACTURER'S NAME FOR HYDROLASER PUMP NM NITROGEN MAN! FOLD N0ZZ N0ZZLE NRC U.

S NUCLEAR REGULATORY COMMISSION NS NUCLEAR SERVICE NUC NUCLEAR NUC INST NUCLEAR INSTRUMENTATION N-2 NITROGEN OPER OPERATION OPS OPERATIONS OTSG ONCE THROUGH STEAM GENERATOR PACK PACKAQE PC OR P.C.

POLAR CRANE PENET PENETRATION PERS PERSON (S) OR PERSONNEL PHOTO PHOTOGRAPH OR PHOTOGRAPHIC PKG PACKAGE PM OR P.M.

PREVENTATIVE MAINTENANCE l

PMP PUMP i

l PORV PRESSURE OPERATED RELIEF VALVE l

PREP PREPARATION PROT PROTECTION PWST PROCESS WATER STORAGE TANK PZR PRESSURIZER RAD RADIATION, RADI0 ACTIVE, RADIOLOGICAL t

MM M05 l

DATE C62485 PAGE 5

PNG.

4

.TMI-2 UNC: DDS - ACRONYMS AND AEBREVIATIONS FOR TMI-2 REPORTS M M3036

.T.FLD.

A..C.R O. NY.M.... MOD.. P. N.UM...................D. E. S. C. R. I P T. I O. N.........................

ROOMIS)

R0-2A RADIATION DETECTION INSTRUMENT

-s RV REACTOR VESSEL DJ RVHSS REACTOR VESSEL HEAD SERVICE STRUCTURE I

RWP RADIATION WORK PERMIT SAM COMMUNICATIONS SYSTEM SAMP SAMPLE SCAF SCAFFOLD SDS SUBMERGED DEMINERALIZER SYSTEM SECT SECTION SERV SERVICE SF SPENT FUEL SFC SPENT FUEL COOLER SFF SPENT FUEL FILTER SFP SPENT FUEL POOL SFV SHLD(G)

SHIELD OR SHIELDING SPC STANDBY PRESSURE CONTROL SPEC SPECIAL OR SPECIFICATION SPEC (T)

SPECTRA, SPECTRUM, OR SPECTROMETER SSTR i

STAB STABILIZE OR STABILITY I

SUPP SUPPORT SURV SURVEY SWS-P PUMP IN SPENT FUEL POOL (REMOVED)

SYS SYSTEM TEMP TEMPORARY TER TERMINATE OR TERMINAL THRU THROUGH TK(S)

TANK (S)

TLD THERM 0 LUMINESCENT DOSIMETER TRO TUR8 TURBINE (BUILDING)

TV TELEVISION UCI MICR0 CURIE R

t DATE 062485 PAGE 6

PNO.

5

.TMI-2 UNC: DDS - ACRONYMS AND ABBREVIATIONS FOR TMI-2 REPORTS M H3036

.T.FLD.

  • ..C. R O. N YM.. M. OD.. P.. NU.M...................D. E. S. C. R..I P T I O N..........................
  • A V

VALVE (USED IN CONJUNCTION WITH A NUMBER OR LETTER)

VAC VACUUM VLV VALVE WOG WASTE DISPOSAL-GASEOUS WOL WASTE DISPOSAL-LIQUID WDS WASTE DISPOSAL-SOLID XFR TRANSFER XPORT TRANSPORT END REPORT s

a 00 a

l

4.0 COMPUTER REPORTS 4.2 TMI-2 Notes and Descriptions

DATE 062485 PAGE 2

PNO.

I

.TMI-2 UNC: DDS - ACTIVITY REPORT - TMI-2 NOTES AND DESCRIPTIONS M 286 0

.RWP

.EXP TRCK.

.PERS

. DE PT. EXPOS RWP.

....... T. A S. K D. E. S.C R.I P. T I O. N...................

  • D. A. T E... N U.MB.E. R.. N.U.MB.E.R.......... A C. T. I V. I T. Y............... E. N T R NG....C. O.D. E...... R. E.M..... U. R. S........

HO s.

  • DATA IN THIS REPORT ARE COMPLETE THROUGH MARCH 31, 1985.

SUBSEQUENT DATA

  • WILL BE ANALYZED AND ADDED PERIODICALLY.
  • NOTES:
  • 1.

DESCRIPTION OF DATA IN EACH COLUMN; RWP DATE -

THE DATE OF ISSUE OF THE RADIATION WORK PERMIT.

THE PERMIT MAY COVER A SINGLE ENTRY OR MAY COVER ENTRIES OVER A PERIOD OF TIME OF UP TO ONE WEEKS DURATION.

RWP NUMBER -

RADIATION WORK PERMIT IDENTIFICATION NUMBER.

EXP TRCK NUMBER-EXPOSURE TRACKING NUMBER - AN IDENTIFICATION NUMBER ASSIGNED TO A SPECIFIC ACTIVITY.

e

-s ACTIVITY -

DESCRIPTION OF AN ACTIVITY OR THE LOCATION OF A Cn TASK WITHIN AN ACTIVITY.

0 PERS ENTRG -

NUMBER OF PERSONNEL ENTERING A RADIATION AREA OR PERFORMING WORK WHICH IS COVERED BY AN RWP DEPT CODE -

A PERSONNEL ACCOUNTING CODE FOR FUNCTIONAL DE PARTMENT IDENTIFICATION. (SEE NOTE 2)

EXPOS REM -

ACTUAL RADIATION EXPOSURE IN REM. RERCORDED ON TLDS WORN BY EMPLOYEES DURING fERFORMANCE OF A TASK WHICH IS COVERED BY AN RWP.

AN EMPLOYEE MAY WORK ON AN RWP COVERED TASK FOR SEVERAL HOURS AND RECEIVE NO MEASUR-ABLE RADIATION EXPOSURE.

l 1

RWP HOURS -

TIME SPENT ON A TASK INCLUDING JOB PREPARATION, DRESS-UNDRESS. ETC.

RECORD WAS INITIATED IN NOVEMBER, 1979.

TASK DESCRIPTION - SELF EXPLANATORY

  • 2.

DEPARTMENT CODE ABBREVIATIONS:

80 - UNIT-2 ADMINISTRATION AM - ADMINISTRATION - UNIT 1 BS - UNIT-2 BUILDING SERVICES CH - CHEMISTRY-UNIT 1 CM - UNIT-2 PLANT OPERATIONS MAINTENANCE - GENERAL CN - CONTRACTOR (ALL CRAFTS)

CR - CORPORATE DM - UNIT-2 DECON MAINTENANCE (REPLACED BY RECOVERY PROGRAM-RP)

EC - ELECTRICAL MAINTENANCE - UNIT 1 EG - ENGINEERING STAFF-UNIT I l

l l

l M

c-,

DATE 062485 PAGE 3

PNO.

2

.TMI-2 UNC: DDS - ACTIVITY REPORT - TMI-2 NOTES AND DESCRIPTIONS M 286 D

.RWP

.EXP TRCK.

.PERS

. DEPT. EXPOS RWP.

TASK DESCRIPTION

  • ... T.E... NUM. BE.R. N UMB E.R.......... A. C. T I. V..I T. Y................ E. N T R N.G.. CO.DE..

...E.M....HOU.R S........

R EL - UNIT-2 PLANT OPERATIONS ELECTRICAL MAINTENANCE ES - UNIT-2 E NGINEERING STAFF HP - UNIT-2 HEALTH PHYSICS IC - UNIT-2 PLANT OPERATIONS (RADIOLOGICAL ENGINEERING)

INSTRUMENT AND CONTROL MD - UNIT-2 MAINTENANCE ADMINISTRATION ME - MECHANICAL MAINTENANCE-UNIT I MM - UNIT-2 PLANT OPERATIONS MECHANICAL MAINTENANCE OP - UNIT-2 SITE OFERATIONS OS - OPERATIONS-UNIT I QA - UNIT-2 QUALITY ASSURANCE RC - RADIATION CONTROL-UNIT I RP-UNIT-2 RECOVERY PROGRAM RW - RAD WASTE - UNIT I SE - UNIT 2 SECURITY l

UM - UNIT-2 UTILITIES MAINTENANCE UT - UTILITIEO MAINTENANCE - UNIT I V! - VISITOR j

j, END REPORT m

I 8

l l

l l

l l

l 1

l l

d fl

4.0 COMPUTER REPORTS 4.3 TMI-2 RCS and Systems Decontamination -

Chronological Summary of Activities From April 5, 1979 through December 19, 1984 1.

DATE 021886 PAGE 2

PNO.

1

. T Ml:2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.PERS DEPT. EXPOS.RWP 1"kWP-

.RWP

.EXP TRCK.

........ E. N T R G... C. O.D. E... R E.M..... H. O. U. R. S....,i......,.........................................

A TASK DESCRIPTION

  • D. ATE... NU.MB.E.R. N.U.MB.E.R............C. T. I V. I. T. Y....... s 0.00 RECOMBINER COVERAGE

<a 790405 022221 E30C001 AFHS SYS & TKS DECON 4 CN 0.055

, *790405 022221 E30C001 AFHB SYS & TKS DEcuN 1 VI 0.025 0.00

'RECOMBINER COVERAGE

-790439 022156 E30C001 AFHB SYS & TMS DECON 2 EL 0.016 0.00 MOVE CABLE TO RECOMBINER 790409 022143 E30J001 ~775 & TKS RX DECON 8 CN 0.000 0.00 TRANSFER RACKS FROM A TD 8 POOL

  • 790409 022143 E30J001 SYS & TKS RX DECON 1 MM 0.000 0.00 TRANSFER RACKS FROM A TO 8 POOL 790410 022128 E30J001 SYS & TKS RX DECON 10 CN 0.167 0.00 TRANSFER RACKS FROM A TO B POOL 8790J10 022128 E30J001 SYS & TMS RX DECON 1 OP 0.030 0.00 TRANSF(1 RACKS FROM A TO 8 POOL
  • 79C410 022128 E30J001 SYS & TKS RX DECOG 3 MM C.020 0.00 TRAhSFER RACKS PROM A TO 8 POOL 790413 021363 E30C001 AFHB SYS & TKS DECON 3 EL 0.180 0.00 CHECK POWER CABLE FCR RECOM81NER.

790615 028748 E30D056 RCBT B&C DECON 4 CN 0.030 0.00 MOVE RECOMB-FUEL POCL TO INTERMED BLOG 800123 050487 E30C001 AFHB SYS & TKS DECON 1 CN 0.020 1.58-INSTALL TENT AROUND RECUMBINER

  • 800123 080487 E30C001 AFHO SYS & TKS DECON 2 CR 0.040 2.00 INSTALL TENT AROUND RECOMBINER 800124 080502 E30C001 AFHB SYS & TKS DECON 1 CR 0.070 2,08 INSTALL TENT AROUND RECOMBINER 100124 080517 E30C001 AFH8 SYS & TKS DECON 1 CN 0.005 1.75 DECON H-2 RECOMBINER PAD
  • 800124 080517 E30C001 AFHB SYS & TKS DECON 1 CR 0.005 1.33 DECON H-2 RECOMSINER PAD 800125 080546 E30C201 AFH8 SYS & TKS DECON 1 CN 0.000 1:00 DECON H-2 RECOMBINER PAD 3800125 080546 E30Cc91 AFHS SYS & TKS DECON j CR 0.005 1.90 OECON H-2 RECOMBINER PAD 800*25 0B0547 E30C001 AFHS SYS & TMS DECON

'l CR 0.000 1.00 INSTALL TENT AROUND RECOMBINER 800128 080621 E30C001 AFHB SYS & TKS DECON 2 CN O,180 1.75 DECON SPILL INSIDE RECOMOINER TENT 8800128 080621 E30C001 AFHB SYS & TKS CICON.

1 CR 0.105 0.08 DECON SPILL INSIDE RECOMBINER TENT 800324 081301 E30C001 AFHB SYS & TKS DECON 1 CM 0 \\ 0I0 '

1.10 DECON H-2 RECOMBINER e

  • 800324.081801 E30C001 AFHB SYS A TKS DECON 1 CR 0 018 1.05 DECON H-2 RECOMBINER a
  • 800324 081801 E30C001 AFHB SYS & TKS DECON 1 UM 9.028 0.76 DECON H-2 RECOMBINER 00 800325 081829 E30C001 AFHB SYS & TKS DECON 1 CN 0.023 1.33 DECON H-2 RECOMBINEt 8
  • 800325 081829 E30C001 AFHB SYS & TKS DECON 2 CR 0.048 1.92 DECON H-2 RECOMBINER 800327 081881 E30C001 AFHB SYS & TKS DECON 3 CN 0.038 1.95 XFER RECOMB BLOWE TROM TENT /DECON TENT
  • 800327 081881 E30C001 AFH8 SYS & TKS DECON 1 CR 0.020 0.93 XFER RECOMB 3LDWER FROM TENT /CECON TENT

. 3800327 0B1881 E30C001 AFHB SYS & TKS DECON 1 UM 0.020 0.93 XFER RECOMS'BLQWER FROM TENT /DECON TENT 800414 082291 E30D40A MAKEUP FILTERS DECON 1 CN 0.010 1.33 STAGE AREA T4 r;.%L FIL TE R S 2 A.2 8.5 A.5 B

  • 800414 082291 E30040A MAKEUP FILTERS DECON 4 CR 0.040 4.33 STAGE ARFA TC PVLL F ILTERS 2A.23.5A.58 800415 082301 E30D40A MAKEUP FILTERS DECON 3 CN 0.055 3.67 REMOVE MAKEUP 'If,TERS 2A & SA 3800415 082301 E30040A MAKEUP FILTERS DECON 2 CR 0.025 1.50 REMOVE MAKEUP FILTERS 2A & SA 200415 082302 E30040% MAKEUP FILTERS DECON 4 CN 0.075 5.13 MOVE FLTR TRANSPCRT SHIELD TO SHLD CASK
  • 800415 082302 E30040A MAKEUP FILTERS DECON 2 CR 0.010 1.67 MOVE FLTR TRANSPORT SHIELD TO SHLD CASK
  • 800415 082302 E30D40& MAKEUP FILTERS DECON 1 UM 0.000 1.00 MOVE FLTR TRANSPORT SHIELD TO SHLD CASK 80C501 0B2716 E30D40A MAKEUP FILTERS DECON 5 CN 0.040 4.92 ASSESS SOLIDS ON MUF-54 FILTER HOUSING
  • 800501 082716 E30D40A MAKEUP FILTERS DECON 2 CR 0.020 2.00 ASSESS SOLIDS ON MUF-5A FILTER HOUSItG 800514 083020 f30C001 AFHS SYS & TKS DECON 1 CN 0.005 0.57 STAGE FOR FLUSH OF PECOMBINER FILL SYS 800516 083083 E30C001 AFHB SYS & TKS DECCN 4 CN

/ 0.015 10.00 FLUSH RECOMBINER/ CHANGE FILTERS

  • 800516 083083 E30C001 AFHP SYS & TMS DECON 3 CR 0.010 9.00 FLUSH RECOM81NER/ CHANGE FILTERS 800520 0B3137 E30C001 AFHB SYS & TMS DECON 2 CN 0.040 0,00 DRAIN & REFitL RECOMBINER 800522 083206 E30C001 AFH8 SYS & TKS DEC04 2 CN 0.020 5.67 FLUSH RECOMu!NER TO DRAIN 800528 G33282 E30C001 AFHB SYS & TKS DECD4 1 CN 0.000 3.25 DECON RECDM11NER INTERNALS & FLUSH 800530 083358 E30C001 AFHS SYS & TKS DECON 2 CN 0.005 2.00 FLUSH RECDMBINER/ CHANGE FILTER 800626 0B3903 E30C001 AFHB SYS & TKS DECON '

1 CN 0.005 1.33 DECON RECOMBINER TENT

  • 800626 083903 E30C001 AFMB SYS 87IKS DECON' 1 CR 0.000 1.33 CECON RECOM31NER TEhT 800703 084022 E30C001 Af h8 SYS & TKS:DTCON 1 CN 0.005 5.75 OiCON RECONSINER TD:T 8800703 084022 E30C001 AFHB SYS & TKS DECON 2 CR 0.010 5.67 DECON RECOMBINER TENT 800726 084321 E30C001 AFHB SYS & TKS DECON 1 CN 0.000 0.42 CMG FLTRS/DECON HOT SPOTS IN RECOM8 TENT

$800726 084321 E30C001 AFHS SYS & TKS DECON 1 CR 0.000 0.42

.CHG FLTRS/DECON HOT SPOTS IN RECOM8 TENT J

d 3

DATE 021886 PAGE 3

PNO.

