NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20666-0001 4....,o December 11, 1998 Dr. Robert L. Seale, Chairman Advisory Committee on Reactor Safeguards U.S. Nuclear Regulatory Commission Washington DC 20555-001
SUBJECT:
PROPOSED RULE ON USE OF ALTERNATIVE SOURCE TERM AT OPERATING REACTORS
Dear Dr. Seale:
Thank you for your letter of November 19,1998, on the subject of the proposed rule on use of alternative source term at operating reactors. We appreciate the Advisory Committee on Reactor Safeguards (ACRS) review of the proposed rule package. Your letter notes that the ACRS supports the proposed rule. The staff expects to send the proposed rule package to the Commission by December 15,1998.
In your letter you recommended that each application for use of the revised source term should be evaluated with r.espect to absolute values of core damage frequency, large early release frequency, and the effects of the proposed plant modifications on these risk measures. The staff requirements memorandum (SRM) for SECY-98-158, dated September 4,1998, directed the staff to initiate the exploration of options that consider the use of risk information as a means of providing a risk perspective relative to increased applications of the alternative source term. The SRM directed that this work should not delay the current rulemaking activities but should proceed in parallel to provide a basis for risk informing the current source term rulemaking or future source term rulemaking changes, when and if appropriate. As noted in the proposed Federa/ Register notice, the staff will be preparing a draft regulatory guide (DG-1081) to support the proposed rule. The staff expects to address probabilistic risk assessment (PRA) issues related to plant modifications based on an alternative source term in this draft guide.
Consistent with Regulatory Guide 1.174, An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Current Licensing Basis, the draft guide willindicate that PRA insights may need to be considered if the proposed changes to the plant configuration are not addressed in currently approved staff positions. The staff expects to have the draft guide available for ACRS review in June 1999.
Sincerelg
}Y30 fY
, \\
Executive Director for Operations cc:
Chairman Jackson Commissioner Dieus Commissioner Diaz Commissioner McGaffigan Commissioner Merrifield SECY 9812160286 981211 PDR ACRS GENERAL PDR
Dr. Robert L. S als, Chairman Advisory Committra on Reactor Safeguards December 11, 1998 U.S. Nucl:ar Regulatory Commission Washington DC 20555-001 3
SUBJECT:
PROPOSED RULE ON USE OF ALTERNATIVE SOURCE TERM AT OPERATING REACTORS
Dear Dr. Seale:
Thank you for your letter of November 19,1998, on the subject of the proposed rule on use of alternative source term at operating reactors. We appreciate the Advisory Committee on Reactor Safeguards (ACRS) review of the proposed rule package. Your letter notes that the ACRS supports the proposed rule. The staff expects to send the proposed rule package to the Commission by December 15,1998.
In your letter you recommended that each application for use of the revised source term should be evaluated with respect to absolute values of core damage frequency, large early release frequency, and the effects of the proposed plant modifications on these risk measures. The staff requirements memorandum (SRM) for SECY-98-158, dated September 4,1998, directed the staff to initiate the exploration of options that consider the use of risk information as a means of providing a risk perspective relative to increased applications of the alternative source term. The SRM directed that this work should not delay the current rulemaking activities but should proceed in parallel to provide a basis for risk informing the current source term rulemaking or future source term rulemaking changes, when and if appropriate. As noted in the proposed Federal Register notice, the staff will be preparing a draft regulatory guide (DG-1081) to support the proposed rule. The staff expects to address probabilistic risk assessment (PRA) issues related to plant modifications based on an alternative source term in this draft guide.
Consistent with Regulatory Guide 1.174, An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on P/ ant-Specific Changes to the Current Licensing Basis, the draft guide will indicate that PRA insights may need to be considered if the proposed changes to the plant configuration are not addressed in currently approved staff positions. The staff expects to have the draft guide available for ACRS review in June 1999.
