ML20199C141

From kanterella
Jump to navigation Jump to search
Amend 108 to License NPF-57,changes TS 3/4.11.1, Liquid Effluent-Concentration. Change Adds Requirement to Perform Weekly Sampling & Monthly & Quarterly Composite Analyses of Station Service Water Sys
ML20199C141
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 11/06/1997
From: Stolz J
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20199C129 List:
References
NUDOCS 9711190235
Download: ML20199C141 (4)


Text

__ _ _ _ _ _ _ _

p n:o _

y*' 4 UNITED STATES o

}2 NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2066H001 g,

f PH LIC SERVICE ELECTRIC & GAS COMPANY ATLANTIC CITY ELECTRIC COMPANY l DOCKET NO. 50-354 HOPE CREEK GENERATING STATION AMENDMENT TG FACILITY OPERATING LICENSE Amendment No.108 License No. NPF-57

1. The Nuclear Regulatory Comission (the Commission) has found that:

A. The application for amendment filed by the Public Service Electric

& Gas Company (PSE&G) dated September 29, 1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B. The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C. There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in'10 CFR Chapter I; D. The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E. The issuance of this amendment is in accordance with 10 CFR~ Part 51 of the Comniission's regulations and all applicable requirements have been satisfied.

2. Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-57 is hereby amended to read as follows:

9711190235 971106 PDR ADOCK 05000354 P PDR

(2) Technical Specifications and Environmental Protection Plan The Technical Specificaticas contained in Appendix A, as revised through Amendment No.108, and the Environmental Protection Plan contained in Appendix B, are hertby incorporated into the license.

PSE&G shall operate the facility in accordance with the Technical Specifications and the Environwntal Protection Plan.

3. The license amendment is effective as of its date of issuance and shall be implemented within 60 days.

FOR THE NUCLEAR REGULATORY COMMISSION Ji . Stolz, Direglor r ject Directoratq71-2 vision of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of It.suance: November 6, 1997 a

(

ATTACHMENT TO LICENSE AMENDMENT NO.108 FACILITY OPERATING LICENSE NO. NPf-57 DOCKET NO. 50-354 Replace the following page of the Appendix "A" Technical Spectiications with the attached page. The revised page is identified by /ur.endment number and contains vertical lines indicating the area of change.

Remove Jaftri 3/4 11-2 3/4 11-2 f

I l

r TABLE 4.11.1.1.1-1 RADI0 ACTIVE LIOUID WASTE SAMPLING AND ANALYSIS PROGRAM Lower Limit Minimum Type of 4 of Detection Liquid Release Sampling Analysis Activity (LLD)*

Type Frequency Frequency Analysis (pCi/ml)

A. Batch Wasta P P Principal Releaseb Each Batch Each Batch Gamma 5x10

Sample Emitters' Tanks (3)

I-132. lx10

P M Dissolved and 1x10-5 One Batch /M Entrained Gases 7 (Gamma Emitters)

P M H-3 1x10

  • Each Batch Composite d Gross Alpha 1x10 -'

P Q Sr-89, Sr-90 5x10

Each Batch Composite d Fe-55 1x10

B. Continuous M Principal Gamma 5x10

Releases

  • Composite d Emitters
  • Station Service NA Water System I-131 1x10

(GSW) (If contaminated W M Dissolved and 1x10-5 as indicated Grab Sample Entrained Gases by SACS or (Gamma Emitters)

RACS system.

NA M H-3 1x10-5 Composite d Gross Alpha 1x10

NA Q Sr-89, Sr-90 5x10

Composite d Fe-55 1x10

HOPE CREEK 3/4 11-2 Amendment No. 108