2

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS

. DEPT. EXPOS.RWP TA

  • DATE... NUMBER.NUMBE.R

..............I V.I T Y.......s......... E. N T R G. C OD E... R E.M...........S....

............... S. K D. E. S. C. R I P T I. O N.........................

ACT

. HOUR 800728 084326 E30C001 AFHB SYS & TKS DECON 3 CR 0.002 4.68 FLUSH RECOMBINER C0ILS

  • 800728 084326 E30C001 AFNB SYS & TMS DECON 1 EL 0.005 3.17 FLUSH RECOMBINER COILS 800728 084350 E30C001 AFHB SYS & TKS DECON 3 CN 0.000 4.33 DECON RECOMBINER TENT / BAG JOINTS 800828 OB9308 E30C001 AFHB SYS & TKS DECON 3 CN 0.000 16.25 FLUSH RECOMBINER
  • 800828 089308 E30C001 AFHS SYS & TKS DECON 6 CR 0.015 23.17 FLUSH RECOMBINER 800904 089335 E30C001 AFHS SYS & TKS DECON 1 CN 0.000 2.50 FLUSH RECOMBINER 2800904 089335 E30C001 AFHB SYS & TKS DECON 1 CR 0.000 2.50 FLUSH RECOMBINER 800909 084933 E30040A MAKEUP FILTERS DECON 3 CN 0.015 1.83 DRV RUN TRAINING FOR FILTER CHANGE 800910 084951 E30C001 AFNB SYS & TKS DECON 4 CN 0.015 11.66 ADD WATER TO RECDMBINER & FLUSH
  • 800910 084951 E30C001 AFHB SYS & TKS DECON 6 CR 0.002 14.17 ADD WATER TO RECOMBINER & FLUSH 800910 0B4944 E30040A MAKEUP FILTERS DECON 9 CN 0.093 10.26 TRAINING FDR MUF CHANGE / STAGE FOR CHANGE
  • 800910 084944 E30D40A MAKEUP FILTERS DECON 1 EL 0.005 1.33 TRAINING FOR MUF CHANGE / STAGE FOR CHANGE
  • 800910 084944 E30D40A MAKEUP FILTERS DECON 1 HP 0.008 1.08 TRAINING FOR MUF CHANGE / STAGE FOR CHANGE
  • 800910 084944 E30D40A MAKEUP FILTERS DECON 3 CR 0.030 3.50 TRAINING FOR HUF CHANGE / STAGE FOR CHANGE 800911 084954 E30D40A MAKEUP FILTERS DECON 3 CN 0.085 3.17 REMOVE MU FILTERS 2A, 28, 58 2800911 084954 E300404 MAKEUP FILTERS DECON 3 CR 0.080 3.17 REMOVE MU FILTERS 2A, 28. 58
  • 800911 084954 E30D40A MAKEUP FILTERS DECON 1 HP 0.010 1.08 REMOVE MU FILTERS 2A. 28 58 800912 084971 E30D40A MAKEUP FILTERS DECON 3 CN 0.025 2.58 REMOVE MU FILTERS 2A, 28 5B 2800912 084971 E30D40A MAKEUP FILTERS DECON 3 CR 0.030 2.17 REMOVE,MU FILTERS 2A, 2B, 58 2800912 084971 E30D40A MAKEUP FILTERS DE*0N 1 HP 0.020 0.92 REMOVE MU FILTERS 2A 28, 58 801010 085263 E30D40A MAKEUP FILTERS DEC]N 5 CN 0.083 7.50 HYDROTEST MDH FLTR/INSTL TUBING VALVES 8
  • 801010 085263 E30D40A MAKEUP FILTERS DLCJN 1 CR 0.010 1.17 HYDROTEST MDH FLTR/INSTL TUBING VALVES

-d 801021 085366 E30D40A MAKEUP FILTERS DECON 2 CN 0.020 1.67 HYDRO TEST FILTER CASK SECT. OF MDH SYS.

Nf 801030 085467 E30C001 AFHS SYS & TKS DECON 3 CN 0.000 6.70 STAND RECOMBINER UPRIGHT i

801031 085479 E30C001 AFHB SYS & TMS DECON 2 CR 0.000 2.00 DRAIN RECOMBINEP 801106 085519 E30C001 AFHS SYS & TKS DECON 2 CR 0.020 4.00 DECON RECOM81NER & GENERAL AREA 801129 0B5715 E30C001 AFHB SYS & TKS DECON 1 CN 0.003 1.58 REPLACE FILTER WDG-f-1 2801129 085715 E30C001 AFHB SYS & TKS DECON 1 OP 0.000 0.67 REPLACE FILTER WDG-F-1 2801129 085715 E30C001 AFHS SYS & TKS DECON 1 MM 0.005 1.33 REPLACE FILTER WDG-F-1

  • 801129 085715 E30C001 AFHB SYS & TKS DECON 2 UM 0.015 2.67 REPLACE FILTER WDG-F-1 801204 0B5768 E30J001 SYS & TKS RX DECON 7 CN 0.113 34.00 MOVE RECOMBINER TO RECEIVING DOCK 801205 085776 E30J001 SYS & TKS RX DECON 4 CN 0.013 24.08 MOVE RECOMBINER 70 RECEIVING DOCK 801217 085939 E30A001 RCS DECONTAMINATION 2 CN 0.010 2.33 RCS SAMPLE / RESIN COL TEST WITH ZEOLITE
  • 801217 085939 E30A001 RCS DECONTAMINATION 1 CR 0.005 1.17 RCS SAMPLE / RESIN COL TEST WITH ZE0 LITE 801218 085948 E30A001 RCS DECONTAMINATION 1 CN 0.005 0.50 RESIN COLUMN TEST WITH RCS & ZEOLITE
  • 801218 085948 E30A001 RCS DECONTAMINATION 1 CR 0.000 0.50 RESIN COLUMN TEST WITH RCS & ZEOLITE 801219 085960 E30A001 RCS DECONTAMINATION 1 CN 0.005 0.58 RESIN COLUMN TEST WITH RCS & ZEOLITE
  • 801219 085960 E30A001 RCS DECONTAMINATION 1 CR 0.000 0.58 RESIN COLUMN TEST WITH RCS & ZE0 LITE 810113 000093 E30040A MAKEUP FILTERS DECON 2 CN 0.007 2.08 DECON FTS/ MOVE FTS TO MODEL RDOM 8810113 000093 E30D40A MAMEUP FILTERS DECON 1 CR 0.010 2.00 DECON FTS/ MOVE FTS TO MODEL ROOM
  • 810113 000093 E30040A MAKEUP FILTERS DECON 1 EL 0.010 2.00 DECON FTS/ MOVE FTS TO MODEL ROOM 810223 000526 E30D056 RCBT B&C DECON 2 OP 0.175 1.00 VALVE LIhEUP DN *B' BLEED TANK
  • 810223 000526 E300056 RC87 B&C DECON 1 HP 0.060 0.50 VALVE LINEUP DN *B' BLEED TANK 810225 000558 E30040A MAKEUP FILTERS DECON 2 CN 0.015 3.17 MOCK RUN-REMOVAL OF MU FILTERS 2A.28 58
  • 810225 000558 E30D40A MAKEUP FILTERS DECON 2 CR 0.008 2.33 POCK RUN-REMOVAL OF HU FILTERS 2A.28.58
  • 810225 000558 E30D40A MAKEUP FILTERS DECON 12 MM 0.120 17.67 MOCK RUN-REMOVAL OF MU FILTERS 2A.28.58 810228 000577 E30040A MAKEUP FILTERS DECON 1 CN 0.025 4.32 REMOVE & PKG MU FILTERS 2A. 28 & 58
  • 810228 000577 EJ0040A MAKEUP FILTERS DECON 1 CR 0.020 4.02 REMOVE & PKG MU FILTERS 2A. 28. & 58 2810228 000577 E30040A MAKEUP FILTERS DECON 1 HP 0.015 4.27 REMOVE & PKG MU FILTERS 2A, 2B, & 5B
  • 810228 000577 E30D40A MAKEUP FILTERS DECON 6 MM 0.152 23.29 REMOVE & PKG MU FILTERS 2A. 28. & 58

.-m d

DATE 021886 PAGE 4

PNO.

3

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 2860

.EXP TRCK.

.PERS

. DEPT.E XPOS.RWP

  • DA T E... NUMB.E.R. N.UMB.E.R............ C. T I V I T. Y........,....... E. N T R G... C. O.D. E... R E.M..... H. O. U. R S...

A

...sese.......T.ASK DESCRIPTI.ONmeessen.............

  • e..........

essesse...

810304 000621 E30040A MAKEUP FILTERS DECON 2 CN 0.020 4.00 OBTAIN SAMPLES / GEN CLEANUP / PHOTOGRAPHS.

$810304 000621 E30040A MAKEUP FILTERS DECON 1 CR 0.017 2.00 OBTAIN SAMPLES / GEN CLEANUP / PHOTOGRAPHS 810309 000646 E30040A MAKEUP FILTERS DECON 2 CN 0.015 3.00 WET VAC AND GENERAL DECON 810320 000726 E30040A MAKEUP FILTERS DECON 1 CN 0.000 0.33 PREJOB SITING & PHOTOGRAPHS OF MU-F-AA/B

  • 810320 000726 E30D40A MAKEUP FILTERS DECON 1 CR 0.002 0.33 PREJOB SITING & PHOTOGRAPHS OF MU-F-AA/B 810601 001171 E30D40A MAKEUP FILTERS DECON 2 CN 0.017 3.92 STAGE AREA FOR FILTER REMOVAL 2810601 001171 E30D40A MAKEUP FILTERS DECON 2 CR 0.010 3.75 STAGE AREA FOR FILTER REMOVAL
  • 810601 001171 E30040A MAKEUP FILTERS DECON 1 AD 0.010 1.75 STAGE AREA FOR FILTER REMOVAL
  • 810601 001171 E30040A MAKEUP FILTERS DECON 2 UM 0.005 3.75 STAGE AREA'FOR FILTER REMOVAL 810814 001705 E300056 RCBT R&C DECON 6 MM 0.105 7.42 INSTALL ADAPTERS-WOL V-153A. 1538, 18A 2810814 001705 E300056 RCBT B&C DECON 1 CN 0.010 1.25 INSTALL ADAPTERS-WOL V-153A. 1538 18A 810817 001728 E30D057 RCST A DECON 3 CN 0.025 4.17 CONNECT HOSES / PUMP & FLUSH RCBT
  • A' 2810817 001728 E30D057 RCBT A DECON 12 OP 0.134 29.75 CONNECT HOSES / PUMP & FLUSH RCBT

'A' 810818 001732 E30D056 RCBT B&C DECON 10 CN 0.190 19.90 GAMMA SPEC SURVEY OF TANK SLUDGE

  • 810818 001732 E300056 RCST B&C DECON 1 CR 0.025 2.75 GAMMA SPEC SURVEY OF TANK SLUDGE 3810818 001732 E30D056 RCST B&C DECON 1 QA 0.000 0.33 GAMMA SPEC SURVEY OF TANK SLUDGE 810818 001734 E30D056 RCBT B&C DECON 1 CN 0.045 1.42 DRAIN SIGHT GLASS TO REDUCE HOT SPOT
  • 810818 001734 E30D056 RCBT B&C DECON 1 OP 0.045 2.67 DRAIN SIGHT GLASS TO REDUCE HOT SPOT 810821 001766 E30D056 RCBT B&C DECON 2 CN 0.025 2.83 DRAIN LOWER LEVEL SIGHT GLASS
  • 810821 001766 E30D056-RCBT B&C DECON 1 OP 0.010 2.00 DRAIN COWER LEVEL SIGHT GLASS Pc 810822 001772 E30D056 RCBT B&C DECON 1 CN 0,005 1.00 RMVE ADPTR FLNGE/ CONN LNS-WDL-V-18A.8,C C) 2810822.001772 E30D056 RCBT B&C DECON 1 OP 0.005 1.08 RMVE ADPTR FLNGE/ CONN LNS-WDL-V-18A.B.C e
  • 810822 001772 E30D056 RCBT B&C DECON 2 MM 0.040 2.00 RMVE ADPTR FLNGE/ CONN LNS-WDL-V-18A.8,C 310924 002086 E30D057 RCBT A DECON 1 ME 0.000 0.40 DISCON TEMP SAMP SYS AT WDL-18A,B.C

.*810924 002086 E30D057 RCBT A DECON 3 MM 0.015 3.73 DISCON TEMP SAMP SYS AT WDL-18A.B.C 810930 002093 E300057 RC8T A DECON 2 CN 0.013 3.67 FLUSH RCBT

'A' 3810930 002093 E30D057 RCST A DECON 5 OP 0.042 22.58 FLUSH RCBT

'A' 810930 n02096 E30D057 RC87 A DECON 1 CN 0.035 1.00 REMOVE TK MANWAY COVER / GASKET & REPLACE

  • 810930 002096 E30D057 RCBT A DECON 1 OP 0.020 2.00 REMOVE TK MANWAY COVER / GASKET & REPLACE
  • 810930 002096 E30D057 RCBT A DECON 1 HP 0.030 3.00 REMOVE TK MANWAY. COVER / GASKET & RE PLACE 2810930 002096 E30D057 RCBT A DECON 1 ME 0.060 1.00 REMOVE TK MANWAY COVER / GASKET & REPLACE
  • 810930 002096 E30D057 RCBT A DECON 3 MM 0.100 6.00 REMOVE TK MANWAY COVER / GASKET & REPLACE 811001 002102 E30D357.RCBT A DECON 2 CN 0.070 2.07 SAMPLE & SURVEY TANK INTERNALS 2811001 002102 E30D057 RCBT A DECON 1 CR 0.020 0.87 SAMPLE & SURVEY TANK INTERNALS
  • 811001 002102 E300057 RCBT A DECON 1 MM 0.040 1.12 SAMPLE & SURVEY TANK INTERNALS 811002 002106 E30D057 RCBT A DECON 3 CN 0.090 7.78 VACUUM & FLUSH RCBT

'A' 2811002 002106 E300057 RCBT A DECON 4 CR 0.095 11.37 VACUUM & FLUSH RCBT

  • A'
  • 811002 002106 E300057 RCBT A DECON 1 ES 0.060 3.35 VACUUM & FLUSH RCBT

'A'

  • 811002 002106 E300057 :RCBT A DECON 2 MM 0.070 5,68 VACUUM & FLUSH RCST

'A' 2811002 002106 E30D057 RCBT A DECON 2 UM 0.055 5.68 VACUUM & FLUSH RCST

  • A *
  • 811002 002106 E30D057 RCBT A DECON 1 OP 0.010 2.33 VACUUM & FLUSH RCBT
  • A'
  • 811002 002106 E300057 RCBT A DECON 1 HP 0.040 2.33 VACUUM & F LUSH RCBT

'A' 811007 002137 E30D057 RCBT A DECON 6 CN 0.105 12.67 SPARGE & FLUSH RC8T

  • A' 2811007 002137 E300057 RCBT A DECON 11 CR 0.261 24.67 SPARGE & FLUSH RC87

'A'

  • 811007 002137 E30D057 RCST A DECON 6 MM 0.192 15.83 SPARGE & FLUSH RCBT
  • A' 1811007 002137 E300057-RCBT A DECON 6 UM 0.037 15.00 SPARGE & FLUSH RCBT

'A'

  • 811007 002137 E30D057 RCBT A DECON 4 OP

,0.028 8.08 SPARGE & FLUSH RCST

'A'

  • 811007 002137 E300057 RCBT A DECON 4 HP 0.080 8.58 SPARGE & FLUSH RCBT

'A' 811010 002153 E300057 RCBT A DECON 1 CN 0.020 1.50 REPLACE MANWAY COVER & GASKET

  • 811010 002153 E300057 RCBT A DECON 1 OP 0.020 2.50 REPLACE MANWAY COVER & GASKET

DATE 021886 PAGE 5

PNO.

