Category:NOTICE OF VIOLATION OF A REGULATION
MONTHYEARML20217N1491999-10-21021 October 1999
[Table view]Notice of Violation from Insp on 990720-29.Violation Noted: as of July 1999,licensee Did Not Take Adequate Measures to Assure That Condition Adverse to Quality Involving Macro Biological Fouling of Service Water System Corrected ML20207E0761999-02-25025 February 1999 Notice of Violation from Insp on 981227-990206.Violation Noted:Licensee Failed to Promptly Identify & Correct Condition Adverse to Quality in That Investigation of Improperly Calibr Channnels Was Incompleted ML20206U3141999-02-0505 February 1999 Notice of Violation from Insp on 981116-1217.Violation Noted:On or Before 981217,design Control Measures Were Not Established to Ensure That Design Basis Closing Voltage Requirements of Circuit Breakers Were Met & Verified ML20151Z3181998-09-15015 September 1998 Notice of Violation from Insp on 980628-0815.Violation Noted:On 980808,inspectors Observed Maint Supervisor Manipulate Outboard Pump Packing Supply Valve & Perform Maint by Adjusting Outboard Packing Gland Nuts ML20236X8661998-08-0505 August 1998 Notice of Violation from Insp on 980426-0627.Violation Noted:From 1988 to Sept 1997,licensee Routinely Vented Units 1 & 2 HHSI Piping Prior to Surveillance Testing W/O Proper Controls to Evaluate Amount of Gas.No Response Required ML20236X8631998-08-0505 August 1998 Notice of Violation from Insp on 980426-0627.Violation Noted:During Period of 980428-0608,licensee Failed to Implement Procedures as Evidenced by Listed Examples ML20217F5881998-04-22022 April 1998 Notice of Violations from Insp on 980208-0321.Violations Noted:Conditions Adverse to Quality Were Not Promptly Corrected from Nov 1993 to March 1998,util Failed to Correct Known Unit 1 & 2 TS Deficiency in Timely Manner ML20217B9771998-03-17017 March 1998 Notice of Violation from Insp on 971228-980207.Violations Noted:Repair Activities for 2-1 Station Battery Were Not Properly pre-planned & Implemented ML20216E8071998-03-0909 March 1998 Notice of Violation from Insp on 980105-0212.Violations Noted:On 971218 Dl Implemented Change to Temporary Operating Procedure to Allow Operators to Control Cooldown & Heatup Rate of Reactor Coolant by Mean Other than by Regulating IR 07100116/20120271998-02-0404 February 1998 Notice of Violation from Insp on 971116-1227.Violation Noted:Licensee Had Not Tested 20 of 27 Direct Lines at Alternate EOF in Coraopolis,Pa ML20198K4761998-01-0606 January 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Between 1988 & 970912, Condition Adverse to Quality Existed at Unit 1 & 2,when Excessive Gas Accumulated in HHSI Pumps Suction Lines IR 07100005/20110151997-11-26026 November 1997 Notice of Violation from Insp on 971005-1115.Violations Noted:Workers,Found in Radiology Controlled Areas,Not Aware of Radiological Conditions in Work or Travel Areas ML20198S6351997-11-0707 November 1997 Notice of Violation from Insp on 970830-1004.Violation Noted:Licensee Changed QA Program Resulting in Reduction in Commitments in QA Program Description Previously Accepted by NRC W/O Prior NRC Approval ML20217P7731997-08-18018 August 1997 Notice of Violation from Insp on 970608-0719.Violation Noted:Previous Corrective Actions Inadequate in That on 970701,unplanned Engineered Safety Feature Actuation, Occurred During Troubleshooting Activities on Unit 1 ML20141G9971997-07-0303 July 1997 Notice of Violation from Insp on 970209-0426.Violation Noted:During EDG Surveillance Tests,Load Test Values Used Were Inadequate to Ensure That EDGs Achieved 2750 Kw Due to Inaccuracies in Kilowatt Meter Instrument Loop ML20141E9391997-06-23023 June 1997 Notice of Violation from Insp on 970427-0607.Violation Noted:On 970515,operators Failed to Properly Certify Shift Operating Log Accuracy for Shift Turnover ML20137F3921997-03-24024 March 1997 