Originalsigned by Sincerely, Vimam D.Travora William D. Travers Executive Director for Operations cc:
Chairman Jackson Commissioner Dicus Commissioner Diaz Commissioner McGaffigan Commissioner Merrifield SECY DISTRIBUTIOB PUBLIC JBlaha OGC JBlaha EDO# 19980693 SCollins/FMiraglia OPA FBurns PKnapp BBoger OCA HThompson PERB Reading File MClark (19980693)
AThadani JRoe NRR Mail Room (19980693)
PNorry DMatthews NOlsen DOCUMENT NAME: G:\\sfl\\g980693.wpd ACRS
- prior concurrence To receive a copy of this document. indicate in the box: "C" = Copy w/o attachment. "E" = Copy w/ attachment. "N" = No copy OFC
- PERB C
- SC:PERB
- SC:PERB Tech.Ed.
AD:DRPM NAME SlaVie REmch CMiller
- RSanders
- JRoe DATE 11/27/98 12/02/98 12/02/98 12/ /98 12/02/98 OFC
- D:NRR
_JEDO
[
NAME SCollins YhraverMf I
DATE 12/04 /98 12/I,(/98 OFFICIAL RECORD CDPY
9 l*
l Distribution; Central File PERB R/F l
BZaleman l
PUBLIC 1
/
l DOCUMENT NAME: G:\\sfl\\g980693.wpd
- prior concurrence 1
/
To receive a copy of this document, indicate in the box: "C" = Copy w/o attachment "E" = Copy w/ attachment, "N" = No copy OFC PERB C
SC:PERB C
SC:P$RB F
Tech.Ed.
AD:DRPM 6
REmch [f[
CMiller/ &
- RSanders JRoe
/
l' NAME SlaVie q
p DATE 11/27/98 12/ 1/98
/
12/ 7J98 12/ /98 12/ ?]98 fu
/
OFC D:NRR EDO f
4 NAME. SCollins WTravers/
DATE; 12/l//98 12/ /98 r --
i q,C/'
j/
OFFICIAL RECORD COPY pp
/
/
/
i
/
?
I s
i
Disitibution:
Central File PERB R/F BZalcman PUBLIC DOCUMENT NAME: G:\\sfl\\g980693.wpd To receive a copy of this document, indicate in the box: "C" = Copy w/o attachment. "E" = Copy w/ attachment, "N" = No copy OFC PERB C
SC:PERB SC:PERB Tech k (A)D:DRP h
NAME SlaVie REmch CMiller RSanders JRoe DATE 11/27/98 L 12/ /98 12/ /98 12// /98 12/ /98
- =.-. summmmmmmmassemnames.:=:- ::---
samms=== = =
sameh esse muse OFC D:NRR EDO NAME SCollins WTravers DATE 12/ /98 12/ /98 OFFICIAL RECORD COPY
i ACTION
~8
-/n EDO' Principal Correspondence Control LFROM:
.DUE:-12/21/98 EDO CONTROL: G19980693 k,(1 DOC DT: 11/19/98 FINAL REPLY:
'R.L'L.-Seale, ACRS L. TO t.
Chairman Jackson 4
FOR SIGNATURE OF :.
- GRN CRC-NO: 98-1068 Travers,.EDO DESCt' ROUTING:
. PROPOSED RULE ON USE OF ALTERNATIVE SOURCE TERM AT Travers
. OPERATING REACTORS Knapp
= Thompson Norry Blaha Burns
'DATE: 11/23/98' Thadani, RES Mtichell, OEDO
' ASSIGNED TO:-
CONTACT:
ACRS File
,NRR Collins SPECIAIEINSTRUCTIONS OR REMARKS:
.Pr0 pare response to ACRS for EDO signature.
Adc.
Ccmmissioners and SECY as cc's.
_.USE SUBJECT LINE-IN' RESPONSE.
~
qgg[pcxcon.%RPR'.k ACT\\0R
\\,
pg CEcEtso: Weer%W8 00E T014RR DIRECTOR'S OFFIC fgg; Rootim. 0 ohd /A'$cja BY
// #
g,,
~ ~ ~ ~ ~ ~ ~
MEoOM l M R.yL - (Ac
2 OFFICE OF THE SECRETARY I
CORRESPONDENCE CONTROL TICKET PAPER NUMBER::
. CRC-98-1068.
