ML20204H118

From kanterella
Jump to navigation Jump to search
Forwards Addl Info Re Mechanical Nozzle Seal Assemblies at Facility,As Committed in Util 990310 & 12 Ltrs.List of Encls Provided
ML20204H118
Person / Time
Site: Waterford, San Onofre  
Issue date: 03/23/1999
From: Ewing E
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20204H122 List:
References
W3F1-99-0060, W3F1-99-60, NUDOCS 9903290015
Download: ML20204H118 (6)


Text

7 N

y EntI gy Oper:tions, Inc.

Killona. LA 70066 Tel 504 739 6242 Early C. Ewing, lll J

a ety & Regulatory Affa:rs W3F1-99-0060 A4.05 PR March 23,1999 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20565

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 AdditionalInformation Regarding Mechanical Nozzle Seal Assemblies at Waterford 3 Gentlemen:

By Letter W3F1-99-0043 dated March 10,1999, Entergy submitted a request for Use i

of Mechanical Nozzle Seal Assemblies at Waterford 3. In that request Entergy committed that the results of the analysis would be provided to the NRC Staff for their review upon completion. This commitment was reiterated in Letter W3F1 '

0048, dated March 12,1999. This was expected to occur by March 31,1999. The analysis has been received, reviewed and approved by the En'.ergy Engineering staff. Attachment A provides the analysis for NRC Staff review.

Should you have any questions concerning this information, please contact me at (504) 739-6242 or Curt Taylor at (504) 739-6725.

i Very truly yours, E. C. Ewing

Director, Nuclear Safety and Regulatory Affairs a

ECE/ CWT /ssf Attachment 9903290015 990323 PDR ADOCK 05000302 P

PDR

h i

AdditionalInformation Regarding Mechanical Nozzle Seal Assemblies at Waterford 3 W3F1-99-0060 Page 2 March 23,1999 (w/o Attachment) cc:

E.W. Merschoff, NRC Region IV J. Smith N.S. Reynolds IJRC Resident inspectors Office Administrator Radiation Protection Division (State of Louisians)

American Nuclear insurers (w/ Attachment) cc:

C.P. Patel, NRC-NRR l

l

AdditionalInformation Regarding Mechanical Nozzle Seal Assemblies at Waterford 3 W3F1-99-0060 Page 3 March 23,1999 (w/o Attachment) ccMail:

J.R. McGaha (M-ECH-65)

C.M. Dugger (W-GSB-300)

T.R. Leonard (W-MSB4-300)

R.F. Burski (W-GSB-305)

A.J. Wrape (W-GSB-315)

G.O. Pierce (W-GSB-375)

J.G. Hoffpauir (W-MSB4-336)

E.P. Perkins (W-GSB-318)

C.E. DeDeaux '

(W-GSB-318)

M. K. Brandon (W-GSB-318)

R.E. Allen (W-GSB-102)

J.M. O'Hern (W-EEC-650)

S.J. Bethay (M-ECH-66)

W.K.Hughey (GGNS-ADM/LIC)

J.D. Vandergrift (ANO-GSB/1C)

- R.J. King (R-SB-15)

A.E. Wemett (W-GSB-318)

(w/ Attachment) bcci Waterford 3 Records Center (W-GSB-100)

Licensing Green Folder File i

I

l l

W3F1-99-0060 r

ATTACHMENT A Analysis l

i I

WATERFORD 3 MNSA - DOCUMENT LIST ER-W3-99-0198-00-01 03/23/99 @ l8:05 1.

Design Report No. C-PENG-DR-006 Rev.1, Addendum to CENC-1444 (EC-M94 012) includes as attachments:

A. ASME Code Year Reconciliation i

B. ABB CENP Calculation C-PENG-CALC-018 Rev. 00, " Analysis of Waterford Unit 3 Hot Leg Sampling MNSA."

C. ABB CENP Calculation C-PENG-CALC-019 Rev. 00, " Analysis of Waterford Unit 3 Hot Leg PDT MNSA."

D. ABB CENP Caiculation C-PENG-CALC-020 Rev. 00, " Analysis of Waterford Unit 3 Hot Leg RTD MNSA."

E.ABB CENP Document No. A-WATERFD-9449-1213 Rev. 00,

" Evaluation of attachment Locations for MNSA of Waterford Unit 3 Partial Penetration Welded Nozzles in Hot Leg Piping."

2.

MNSA SQRT File SQ-MN-347 includes as attachments:

A. ABB CENP Engineering Report No. C-NOME-ER-0120, Rev 1 " Design Evaluation of MNSA for Various Applications at Waterford 3"

8. ABB CENP Calculation C-NOME-CALC-0107, Rev 0, " Seismic Qualification of Hot Leg RTD, Hot Leg PDT and Hot Leg Sampling MNSA Hardware,"

C. ABB CENP Calculation S-PENG-CALC-008, Rev 00, " Nozzle Loads for which Bottom Mounted PZR MNSA was Qualified" D. ABB CENP Calculation C-PENG-CALC-021 Rev. 00, " Determination f Waterford 3 Hot Leg Seismic Response Spectra & Accelerations for Use in the Analyses of MNSAs."

E ABB CENP Test Report TR-PENG-033 Rev. 00," Seismic Qualification of the San Onofre, Units 2 and 3 MNSA Clamps for Pressurizer instrument Nozzles and RTD Hot Leg Nozzles" F. ABB CENP Calculation S2-NOME-CALC-0085 Rev 00," Seismic Qualification of Steam Generator PDT, Hot Leg PDT and Hot Leg Sampling MNSA Hardware" l

G. ABB CENP Test Report TR-PENG-042 Rev. 00, "MNSA Hydrostatic l

and Thermal Cycle Test" l

CEdoclistl. DOC 1of2

WATERFORD 3 MNSA - DOCUMENT LIST ER-W3 99-0198-00-01 03/23/99 @ l8:05 3.

ABB CENP Document No. C-NOME-SP-0067, Rev 2, " Design Specification for MNSA at Waterford Unit 3" 5817-12148 Attached to ER-W3-99-0198-00-01 4.

ABB CENP Letter No. NOME-99-C-0123 March 18,1999 " Volume and Surface Area Calculation" Attached to ER-W3-99-0198-00-01 5.

ABB CENP Letter No. NOME-99-C-0124 March 18,1999, March 22, 1999 Rev. 2 " Corrosion issues Associated with the Installation of MNSAs on Leaking Hot Leg Nozzles at Waterford" Attached to ER-W3-99-0198-00-01 6.

ABB CENP Drawing E-MNSAWFD-228-001 Rev. 03," Hot Leg RTD MNSA Flat" 5817-12142 Part of ER-W3-99-0198-00-01 7.

ABB CENP Drawing E-MNSAWFD-228-002 Rev. 03, " Hot Leg PDT MNSA" 5817-12143 Part of ER-W3-99-0198-00-01 8.

ABB CENP Drawing E-MNSAWFD-228-003 Rev. 03, " Hot Leg Sampling MNSA" 5817-12141 Part of ER-W3-99-0198-00-01 9.

ABB CENP Document No. C-NOME-EP-0189, Rev 1, " Engineering Procedure for the Installation of the MNSA for Waterford 3" Attached to WA# 01177163 & 0177164 10.

AEB CENP Document No. STD-100-237, Rev. 00, " Procedure for the Modifit.ition of RCS Pressure Boundary for the Installation of MNSAs for Waterfc d Unit 3"" Attached to WA# 01177163 & 0177164 l

l CEdcclisti. DOC 2 of 2