Notice of Violation from Insp on 961222-970208.Violations Noted:When Repeatedly Depressurizing Unit 2 RHR Sys from 970123-30,operators Did Not Properly Implement Procedures as Required ML20147F1271997-03-10010 March 1997 Notice of Violations & Proposed Imposition of Civil Penalties in Amount of $160,000.Violations Noted:Licensee Did Not Provide Adequate Measures to Verify Selection of Suitable Leak Sealant Matl for Use in Leak Repair ML20135B7381997-02-21021 February 1997 Notice of Violation from Insp on 961222-970208.Violation Noted:As of 970201,licensee Never Installed Rms in Plan,Unit 1 Nfsas Capable of Alarming Should Accidental Criticality Occur ML20134K2471996-11-0808 November 1996 Notice of Violation from Insp on 960813-0928.Violations Noted:Safeguards Info Not Adequately Protected IAW Listed Procedures ML20058H2971993-12-0606 December 1993 Notice of Violation from Insp on 931018-22.Violations Noted:On 920405,7/8 body-to-bonnet Studs Were Not Torqued to 340 ft-lbs as Required in Table 1 of Licensee Procedure 2CMP-75-FISHER VLV-1M,Issue 4,Rev O,Per 10CFR50,App B ML20058M7891993-11-14014 November 1993 Notice of Violation from Insp on 931026-1127.Violation Noted:Licensee Failed to Establish Adequate Design Control Measures for Installation Specification of Reactor Coolant Sys RTDs ML20058Q0381993-10-15015 October 1993 Notice of Violation from Insp on 920908 & 930720.Violation Noted:Licensee Determined That Records Required to Be Maintained by Commission Regulations or License Conditions Not Complete & Accurate in All Matl Respects ML20057E8321993-10-0101 October 1993 Notice of Violation from Insp on 930824-0927.Violation Noted:Requirements of TS Were Not Satisfied as Evidenced by Listed Examples ML20248G0081989-09-29029 September 1989 Notice of Violation from Insp on 890523-0707.Violation Noted:Approx 90 Measuring & Test Devices Past Due for Calibr & Not Properly Marked & Segregated from Calibr Measuring & Test Devices as Required by Procedure ML20246A9861989-08-11011 August 1989 Notice of Violation from Insp on 890523-0707.Violations Noted:Licensee Corrective Actions in Response to Findings Identified in Insp Rept 88-22,Detail 10 Re Electrical Cable Inadequate ML20245C5471989-04-19019 April 1989 Notice of Violation from Insp on 890216-0331.Violation Noted:On 890322,inadvertent Safety Injection Occurred Due to Procedural Inadequacies in That Procedures Not Appropriate for Circumstances ML20205K6521988-10-20020 October 1988 Notice of Violation from Insp on 860609-13 & 880509-13. Violations Noted:Qualification of Victoreen High Range Radiation Monitor Cable Assembly Not Established & Unqualified Wire Jumper in MOV-RW-105D Identified ML20154P8171988-09-23023 September 1988 Notice of Violation from Insp on 880716-0831.Violation Noted:Defect Identified in Three Containment Isolation Valves Not Analyzed Until 10 Months After Receipt of Documentation ML20151U5591988-08-12012 August 1988 Notice of Violation from Insp on 880601-0715.Violation Noted:Outer Periphery of Cable Group in Tray 1TC545 Not Separated by at Least 6 Inches from Outer Periphery of Redundant Cable Group in Tray 1TC306B ML20207C9111988-08-0303 August 1988 Notice of Violation from Insp on 880509-13.Violation Noted: Equipment Qualification File 0044,Rev 3 for motor-operated Valve MOV-S1-885B Did Not Have Sufficient Documentation to Establish Qualification of Ideal Model Wirenuts ML20196D4651988-06-21021 June 1988 Notice of Violation from Insp on 880509-13.Violation Noted: Contrary to Tech Spec 6.11,air Sample Paper Found to Indicate 2,400 Ncpm & Supervision Not Notified in Order to Determine If Immediate Corrective Actions Needed ML20154D9411988-05-12012 May 1988 Notice of Violation from Insp on 880321-0401.Violation Noted:Acceptability of Emergency Diesel Generator Starting Air Sys Seismic Supports Degraded Due to Loose Bolts