Download: ML20205E116 (2)


See also: IR 05000219/1986012

Text

A

.s.

,-

AUG

8 1986

3

Docket No.

50-219

License No.

DPR-16

GPU. Nuclear Corporation

ATTN: Mr. P. B. Fiedler

Vice President and Director

- Oyster Creek Nuclear Generating Station

P. O. Box 388

Forked River, New Jersey 08731

Gentlemen:

Subject:

Inspection Report No. 50-219/86-12

This refers to the routine safety inspection by Messrs. W. Bateman and

J. Wechselberger from April 14 - June 1,1986 at the Oyster Creek Nuclear

Generating Station and the GPUN Corporat; offices in Parsippany, NJ and the

Region based inspection by Mr. W. Baunack from April 14-17, May 13-16, and

May 27-30, 1986 at the Oyster Creek Nuclear Generating Station. The inspec-

tions consisted of document reviews, interviews and observations of activities

as documented in the enclosed inspection report.

The findings were discussed

with Mr. John Barton and other members of your staff at the conclusion of the

inspection.

Apparent violations of NRC requirements are cited in Appendix A and categorized

under the NRC Enforcement Policy 10 CFR 2 Appendix C (49 FR 8583, March 8,1984).

A reply is required and should be prepared in accordance with Appendix A.

An additional violation, not identified in Appendix A, regarding two inoperable

safety related snubbers identified 'a significant concern in that the plant

operated for at least one complete operating cycle in violation of Technical

Specification limiting conditions for operations. This violation reflects in-

adequate restoration of a plant system upon completion of outage activities.

We will be in contact with you in the near future to schedule an enforcement

conference to discuss this matter. Subsequent enforcement action will be trans-

mitted under separate correspondence.

Overall, these violations highlight continuing problems in control of outage

work and in the implementation of the design change / modification program at

Oyster Creek and are apparently attributable to lack of attention to detail.

-

In many cases this represents a failure to implement procedures associated with

your design change / modification activities. Additional examples of these types

of problems were conveyed to you in previous inspection reports (50-219/86-06

dated May 12, 1986, and 50-219/85-35 dated February 14,1986). This inspection

report also identifies other design review related problems that require your

,

attention. Please be prepared to discuss your overall perspective of the

underlying causes and your plans to resolve these problems at the upcoming

'

enforcement conference.

1

0FFICIAL RECORD COPY

IR OYC 86-12A - 0001.0.0

pmm mik 3

  • '"*'""i

G

. , *

s

GPU Nuclear Corporation

2

-

The responses directed by this letter and the accompanying Notice are not

subject to the clearance procedures of the Office of Management and Budget as

required by the Paperwork Reduction Act of 1980, PL 96-511.

Your cooperation with us in these matters is appreciated.

Sincerely,

Original Signed Bys

William F. Kane, Director

Division of Reactor Projects

Enclosure: NRC Region I Report No. 50-219/86-12

cc w/ encl:

BWR Licensing Manager

Licensing Manager, Oyster Creek

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New Jersey

bcc w/ encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encis)

DRP Section Chief <

DRS Director

DRSS Director

/

g:

2

, o) RI:DRP

[/vBlough

RP

RI:DRS

RI:DRP

DRSS

A

e 'm

Kister

Durr

Bateman/ms

jW

]

7/N/86

7//[/86

7 Jf/86

7//2/86

7hJ /86

0ff h

R:

rf ecki

/]/86

0FFICIAL RECORD COPY

IR OYC 86-12A - 0001.1.0

07/15/86

1

<