LOGGING DATE: Nov 20 98 ACTION OFFICE:
EDO AUTHOR:
.R.L.SEALE AFFILIATION:
ADVISORY COMMITTEE ON' REACTOR SAFEGUARDS
' ADDRESSEE:
CHAIRMAN JACKSON LETTER DATE:
Nov 19 98 FILE CODE: OM-7 ACRS
SUBJECT:
PRO RULE ON USE OF ALTERNATIVE SOURCE TEAM AT OPERATION REACTORS ACTION:
. Appropriate DISTRIBUTION:
CHAIRMAN, RF SPECIAL HANDLING: NONE
. CONSTITUENT:
s;
.g NOTES:
DATE DUE:
. SIGNATURE:
DATE SIGNED:
AFFILIATION:
s.
ti
(,
EDO -- G980693
. _ - - _ _ _ _ _ _ _ _. ~ _.~.____..._., __.__. _ _ _ _.. _. _ _ _ _. _ _ _ _ - _
nog'o UNITED STATES NUCLEAR REGULATORY COMMISSION
{;
f g_
g ia ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, D. C. 20666 j
November 19,1998 The Honorable Shirley Ann Jackson Chairman U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001
Dear Chairman Jackson:
SUBJECT:
PROPOSED RULE ON USE OF ALTERNATIVE SOURCE TERM AT OPERATING REACTORS During the 457th meeting of the Advisory Committee on Reactor Safeguards, November 4-7,1998, we reviewed the proposed rule on use of the attemative source term at operating reactors and discussed the status of the associated pilot application under way at the Perry Nuclear Power Plant. During this meeting, we had the benefit of discussions with representatives of the NRC staff. We also had the benefit of the documents referenced.
The regulations (10 CFR Parts 50 and 100) and associated regulatory guides include a conservative source term (TID-14844) that the staff has considered acceptable for performing design-basis accident (DBA) analyses and for assessing the suitability of the containment design for an intended site. This source term is characterized by the composition and magnitude of the radioactive material, timing of release from the reactor core, and physical / chemical form of radionuclides assumed to enter into the containment under accident conditions. In practice, this source term has also been utilized in other regulatory activities, including assessment of the requirements for equipment qualification and for control room habitability.
New knowledge and experience gained through severe accident research revealed that the TID-14844 source term was unrealistic compared to what would be expected if a reactor actually experienced a core-damage accident of a magnitude commensurate with the DBAs.
Consequently, the staff developed a revised source term (in NUREG-1465) with the intention that it be applied to the design and siting of future light-water reactors. The major changes in the revised source term were: an extended timing of introduction of the fission products; a change in the predominant chemical form of fission-product iodine from gaseous D
U U
a s
D Olf/l^"sF# 4p jj g
S..
es-g w w -
r w
yw
-r-rwg-
+-+e.-
w
2 to particulate; an increase in the quantities of iodine, cesium, and tellurium; and an increase in the number of fission-product groups.
The proposed rule would allow licensees to voluntarily apply the revised source term to operating plants. The staff has conducted a number of activities to obtain information for use in deciding whether this proposed rule is appropriate and acceptable, including the following:
Identified likely plant modifications that would result from applications of the revised source term.
Sponsored studies at the Grand Gulf, Surry, and Zion nuclear power plants using both the TID-14844 and the revised source term to gain insights on the impacts related to DBA doses.
Undertook review of pilot plant studies submitted to address a range of revised source term applications to operating plants.
Performed limited evaluations for the Grand Gulf and Surry plants to determine the risk implications [ core damage frequency (CDF), large, early release frequency (LERF), and latent fatalities) of selected plant modifications.
The outcomes of the above activities include:
The DBA doses are generally smaller with the revised source term (in some cases by a factor of six), implying the potential for relaxation of the fission product control requirements.
The effects on the above risk metrics are insignificant.
+
Considerable margin exists with respect to the magnitude of the revised source term, compared to the releases expected to accompany a DBA.
