1 APR gg y Docket No. 50-293 Mr. William D. Harrington Senior Vice President, Nuclear Boston Edison Company 800 Boylston Street Boston, Massachusetts 02199

Dear Mr. Harrington:

SUBJECT:

GENERIC LETTER 83-28, ITEMS 3.1.3 AND 3.2.3 (TAC 53079, 53868)

Re:

Pilgrim Nuclear Power Station In Generic Letter 83-28, Items 3.1.3 and 3.2.3, the staff requested that you review the existing Technical Specifications for Pilgrim Station to determine whether any post-maintenance testino requirements might degrade rather than enhance safety.

Your responses dated November 7, 1983 and June 28, 1985, stated that no post-maintenance testing requirements had been identified in the Pilgrim Technical Specifications that would degrade safety of the reactor trip system or other safety-related components. The staff, with the assistance of a contractor, has reviewed your responses and has found them to be acceptable.

This concludes the staff's action on Items 3.1.3 and 3.2.3 relative to Pilgrim Station.

I

{ OaktW J hn A. Zwolinski, Director BWR Pro.iect Directorate #1 Division of BWR Licensing cc: See next oaoe DISTRIRtlTION 1 Docket F11e3 -GHolahan NRC PDR DLasher local PDR BWDA1 Reading OELD RBernero EJordan BGrimes JPartlow CJamerson PLeech JZwolinski ACRS (10)

DBL:PD#1 DBL:PD#1

PD#1 CJamerson

/ Pleech:tm JZwolinski f/9jl/86

% /2,V86 8604250088 860422 f/g/86 l

PDR ADOCK 05000293 P

PDR

oq'o,[

g

  • Mo UNITED STATES

~*,

NUCLEAR REGULATORY COMMISSION o

O j

W ASHINGTON, D. C. 20555 April 22,1986 Docket No. 50-293 Mr. William D. Harrinaton Senior Vice President, Nuclear Roston Edison Company 800 Boylston Street Boston, Massachusetts 02199

Dear Mr. Harrington:

SURJECT: GENERIC LETTER 83-28, ITEMS 3.1.3 AND 3.2.3 (TAC 53029, 538681 Re:

Pilorim Nuclear Power Station

~

In Generic Letter 83-28. Items 3.1.3 and 3.?.3, the staff requested that you review the existina Technical Specifications for Pilorim Station to determine whether any post-maintenance testing reouirements might degrade rather than enhance safety.

Your responses dated November 7, 1983 and June ?8, 1985, stated that no post-maintenance testino requirements had been identified in the Pilorirn Technical Specifications that would dearade safety of the reactor trip g

system or other safety-related components. The staff, with the assistance of a contractor, has reviewed your responses and has found them to be acceptable.

This concludes the staff's action on Items 3.1.3 and 3.2.3 relative to Pilgrim Station.

Sincerely,

?$'-M A

a er i

John A. Zwolinski, Director RWR Pro.iect Directorate #1 Division of BWR Licensino cc: See next page

=

Pr. William D. Harrington Boston Edison Company Pilgrim Nuclear Power Station cc:

Mr. Charles J. Mathis, Station Mgr.

Boston Edison Company RFD #1, Rocky Hill Road Plymouth, Massachusetts 02360 Resident Inspector's Office U. S. Nuclear Regulatory Commission Post Office Box 867 Plymouth, Massachusetts 0?360 Chairman, Board of Selectmen 11 Lincoln Street Plymouth, Massachusetts 02360 Office of the Commissioner Massachusetts Department of Environmental Quality Engineering One Winter Street Boston, Massachusetts 02108 Office of the Attorney General 1 Ashburton Place 19th Floor Boston, Massachusetts 02108 g.

Mr. Robert M. Hallisey, Director Radiation Control Program Massachusetts Department of Public Health 150 Tremont Street Boston, Massachusetts 02111 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. James D. Keyes Boston Edison Company 25 Braintree Hill Office Park Braintree, Massachusetts 0?l84