4

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 2860

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • .................................I.VITY.................................. REM........ HOURS.........===...................IPTION
  • DATE. NUMBER. NUMBER ACT

.ENTRG CODE TASK DESCR

...ee......sessesse=====.

  • 811010 002153 E30D057 RC8T A DECON 3 MM 0.075 5.25 REPLACE MANWAY COVER & GASKE T 811019 002200 E30D057 RC8T A DECON 1 CN 0.010 2.50 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE
  • 811019 002200 E300057 RC8T A DECON 2 CR 0.010 4.75 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE
  • 811019 002200 E30D057 RCBT A DECON 1 HP 0.010 2.50 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE
  • 811019 002200 E300057 RCBT A DECON 2 UM 0.005 4.75 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE 811019 002210 E30D057 RCBT A DECON 2 CN 0.005 1.33 SAMPLE RCBT

'A* AT SANDPIPER PUM'

  • 811019 002210 E30D057 RCBT A DECON 2 OP 0.000 2.08 SAMPLE RCBT

'A' AT SANDPIPER PUMP 820127 002923 E30E33A PWST DECON 6 UM 0.010 20.16 REMOVE PLASTIC & SCAFFOLD TENT AT PWST

  • 820127 002923 E30E33A PWST DECON 2 HP 0.010 10.00 REMOVE PLASTIC & SCAFFOLD TENT AT PWST
  • 820127 002923 E30E33A PWST DECON 1 RW 0.008 3.67 REMOVE PLASTIC & SCAFFOLD TENT AT PWST 820210 003007 E30D40A MAKEUP FILTERS DECON 1 MM 0.010 0.75 WEIGH DRUM CONTAINING MU FILTER 2B 2820210 003007 E30040A MAKEUP FILTERS DECON 2 UM 0.005 1.50 WEIGH DRUM CONTAINING MU FILTER 2B
  • 820210 003007 E30D40A MAKEUP FILTERS DECON 1 HP 0.008 0.83 WEIGH DRUM CONTAINING MU FILTER 28 820222 003096 E30040A MAKEUP FILTERS DECON 1 DM 0.005 1.08 CHK FOR HYDROGEN / SECURE LEAD LINER LID 1820222 003096 E30D40A MAKEUP FILTERS DECON 1 AD 0.005 1.00 CHK FOR HYDROGEN / SECURE LEAD LINER LID
  • 820222 003096 E30D40A MAKEUP FILTERS DECON 1 CR 0.010 1.33 CHK FOR HYDROGEN / SECURE LEAD LINER LID 2820222 003096 E30D40A MAKEUP FILTERS DECON 1 UM 0.010 1.08 CHK FOR HYDROGEN / SECURE LEAD LINER LIO
  • 820222 003096 E30D40A MAKEUP FILTERS DECON 1 HP 0.005 1.00 CHK FOR HYDROGEN / SECURE LEAD LINER LID 820226 003399 E300056 RCBT B&C DECON 1 CM 0.005 1.67 SAMPLE RC BLEED TANK

'C' pb

  • 820226 003399 E30D056 RC8T B&C DECON 1 CH 0.000 1.83 SAMPLE RC BLEED TANK

'C' 820317 003313 E30040A MAKEUP FILTERS DECON 3 HP 0.015 4 50 RMVE 28,5A&58 PLUGS / STAGE FOR FLTR PULL

_a i

  • 820317 003313 E30040A MAKEUP FILTERS DECON 7 UM 0.020 8.75 RMVE 28.5A&58 PLUGS / STAGE FOR FLTR PULL
  • 820317 003313 E30D40A MAKEUP FILTERS DECON 1 OP 0.000 1.00 RMVE 28.5A&SB PLUGS / STAGE FOR FLTR PULL
  • 820317 003313 E30D40A MAKEUP FILTERS DECON 2 CR 0.000 2.83 RMVE 28.5A&5B PLUGS / STAGE FOR FLTR FULL
  • 820317 003313 E30D40A MAKEUP FILTERS DECON 1 CN 0.000 1.00 RMVE 28.5A&58 PLUGS / STAGE FOR FLTR PULL 820320 003331 E30040A MAKEUP FILTERS DECON 3 CN 0.023 9.00 OBTAIN SPEC MEASUREMENTS FROM MU FILTERS 2820320 003331 E30040A MAKEUP FILTERS DECON 1 CR 0.008 3.17 OBTAIN SPEC MEASUREMENTS FROM MU FILTERS
  • 820320 003331 E30D40A MAKEUP FILTERS DECON 1 CH 0.007 1.00 OBTAIN SPEC MEASUREMENTS FROM MU FILTERS 820322 003332 E30D40A MAKEUP FILTERS DECON 1 EG 0.003 0.42 PULL 4A & 4B FILTERS / VACUUM HOUSINGS
  • 830322 003332 E30040A MAKEUP FILTERS DECON 5 HP 0.185 15.50 PULL 4A & 48 FILTERS / VACUUM HOUSINGS 2830322 003332 E30D40A MAKEUP FILTERS DECON 12 UM 0.372 32.66 PULL 4A & 48 FILTERS / VACUUM HOUSINGS 2830322 003332 E30040A MAKEUP FILTERS DECON 2 CR 0.095 6.00 PULL 4A & 48 FILTERS / VACUUM HOUSINGS
  • 830322 003332 E30D40A MAKEUP FILTERS DECON 4 CN 0.090 12.17 PULL 4A & 48 FILTERS / VACUUM HOUSINGS 820322 003352 E30040A MAKEUP FILTERS DECON 2 OP 0.229 2.25 ISOLATE MU FILTER 4A
  • 820322 003352 E30D40A MAKEUP FILTERS DECON 1 HP 0.000 1.08 ISOLATE MU FILTER 4A
  • 830322 003352 E30D40A MAKEUP FILTERS DECON 2 CN 0.220 1.92 ISOLATE MU FILTER 4A 820323 003362 E30D057 RCBT A DECON 2 CN 0.020 5.25 FLUSH & SAMPLE RCBT

'A' 2820323 003362 E300057 RCBT A DECON 1 CH 0.005 2.33 FLUSH & SAMPLE RCBT

'A'

  • 820323 003362 E300057 RCBT A DECON 3 OP 0.043 9.33 F LUSH & SAMPLE RC8T

'A'

  • 820323 003362 E300057 RCST A DECON 1 HP 0.010 2.75 FLUSH & SAMPLE RCBT

'A' 820324 003364 E30D40A MAKEUP FILTERS DECON 5 UM 0.065 8.34 PULL MU FILTERS 2A & SB

  • 820324 003364 E30D40A MAKEUP FILTERS DECON 1 CN 0.010 2.00 PULL MU FILTERS 2A & 58 2820324 003364 E30040A MAKEUP FILTERS DECCN 1 CR 0.020 1.58 PULL MU FILTERS 2A & 58 2820324 003364 E30040A MAKEUP FILTERS DECON 1 HP 0.010 2.00 PULL MU FILTERS 2A & 58 820324 003384 E30D40A MAKEUP FILTERS DECON 8 UM 0.455 17.91 VAC 2A.28.5A.58 MUF HOUSINGS AND FLOOR 2820324 003384 E30D40A MAKEUP FILTERS DECON 4 CR 0.155 9.67 VAC 2A,28.5A 58 MUF HOUSINGS AND FLOOR 3820324 003384 E30D40A MAKEUP FILTERS DECON 1 CN 0.050 3.00 VAC 2A.28.5A.58 MUF HOUSINGS AND FLOOR
  • 820324 003384 E30D40A MAKEUP FILTERS DECON 2 HP 0.100 5.17 VAC 2A.28.5A.5B MUF HOUSINGS AND FLOOR 820328 003405 E30D057 RCBT A DECON 1 CN 0.030 3.67 RECIRC RC8T ' A'/SAMP & DISCONNECT HOSES
  • 820328 003405 E300057 RCBT A DECON 1 OP 0.022 4.08 RECIRC RCBT ' A'/SAMP & DISCONNECT HOSES

.m

.m

.4-

, i

?

DATE 021886 PAGE 6

PNO.

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS,RWP

  • D. A TE... N. UMB. E.R.. NUMB.E.R............ C. T. I. V I. T. Y....... q........ E.N T RG. C.O.D.E... R E.M.... H. O.U.R S................... T A S.K D.E. S.C.R I P T. ION A

3.33 SAMPLE & ANALYZE RCS & RCBT

  • C' 820329 003409 E300056 RCBT B&C DECON 1 CN 0.010
  • 820329 003409 E300056 RCBT B&C DECON 1 CH 0.005 3.33 SAMPLE & ANALYZE RCS & RCBT

'C' 320331 003453 E30D056 RCBT B&C DECON 1 CN 0.005 1.33 SAMPLE RCBT

'C' 2820331 003453 E30D056 RCBT B&C DECON 1 CH 0.000 1.17 SAMPLE RCBT 'C"

  • 820331 003453 E300056 RCBT B&C DECON 1 HP 0.005 1.33 SAMPLE RCBT

'C' 820331 003434 E300057 RCBT A DECON 1 CN 0.065 3.42 REMOVE DRUMS FROM RCBT */ */ PUMP TO CWT 2820331 003434 E300057 RCBT A DECON 4 CR 0.110 10.00 REMOVE DRUMS FROM RCBT 'A'/ PUMP TO CWT 2820331 003434 E30D057 RCBT A DECON 1 MM 0.020 1.00 REMOVE DRUMS FROM RCBT 'A*/ PUMP TO CWT 2820331 003434 E300057 RCST A DECON 2 UM

'0.055 5.50 REMOVE DRUMS FROM RCBT 'A*/ PUMP TO CWT

  • 820331 003434 E30D057 RCBT A DECON 1 HP 0.025 2.67 REMOVE DRUMS FROM RCBT 'A*/ PUMP To CWT 820408 003514 E30A001 RCS DECONTAMINATION 2 CN 0.000 2.00 REMOVE RCS CNTRL PANEL SUPPORTS & MODIFY 820412 003530 E30A001 RCS DECONTAMINATION 7 CN 0.03b 11.00 PULL CABLE /RUN CONDUIT-RCF V-4 L V-9 820412 003531 E30A001 RCS DECONTAMINATION 11 CN 0.008 17.75 PULL CABLE /RUN CONDUIT-301 A PANEL 820413 003548 E30A001 RCS DECONTAMINATION 13 CN 0.264 44.22 INSTL FLANGE & SPECTACLE BLIND IN 2'WDL
  • 820413 003548 E30A001 RCS DECONTAMINATION 2 HP 0.037 8.08 INSTL FLANGE & SPECTACLE BLIND IN 2'WOL 820415 003586 E30A001 RCS DECONTAMINATION 2 IC 0.003 1.67 RUN COAXIAL CABLE FOR SAM HOOKUP
  • 820415 003586 E30A001 RCS DECONTAMINATION 1 CN 0.005 2.67 RUN C0 AXIAL CABLE FOR SAM HOOKUP 820419 003603 E30A001 RCS DECONTAMINATION 1 CH 0.010 2.50 PULL CABLE /RUN CONDUIT-RCF V-4 & V-9
  • 820419 003603 E30A001 RCS DECONTAMINATION 6 CN 0.053 13.95 PULL CABLE /RUN CONDUIT-RCF V-4 & V-9 820427 003687 E30A001 RCS DECONTAMINATION 11 CN 0.063 21.75 INSTL T'VLVES/RUN TUBES TO A62-AN,A64-AR a
  • 820427 003687 E30A001 RCS DECONTAMINATION 3 HP 0.005 4.42 INSTL T VLVES/RUN TUBES TO A62 AN. A64-AN 820427 003688 E30A001 RCS DECONTAMINATION 11 CN 0.060 17.15 INSTALL AIR LINES / HOOK UP SANDPIPER PUMP
  • 820427 003688 E30A001 RCS DECONTAMINATION 2 OP 0.005 3.08 INSTALL AIR LINES / HOOK UP SANDPIPER PUMP
  • 320427 003688 E30A001' RCS DECONTAMINATION 1 HP 0.010 3.00 INSTALL AIR LINES / HOOK UP SANDPIPER PUMP 820428 003706 E30A001 RCS DECONTAMINATION 2 CN 0.020 6.75 INSTALL TEMP N-2 SYSTEM IN TEST TK AREA 2820428 003706 E30A001 RCS DECONTAMINATION 2 CR 0.005 2.67 INSTALL TEMP N-2 SYSTEM IN TEST TK ARE4
  • 820428 003706 E30A001.RCS DECONTAMINATION-11 MM 0.115 21.33 INSTALL TEMP N-2 SYSTEM IN TEST TK AREA 2820428 003706 E30A001 RCS DECONTAMINATION 1 OP 0.000 0.42 INSTALL TEMP N-2 SYSTEM IN TEST TK AREA 820428 003709 E30A001 RCS DECONTAMINATION.

7 CN 0.148 14.75 INSTALL TEE IN SAMPLE LINE SN18

  • 820428 003709 E30A001 RCS DECONTAMINATION 3 HP 0.042 4.73 INSTALL TEE IN SAMPLE LINE $N18 820428 003708 E30C001 AFHB SYS & TKS DECON 1 CN 0.015 2.67 GAMMA SPEC ANALYSIS OF MU TANK & PIPING
  • 820428 003708 E30C001 AFHB SYS & TKS DECON 1 CR 0.020 2.67 GAMMA SPEC ANALYSIS OF MU TANK & PIPING 820504 003762 E30A001 RCS DECONTAMINATION 20 CN 0,349 55.71 HYDROTEST RCS PIPE / REPAIR LEAKS
  • 820504 003762 E30A001 RCS DECONTAMINATION 2 CM 0.000 1.50 HYDROTEST RCS PIPE / REPAIR LEAKS 2820504 003762 E30A001 RCS DECONTAMINATION 3 ES 0.035 6.92-HYDROTEST RCS PIPE / REPAIR LEAKS
  • 820504 003762 E30A001 RCS DECONTAMINATION 1 HP 0.010 1.33 HYDROTEST RCS PIPE / REPAIR LEAKS 2820504 003762 E30A001 RCS DECONTAMINATION

- 5 CA 0.058 10.00 HYDROTEST RCS PIPE / REPAIR LEAKS 28?0504 003762 E30A001 RCS DECONTAMINATION 1 CR 0.005 1.67 HYDROTEST RCS PIPE / REPAIR LEAKS 820506 003786 E30A001 RCS DECONTAMINATION 3 CN 0.035 3.67 ADJUST LIMIT SWITCHES-EVAP COND TK RM

  • 820506 003786 E30A001 RCS DECONTAMINATION 1 CA 0.010 0.75 ADJUST LIMIT SWITCHES-EVAP COND TK RM 320512 003331 E30A001 RCS DECONTAMINATION 14 CN 0.300 28.42 INSTALL HANGERS / ANCHOR
  • 820512 003831 E30A001 RCS DECONTAMINATION 1 HP 0.035 2.17 INSTALL HANGERS / ANCHOR
  • 820512 003831 E30A001 RCS DECONTAMINATION

'l 05 0.020 1.08 INSTALL HANGERS / ANCHOR 820512 003832 E30A001 RCS DECONTAMINATION 1 CN 0.075 1.33

' REMOVE HYCR0 PUMP & HOSES /CEN CLEANUP 820513 003838 E30A001 RCS DECONTAMINATION 1 OP 0.010 1.50 VALVE LINEUP FOR RCS PROCESSING

  • 820513 003838 E30A001 RCS DECONTAMINATION 1 HP 0.010 1.50 VALVE LINEUP FOR RCS PROCESSING 820513 003852 E30A001 RCS DECONTAMINATION 1 CN 0.005 1.83 VERIFY RCS PROCESSING FLOW
  • 820513 003852 E30A001 RCS DECONTAMINATION 2 OP 0.020 3.42 VERIFY RCS PROCESSINMG FLOW 2820513 003852 E30A001 RCS DECONTAMINATION 1 ES 0.010 1.67 VERIFY RCS PROCESSING FLOW 320519 003898 E30C001 AFHB SYS & TKS DECON 2 CN-0.075 4.50 GAMMA SCAN OF SEAL RETURN COOLER & MUF-3

DATE 021886 PAGE 7

PNO.

