Proposed Tech Specs,Modifying LCO for 3.3.3.7.1 for Chlorine Detection Sys by Changing Alarm/Trip Setpoint from 3 Ppm to 2 Ppm
ML20198G240
Person / Time
Site: Waterford 
Issue date: 12/23/1998
From:
ENTERGY OPERATIONS, INC.
To:
Shared Package
ML20198G238 List:
References
NUDOCS 9812290030
Download: ML20198G240 (9)


Text

,

l l

l 1

l 1

i l

l l

l l

l NPF-38-213 ATTACHMENT A I

1 EXISTING SPECIFICATIONS 1

l A

9812290030 981223 I PDR ADOCK 05000302 P

PDRE l'

s 4

l

{

INSTRUMENTATION.

J CHEMICAL DETECTION SYSTEMS 1

j CHLORINE DETECTION SYSTEM LIMITING CONDITION FOR OPERATION 3.3.3.7.1 Two independent chlorine detection systems, with their alarm / trip setpoints adjusted to actuate at a chlorine concentration of less than or equal to 3 ppm, shall be OPERABLE.

i l

APPLICABILITY:

All MODES.

ACTION:

1 a.

With one chlorine detection system inoperable, restore the i

inoperable detection system to OPERA 8LE status within 7 days or l

within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> initiate and maintain operation of the control room ventilation system in the isolate mode of l

operation.

b.

With no chlorine detection system OPERABLE, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> initiate and maintain operation of the control room ventilation system in the isolate mode of operation.

l c.

The provisions of Specification 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.3.3.7.1 Each chlorine detection system shall be demonstrated OPERABLE by performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and a CHANNEL CALIBRATION at least once per 31 days.

WATERFORD - UNIT 3 3/4 3-47 AMENDMENT N0. 21,53

'LE'3.3-4 ENGINEERED SAFETY FEATURES ACTUATION SYSTEN INSTRUNENTATION TRIP VALUES ALLOMABLE FUNCTIONAL UNIT TRIP SE1 POINT VALUES-1.

SAFETY INJECTION (SIAS) i a.

Manual (Trip Buttons)

Not Applicable Not Appltcable b.

Containment Pressure - High s 17.1 psia

_$ 17.4 psia l

c.

Pressurizer Pressure - Low 2 1684 psla"'

2 1649.7 psla"'

l l

d.

Automatic Actuation Logic Not Applicable Not Applicable

[

[

2.

CONTAllelENT SPRAY (CSAS) a.

Manual (Trip Buttons)

Not Applicable Not Applicable L

b.

Containment Pressure -- High-High s 17.7 psia 5 218.0 psia i

c.

Automatic Actuation Logic Not Applicable-Not Applicable 3.

CONTAllWIENT ISOLATION (CIAS) a.

Manual CIAS (Trip Buttons)

Not Applicable Not Applicable b.

Containment Pressure - High s 17.1 psia s 17.4 psia l

c.

Pressurizer Pressure - Low 2 1684 psla"'

2 1649.7 psla"'

l d.

Automatic Ac'aation Logic Not Applicable Not Applicable

{

l 4.

MAIN STEAN LINE ISOLATION a.

Manual (Trip Buttons)

Not Applicable Not Applicable j

b.

Steam Generator Pressure - Low 2 764 psta

2 749.9 psla

l c.

Containment Pressure - High s 17.1 psia

$ 17.4 psia l

l d.

Automatic Actuation Logic Not Applicable Not Applicable l

l WATERFORD - UNIT 3 3/4 3-19 AMElWMENT NO.136

e n

- - _na1 a

4 e 4 i

1 l

i i

1 NPF-38-213 ATTACHMENT B PROPOSED MARKED-UP SPECIFICATIONS

'LE 3.3-4 j

ENGINEERED SAFETY FEATURES ACTUATION SYSTEN INSTRUMENTATION TRIP VALUES ALLOMABLE

.f FUNCTIOML UNIT TRIP SETPOINT VALUES

-l F

1.

SAFETY INJECTION (SIAS) a.

Manual (Trip Buttons) rat Applicable Not Appilcable

]

b.

Containment Pressure - High s 17.1 psia s 17.4 psia l

[

c.

Pressurizer Pressure - Low 2 1684 psla"'

2 1649.7 psla"8 l

l d.

Automatic Actuation Logic Not Applicable Not Applicable i

2.

CONTAIMENT SPRAY (CSAS) a.

Manual (Trip Buttons)

Not Applicable Not Applicable l

L i

b.

Containment Pressure -- High-High s 17.7 psia s fit:t psia

/&O j

c.

Automatic Actuation Logic Not Applicable Not Applicable l

t 3.

CONTAIMENT ISOLATION (CIAS) a.

