DFERAilNS DATA'FEFORT '

4 DOCKET

'50-369 l

l

{

DATE 3-13-87 4

OfERATING STATUS ~

COMFLETED BY J. A. Reavis TELEPHONE 704/373-7567

>1. Unit Niee McSUIRE 1

2. Feportirg Feriod: FEBRUARY 1,1987-FEBRUARY 28,1987 l

.3. Licensed Thereal Fower (MWt):

3411

\\

4. Fameplate Rating (6 oss MWe):

1305*

I Notes *Naseplate Rating I

5. Design Electrical Rating (Net MWe):

1190 1 (6ress MWe) calculated as I

6. Maxisua Dependable Capacity (6ross MWe):

1 1450.000 MVA r.90 power l

7. 1arleus Dependable Capa:ity (Net MWe):

!!50 I factor per Fage iii, 1

8. If Changes Occur in Capacity Ratings (itees Number 3 Through 7) Since last i NURE6-0020.

I Report. Give Reasons:

I i

9. Forer Level To W' inch Restricted, if Anf JNet MWe):

" 10. Fenon For Festrictions, If aqy _,,,,,__,_

=...

w This Month Yr.-to-Date Cueulative w

11. Ho'ars in Eeporting Feriod 672.0 1,416.0 45,984.0
12. Nutber Of Hours Feactor Was Critical 639.7 1,383.7-31,411.6
13. Fractor Feserve Shutden, Heurs

--0--

--0--

--0--

o.

14. Hours Genentor On-Line 4

5R7.9 IJ31.9 30,959.4

15. L' nit Reserva Shatdctn Pours

~

--0--

--0--

--0--

16.~ Bross Thereal Erergy Ed.erated (MWH) 1,861,001-4,395,777 87,349,987-

17. Gross Electrical Energy Generated (MWH) 652,051 1,545,579 30,280,756*
18. nit Electrical Energy Severatej (MWH) 625,356 1,4E8,056 28,804,839
19. Unit Se vice Factor 87.5 94.1 67.3*
20. Unit Avellability Factor 87.5 94.I' 67.3-

'!!. Unit Casacity Facter (Usirg EC Net)

8) 9 91.4 '

53.4

~ 22. Unit Capacity Factar tusing DER Net) 78.9 09.1 53.1

23. Unit Forcej Dutage Fate 12.5 5.9 14.3 -

' 24. Shetdedas Schedulei Over Next 6 Months (Type, Date, and Duration of Each):

....FP.9e............................................

m..

-Q)lfShttowrAtEndOfReportFeriod.EstisatedDateofStartur:,,,__,,...,___..,____....,_.....__

26.: Units in Test Status (Frior to Coenercial Operation):

Ferecast A:hieved INii!AL CRITICAllTY INiilAL ELECTRICITY r

COP.NEECIAL OfERAT10N 8703250207 970228 eDR ADOCK 05000369 di a

ena

r-AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-369 UNIT McGuire 1 DATE March 13, 1987 COMPLETED BY

3. A. Reavis TELEPHONE 704-373-7567 MONTH FEBRUARY,1937 DAY AVERASE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWE-Net!