As a result of these findings for a very limited sample of plants, the staff has concluded that there is sufficient justification for the proposed rule that would allow plants to voluntarily adopt the revised source term and make appropriate plant modifications. Such modifications would have to be implemented by a license amendment under 10 CFR 50.90 (a new Section 50.67 would be added to provide the implementation requirements). The licensee would be i
required to repeat applicable portions of the DBA analyses included in its Final Safety Analysis Report to demonstrate compliance with regulatory requirements in the revised total effective dose equivalent (TEDE) form.
Because of the regulatory significance of source-term usage, we have had a long-standing interest in the subject. Previously, our endorsements of the staff's source-term related efforts have included: updating and defining a more realistic source term; using TEDE and the " worst
- two hours for dose acceptance criteria; developing guidance on acceptable methods for determining source-term mitigation in containment by natural and engineered 1
safety feature processes; allowing application of the revised source term to operating plants (including partial application - particularly the timing of the release of fission products); and developing a better understanding of the risk implications for implementing the revised source term in operating plants, i
The primary reason for our past support to the development of a more realistic DBA source term was due to a concem that use of an unrealistic source term can result in placing regulatory and design emphasis in the wrong areas. There is also the possibility that risk-significant effects may have been missed or that safety enhancements may have been precluded. An unrealistic source term can result in unnecessarily burdensome regulatory requirements.
in formulating the proposed rule, the staff has developed risk information in two areas:
The risk implications relative to CDF and LERF.
The margins related to the DBA source term magnitude associated with best-estimate DBA releases.
The staff's efforts in addressing these two areas of concem have been commendable. The staff has done what could be expected within the constraints of the existing regulatory framework.
For the subject rulemaking, it is clear that, to some degree, the likely plant modifications will adversely affect the potential for some quantity of fission product release for plants opting to use the revised source term. For most plants, it is unlikely that the increases in fission product release will be of unacceptable amounts. To a large extent, this is confirmed by the risk-informed values calculated for CDF and LERF. This should be verified, however, for each application.
Recommendations In view of the low risk and the possible benefits, we support the proposed rule that
+
would allow licensees to apply the revised source term to operating plants on a voluntary basis.
Each application for use of the revised source term should be evaluated with respect to absolute values of CDF, LERF, and the effects of the proposed plant modifications on these risk metrics.
Sincerely, R. L. Seale Chairman
o
,?
.' References 1
Memorandum, dated October 16, 1998, from Jack W. Roe, Office of Nuclear Reactor Regulation, NRC, to John T. Larkins, ACRS,
Subject:
Transmittal of the Draft Proposed Rule Package - Proposed Amendments to 10 CFR Parts 21,50, and 54; Regarding Use of an Altemative Source Term at Operating Reactors.
2 SECY-96154, Memorandum dated June 30,1998, from L. Joseph Callan, Executive Director for Opostions, NRC, for the Commissioners,
Subject:
Results of the Revised (NUREG-1485) Source Term Rebaselining for Operating Reactors.
3.
SECY-98-158, Memorandum dated June 30,1998, from L. Joseph Callan, Executive Director for Operations, NRC, for the Commissioners,
Subject:
Rulemaking Plan for implementation of Revised Source Term at Operating Reactors.
4.
Memorandum dated September 4,1998, from John C. Hoyle, Secretary of the Commission, to L. Joseph Callan, Executive Director for Operations, NRC,
Subject:
Staff Requirements - SECY-98-158 - Rulemaking Plan for Implementation of Revised Source Term at Operating Reactors.
5.
Letter dated August 27,1996 from D. Shelton, Centerior Energy, to NRC,
Subject:
License Amendment Request: Revision of Main Steam Line Leakage Requirements and Elimination of the Main Steam isolation Valve Leakage Control System.
6.
U. S. Nuclear Regulatory Commission, NUREG-1465, " Accident Source Terms for Light-Water Nuclear Power Plants," February 1995.
7.
U.S. Nuclear Regulatory Commission, NUREG-1150, Vols.1 & 2, " Severe Accident Risks: An Assessment for Five U.S. Nuclear Power Plants," December 1990.
.