6

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • DA TE... NU.MBE.R. NUMB.E.R............C. T I.VI. T Y A

................E.NTRG........C O.D.E... R E.M..... HOURS.._..............T. AS.K..D.E.SCR I.P TI.ON...................

1 CR 0.040 2.17.

GAMMA SCAN OF SEAL RETURN COOLER & MUF-3

  • 820519 003898 E30C001 AFHB SYS & TKS DECON 820706 004220 E30C001 AFHB SYS & TKS DECON 1 UM 0.000 1.67 DECON FLOOR & WALL
  • 820706 004220 E30C001 AFHB SYS & TKS DECON 1 HP 0.000 1.33 DECON FLOOR & WALL 820707 004224 E30E33% PWST DECON 7 DM 0.005 19.58 REMOVE CONTAMINATED SOIL
  • 820707 004224 E30E33A PWST DECON 3 HP 0.005 11.00 REMOVE CONTAMINATED SOIL 820909 004687 E30C001 AFHB SYS & TMS DECON 1 CN 0.030 2.17 GAMMA SCAN OF BLOCK ORIFICE IN MUV ROOM 2820909 004687 E30C001 AFHB SYS & TKS DECON 1 HP 0.015 2.17 GAMMA SCAN OF BLOCK ORIFICE IN MUV ROOM 3820909 004687 E30C001 AFHB SYS & TKS DECON 1 CR 0.018 2.25 GAMMA SCAN OF BLOCK ORIFICE IN MUV ROOM 820913 004693 E30C001 AFHB SYS & TKS DECON 5 UM 0.020 8.75

- INSTALL H AMP IN CORRIDOR TO MUV ROOM 3820913 004693 E30C001 AFHB SYS A TKS DECON 1 HP 0.000 2.33 INSTALL RAMP IN CORRIDOR TO MUV ROOM 871202 005221 E30H001 OTSG B DECON 3 CN 0.001 17.08 FLUSH OTSG LINES-M-20 AREA 821202 005222 E30H001 OTSG B DECON 7 CN 0.080 44.77 TIE-IN OTSG NEW PIPE TO OLD PIPE 821217 005355 E300057 RCBT A DECON 5 CN 0.045 8.37 REMOVE E001P FROM RCBT ' A' ROOM

  • 821217 005355 E30D057 RCBT A DECON 1 HP 0.010 1.10 REMOVE EQUIP FROM RCBT

'A' ROOM 830105 005486 E30H001 OTSG B DECON 2 OP 0.000 2.33 MOVE CONTAM MATL-SDS AREA TO TURB BLDG 830105 005487 E30H001 OTSG B CECON 2 OP 0.000 0.97 MOVE SANDPIPER TO TURBINE BLDG 830107 005504 E30H001 OTSG B DECON 1 CM 0.000 1.20 PUMP OTSG A MAIN STEAM LINES TO CDT SUMP

830110 005530 E30H001 OTSG B DECON 4 OP 0.000 17.81 PUMP OTSG

'A' STEAM & FEED LINES TO CDT hJ

  • 830110 005530 E30H001 OTSG B DECON 1 RP 0.000 8.12 PUMP OTSG

'A' STEAM & FEED LINES TO CDT LJ 830112 005548 E30H001 OTSG B DECON 13 OP 0.004 67.03 SET UP & OPERATE OTSG CLEANUP SYSTEM

  • 830112 005548 E30H001 OTSG B DECON 3 MM 0.002 11.45

' SET UP & OPERATE OTSG CLEANUP SYSTEM

  • 830112 005548 E30H001 OTSG B DECON 2 HP 0.000 7.65 SET UP & OPERATE OTSG CLEANUP SYSTEM
  • 830112 005548 E30H001 OTSG B DECON 2 CM 0.000 4.57 SET UP & OPERATE OTSG CLEANUP SYSTEM 3830112 005548 E30H001 OTSG B DECON 1 RP 0.000 2.00 SET UP & OPERATE OTSG CLE#NUP SYSTEM 830119 005619 E30H001 OTSG B DECON 3 OP 0.000 22.85 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 1830119 005619 E30H001 OTSG B DECON 1 MM 0.000 5.13 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 810119 005619 E30H001 OTSG B DECON 1 HP 0.005 6.57 SET UP/CPERATE/ TEAR DOWN OTSG B CU SYS
  • 830119 005619 E30H001 OTSG B DECON 2 CM 0.000 1.22 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 830120 005621 E30H001 OTSG B DECON 2 CN 0.215 1.87 OPERATIONAL CHECK OF OTSG
  • B* DRAIN VLVS 830121 005632 E30H001 OTSG B DECON 27 OP 0.005 157.C2 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830121 005632 E30H001 OTSG B DECON 12 HP 0.002 26.05 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830121 005632 E30H001 OTSG B DECON 7 MM O.002 32.30 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830121 005632 E30H001 OTSG B DECON 2 RP 0.000 10.52 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830121 005632 E30H001 OTSG B DECON 14 CM 0.005 12.95 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 7
  • 830121 005632 E30H001 OTSG B DECON 1 ES 0.000 6.48 SET UP/0PERATE/ TEAR DOEN OTSG B CU SYS 830128 005682 E30H001 GTSG B DECON 2 OP 0.005 9.75 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830123 005682 E30H001 OTSG B DECON 1 CM 0.000 0.82 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 830123 005689 E30H001 OTSG B OECON 8 MM 0.000 30.87 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 2830128 005689 E30H001 OTSG B DECON 11 OP 0,000 60.05 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830128 005689 E30H001 OTSG B DECON 5 HP 0.003 11.38 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830128 005689 E30H001 OTSG B DECON 2 CM 0.000 1.30 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 830202 005722 E30H001 OTSG B DECON 3 CN 0.749 5.75 DRAIN OTSG *B' SECONDARY SIDE

,i 830204 005742 E30H001 OTSG B DECON 2 CN 0.311 2.65 DRAIN OTSG

'B' SECONDARY SIDE 830109'005786 E30H001 OTSG B DECON 1 OP 0.000 1.00 INSTALL HOSE-ALC-P-1 INF TO ALC-9-4 EFF

  • 830209 005786 E30H001 OTSG B DECON 1 HP 0.005 1.00 INSTALL HOSE-ALC-P-1 INF TO ALC-P-4 EFF 830209 005787 E30H001' OTSG B DECON 22 OP 0.005 98.09 ORAIN DOWN OTSG B TO 327 ELEV VIA CU SYS 2830209 005787 E30H001 OTSG B DECON 13 CM 0.000 11.53 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS 3830209 005787 E30H001 OTSG B DECON 3 MM 0.002 12.02 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS

DATE 021886 PAGE 8

PNO 7

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • D. A T E... N UMB. E.R. NU.MB.E.R

........C. T I V I T. Y......

4...... E. N..T R G... C. O. D. E... R. E. M..... H. O. U. R S............... T. A. S. K..D. E. S. C. R I A
  • 83C209 005787 E30H001 OTSG B DECON

. 0.000.

5.63 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS, 1 RP 2830209 005787 E30H001 OTSG B DECON 5 HP 0.000 5.70 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS 830214 005814 E30H001 OTSG B DECON 4 CN 0.618 5.53 DRAIN OTSG

'B' TO SUMP 830216 005850 E30H001 DTSG B DECON 10 OP 0.005 27.11 DRAIN OTSG

'A'

'B' VIA 4X4 CLEANUP SYS

  • 830216 005850 E30H001 OTSG B DECON 3 CM 0.000 2,12 DRAIN OTSG

'A'

'B' VIA 4X4 CLEANUP SYS 2830216 005850 E30H001 OTSG B DECON 1 RP 0.000 3.97 DRAIN OTSG

'A'

'B' VIA 4X4 CLEANUP SYS

  • 830216 005850 E30H001 OTSG B DECON 3 HP 0.000 2.08 DRAIN OTSG

'A'

  • B' VIA 4X4 CLEANUP SYS 830223 005908 E30H001 OTSG B DECON 5 OP 0.000 10.45 DRAIN OTSG

'A'

  • B' VIA 4X4 CLEANUP SYS
  • 830223 005908 E30H001 OTSG B DECON 2 MM 0.000 2.28 DRAIN OTSG

'A'

'B' VIA 4X4 CLEANUP SYS

  • 830223 005908 E30H001 OTSG 8 DECON 1 HP 0.000 1.30 DRAIN OTSG

'A'

'B' VIA 4X4 CLEANUP SYS 830307 006002 E30H001 OTSG B DECON 9 OP 0.000 43.17 MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP

  • 830307 006002 E30H001 OTSG B DECON 1 RP 0.000 6.28 MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP
  • 830307 006002 E30H001 OTSG B DECON 1 CR 0.000 1.42 MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP
  • 830307 006002 E30H001 OTSG B DECON 1 HP 0.000 1.5C MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP 830322 006119 E30C001 AFHB SYS & TKS DECON 1 OP 0.007 3.00 RBAT-FLUSH WDS-T-3/ VALVE LINEUP FOR FLSH

$830322 006119 E30C001 AFHB SYS & TKS DECON 1 MM 0.008 2.97 RBAT-FLUSH WDS-T-3/ VALVE LINEUP FOR FLSH

  • 830322 006119 E30C001 AFHS SYS & TKS DECON 1 IC 0.00R 2.97 RBAT-FLUSH WDS-T-3/ VALVE LINEUP FOR FLSH 3830322 006119 E30C001 AFHB SYS & TKS DECON 1 CN 0.005 3.98 RBAT-FLUSH WDS-T-3/ VALVE LINEUP FOR FLSH 830329 006168 E30C001 AFHB SYS & TKS DECON 1 OP 0.005 0.00 FLUSH RBAT & ASSOCIATED PIPING
  • 830329 006168 E30C001 AFHB SYS & TKS DECON 1 MM 0.003 3.05 FLUSH RBAT & ASSOCIATED PIPING s

830405 006208 E30C001 AFHS SYS & TKS DECON 1 OP 0.000 1.02 REMOVE HOSES FROM DOOR OPENING hJ

  • 830405 006208 E30C001 AFH8 SYS & TKS DECON 1 HP 0.009 1.22 REMOVE HOSES FROM DOOR OPENING 45
  • 830405 006208 E347.001 AFHS SYS & TKS DECON 1 CM 0.000 1.18 REMOVE HOSES FROM DOOR OPENING 830421 006320 E30E33A PWST DECON 4 IC 0.003 18.27 DECON PROCESSED WATER STORAGE TANK 2830421 006320 E30E33A PWST DECON 2 MM 0.005 9.25 DECON PROCESSED WATER STORAGE TANK
  • 830421 006320 E30E33A PWST DECON 1 OP 0.000 6.35 DECON PROCESSED WATER STORAGE TANK 830502 006411 E300057 RCBT A DECON 1 CN 0.010 1.07 REMOVE & INSTALL MANWAY/ SCRAPE SAMPLES
  • 830502 006411 E30D057 RCBT A DECON 4 MM 0.080 8.00 REMOVE & INSTALL MANWAY/ SCRAPE SAMPLES
  • 830502 006411 E30D057 RCBT A DECON 1 HP 0.020 2.43 REMOVE & INSTALL MANWAY/ SCRAPE SAMPLES 830508 006455 E30C001 AFHB SYS & TF.S DECON 1 MM 0.000 1.22 INSTALL TEMP BALL VALVE 10DGIA 830713 006947 E30J001 SYS & TKS RX DECON 2 CN 0.000 1.38 MODIFY HANDRAIL & LEG ON PLATFORM 830725 007047 E30H001 OTSG B DECON 2 CN 0.000 1.98 RMVE WAX INSIDE GLV8X/DECON CASK & FLOOR 830818 007255 E30C001 AFHB SYS & TKS DECON 1 ES 0.003 0.67 PHOTOGRAPH 3 INCH RESIh FILL LINES 831018 007794 E30D056 RCBT BSC DECON 10 CM 0.006 46.38 RC8T RESIN TESTING 831018 007793 E30E33A PWST DECON 1 MM 0.000 1.48 DECON FLANGE IN PWST PUMP HOUSE
  • 831018 007793 E30E33A PWST DECON 1 OP 0.003 1.50 DECON FLANGE IN PWST PUMP HOUSE 831021 007803 E30D056 RCBT B&C DECON 4 CM 0.000 22.67 RCBT RESIN TESTING 831026 007831 E30E33A PWST DECON 3 IC 0.000 1.57 DECON INSTRUMENT EQUIPMENT 831027 007835 E30040A MAKEUP FILTERS DECON 5 UM 0.000 4.13 GAMMA SPEC MEASUREMENTS-MUF 28.5A 45B
  • 831027 007835 E30D40A MAKEUP FILTERS DECON 2 CN 0.002 7.85 GAMMA SPEC MEASUREMENTS-MUF 28.5A &58
  • 831027 007835 E30D40A MAKEUP FILTERS DECON 1 HP 0.002 4.22 GAMMA SPEC MEASUREMENTS-MUF 28.5A &58 831028 007839 E30E33A PWST DECON 16 IC 0.027 39.70 PREPARE TV CAMERAS / TEST EQUIPMENT
  • 831028 007839 E30E33A PWST DECON 3 HP 0.000 1.22 PREPARE TV CAMERAS / TEST EQUIPMENT 831103 007876 E30E33A PWST DECON 2 IC 0.000 3.60 EQUIPMENT DECON 840324 008700 E30H001 OTSG B DECON 2 MM 0.000 10.00 REMOVE MS-V-3A & 38 FROM SYSTEM 840404 008766 E30C001 AFHS SYS & TKS DECON 6 HP 0.420 15.32 FLUSH DECAY HEAT REMOVAL SYSTEM
  • 840404 008766 E30C001 AFHS SYS & TMS DECON 8 HP 0.572 20.20 FLUSH DECAY HEAT REMOVAL SYSTEM 840410 008802 E30C001 AFNB SYS & TKS DECON 2 HP 0.250 8.57 DRAIN & REFILL PUMP & COOLE R
  • 840410 008802 E30C001 AFNB SYS & TKS DECON 3 OP 0.493 12.97 DRAIN & REFILL PUMP & COOLER 840412 008814 E30A001 RCS DECONTAMINATION 3 HP 0.029 1.88 CHANGE SAM II AT

'C' BLEED TANK

._1.__.

_m.

, ~ ~ - - _. _

._m_

-m-

_.__m_

DATE 021886 PAGE

~9 4

PNO.

8

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D i

.RWP

.EXP TRCK.

......... E.N T R G..

C. O.D E... R E.M..... H O. U. R S...

.PERS

. DEPT. EXPOS.RWP

  • D. ATE.. NUMB.E.R. NUMB E.R............ T. IV I T. Y........

AC TASK DESCRIPTION ~

2.............

