TABLE 3.3-10 ACCIDENT MONITORING INSTRUMENTATION-as-g-

REQUIRED MINIMUM-

.g g

NO. OF CHANNELS INSTRUMENT-CHANNELS OPERA 8tE g

1.

Containment Pressure 2

1 h-2.

Reactor Coolant Outlet Temperature

TH0T (Wide Range) 2 1

^

3. _ Reactor Coolant Inlet Temperature - TCOLD (Wide. Range) 2 1

4.

Reactor Coolant Pressure - Wide Range 2

1 y

5.

Pressurizer Water Level 2

1.

6.

Steam Line Pressure 2/ steam generator.

1/ steam generator 7.

Steam Generator Water Level - Narrow Range 1/ steam generator '1/ steam generator-8.

Steam Generator Water Level - Wide Range 1/ steam generator 1/ steam generator 9.

Refueling. Water Storage Tank Water Level 2

1 g

10.

Auxiliary Feedater Flow Rate 2/ steam generator 1/ steam generator-

[

11.

PORY Position Indicator * (0 pen / Closed) 1/ Valve 1/ Valve h

12.

PORY Block Valve Position Indicator ** (0 pen / Closed) 1/ Valve 1/ Valve 13.

Safety Valve Position Indicator (Open/ Closed) 1/ Valve-1/ Valve

--I'_

C--t e 8 --- -rt r1---

n-et-p - u3.. t.o.i (u...- no

)

7 15.

Cortainment Water Level (Wide Range) 2 1

1G.

In Core Thermocouples 4/ core quadrant 2/ core quadrant 17.

Containment High Range Area Radiation N.A.

1 18.

Auxiliary Building Vent Stack - Wide Range Noble Gas N.A.

1/ stack

19. Main Steam Line Radiation N.A.

1/sta line 2>

20.

Reactor Vessel Water Level 2

1 21.

Reactor Coolant Subcooling Ma'rgin Monitor 2***

1***

P3 "b

  • Not applicable if the associated block valve is in the closed position.
    • Not applicable if the block valve is verified in the closed position and power is removed.

g -)

      • Use monitoring channels (10 highest average core exit temperatures) in conjunction with RCS Pressure (item 4 above) to determine the subcooling margin.

e45 1

9901060055 981229 PDR ADOCK05000454,k P