(MWE-Net) 1157 17 765 2

1157 18 893 3

1157 19 0

4 1158 20 503 5

1158 21

!!61 6

1159 22 1161 7

1162 23 1161 8

1153 24 1161 9

1163 25 1163 10 1163 26 1162 11 1163 27 1160 12 761 28

!!60 13 0

14 0

15 502 16 693

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. _QQ-362___________

UNIT-NAME _t?CGUIRE_1________

DATE 03/13/87 PAGE 1 of 2 REPORT MONTH ____ February _1282_

COMPLETED BY [hN 5 h~iiEAViS

~~~~

TELEPHONE _17041-373-7567___

l NET-l R

HOD l

E OF T

A SHU-LICENSE N

Y S

TING EVENT SYS-l CAUSE AND CORRECTIVE O

P DURATION O

DOWN REPORT TEM COMPONENT ACTION TO DATE E

HOURS N

R/X NO.

CODE CODE PREVENT RECURRENCE 4-P 87 8 S

F 22 222222 DISPATCHER REQUIREMENTS l

1 87-2-12 F

50.10 A

4 CB PUMPXX REACTOR COOLANT P'JMP UPPER OIL LOW LEVEL INSPECTION (REACTOR REMAINED CRITICAL) 5-p 87-2-15 F

A HH VALVEX WORK ON HIGH PRESSURE STOP VALVES i

6-p 87-2-17 F

F HG XXXXXX SECONDARY CHEMISTRY OUT OF SPEC l

7-P 87-2-18 S

B IE INSTRU NUCLEAR INSTRUMENTATION CALIBRATION 2

87-2-18 F

34.03 A

3 ED INSTRU INSTANTANEOUS OVERCURRENT RELAY ACTUATION j

8-p 87-2-20 F

F HG XXXXXX HOLD FOR SECONDARY CHEMIGTRY t

9-P 87-2-20 F

A HB VALVEX MOISTURE SEPARATOR REHEATER VALVE MALFUNCTION 1

2 3

4 F Forced Reason:

Method:

Exhibit G - Instructions l

S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data 8-Maintenance or test 2-Manual Scram Entry Sheets For License C-Refueling 3-Automatic Scram Event Report (LER)

}

D-Regulatory Restriction 4-Other (Explain)

File (NUREG-0161) l E-Operator Training & License Examination j

F-Administrative 5

G-Operator Error (Explain)

Exhibit I - Same Source H-Other (Explain) l i

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. _59-369__________.

UNIT NAME _MQGU1RE_1________

DATE 03/13/87 PAGE 2 of 2 REPORT MONTH ____Fetztuary_1982_

COMPLETED BY [hhhh(h hhhh5h[~((

TELEPHONE _1794)-373-7567___

MET-R HOD E

OF T

A SHU-LICENSE N

Y S

TING EVENT SYS-CAUSE AND CORRECTIVE O

P DURATION O

DOWN REPORT TEM COMPONENT ACTION TO DATE E

HOURS N

R/X NO.

CODE CODE PREVENT RECURRENCE 10-p 87-2-20 S

B IE INSTRU NUCLEAR INSTRUMENTATION CALIBRATION 11-P 87-2-20 S

B IE INSTRU NUCLEAR INSTRUMENTATION CALIBRATION 1

2 3

4 F Forced Reason:

Method:

Exhibit G - Instructions S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or test 2-Manual Scram Entry Sheets For License C-Refueling 3-Automatic Scram Event Report (LER)

D-Regulatory Restriction 4-Other-(Explain)

File (NUREG-Ol61)

E-Operator Training & License Examination F-Administrative 5

G-Operator Error (Explain)

Exhibit I - Same Source H-Other (Explain)

DOCKET NO:

50-369 UNIT:

McGuire 1 DATE: 03 /13/87 NARRATIVE

SUMMARY

Month: February, 1987 McGuire Unit 1 began the month at 100% power, but on 2/10 was forced off line by a leak on a Reactor Coolant pump. Maintenance work on the High Pressure Stop Valves of the "A" and "B" Feedpumps was also begun. The unit returned to service on 2/15, but could only increase power to 58% while work was being performed on the "A" Feedpump's Stop Valve. The unit returned to 100% on 2/17, but was forced to reduce power because of Secondary side chemistry limits. On 2/18 the unit tripped after an overcurrent protection circuit on one of the Reactor Coolant pumps failed and caused a ground fault. The circuit was replaced and the unit returned to service on 2/20. The unit operated at 100% for the remainder of the month.

MONTHLY REFUELING INFORMATION REQUEST 1.

Facility name: McGuire, Unit 1 2.

Scheduled next refueling shutdown: October, 1987 3.

Scheduled restart following refueling: December, 1987 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment? Yes If yes, what will these be?