840412 008812 E30040A MAKEUP FILTERS DECON 8 UM 0.031 11.63 INSTL SCAF & LD BRICK-CEMENT BLK SHLDG 840421 008868 E30C001 AFHS SYS & TKS DECON 2 OP 0.067 2.80 FLUSH

'B' DECAY HEAT LOOP

  • 840421 008868 E30C001 AFHB SYS & TKS DECON 1 CN 0.042 1.50 FLUSH

'B' DECAY HEAT LOOP 840828 009801 E30D40A MAKEUP FILTERS DECON 5 CN 0.009 8.95 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM

  • 840828 003801 E30D40A MAKEUP FILTERS DECON 2 ES 0.005 7.58-PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30040A MAKEUP FILTERS DECON 3 CA 0.000 2.05 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30040A MAKEUP FILTERS DECON 3 EL 0.004 2.97 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30D40A MAKEUP FILTERS DECON 11 MM 0.019 13.72 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM j

2840828 009801 E30040A MAKEUP FILTERS DECON 2 HP 0.005 9.18 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM

  • 840828 009801 E30040A MAKEUP FILTERS DECON 2 IC 0.005 4.40 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30D40A MAKEUP FILTERS DECON 1 OP 0.000 5.03 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM t

e 840828 008691 E30H001 OTSG B DECON 1 OP

.0.003 1.37 REMOVE INSULATION & DECON PIPING na

  • 840323 008691 E30H031 0'SG B DECON 2 CN 0.007 2.25 REMOVE INSULATION & DECON PIPING um
  • 840323 008691 E30H001 OTSG B DECON 1 EL 0.000 0.95 REMOVE INSULATION & DECON PIPING.

e

  • 840323 008891 E30H001 OTSG B DECON 1 UM 0,002 1.35 REMOVE INSULATION & DECON PIPING 841215 010481 E30C001 AFHB SYS & TKS DECON 2 OP 0.140 4.48 FLUSH FLOORS, WALLS AND EQUIP-FHB 281'
  • 841215 010481 E30C001 AFHB SYS & TKS DECON 1 RP 0.078 2.28 FLUSH FLOORS, WALLS AND EQUIP-FHB 281*
  • 841215 010481 E30C001 AFHB SYS & TKS DECON 1 CN 0.060 3.28 FLUSH FLOORS, GAL OF RCS THRU BORONOMETER WALLS AND EQUIP-FHB 281' 841219 010518 E30A001 RCS DECONTAMINATION 1 HP 0.008 4.80 LET DOWN 100 841219 010518 E30A001 RCS DECONTAMINATION 1 CM 0.005 2.13 LET DOWN 100 GAL OF RCS THRU BORONOMETER 841219 010518 E30A001 RCS DECONTAMINATION 1.EG 0.003 5.47 LET DOWN 100 GAL OF RCS THRU BORONOMETER 841219 010518 E30A001 RCS DECONTAMINATION 1 OP 0.007

~5.63 LET DOWN.100 GAL OF RCS THRU BORONOMETER

. GRAND-TOTAL PERS ENTRG. 1075 1

. EXPOS : REM 14.740000

. RWP HOURS. 2552.5300

..... END REPORT 2-m

'h i

_m._

I 4.0 COMPUTER REPORTS 4.4 TMI-2 RCS and Systems Decontamination Individual Activity Summaries

. J

DATE 021886 PAGE 2

PNO.

1

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

_EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • DATE...huMBER. NUMBER... s e e m s..... T. Y...

.p........ =....... CODE. REM.=====.smassa.

s===... messes.ames==s.. eses==sesseme=========s======.

ACTIVI

.ENTRG

. HOURS TASK DESCRIPTION

.ss......

seems.

801217 085939 E30A001 RCS DECONTAMINATION 2 CN 0.010 2.33 RCS SAMPLE / RESIN COL TEST WITH ZEOLITE

  • 801217 085939 E30A001 RCS DECONTAMINATION 1 CR 0.005 1.17 RCS SAMPLE / RESIN COL TEST WITH ZEOLITE 801218 085948 E30A001 RCS DECONTAMINATION 1 CN 0.005 0.00 RESIN COLUMN TEST WITH RCS & ZEOLITE
  • 801218 085948 E30A001 RCS DECONTAMINATION 1 CR 0.000 0.50 RESIN COLUMN TEST WITH RCS & ZEOLITE 801219 085960 E30A001 RCS DECONTAMINATION 1 CN 0.005 0.58 RESIN COLUMN TEST WITH RCS & ZEOLITE
  • 801219 085960 E30A001 RCS DECONTAMINATION 1 CR 0.000 0.58 RESIN COLUMN TEST WITH RCS & ZEOLITE 820408 003514 E30A001 RCS DECONTAMINATION 2 CN 0.000 2.00 REMOVE RCS CNTRL PANEL SUDPORTS & MODIFY

.820412 003530 E30A001 RCS DECONTAMINATION 7 CN 0.038 11.00 PULL CABLE /RUN CONDUIT-RCF V-4 & V-9 820412 003531 E30A001 RCS DECCNTAMINATION 11 CN 0.008 17.75 PULL CABLE /RUN CONDUIT-301 A PANEL 820413 003548 E30A001 RCS DECONTAMINATION 13 CN 0.264 44.22 INSTL FLANGE & SPECTACLE BLIND IN 2'WDL

  • 820413 003548 E30A001 RCS DECONTAMINATION 2 HP 0.037 8.08 INSTL FLANGE & SPECTACLE BLIND IN 2'WDL 820415 003586 E30A001 RCS DECONTAMINATION 2 IC 0.003 1.67 RUN COAXIAL CABLE FOR SAM HOOKUP
  • 820415 003586 E30A001 RCS DECONTAMINATION 1 CN 0.005 2.67 RUN COAXIAL CABLE FOR SAM HOOKUP 820419 003603 E30A001 RCS DECONTAMINATION 1 CH 0.010 2.50 PULL CABLE /RUN CONDUIT-RCF V-4 & V-9
  • 820419 003603 E30A001 RCS DECONTAMINATION 6 CN 0.053 13.95 PULL CABLE /RUN CONDUIT-RCF V-4 & V-9 i

820427 003687 E30A001 RCS DECONTAMINATION 11 CN 0.063 21.75 INSTL T VLVES/RUN TUBES TO A62-AN.A64-AR 4

  • 820427 003687 E30A001 RCS DECONTAMINATION 3 HP 0.005 4.41 INSTL T VLVES/RUN TUBES TO A62-AN A64-AN l

820427 003688 E30A001 RCS DECONTAMINATION 11 CN 0.060 17.15 INSTALL AIR LINES / HOOK UP SANDPIPdR PUMP

  • 820427 003688 E30A001 RCS DECONTAMINATION 2 OP 0.005 3.08 INSTALL AIR LINES / HOOK UP SANDPIPER PUMP ns
  • 820427 003688 E30A001 RCS DECONTAMINATION 1 HP 0.010 3.00 INSTALL AIR LINES / HOOK UP SANDPIPER PUMP

%J 820428 003706 E30A001 RCS DECONTAMINATION 2 CN 0.020 6.75 INSTALL TEMP N-2 SYSTEM IN TEST TK AREA a

  • 820428 003706 E30A001 RCS DECONTAMINATION 2 CR 0.005 2.67 INSTALL TEMP N-2 SYSTEM IN TEST TK AREA
  • 820428 003706 E30A001 RCS DECONTAMINATION 11 MM 0.115 21.33 INSTALL TEMP N-2 SYSTEM IN TEST TK AREA
  • 820428 003706 E30A001 RCS DECONTAMINATION 1 OP 0.000 0.42 INSTALL TEMP N-2 SYSTEM IN TEST TK AREA 820428 003709 E30A001 RCS DECONTAMINATION 7 CN 0.148 14.75 INSTALL TEE IN SAMPLE LINE SN18
  • 820428 003709 E30A001 RCS DECONTAMINATION 3 HP 0.042 4.73 INSTALL TEE IN SAMPLE LINE SN18 820504 003762 E30A001 RCS DECONTAMINATION 20 CN 0.349 55.71 HYDROTEST RCS PIPE / REPAIR LEAKS
  • 820504 003762 E30A001 RCS DECONTAMINATION 2 CM 0.000 1.50 HYDROTEST RCS PIPE / REPAIR LEAKS
  • 820504 003762 E30A001 RCS DECONTAMINATION 3 ES 0.035 6.92 HYDROTEST RCS PIPE / REPAIR LEAKS
  • 820504 003762 E30A001 RCS DECONTAMINATION 1 HP 0.010 1.33 HYDROTEST RCS PIPE / REPAIR LEAKS
  • 820504 003762 E30A001 RCS DECONTAMINATION 5 OA 0.058 10.00 HYDROTEST RCS PIPE / REPAIR LEAKS
  • 820504 003762 E30A001 RCS DECONTAMINATION 1 CR 0.005 1.67 HYDROTEST RCS PIPE / REPAIR LEAKS 820506 003786 E30A001 RCS DECONTAMINATION 3 CN 0.035 3.67 ADJUST LIMIT SWITCHES-EVAP COND TK RM
  • 820506 003786 E30A001 RCS DECONTAMINATION 1 OA 0.010 0.75 ADJUST LIMIT SWITCHES-EVAP COND TK RM 820512 003831 E30A001 RCS DECONTAMINATION 14 CN 0.300 28.42 INSTALL HANGERS / ANCHOR
  • 820512 003831 E30A001 RCS DECONTAMINATION 1 HP 0.035 2.17 INSTALL HANGERS / ANCHOR
  • 820512 003831 E30A001 RCS DECONTAMINATION 1 OS 0.020 1.08 INSTALL HANGERS / ANCHOR 820512 003832 E30A001 RCS DECONTAMINATION 1 CN 0.075 1.33 REMOVE HYDRO PUMP & HOSES / GEN CLEANUP 820513 003838 E30A001 RCS DECONTAMINATION 1 OP 0.010 1.50 VALVE LINEUP FOR RCS PROCESSING
  • 820513 003838 E30A001 RCS DECONTAMINATION 1 HP 0.010 1.50 VALVE LINEUP FOR RCS PROCESSING 820513 003852 E30A001 RCS DECONTAMINATION 1 CN 0.005 1.83 VERIFY RCS PROCESSING FLOW
  • B20513 003852 E30A001 RCS DECONTAMINATION 2 OP 0.020 3.42 VERIFY RCS PROCESSINMG FLOW
  • 820513 003852 E30A001 RCS DECONTAMINATION 1 ES 0.010 1.67 VERIFY RCS PROCESSING FLOW 840412 008814 E30A001 RCS DECONTAMINATION 3 HP 0.029 1.88 CHANGE SAM II AT

'C' BLEED TANK 841219 010518 E30A001 RCS DECONTAMINATION 1 HP 0.008 4.80 LET DOWN 100 GAL OF RCS THRU BORONOMETER 841219 010518 E30A001 RCS DECONTAMINATION 1 CM 0.005 2.13 LET DOWN 100 GAL OF RCS THRU BORONOMETER RCS DECONTAMINATION 1 EG 0.008 5.47 LET DOWN 100 GAL OF RCS THRU BORONOMETER 84121'.,010518 E30A001 84121 110518 E30A001 RCS DECONTAMINATION 1 OP 0.007 5.63 LET DOWN 100 GAL OF RCS THRU BORONOMETER

.SUBTO Al -

EXP TRCK NUMBER

= E30A001 PERS ENTRG

=

172

~ _ _ _ _ _ _

m___

_1__

DATE 021886 PAGE 3

PNO.

2-

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D L

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • DATE. NUMBER. NUMBER,

ACTIVITY

.ENTRG CODE. REM

. HOURS TASK DESCRIPTION

. EXPOS. REM

= 1.9600000

. RWP HOURS = 353.93000 790405 022221 E30C001 AFHB SYS & TKS DECON 4 CN 0.055 0.00 RECOMBINER COVERAGE

  • 790405 022221 E30C001 AFHB SYS & TKS DECON 1 VI 0.025 0.00 RECOMBINER COVERAGE 790409 022156 E30C001 AFHB SYS & TKS DECON 2 EL 0.016 0.00 MOVE CABLE TO RECOMBINER 790413 021363 E30C001 AFHB SYS & TKS DECON 3 EL 0.180 0.00 CHECK POWER CABLE FOR RECOMBINER 800123 0B0487 E30C001 AFHB SYS & TKS DECON 1 CN 0.020 1,58 INSTALL TENT AROUND RECOMBINER
  • 800123 080487 E30C001 AFHB SYS & TKS DECON 2 CR 0.040 2.00 INSTALL TENT AROUND RECOMBINER 800124 080502 E30C001 AFHB SYS & TKS DECON 1 CR 0.070 2.08 INSTALL TENT AROUND RECOMBINER 800124 080517 E30C001 AFHB SYS & TKS DECON 1 CN 0.005 1.75 DECON H-2 RECOMBINER PAD
  • 800124 080517 E30C001 AFHB SYS & TKS DECON 1 CR 0.005 1.33 DECON H-2 RECOMBINER PAD 800125 080546 E30C001 AFH6 SYS & TKS DECON 1 CN 0.000 1.00 DECON H-2 RECOMBINER PAD
  • 800125 080546 E30C001 AFHB SYS & TKS DECON 1 CR 0.005 1.00 DECON H-2 RECOMBINER PAD 800125 080547 E30C001 AFHB SYS & TKS DECON 1 CR 0.000 1.00 INSTALL TENT AROUND RECOMBINER 800128 080621 E30C001 AFHB SYS & TKS DECON 2 CN 0.180 1.75 DECON SPILL INSIDE RECOMBINER. TENT
  • 800128 0B0621 E30C001 AFHB SYS & TKS DECON 1 CR 0.105 0.08 DECON SPILL INSIDE RECOMBINER TENT

$00324 081801 E30C001 AFHB SYS & TKS DECON 1 CN 0.020 1.10 DECON H-2 RECOMBINER

  • 800324 081801 E30C301 AFHB SYS & TKS DECON 1 CR 0.018 1.05 DECON H-2 RECOMBINER
  • 800324 081801 E30C001 AFHB SYS & TKS DECON 1 UM 0.028 0.76 DECON H-2 RECOMBINER 300325 081829 E30C001 AFHB SYS & TKS DECON 1 CN 0.020 1.33 DECON H-2 RECOMBINER d3 '*800325 081829 E30C001 AFHB SYS & TKS DECON 2 CR 0.048 1.92 DECON H-2 RECOMBINER co 800327 081881 E30C001 AFHB SYS & TKS DECON 3 CN 0.038 1.95 XFER RECOMB BLOWER FROM TENT /DECON TENT
  • 800327 081881 E30C001 AFHB SYS & TKS DECON 1 CR 0.020 0.93 XFER RECOMB BLOWER FROM TENT /DECON TENT
  • 800327 081881 E30C001 AFHB SYS & TKS DECON 1 UM 0.020 0.93 XFER RECOMB BLOWER FROM TENT /DECON TENT 800514 083020 E30C001 AFHB SYS & TKS DECON 1 CN 0.005 0.57 STAGE FOR FLUSH OF RECOMBINER FILL SYS 800516 083083 E30C001 AFHB SYS & TKS DECON 4 CN 0.015 10.00 FLUSH RECOMBINER/ CHANGE FILTERS
  • 800516 0B3083 E30C001 AFHB SYS & TKS DECON 3 CR 0.010 9.00 FLUSH RECOMBINER/ CHANGE FILTERS 800520 083137 E30C001 AFHB SYS & TKS DECON 2 CN 0.040 0.00 DRAIN & REFILL RECOMBINER 800522 0B3206 E30C001 AFHB SYS & TKS DECON 2 CN 0.020 5.67 FLUSH RECOMBINER TO DRAIN 800528 083282 E30C001 AFHB SYS & TKS DECON 1 CN 0.000 3.25 DECON RECOMBINER INTERNALS & FLUSH 800530 083358 E30C001 AFHB SYS & TKS DECON 2 CN 0.005 2.00 FLUSH RECOMBINER/ CHANGE FILTER 800626 083903 E30C001 AFHB SYS & TKS DECON 1 CN 0.005 1.33 DECON RECOMBINER TENT
  • 800626 083903 E30C001 AFHB SYS & TKS DECON 1 CR 0.000 1.33 DECON RECOMBINER TENT 800703 084022 E30C001 AFHB SYS & TKS DECON 1 CN 0.005 5.75 DECON RECOMBINER TENT
  • 800703 084022 E30C001 AFHB SYS & TKS DECON 2 CR 0.010 5.67 DECON RECOMBINER TENT 800726 084321 E30C001 AFHB SYS & TKS DEGON 1 CN 0.000 0.42 CHG FLTRS/DECON HOT SPOTS IN RECOMB TENT
  • 800726 084321 E30C001 AFHB SYS & TKS DECON 1 CR 0.000 0.42 CHG FLTRS/DECON HOT SPOTS IN RECOMB TENT 800728 084326 E30C001 AFHB SYS & TKS DECON 3 CR 0.002 4.68 FLUSH RECOMBINER COILS 3800728 084326 E30C001 AFHB SYS & TKS DECON 1 EL 0.005 3.17 FLUSH RECOMBINER COILS 800728 084350 E30C001.AFHB SYS & TKS DECON 3 CN 0.000 4.33 DECON RECOMBINER TENT / BAG JOINTS 800828 089308 E30C001 AFHB SYS & TKS DECON 3 CN 0.000 16.25 FLUSH RECOMBINER
  • 800828 089308 E30C001 AFHB SYS & TKS DECON 6 CR 0.015 23.17 FLUSH RECOMBINER 800904 089335 E30C001 AFHB SYS & TKS DECON 1 CN 0.000 2.50 FLUSH RECOMBINER
  • 800904 089335 E30C001.AFHB SYS & TKS DECON 1 CR 0.0^0 2.50 FLUSH RECOMBINER 800910 084951 E30C001 AFHB SYS & TKS DECON 4 CN 0.015 11.66 ADO WATER TO RECOMBINER & FLUSH
  • 800910 084951 E30C001 AFHB SYS & TKS DECON 6 CR 0.002 14.17 ADD WATER TO RECOMBINER & FLUSH 801030 085467 E30C001 AFHB SYS & TKS DECON 3 CN 0.000 6.70 STAND RECOMBINER UPRIGHT 801031 085479 E30C001 AFHB SYS & TKS DECON 2 CR 0.000 2.00 DRAIN RECOMBINER

.801106 085519 E30C001 AFHB SYS & TKS DECON 2 CR 0.020 4.00 DECON RECOMBINER & GENERAL AREA 801129 085715 E30C001 AFHB SYS & TKS DECON 1 CN 0.003 1.58 REPLACE FILTER WDG-F-1

m_.

m

]

DATE 021886 PAGE 4

i PNO.