Manual CIAS (Trip Buttons)

Not Applicable Not Applicable b.

Containment Pressure - High 5 17.1 psia s 17.4 psia l

c.

Pressurizer Pressure - Low 2 1684 psla"3 2 1649.7 psla"'

l f

d.

Automatic Actuation Logic Not Applicable Not Applicable

(

l 4.

MAIN STEAM LINE ISOLATION i

a.

Manual (Trip Buttons)

Not Applicable Not Applicable l

b.

Steam Generator Pressure - Low 2 764 psia"3 2 749.9 ps,/28 l

c.

Containment Pressure - High s 17.1 psia s 17.4 psia l

l d.

Automatic Actuation Logic Not Applicable Not Applicable j

i i

i WATERFORD - UNIT 3 3/4 3-19 AMENOMENT No.136 f l

t;

s a

I INSTRUMENTATION.

1 CHEMICAL DETECTION SYSTEMS l

CHLORINE DETECTION SYSTEM LIMITING CONDITION FOR OPERATION 3.3.3.7.1 Two independent chlorine detection systems, with their alarm / trip setpoints adjusted to actuate at a chlorine concentration of less than or equal to )fppm, 11 be OPERABLE.

A APPLICABILITY:

MODES.

ACTION:

a.

With one chlorine detection system inoperable, restore the inoperable detection system to OPERABLE status within 7 days or within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> initiate and maintain operation of the control room ventilation system in the isolate mode of l

operation.

b.

With no chlorine detection system OPERABLE, <ithin 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> initiate and maintain operation of the control room ventilation system in the isolate mode of operation.

l c.

The provisions of Specification 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.3.3.7.1 Each chlorine detection system shall be demonstrated OPERABLE by performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and a CHANNEL CALIBRATION at least once per 31 days.

WATERFORD - UNIT 3 3/4 3-47 AMENDMENT NO. 2I,53

NPF-38-213 ATTACHMENT C PROPOSED SPECIFICATIONS i

i

-..=

l i

INSTRUMENTATION CHEMICAL DETECTION SYSTEMS CHLORINF DETECTION SYSTEM l

LIMITING CONDITION FOR OPERATION 3.3.3.7.1 Two independent chlorine detection systems, with their alarm / trip l

setpoints adjusted to actuate at a chlorine concentration of less than or i

equal to 2 ppm, shall be OPERABLE.

l APPLICABILITY: All MODES.

l ACTION:

a.

With one chlorine detection system inoperable, restore the inoperable detection system to OPERABLE status within 7 days or within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> initiate and maintain operation of the control room ventilation system in the isolate mode of operation.

b.

With no chlorine detection system OPERABLE, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> initiate and maintain operation of the control room ventilation system in the isolate mode of operation.

c.

The provisions of Specification 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.3.3.7.1 Each chlorine detection system shall be demonstrated OPERABLE by performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and a CHANNEL

. CAllBRATION at least once per 31 days.

l i

J WATF.RFORD - UNIT 3 3/4 3-47 AMENDMENT NO. Gh53 l

l l

I i

.-._ _ -__. ~

TABLE 3.3-4 ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION TRIP VALUES ALLOWABLE FUNCTIONAL UNIT TRIP SETPOINT VALUES 1.

SAFETY INJECTION (SlAS) a.

Manual (Trip Buttons)

Not Applicable Not Applicable t

b.

Containment Pressure - High s 17.1 psia

. s 17.4 psia T

c Pressurizer Pressure - Low 21684 psia")

21649.7 psia")

d.

Automatic Actuation Logic Not Applicable Not Applicable 2.

CONTAINMENT SPRAY (CSAS) a.

Manual (Trip Buttons)

Not Applicable Not Applicable b.

Containment Pressure - High-High s 17.7 psia s 18.0 psia l ;

c.

Automatic Actuation Logic Not Applicable Not Applicable j

3.

CONTAINMENT ISOLATION (CIAS) a.

Manual C!AS (Trip Buttons)

Not Applicable Not Applicable b.

Containment Pressure - High s 17.1 psia s 17.4 psia t

c.

Pressurizer Pressure - Low 21684 psia")

21649.7 psia")

j i

d.

Automatic Actuation Logic Not Applicable Not Applicable 4.

MAIN STEAM LINE ISOLATION l

a.

Manual (Trip Buttons)

Not Applicable Not Applicable i

b.

Steam Generator Pressure - Low 2 764 psia (2>

2 749.9 psia c23 c.

Containment Pressure - High s 17.1 psia s 17.4 psia d.

Automatic Actuation Logic Not Applicable Not Applicable WATERFORD - UNIT 3 3/4 3-19 AMENDMENT NO.136

[