Technical Specification Revision If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions? N/A 5.

Scheduled date(s) for submitting proposed licensing action and supporting information:

N/A 6.

Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).

7.

Number of fuel assemblies (a) in the core:

193 (b) in the spent fuel pool:

221 8.

Present licensed fuel pool capacity:

1463 Size of requested or planned increase:

9.

Projected date of last refueling which can be accommodated by present licensed capacity:

August, 2010 DUKE POWER COMPANY DATE: March 13, 1987 Name of

Contact:

J. A. Reavis Phone: 704-373-7567

a

,s OfERATING DATA REFORT DOCKET 50-370 DATE 3-13-87 0FERATING STATUS

- COMFLETED BY J. A. Reavis TELEPHONE 704/373-7567

1. Unit Nare: Mc6UIRE 2
2. Reporting Feriod: FEERUARY 1,1987-FEBRUARY 28,1987
3. Licensed-Thereal Power (MWt):

3411

-4. Naneplate Rating (Gross MWe):

.1305*

I Notes *Naseplate Rating I

5. Design Electrical Rating (Net MWels 1180 1 (Gross MWe) calculated as 1
6..'taximus Dependable Capacity (Gross MWe): -

l 1450.000 MVA x.90 power l

7. Marisua Dependable Capacity (Net MWe):-

1150 i factor per Page lii, I

' S. If Changes Occur in Capacity Ratings (itens Nueber 3 Through 7) Since Last i NUREG-0020.

I Report. Eive Reasons:

l I

=-=.

...........=--

9. Power Level To Which Restricted, If Any (Net MWe):
10. Reason for Restrictions, if any:. _

This Month Yr.-to-Date Cueulative

11. Fours in Reporting Period 672.0 1,416.0' 26,280.0
12. Nusber Of Hours Reactor Was Critical 672.0 1,346.1 10,745.l*
13. Rcactor Reserve Shutdown Hours

--0--

--0--

--0--

14. Hours Generator On-Line 672.0 1,323.0

.18,193.2'

'15. Unit Reserve Shutdown Heurs

--0-- - -

16. Srcss Thermal Energy Generated (MWH) 2,094,930 4,037,135 59,737,536
17. Grcss Electrical Energy Generated (MWH) 740,941 1,424,233 20,614,228
10. Net Electrical Energy Generated (MWH) 713,917 1,368,270 19,731,695

- 19. Unit Service Factor 100.0 '

93.4 69.2' E0. Unit Aiallability Fact:r 100.0 93.4 69.2

21. Unit Capacity Factor (Usirg MDC Neti 92.4 84.0 64.3
22. Unit Capacity Facter (Using DER Net) 90.0 81.9 63.6
23. Unit Forced Outage Rate 0.0 6.6 18.1

. 24.-Sh;tdcnns Scheduled Over Next 6 Months (Type, Date, and turation of Each):

...F.if.u 6,teg.. May.,b 19_87 -__9 weeks

=.

25. If Shut town At End Of Report Feriod. Estimated Date of Startup:. _.....
26. Units in Test Status (Frior to Cosiercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMERCIAL OFERATION

AVERASE DAILY UNIT POWER LEVEL DOCKET NO.

50-370 UNIT McGuire 2 DATE March 13, 1987 COMPLETED 2Y L A. Reavis TELEPHONE 704-373-7567 MONTH FEBRUARY,1987 DAY AVERASE DAILY POWER LEVEL DAY AVERABE DAILY POWER LEVEL (MWE-Net)

(MWE-Net) 1 657 17

!!61 2

648 18 1163 3

649 19 1161 4

721 20

!!62 5

784 21

!!60 6

763 22 1160 7

!!56 23 1162 8

1154 24 1162 9-1153 25 1163 10

!!57 26 1161 1162 27 1161 12 1163 28

!!61 13 1161 14 1161 15 1161 16

!!61

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. _59-@29__________'_

UNIT NAME _MCGUIRE_2________

DATE _9@f1@f@2_______ _

REPORT MONTH ____ February _12@2_

COMPLETED BY _ggg@LQ_BE9VIS___'_

TELEPHONE _17941-@23-7567___

l NET-l R

HOD l.

E OF l

T A

SHU-LICENSE N

Y S

TING EVENT SYS-CAUSE AND CORRECTIVE O

P DURATION O

DOWN REPORT TEM COMPONENT ACTION TO DATE E

HOURS N

R/X NO.

CODE CODE PREVENT RECURRENCE 7-p 87 1 F

A HH PUMPXX HDLDING AT 58% DUE TO REPAIR ON FEED-WATER PUMP TURBINE

2A" l

A HH PUMPXX HIGH FEEDWATER PUMP OUTBOARD BEARING l 8-p 87 4 F

TEMPERATURE 9-p 87 5 F

A HH PUMPXX HIGH FEEDWATER PUMP OUTBOARD BEARING TEMPERATURE 10-p 87 5 F

A HH PUMPXX REPLACED FEEDWATER PUMP OUTBOARD BEARING 1

2 3

4 F Forced Reason:

Method:

Exhibit G - Instructions S Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or test 2-Manual Scram Entry Sheets For License C-Refueling 3-Automatic Scram Event Report (LER)

D-Regulatory Restriction 4-Other (Explain)

File (NUREG-Ol61)

E-Operator Training & License Examination F-Administrative 5

G-Operator Error (Explain)

Exhibit I - Same Source H-Other (Explain)

g

.'.~

DOCKET NO:

50-370 UNIT:

McGuire 2 DATE: 03/13/87 NARRATIVE

SUMMARY

Month: February, 1987 McGuire Unit 2 began the month at 58% while repairs to the "A" Feedpump were in The repairs were completed on 2/04 and a power increase began. The progress.

increase was halted on 2/05 after bearing temperatures began to rise on the Power was reduced to 57% on 2/05 and the bearings replaced. The unit pump.

then increased power to 100% and remained at that level for the rest of the month.

i l.*

i

-)

MONTHLY REFUELING INFORMATION REQUEST i

.1.

Facility name: McGuire, Unit 2 2.

Scheduled next refueling shutdown: May, 1987 3.

Scheduled restart following refueling: July, 1987 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment? Yes If yes, what will these be?

Technical Specification Revision If no, has reload design and core configuration been reviewed by Safety Review Committee regarding unreviewed safety questions? N/A 5.

Scheduled date(s) for submitting proposed licensing action and supporting information: N/A 6.

Important licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).

7.

Number of fuel assemblies (a) in the core:

193 (b) in the spent fuel pool:

204 8.

Present licensed fuel pool capacity:

1463

-Size of requested or planned increase:

9.

Projected date of last refueling which can be accommodated by present licensed capacity: August, 2010 DUKE POWER COMPANY DATE: March 13, 1987 Name of

Contact:

J. A. Reavis Phone:

704-373-7567

1:-

4 McGUIRE NUCLEAR STATION MONTHLY OPERATING STATUS REPORT l '. Personnel Exposure For the month of January, no individuals exceeded 10 percent of their allowable annual radiation dose limit.

2.

The total station liquid release for January has been compared with the Technical Specifications maximum annual dose conmitment and was less than 10 percent of this limit.

The total station gaseous release for January has been compared with the Technical Specifications maximum annual dose commitment and was less than 10 percent of this-limit.

Duxe POWER GOMPAhT l

P.O. Box 33180 CHARLOTTE, N.C. 28242 HALB. TUCKER reLernown (704) 073-4srn vics,==:===r

,mu.,

1 March 13, 1987 i

I U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C.

20555 Re: McGuire Nuclear Station Docket No. 50-369 and 50-370

Dear Sir:

Please find attached information concerning the performance and operating status of

(

the McGuire Nuclear Station for the month of February,1987.

L Very truly yours, Ed b f q Hal B. Tucker JAR /03/sbn Attachment xc:

Dr. J. Nelson Grace, Regional Administrator American Nuclear Insurers U. S. NucAear Regulatory Commission c/o Dottie Sherman, ANI Library Region II The Exchange, Suite 245 101 Marietta Street, NW, Suite 2900 270 Farmington Avenue Atlanta, Georgia 30323 Farmington, CT 06032 Mr. Phil Ross INPO Records Center U. S. Nuclear Regulatory Commission Suite 1500 MNBB-5715 1100 Circle 75 Parkway Washington, D. C.

20555 Atlanta, Georgia 30323 Mr. Darl Hood, Project Manager Mr. Richard G. Oehl, NE-44 Office of Nuclear Reactor Regulation U. S. Department of Energy U. S. Nuclear Regulatory Commission 19901 Germantown Road Washington, D. C.

20555 Germantown, Maryland 20874 Ms. Judy Dovers Mr. W. T. Orders Nuclear Assurance Corporation NRC Resident Inspector 5720 Peachtree Parkway McGuire Nuclear Station Norcross, Georgia 30092

' \\