3 1

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS

. DEPT. EXPOS.RWP

  • DATE. NUMBER. NUMBER.

ACTIVITY

.ENTRG. CODE. REM

. HOURS.

TASK DESCRIPTION

  • ssassa,ssessa,assasssa,asessamassassassungs,asesus.. asses,assass,sesses.ussoas,ssassa,essesessassassassssssssssssssssssssssses, f
  • 801129 085715 E30C001 AFHB SYS & TKS DECON 1 OP 0.000 0.67 REPLACE FILTER WDG-F-1 7
  • 801129 085715 E30C001 AFH8 SYS & TKS DECON 1 MM 0.005 1.33 REPLACE FILTER WDG-F-1 1

' *801129 085715 E30C001 AFHB SYS & TKS DECON 2 UM 0.015 2.67 REPLACE FILTER WDG-F-1 820428 003708 E30C001 AFHB SYS & TKS DECON 1 CN 0.015 2.67 GAMMA SPEC ANALYSIS OF MU TANK & PIPING

$820428 003708 E30C001 AFHB SYS & TKS DECON 1 CR 0.020 2.67 GAMMA SPEC ANALYSIS OF MU TANK & PIPING 820519 003898 E30C001 AFH8 SYS & TKS DECON 2 CN 0.075 4.50 GAMMA SCAN OF SEAL RETURN COOLER & MUF-3

  • 820519 003898 E30C001 AFHB SYS & TKS DECON 1 CR 0.040 2.17 GAMMA SCAN OF SEAL RETURN COOLER & MUF-3 820706 004220 E30C001 AFHB SYS & TKS DECON 1 UM 0.000 1,67 DECON FLOOR & WALL
  • 820706 004220 E30C001 AFH8 SYS & TKS DECON 1 HP 0.000-1.33 DECON FLOOR & WALL 820909 004687 E30C001 AFH8 SYS & TKS DECON 1 CN 0.030 2.17 GAMMA SCAN OF BLOCK ORIFICE IN MUV ROOM
  • 820909 004687 E30C001 AFHB SYS & TKS DECON 1 HP 0.015 2.17 GAMMA SCAN OF BLOCK ORIFICE IN MUV ROOM

_*820909 004687 E30C001 AFHB SYS & TKS DECON 1 CR 0.018 2.25 GAMMA SCAN OF BLOCK ORIFICE IN MUV ROOM 820913 004693 E30C001.AFHB SYS S TKS DECON 5 UM 0.020 8.75 INSTALL RAMP IN CORRIDOR TO MUV ROOM 1

  • 820913 004693 E30C001 AFHB SYS & TKS DECON 1 HP 0.000 2.33 INSTALL RAMP IN CORRIDOR TO MUV ROOM 830322 006119 E30C001 AFH8 SYS & TKS DECON 1 OP 0.007 3.00 RBAT-FLUSH WDS-T-3/ VALVE LINEUP FOR FLSH'
  • 830322 006119 E30C001 AFH8 SYS & TKS DECON 1 MM 0.008 2.97 R8AT-FLUSH WDS-T-3/ VALVE LINEUP FOR FLSH
  • 830322 006119 E30C001 AFHB SYS & TKS DECON 1 IC 0.008 2.97 R8AT-FLUSH WDS-T-3/ VALVE LINEUP FOR FL5f t
  • 830322 006119 E30C001 AFHB SYS & TKS DECON 1 CN 0.005 3.98 R8AT-FLUSH WDS-T-3/ VALVE LINEUP FOR FLSH 830329 006168 E30C001 AFHB SYS & TKS DECON 1 OP 0.005 0.00 FLUSH RBAT & ASSOCIATED PIPING

$3 *830329 006168 E30C001 AFH8 SYS & TKS DECON 1 MM 0.003 3.05 FLUSH RBAT & ASSOCIATED PIPING i

us ' 830405 006208 E30C001 AFH8 SYS & TKS DECON 1 OP 0.000 1.02 REMOVE HOSES FROM 000R OPENING a

e. *830305 006208 E30C001 AFHB SYS & TKS DECON 1 HP 0.009 1.22 REMOVE HOSES FROM DOOR OPENING

  • 830465 006208 E30C001 AFH8 SYS & TKS DECON 1 CM 0.000 1.18 REMOVE HOSES FROM DOOR OPENING 830818 007255 E30C001 ~ AFH8 SYS & TKS DECON 1 MM 0.000 1.22 INSTALL TEMP BALL VALVE 10DG1A t

830508 006455 E30C001 AFHB SYS & TKS DECON 1 ES 0.003 0.67 PHOTOGRAPH 3 INCH RESIN FILL LINES t

840404 008766 E30C001 AFH8 SYS & TKS DECON 6 HP 0.420 15.32 FLUSH DECAY HEAT REMOVAL SYSTEM

  • 840404 008766 E30C001 AFH8 SYS & TKS DECON 8 HP 0.572 20.20 FLUSH DECAY HEAT REMOVAL SYSTEM 840410 008802 E30C001 AFHB SYS & TKS DECON 2 HP 0.250 8.57 DRAIN & REFILL PUMP & COOLER
  • 840410 008802 E30C001 AFH8 SYS & TKS DECON 3 OP 0.493 12.97 DRAIN & REFILL PUMP & COOLER 840421 008868 E30C001 AFHB SYS & TKS DECON 2 OP 0.067 2.80 FLUSH

'B' DECAY HEAT LOOP

  • 840421 008868 E30C001 AFHB SYS & TKS DECON 1 CN 0.042 1.50 FLUSH

'B' DECAY HEAT LOOP 841215 010481 E30C001 AFHB SYS & TKS DECON 2 OP 0.140 4.48 FLUSH FLOORS, WALLS AND EQUIP-FH8 281'

  • 841215 010481 E30C001 AFHB SYS & TKS DECON 1 RP 0.078 2.28 FLUSH FLOORS, WALLS AND EQUIP-FHB 281*
  • 841215 010481 E30C001 AFH8 SYS & TKS DECON 1 CN 0.060 3.28 FLUSH FLOORS, WALLS AND EQUIP-FHB 281' 1

. SUBTOTAL -

EXP TRCK NUMBER.= E30C001 PERS ENTRG : s 148

. EXPOS REM 3.5180000

=

. RWP HOURS e 295.69000 4

.790615 026748 E30D056 RCBT B&C DECON 4 CN 0.030 0.00 MOVE RECOMB-FUEL POOL TO INTERMED BLDG 1

810223 000526 E30D056 RCBT B&C DECON 2 OP 0.175 1.00 VALVE LINEUP DN

  • B' BLEED TANK
  • 810223 000526 E30D056 RCBT B&C DECON 1 HP 0.060 0.50 VALVE LINEUP ON

'8*

BLEED TANK 810814 001705 E300056 RCBT B&C DECON 6 MM 0.105 7.42 INSTALL ADAPTERS-WDL V-153A, 1538, 18A

  • 810814 001705 E30D056 RCBT B&C DECON 1 CN 0.010 1.25 INSTALL ADAPTERS-WOL V-153A. 1538, 18A 810818 001732 E30D056 RCBT B&C DECON 10 CN 0.190 19.90 GAMMA SPEC SURVEY OF TANK SLUDGE
  • 810818 001732 E30D056 RCBT B&C DECON 1 CR 0.025 2.75 GAMMA SPEC SURVEY OF TANK SLUDGE

'i

  • 810818 001732 E30D056 RCBT B&C DECON 1 OA 0.000 0.33 GAMMA SPEC SURVEY OF TANK SLUDGE 810818 001734 E30D056 RCBT B&C DECON 1 CN 0.045 1.42 DRAIN SIGHT GLASS TO REDUCE HOT SPOT

$810818 001734 E30D056 RCBT B&C DECON 1 OP 0.045 2.67 DRAIN SIGHT GLASS TO REDUCE HOT SPOT 810821 001766 E300056' RCBT B&C.DECON 2 CN 0.025 2.83 DRAIN LOWER LEVEL SIGHT GLASS

.i

  • 810821 001766 E300056 RCBT B&C DECON 1 OP 0.010 2.00 DRAIN LOWER LEVEL SIGHT GLASS t-

DATE 021886 PAGE 5

PNO.

4

.TMI-2 UNC: DOS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP TASK DESCRIPTION

  • DATE. NUMBER. NUMBER ACTIVITY

.ENTRG CODE. REM

. HOURS

  • ....................................................................................................=......=..............===..

810822 001772 E300056 RCBT B&C DECON 1 CN 0.005.

1.00 RMVE ADPTR FLNGE/ CONN LNS-WDL-V-18A,B.C

  • 810822 001772 E30D056 RCBT B&C DECON 1 OP 0.005 1.08 RMVE ADPTR FLNGE/ CONN LNS-WDL-V-18A.B.C
  • 810822 001772 E30D056 RCBT B&C DECON 2 MM 0.040 2.00 RMVE ADPTR FLNGE/ CONN LNS-WDL-V-18A.B.C 820226 003399 E30D056 RCBT B&C DECON 1 CM 0.005 1.67 SAMPLE RC BLEED TANK

'C' 3820226 003399 E30D056 RCBT B&C DECON 1 CH 0.000 1.83 SAMPLE RC BLEED TANK

'C' 820129 003409 E300056 RCBT B&C DECON 1 CN 0.010 3.33 SAMPLE & ANALYZE RCS & RCBT

'C'

  • 820329 003409 E30D056 RCBT B&C DECON 1 CH 0.005 3.33 SAMPLE & ANALYZF RCS & RCBT

'C' 820331 003453 E300056 RCBT B&C DECON 1 CN 0.005 1.33 SAMPLE RCBT

'C'

  • 820331 003453 E30D056 RCBT B&C DECON 1 CH 0.000 1.17 SAMPLE RCBT

'C

  • 820331 003453 E30D056 RCBT B&C DECON 1 HP 0.005 1.33 SAMPLE RCBT
  • C' 831018 007794 E30D056 RCBT B&C DECON 10 CM 0.006 46.38 RCBT RESIN TESTING 831021 007803 E30D056 RC8T B&C DECON 4 CM 0.000 22.67 RCBT RESIN TESTING

.SU8 TOTAL -

EXP TRCK NUMBER

= E30D056 PERS ENTRG 56

. EXPOS REM

= 0.8060000

. RWP HOURS 129.19000

.810817 001728 E300057 RCBT A DECON 3 CN 0.025 4.17 CONNECT HOSES / PUMP & FLUSH RCBT

  • A'
  • 810817 001728 E30D057 RC8T A DECON 12 OP 0.134 29.75 CONNECT HOSES / PUMP & FLUSH RCBT

'A' 810924 002086 E30D057 RCBT A DECON 1 ME 0.000 0.40 DISCON TEMP SAMP SYS AT WOL-18A,B.C

,ta *810924 002086 E300057 RCBT A DECON 3 MM 0.015 3.73 DISCON TEMP SAMP SYS AT WDL-18A,8,C ca 810930 002093 E30D057 RCBT A DECON 2 CN 0.013 3.67 FLUSH RCBT

'A' s 2810930 002093 E30D057 RCBT A DECON 5 OP 0.042 22.58 FLUSH RCBT

  • A' 810930 002096 E30D057 RCBT A DECON 1 CN 0.035 1.00 REMOVE TK MANWAY COVER / GASKET & REPLACE
  • 810930 002096 E30D057 RCBT A DECON 1 OP 0.020 2.00 REMOVE TK MANWAY COVER / GASKET & REPLACE
  • 810930 002096 E30D057 RCBT A DECON 1 HP 0.030 3.00 REMOVE TK MANWAY COVER / GASKET & REPLACE
  • 810930 002096 E30D057 RC8T A DECON 1 ME 0.060 1.00 REMOVE TK MANWAY COVER / GASKET & REPLACE 2810930 002096 E30D057 RC8T A DECON 3 MM 0.100 6.00 REMOVE TK MANWAY COVER / GASKET & REPLACE 811001 002102 E30D057 RCBT A DECON 2 CN 0.070 2.07 SAMPLE & SURVEY TANK INTERNALS
  • 811001 002102 E30D057 RCBT A DECON 1 CR 0.020 0.87 SAMPLE & SURVEY TANK INTERNALS
  • S11001 002102 E30D057 RCBT A DECON 1 MM 0.040 1.12 SAMPLE & SURVEY TANK INTERNALS 811002 002106 E30D057 RCBT A DECON 3 CN 0.090 7.78 VACUUM & FLUSH RC8T
  • A*
  • 811002 002106 E300057 RCBT A DECON 4 CR 0.095 11.37 VACUUM & FLUSH RC8T

'A'

  • 811002 002106 E30D057 RCBT A DECON 1 ES 0.060 3.35 VACUUM & FLUSH RCBT *A'
  • 811002 002106 E300057 RCBT A DECGN 2 MM 0.070 5.68 VACUUM & FLUSH RCBT

'A'

  • 811002 002106 E30D057 RCBT A DECON 2 UM 0.055 5.68 VACUUM & FLUSH RCBT

'A'

  • 811002 002106 E30D057 RCBT A DECON 1 OP 0.010 2.33 VACUUM & FLUSH RCBT

'A'

  • 811002 002106 E300057 RCBT A DECON 1 HP 0.040 2.33 VACUUM & FLUSH RCBT

'A' 811007 002137 E30D057 RCBT A DECON 6 CN 0.105 12.67 SPARGE & FLUSH RCBT

'A'

  • 811007 002137 E30D057 RC8T A DECON 11 CR 0.261 24.67 SPARGE & FLUSH RCBT

'A'

  • 811007 002137 E30D057 RC8T A DECON 6 MM 0.192 15.83 SPARGE & F LUSH RCBT

'A'

  • 811007 002137 E30D057 RCBT A DECON 6 UM 0.037 15.00 SPARGE & FLUSH RC87

'A'

  • 811007 002137 E30D057 RCBT A DECON 4 OP 0.028 8.08 SPARGE & FLUSH RCBT

'A' 2811007 002137 E30D057 RCBT A DECON 4 HP 0.080 8.58 SPARGE & FLUSH RC8T

'A' 811010 002153 E30D057 RCST A DECON 1 CN 0.020 1.50 REPLACE MANWAY COVER & GASKET

  • 811010 002153 E30D057 RCBT A DECON 1 OP 0.020 2.50 REPLACE MANWAY COVER & GASKET
  • 811010 002153 E30D057 RCBT A DECON 3 MM 0.075 5.25 RE PL ACE MANWAY COVER & GASKE T 811019 002200 E300057 RCBT A DECON 1 CN 0.010 2.50 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE
  • 811013 002200 E30D057 RCBT A DECON 2 CR 0.010 4.75 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE
  • S11019 002200 E30D057 RCBT A DECON 1 HP 0.010 2.50 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE
  • 811019 002200 E300057 RCBT A DECON 2 UM 0.005 4.75 GROSS FLUSH INSIDE OF TK/DECON & DESTAGE

DATE 021886 PAGE 6

PNO.

5

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • DATE 3....... NUMBER. NUMBER............................,..........ENTRG...............................................................................,

ACTIVITY CODE. REM

. HOURS TASK DESCRIPTION 811019 002210 E300057 RCBT A DECON 2 CN 0.005 1.33 SAMPLE RCBT

'A' AT SANDPIPER PUMP

  • 811019 002210 E300057 RCBT A DECON 2 OP 0.000 2.08 SAMPLE RC8T

'A' AT SANDPIPER PUMP 820323 003362 E30D057 RCBT A DECON 2 CN 0.020 5.25 FLUSH & SAMPLE RCBT

'A' 2820323 003362 E300057 RCBT A DECON 1 CH 0.005 2.33 FLUSH & SAMPLE RCBT

'A'

  • 820323 003362 E300057 RCBT A DECON 3 OP J.043 9.33 FLUSH & SAMPLE RC8T

'A'

  • 820323 003362 E300057 RCBT A DECON 1 HP 0.010 2.75 FLUSH & SAMPLE RCBT

'A' 820328 003405 E300057 RCBT A DECON 1 CN 0.030 3.67 RECIRC RCBT 'A'/SAMP & DISCONNECT HOSES

  • 820323 003405 E30D057 RCBT A DECON 1 OP 0.022 4.08 RECIRC RC8T 'A*/SAMP & DISCONNECT HOSES 820331 003434 E300057 RCBT A DECON 1 CN 0.065 3.42 REMOVE DRUMS FROM RCBT 'A'/ PUMP TO CWT
  • 820331 003434 E30D057 RCBT A DECON 4 CR 0.110 10.00 REMOVE DRUMS FROM RCBT 'A'/ PUMP TO CWT
  • 820331 003434 E30D057 RCBT A DECON 1 MM 0.020 1.00 REMOVE DRUMS FROM RCBT 'A*/ PUMP TO CWT
  • 820331 003434 E30D057 RCBT A DECON 2 UM 0.055 5.50 REMOVE DRUMS FROM RCBT

'A'/ PUMP TO CWT

  • 820331 003434 E300057 RCBT A DECON 1 HP 0.025 2.67 REMOVE DRUMS FROM RCBT

'A'/ PUMP TO CWT 821217 005355 E30D057 RCBT A DECON 5 CN 0.045 8.37 REMOVE EQUIP FROM RCBT

  • A*

ROOM

  • 821217 005355 E300057 RCBT A DECON 1 HP 0.010 1.10 REMOVE EQUIP FROM RC8T

'A' ROOM 830502 006411 E30D057 RCBT A DECON 1 CN 0.010 1.07 REMOVE & INSTALL MANWAY/ SCRAPE SAMPLES

  • 830502 006411 E30D057 RCBT A DECON 4 MM 0.080 8.00 REMOVE & INSTALL MANWAY/ SCRAPE SAMPLES 3830502 006411 E30D057 RCBT A DECON 1 HP 0.020 2.43 REMOVE & INSTALL MANWAY/ SCRAPE SAMPLES

. SUBTOTAL -

EXP TRCK NUMBER E30D057

=

. PERS ENTRG.

133 ca

. EXPOS REM 2.4520000 RWP HOURS 302.84000

-s

. 800414 082291 E30D40A MAKEUP FILTERS DECON 1 CN 0.010 1.33 STAGE AREA TO PULL FILTERS 2A.28,5A,5B e

  • 300414 0B2291 E30D40A MAKEUP FILTERS DECON 4 CR 0.040 4.33 STAGE AREA TO PULL FILTERS 2A.28.5A.5B 800415 082301 E30040A MAKEUP FILTERS DECON 3 CN 0.055 3.67 REMOVE MAKEUP FILTERS 2A & SA
  • 800415 082301 E30D40A MAh'UP FILTERS DECON 2 CR 0.025 1.50 REMOVE MAKEUP FILTERS 2A & 5A 800415 082302 E30040A MAKEUP FILTERS DECON 4 CN 0.075 5.13 MOVE FLTR TRANSPORT SHIELD TO SHLD CASK 2800415 082302 E30040A MAKEUP FILTERS DECON 2 CR 0.010 1.67 MOVE FLTR TRANSPORT SHIELD TO SHLD CASK
  • 800415 0B2302 E30040A MAKEUP FILTERS DECON 1 UM 0.000 1.00 MOVE FLTR TRANSPORT SHIELD TO SHLD CASK 800501 082716 E30D40A MAKEUP FILTERS DECON 5 CN 0.040 4.92 ASSESS SOLIDS ON MUF-5A FILTER HOUSING
  • 800501 082716 E30D40A MAKEUP FILTERS DECON 2 CR 0.020 2.00 ASSESS SOLIDS ON MUF-5A FILTER HOUSING 800909 084933 E30D40A MAKEUP FILTERS DECON 3 CN 0.015 1.83 DRY RUN TRAINING FOR FILTER CHANGE 800910 084944 E30D40A MAKEUP FILTERS DECON 9 CN 0.093 10.26 TRAINING FOR MUF CHANGE / STAGE FOR CHANGE 2800910 084944 E30D40A MAKEUP FILTERS DECON 1 EL 0.005 1.33 TRAINING FOR MUF CHANGE / STAGE FOR CHANGE x800910 084944 E30D40A MAKEUP FILTERS DECON 1 HP 0.008 1.08 TRAINING FOR MUF CHANGE / STAGE FOR CHANGE
  • 800910 0B4944 E30040A MAKEUP FILTERS DECON 3 CR 0.030 3.50 TRAINING FOR MUF CHANGE / STAGE FOR CHANGE 800911 084954 E30040A MAKEUP FILTERS DECON 3 CN 0.085 3.17 REMOVE MU FILTERS 2A, 28, SB
  • 800911 084954 E30D40A MAKEUP FILTERS DECON 3 CR 0.080 3.17 REMOVE MU FILTERS 2A, 2B, 58
  • 800911 084954 E30040A MAKEUP FILTERS DECON 1 HP 0.010 1.08 REMOVE MU FILTERS 2A, 28, 58 800912 084971 E30D40A MAKEUP FILTERS DECON 3 CN 0.025 2.58 REMOVE MU FILTERS 2A, 28, 58
  • 800912 084971 E30D40A MAKEUP FILTERS DECON 3 CR 0.030 2.17 REMOVE MU FILTERS 2A, 28, 58
  • 800912 084971 E30040A MAKEUP FILTERS DECON 1 HP 0.020 0.92 REMOVE MU FILTERS 2A. 28, 58 801010 085263 E30D40A MAKEUP FILTERS DECON 5 CN 0.083 7.50 HYDROTEST MDH FLTR/INSTL TUBING VALVES
  • 801010 085263 E30D40A MAKEUP FILTERS DECON 1 CR 0.010 1.17 HYDROTEST MDH FLTR/INSTL TUBING VALVES 801021 085366 E30040A MAKEUP FILTERS DECON 2 CN 0.020 1.67 HYDRO TEST FILTER CASK SECT. OF MOH SYS, 810113 000093 E30D40A MAKEUP FILTERS DECON 2 CN 0.007 2.08 DECON FTS/ MOVE FTS TO MODEL ROOM
  • 810113 000093 E30D40A MAKEUP FILTERS DECON 1 CR 0.010 2.00 DECON FTS/ MOVE FTS TO MODEL ROOM
  • 810113 000093 E30D40A MAKEUP FILTERS DECON 1 EL 0.010 2.00 DECON FTS/ MOVE FTS TO MODEL ROOM 810225 000558 E30D40A MAKEUP FILTERS DECON 2 CN 0.015 3.17 MOCK RUN-REMOVAL OF HU FILTERS 2A,28 58
  • 310225 000558 E30D40A MAKEUP #ILTERS DECON 2 CR 0.008 2.33 MOCK RUN-REMOVAL OF MU FILTERS 2A,28,58 Y

_.. ~

. - - - - - ~. __

L 1

DATE 021886 PAGE 7

y PNO.

6

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

=

.RWP

.EXP TRCK.

.ENTRG. CODE. REM

. HOURS TASK DESCRIPTION PERS DEPT. EXPOS.RWP I

  • DATE. NUMBER. NUMBER.

ACTIVITY

......................==........=.........

2

  • 810225 000558 E30D40A MAKEUP FILTERS DECON 12 MM

. 0.120 17.67 MOCK RUN-REMOVAL OF MU FILTERS 2A.28,5D 810228 000577 E30D40A MAKEUP FILTERS DECON 1 CN 0.025 4.32 REMOVE & PKG MU FILTERS 2A, 2B&SB

  • 810228 000577 E30040A MAKEUP FILTERS DECON 1 CR 0.020 4.02 REMOVE & PKG MU FILTERS 2A, 2B, & 58
  • 810228 000577 E30040A MAKEUP FILTERS DECON 1 HP 0.015 4.27 REMOVE & PKG MU FILTERS 2A, 28, & SB
  • 810228 000577 E30D40A MAKEUP FILTERS DECON 6 MM 0.152 23.29 REMOVE & PKG MU FILTERS 2A. 2B & 5B

.810304 000621 E30D40A MAKEUP FILTERS DECON 2 CN 0.020 4.00

-0BTAIN SAMPLES / GEN CLEANUP /PH0Y0 GRAPHS

  • 810304 000621 E30040A MAKEUP FILTERS DECON 1 CR Q.017 2.00 OBTAIN SAMPLES / GEN CLEANUP / PHOTOGRAPHS i

810309 000646 E30040A MAKEUP FILTERS DECON 2 CN 0.015 3.00 WET VAC AND GENERAL DECON 810320 000726 E30040A MAKEUP FILTERS DECON 1 CN 0.000 0.33 PREJOB SITING & PHOTOGRAPHS OF MU-F-AA/B

  • 810320 000726 E30040A MAKEUP FILTERS DECON 1 CR 0.002 0.33 PREJOB SITING & PHOTOGRAPHS OF MU-F-AA/B 810601 001171 E30D40A MAKEUP FILTERS DECON 2 CN 0.017 3.92 STAGE AREA FOR FILTER REMOVAL i

r

  • 810601 001171 E30040A MAKEUP FILTERS DECON 2 CR 0.010 3.75 STAGE AREA FOR FILTER REMOVAL i
  • 810601 001171 E30040A MAKEUP FILTERS DECON 1 AD 0.010 1.75 STAGE AREA FOR FILTER REMOVAL 1
  • 810601 001171 E30040A MAKEUP FILTERS DECON 2 UM 0.005 3.75 STAGE AREA FOR FILTER REMOVAL 820210 003007 E30D40A MAKEUP FILTERS DECO'N 1 MM 0.010 0.75 WEIGH DRUM CONTAINING MU FILTER 2B
  • 820210 003007 E30040A MAKEUP FILTERS DECON 2 UM 0.005 1.50 WEIGH DRUM CONTAINING MU FILTER 28 l
  • 820210 003007 E30040A MAKEUP FILTERS DECON 1 HP 0.008 0.83 WEIGH DRUM CONTAINING MU FILTER 2B 4

820222 003096 E30040A MAKEUP FILTERS DECON 1 DM 0.005 1.08 CHK FOR HYDROGEN / SECURE LEAD LINER LID i

  • 820222 003096 E30D40A MAKEUP FILTERS DECON 1 AD 0.005 1.00 CHK FOR HYDROGER/ SECURE LEAD LINER LID
  • 820222 003096 E30D40A MAKEUP FILTERS DECON 1 CR 0.010 1.33 CHK FOR HYDROGEN / SECURE LEAD LINER LID
  • 820222 003096 E30D40A MAKEUP FILTERS DECON 1 UM 0.010 1.08 CHK FOR HYDROGEN / SECURE LEAD LINER LID to
  • 820222 003096 E30040A MAKEUP FILTERS DECON 1 HP 0.005 1.00 CHK FOR HYDROGEN / SECURE LEAD LINER LID r0 820317 003313 E30040A MAKEUP FILTERS DECON 3 HP 0.015 4.50 RMVE 28.5A&58 PLUGS / STAGE FOR FLTR PULL
  • 820317 003313 E30040A MAKEUP FILTERS DECON 7 UM 0.020 8.75 RMVE 2B,5A458 PLUGS / STAGE FOR FLTR PUL'
  • 820317 003313 E30D40A MAKEUP FILTERS DECON 1 OP 0.000 1.00 RMVE 28,$A&58 PLUGS / STAGE FOR FLTR PULL
  • 820317 003313 E30D40A MAKEUP FILTERS DECON 2 CR 0.000 2.83 RMVE 28,5A&5B PLUGS / STAGE FOR FLTR PULL
  • 820317 003313 E30040A MAKEUP FILTERS DECON 1 CN 0.000 1.00 RMVE 28.5A&5B PLUGS / STAGE FOR FLTR PULL 820320 003331 E30D40A MAKEUP FILTERS DECON 3 CN 0.023 9.00 OBTAIN SPEC MEASUREMENTS FROM MU FILTERS
  • 820320 003331 E30040A MAKEUP FILTERS DECON 1 CR 0.008 3.17 OBTAIN SPEC MEASUREMENTS FROM MU FILTERS
  • 820320 003331 E30040A MAKEUP FILTERS DECON 1 CH 0.007 1.00 OBTAIN SPEC MEASUREMENTS FROM MU FILTERS 820322 003332 E30D40A MAKEUP FILTERS DECON 1 EG 0.003 0.42 PULL 4A & 48 FILTERS / VACUUM HOUSINGS
  • 830322 003332 E30040A MAKEUP FILTERS DECON 5 HP 0.185 15.50 PULL 4A & 4B FILTERS / VACUUM HOUSINGS
  • 830322 003332 E30040A MAKEUP FILTERS DECON 12 UM 0.372 32.66 PULL 4A & 48 FILTERS / VACUUM HOUSINGS
  • 830322 003332 E30040A MAKEUP FILTERS DECON 2 CR 0.095 6.00 PULL 4A & 4B FILTERS / VACUUM HOUSINGS
  • 830322 003332 E30D40A MAKEUP FILTERS DECON 4 CN 0.090 12.17 PULL 4A & 4B FILTERS / VACUUM HOUSINGS 820322 003352 E30040A MAKEUP FILTERS DECON 2 OP 0.229 2.25 ISOLATE MU FILTER 4A
  • 820322 003352 E30D40A MAKEUP FILTERS DECON 1 HP 0.0G0 1.08 ISOLATE MU FILTER 4A
  • 830322 003352 E30040A MAKEUP FILTERS DECON 2 CN 0.220 1.92 ISOLATE MU FILTER 4A 820324 003364 E30040A MAKEUP FILTERS DECON 5 UM 0.065 8.34 PULL MU FILTERS 2A & 58
  • 820324 003364 E30D40A MAKEUP FILTERS DECON 1 CN 0.010 2.00 PULL MU FILTERS 2A & SB
  • 820324 003364 E30D40A MAKEUP FILTERS DECON 1 CR 0.020 1.58 PULL MU FILTERS 2A & 58
  • 820324 003364 E30040A MAKEUP FILTERS DECON 1 HP 0.010 2.00 PULL MU FILTERS 2A & 58 820324 003384 E30040A MAKEUP FILTERS DECON 8 UM 0.455 17.91 VAC 2A.28,5A.58 MUF HOUSINGS AND FLOOR
  • 820324 003384 E30D40A MAKEUP FILTERS DECON 4 CR 0.155 9.67 VAC 2A,28.5A 58 MUF HOUSINGS AND FLOOR
  • 820324 003384 E30D40A MAKEUP FILTERS DECON 1 CN 0.050 3.00 VAC 2A.2B.5A.58 MUF HOUSINGS AND FLOOR
  • 820324 003384 E30040A MAKEUP FILTERS DECON 2 HP 0.100 5.17 VAC 2A.28.5A.58 MUF HOUSINGS AND FLOOR 831027 007835 E3CD40A MAKEUP FILTERS DECON 5 UM 0.000 4.13 GAMMA SPEC MEASUREMENTS-MUF 28.5A 558
  • 831027 007835 E30040A MAKEUP FILTERS DECON 2 CN 0.002 7.85 GAMMA SPEC MEASUREMENTS-MUF 28.5A &58
  • 831027 007835 E30040A MAKEUP FILTERS DECON 1 HP 0.002 4.22 GAMMA SPEC MEASUREMENTS-MUF 28.5A &58 840412 008812 E30D40A MAKEUP FILTERS DECON 8 UM 0.031 11.63 INSTL SCAF & LD BRICK-CEMENT BLK SHLDG

{

s et

DATE 021886 PAGE 8

PNO.

7

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • DATE... NUMBER. NUMB.ER...............IVIT.Y......,.........ENTRG........ CODE........ HOURS...................................

ION ACT

. REM TASK DESCRIPT 840828 009801 E30D40A MAKEUP FILTERS DECON 5 CN 0.009 8.95 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM

  • 840828 009801 E30040A MAKEUP FILTERS DECON 2 ES 0.005 7.58 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30D40A MAKEUP FILTERS DECON 3 CA 0.000 2.05 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30040A MAKEUP FILTERS DECON 4 EL 0.004 2.97 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30D40A MAKEUP FILTERS DECON 11 MM 0.019 13.72 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30040A MAKEUP FILTERS DECON 2 HP 0.005 9.18 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30040A MAKEUP FILTERS DECON 2 IC 0 005 4.40 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM
  • 840828 009801 E30D40A MAKEUP FILTERS DECON 1 OP 0.000 5.03 PRE-OPER TEST OF MU-P-8 ELUTION SYSTEM

. SUBTOTAL -

EXP TRCK NUMBER

= E30040A PERS ENTRG 231

. EXPOS REM

= 3.5390000

. RWP HOURS 398.16000 820127 002923 E30E33A PWST DECON 6 UM 0.010 20.16 REMOVE PLASTIC & SCAFFOLD TENT AT PWST

  • 820127 002923 E30E33A PWST DECON 2 HP 0.010 10.00 REMOVE PLASTIC & SCAFFOLD TENT AT R4ST 3820127 002923 E30E33A PWST DECON 1 RW 0.008 3.67 REMOVE PLASTIC & SCAFFOLD TENT AT PWST 820707 004224 E30E33A PWST DECON 7 DM 0.005 19.58 REMOVE CONTAMINATED SOIL
  • 820707 004224 E30E33A PWST DECON 3 HP 0.005 11.00 REMOVE CONTAMINATED SOIL 830421 006320 E30E33A PWST DECON 4 IC 0.003 18.27 DECON PROCESSED WATER STORAGE TANK
  • 830421 006320 E30E33A PWST DECON 2 MM 0.005 9.25 DECON PROCESSED WATER STORAGE TANK
  • 830421 006320 E30E33A PWST DECON 1 OP 0.000 6.35 DECON PROCESSED WATER STORAGE TANK ca 831018 007793 E30E33A PWST DECON 1 MM 0.000 1.48 DECON FLANGE IN PWST PUMP HOUSE La
  • 831018 007793 E30E33A PWST DECON 1 OP 0.003 1.50 DECON FLANGE IN PWST PUMP HOUSE 831026 007831 E30E33A PWST DECON 3 IC 0.000 1.57 DECON INSTRUMENT EQUIPMENT 831028 007839 E30E33A PWST DECON 16 IC 0.027 39.70 PREPARE TV CAMERAS / TEST EQUIPMENT
  • 831028 007839 E30E33A PWST DECON 3 HP 0.000 1.22 PREPARE TV CAMERAS / TEST EQUIPMENT 831103 007876 E30E33A PWST DECON 2 IC 0.000 3.60 EQUIPMENT DECON

. SUBTOTAL -

EXP TRCK NUMBER

= E30E33A PERS ENTRG 52

. EXPOS REM 0.0760000

=

RWP HOURS.

147.35000 821202 005221 E30H001 OTSG B DECON 3 CN 0.001 17.08 FLUSH OTSG LINES-M-20 AREA 821202 005222 E30H001 OTSG B DECON 7 CN 0.080 44.77 TIE-IN OTSG NEW PIPE TO OLD PIPE 830105 005486 E30H001 OTSG B DECON 2 OP 0.000 2.33 MOVE CONTAM MATL-SDS AREA TO TURB BLDG 830105 005487 E30H001 OTSG B DECON 2 OP 0.000 0.97 MOVE SANDPIPER TO TURBINE BLDG 830107 005504 E30H001 OTSG B DECON 1 CM 0.000 1.20 PUMP OTSG A MAIN STEAM LINES TO CDT SUMP 2830107 005504 E30H001 OTSG B DECON 3 OP 0.010 14.47 PUMP OTSG A MAIN STEAM LINES TO CDT SUMP

'A' STEAM & FEED LINES TO CDT

  • 830110 005530 E30H001 OTSG B DECON 1 RP 0.000 8.12 PUMP OTSG

'A' STEAM & FEED LINES TO CDT 830112 005548 E30H001 OTSG B DECON 13 OP 0.004 67.03 SET UP & OPERATE OTSG CLEANUP SYSTEM

  • 830112 005548 E30H001 OTSG B DECON 3 MM 0.002 11.45 SET UP & OPERATE OTSG CLEANUP SYSTEM
  • 830112 005548 E30H001 OTSG B DECON 2 HP 0.000 7.65 SET UP & OPERATE OTSG CLE ANUP SYSTEM
  • 830112 005548 E30H001 OTSG B DECON 2 CM 0.000 4.57 SET UP & OPERATE OTSG CLE ANUP SYSTEM 3830112 005548 E30H001 OTSG B DECON 1 RP 0.000 2.00 SET UP & OPERATE OTSG CLEANUP SYSTEM 830119 005619 E30H001 OTSG B DECON 3 OP 0.000 22.85 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830119 005619 E30H001 OTSG B DECON 1 MM 0.000 5.13 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830119 005619 E30H001 OTSG B DECON 1 HP 0.005 6.57 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830119 005619 E30H001 OTSG B DECON 2 CM 0.000 1.22 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 830120 005621 E30H001 OTSG B DECON 2 CN 0.215 1.87 OPERATIONAL CHECK OF OTSG

'B' DRAIN VLVS 830121 005632 E30H001 OTSG B DECON 27 OP 0.005 157.02 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS

DATE 021886 PAGE 9

PNO.

8

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

.RWP

.EXP TRCK.

.PERS DEPT. EXPOS.RWP

  • DATE. NUMBER. NUMBER ACTIVITY

.ENTRG

. HOURS TASK DESCRIPTION s...................................................-... CODE. REM

.OTSG B DECON 12 HP 0.002 26.05 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 2830121 005632 E3CH001

  • S30121 005632 E30H001 OTSG B DECON 7 MM 0.002 32.30 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • S30121 005632 E30H001 OTSG B DECON 2 RP 0.000 10.52 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830121 005632 E30H001 OTSG B DECON 14 CM 0.005 12.95 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830121 005632 E30H001 OTSG B DECON 1 ES 0.000 6.48 SET UP/0PERATE/ TEAR DOEN OTSG B CU SYS 830128 005682 E30H001 OTSG B DECON 2 OP 0.005 9.75 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 3830128 005682 E30H001 OTSG B DECON 1 CM 0.000 0.82 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 830128 005689 E30H001 OTSG B DECON 8 MM 0.000 30.87 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 1830128 005689 E30H001 OTSG B DECON 11 OP 0.000 60.05 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS x830128 005689 E30H001 OTSG B DECON 5 HP 0.003 11.38 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS
  • 830128 005689 E30H001 OTSG B DECON 2 CM 0,000 1.30 SET UP/0PERATE/ TEAR DOWN OTSG B CU SYS 830202 005722 E30H001 OTSG B DECON 3 CN 0.749 5.75 DRAIN OTSG

'B' SECONDARY SIDE 830204 005742 E30H001 OTSG B DECON 2 CN 0.311 2.65 DRAIN OTSG

  • B' SECONDARY SIDE 830209 005786 E30H001 OTSG B DECON 1 OP 0.000 1.00 INSTALL HOSE-ALC-P-1 INF TO ALC-P-4 EFF
  • 830209 0C5786 E30H001 OTSG B DECON 1 HP 0.005 1.00 INSTALL HOSE-ALC-P-1 INF TO ALC-P-4 EFF 830209 005787 E30H001 OTSG B DECON 22 OP 0.005 98.09 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS
  • 830209 005787 E30H001 OTSG B DECON 13 CM 0.000 11.53 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS
  • 830209 005787 E30H001 OTSG B DECON 3 MM 0.002 12.02 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS
  • 830209 005787 E30H001 OTSG B DECON 1 RP 0.000 5.63 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS
  • 830209 005787 E30H001 OTSG B DECON 5 HP 0.000 5.70 DRAIN DOWN OTSG B TO 327 ELEV VIA CU SYS 830214 005814 E30H001 OTSG B DECON 4 CN 0.618 5.53 DRAIN OTSG
  • B*

TO SUMP Id 830216 005850 E30H001 OTSG B DECON 10 OP 0.005 27.11 DRAIN OTSG

'A'

'B' VIA 4X4 CLEANUP SYS

  • 830216 005850 E30H001 OTSG B DECON 3 CM 0.000 2.12 DRAIN OTSG
  • A'

'B' VIA 4X4 CLEANUP SYS

  • 830216 005850 E30H001 OTSG B DECON 1 RP 0.000 3.97 DRAIN OTSG

'A'

  • B' VIA 4X4 CLEANUP SYS
  • 830216 005850 E30H001 OTSG B DECON 3 HP 0.000 2.08 DRAIN OTSG

'A'

& *B' VIA 4X4 CLEANUP SYS 830223 005908 E30H001 OTSG B DECON 5 OP 0.000 10.45 DRAIN OTSG

'A'

'B' VIA 4X4 CLEANUP SYS

  • 830223 005908 E30H001 OTSG B DECON 2 MM 0.000 2.28 DRAIN OTSG

'A'

  • B' VIA 4X4 CLEANUP SYS
  • 830223 005908 E30H001 OTSG B DECON 1 HP 0.000 1.30 DRAIN OTSG

'A'

  • B' VIA 4X4 CLEANUP SYS 830307 006002 E30H001 OTSG B DECON 9 OP 0.000 43.17 MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP
  • 830307 006002 E30H001 OTSG B DECON 1 RP 0.000 6.28 MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP
  • 830307 006002 E30H001 OTSG B DECON 1 CR 0.000 1,42 MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP
  • 830307 006002 E30H001 OTSG B DECON 1 HP 0.000 1.50 MOVE OTSG CU SYS TO XPORTER/DISMNTL EQUIP 830725 007047 E30H001 OTSG B DECON 2 CN 0.000 1.98 RMVE WAX INSIDE GLVBX/DECON CASK & FLOOR 840324 008700 E30H001 OTSG B DECON 2 MM 0.000 10.00 REMOVE MS-V-3A & B FROM SYSTEM 840828 008691 E30H001 OTSG B DECON 1 OP 0.003 1.37 REMOVE INSULATION & DECON PIPING
  • 840323 008691 E30H001 OTSG B DECON 2 CN 0.007 2.25 REMOVE INSULATION & DECON PIPING
  • 840323 008691 E30H001 OTSG B DECON 1 EL 0.000 0.95 REMOVE INSULATION & DECON PIPING
  • 840323 008691 E30H001 OTSG B DECON 1 UM 0.002 1.35 REMOVE INSULATION & DECON PIPING

. SUBTOTAL -

EXP TRCK NUMBER

= E30H001 PERS ENTRG 247

. EXPOS REM

= 2.0460000 RWP HOURS 865.91000

.790409 022143 E30J001 SYS & TKS RX DECON 8 CN 0.000 0.00 TRANSFER RACKS FROM A TO B POOL

  • 790409 022143 E30J001 SYS & TKS RX DECON 1 MM 0.000 0.00 TRANSFER RACKS FROM A TO B POOL 790810 022128 E30J001 SYS & TKS RX DECON 10 CN 0.167 0.00 TRANSFER RACKS FROM A TO B POOL
  • 790410 022128 E30J001 SYS & TKS RX DECON 1 OP 0.030 0.00 TRANSFER RACKS FROM A TO 8 POOL 2790410 022128 E30J001 SYS & TKS RX DECON 3 MM 0.020 0.00 TRANSFER RACKS FROM A TO B POOL 801204 085768 E30J001 SYS & TKS RX DECON 7 CN 0.113 34.00 MOVE RECOMBINER TO RECEIVING DOCK, 801205 085776 E30J001 SYS & TKS RX DECON 4 CN 0.013 24.08 MOVE RECOMBINER TO RECEIVING 00CK' 830713 006947 E30J001 SYS & TKS RX DECON 2 CN 0.000 1.38 MODIFY HANDRAIL & LEG ON PLATFORM'

DATE 021886 PAGE 10 PNO.

9

.TMI-2 UNC: DDS - ACTIVITY REPORT - RCS & SYSTEMS DECONTAMINATION M 286D

_RWP

.EXP TRCK.

,PERS DEPT. EXPOS.RWP

  • DATE _ NUMBER NUMBER ACTIVITY

.ENTRG. CODE. REM

. HOURS.

TASK DESCRIPTION

  • s e s s u s. e sa ssa, s sa m a s sa, ss a mas s ssa ss aa mas sp s,as sses, e ma sse, masses, asses s, a se ssa, as sses, sussm u sa s se s s s ss s s s s ss s s s s s ssssm u s sss ss a,

. SUBTOTAL -

EXP TRCK NUMBER e EJ0J001 PERS ENTRG a

36 EXPOS REM s 0.3430000

. RWP HOURS 59.460000 e

$ GRAND-TOTAL -

PERS ENTRG 1075 e

. EXPOS REM a 14.740000

. RWP HOURS = 2552.5300 END REPORT...

9 Ca.)

U1 9

l l

A t.o,

...t..A -.

,,.c e...

m, ~m t A.

, _... e., c c...,,ses

.,.R,c, O R..

BIBLIOGRAPHIC DATA SHEET NUREG/CR-4315, Vol. 1

/

\\

, L f..-.

3 TeTLE AND SogfiTLg a RpiPit%f & ACCE S$iUN %vwet R Evaluation of Nuclea Facility Decommissioning Projects

/

Sumary Status Report f o * " * * " " ' '"*" " * "

Three Mile Island Unit r *~ ' ~

j'<AP Reactor Coolant System a Systens Decontamination

/

February 1986 o Lu'f-ORis' 7 OATE REPORT i$$UtO MON Y.e v(AR D. H. Doerge, R. L. Miller, S. Scotti May 1986 9 PROJECT T AlabwORE UNef NyWf tR S Fli,0* wing ORG Amt2 AT ON N AME AND W AtLING ADDRE $$ <

%dp /g Co@pf UNC Nuclear Industries Decommissioning Programs Departmen

' o "*

  • v"" "

Fed /300-A/F27, 700 Area P. O. Box 490 Richland, WA 99352 FIN B7568 11 $PONSOAiNG CRG ANi2 ATiON N AME ANO WAILING ADDRESS fewwoe Ia Coore 12s T Y Pt OF R E POR Y Division of Engineering Technology Office of Nuclear Regulatory Research Technical

' ' * " " ' c "'"' " ~ ' ' " * " ' ' "

U. S. Nuclear Regulatory Commission Washington, DC 20555 April 5, 1979 to December 19. 1984 13 $bPPLivf NT ARY %QTES j

w te Lastnact r200 mores or esu This document summarizes information concer ing the deco amination and restoration of the Three Mile Island Unit 2 reactor coola sytem and ot r plant systems which incurred damage during the loss of coolant. accident experi ced on March 28, 1979.

The data collected from activity reports,. reactor containmen entry records, and other sources were placed in a computerized in rmation retrieval /m ipulation system which permits extraction / manipulation of speci ic data which can be

-ilized in planning for recovery activities should a similar ac dent occur in a nuclea generating plant.

The information is presented in both c puter output form and in manually assembled summary.

This report contains only the man-hou spent and radiation exposur actually incurred during performance of tasks in radiat n areas and does not include pport activities outside of radiation areas.

15. Et v WOWD5 aNO OOcuwt47 ANALv515 I SO O t ScR,P T OR $

decontamination radiation exposure data acquisition u A. A.Lt., Liv, sT A rt ot~r i,.

vRgv ctAss,,,ca r,ON vo.tR O,, AGES

, unctassified i, s,t,c,ug cL Ass...c A r o~

ao PR.c.

unlimited unclassified s

i l

_. ~.

UNITED STATES speciat rouars ctAss nare NUCLEAR REGULATORY COMMISSION ms t'$sIO" "'*

WASHINGTON, D.C. 20555

,, ash,o g,,

w 7

OFFICIAL BUSINESS PENALTY FOR PRIVATE USE, $300 I

i 4

4 i

l N

.s.-.

~ - - - _ _4 m.

__