ML20153G4011988-04-28028 April 1988 Notice of Violation from Insp on 880303-08.Violation Noted: Failed to Maintain Required Number of Operable hi-hi Containment Pressure Channels While Reactor Was in Hot Shutdown,Startup or Power Operation Modes ML20151G5631988-04-0808 April 1988 Notice of Violation from Insp on 880222-26.Violation Noted: on 870908 Shipment Number 0951 of Radwaste Sent to Supercompacting Facility & Accompanied by Manifest Which Did Not Identify Existence & Quantities of Radwaste in Shipment ML20150B5251988-03-0404 March 1988 Notice of Violation from Insp on 880125-29.Violation Noted: on 880126,radiological Controls Technician Entered Unit 1 Containment While Not Dressed in Accordance W/Min Anticontamination Clothing Requirements ML20236H2531987-07-29029 July 1987 Notice of Violation from Safety Insp on 870605-17. Violations Noted:All Three Chlorine Detection Sys Inoperable & Design Changes Re Chlorine Detection Sys Inadequate ML20216A9481987-06-18018 June 1987 Notice of Violation from Insp on 870406-15 & 0507-08 ML20216G4861987-06-17017 June 1987 Notice of Violation from Insp on 870418-0604 ML20215K1511987-06-16016 June 1987 Notice of Violation from Insp on 870316-26 ML20214Q8471987-05-28028 May 1987 Notice of Violation from Insp on 870316-0417 ML20215M0051987-05-0606 May 1987 Notice of Violation from Insp on 870301-0412 ML20215J0181987-04-28028 April 1987 Notice of Violation from Insp on 860929-1003.Violation Noted:Util Did Not Adequately Describe Corrective Actions Taken & Provide Sufficient Info to Permit Analysis & Evaluation of Deficiency ML20205T4941987-03-31031 March 1987 Notice of Violation from Insp on 870201-0315 ML20207S2491987-03-12012 March 1987 Notice of Violation from Insp on 870117-0228 ML20211E9291987-02-13013 February 1987 Notice of Violation from Insp on 861215-19 & 870105-09 ML20212R6071987-01-23023 January 1987 Notice of Violation from Insp on 861208-11 ML20214H6171986-11-19019 November 1986 Notice of Violation from Insp on 861004-1102 ML20214C7941986-11-17017 November 1986 Notice of Violation from Insp on 860930-1003 ML20207B2051986-11-0404 November 1986 Notice of Violation from Safety Insp on 861006-10 1999-02-05 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARPNO-I-99-048, on 991022,operators Initiated Plant Shutdown from 100% Reactor Power,Due to Continued RCS Leakage Through B Pressurizer Code Safety Valve to Primary Relief Tank. Operators Are Reducing Reactor Power at 12% Per H1999-10-22022 October 1999
[Table view]PNO-I-99-048:on 991022,operators Initiated Plant Shutdown from 100% Reactor Power,Due to Continued RCS Leakage Through B Pressurizer Code Safety Valve to Primary Relief Tank. Operators Are Reducing Reactor Power at 12% Per H ML20217N1491999-10-21021 October 1999 Notice of Violation from Insp on 990720-29.Violation Noted: as of July 1999,licensee Did Not Take Adequate Measures to Assure That Condition Adverse to Quality Involving Macro Biological Fouling of Service Water System Corrected IR 05000334/19990061999-10-0707 October 1999 Insp Repts 50-334/99-06 & 50-412/99-06 on 990809-13 & 990823-27.Violations Noted.Major Areas Inspected:Licensee Corrective Action Program Implementation IR 05000334/19990051999-09-30030 September 1999 Insp Repts 50-334/99-05 & 50-412/99-05 on 990725-0904.Two Violations Noted & Being Treated as Nvcs.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support ML20211Q5791999-09-0707 September 1999 Insp Rept 50-412/99-07 on 990720-29.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000334/19990041999-08-24024 August 1999 Insp Repts 50-334/99-04 & 50-412/99-04 on 990613-0724. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support PNO-I-99-036, on 990718,update to Beaver Valley,Unit 2 Forced Outage Made.Licensee Replaced Suspected Voltage Regulator Control Relays & Satisfactorily Retested EDG 2-2.Resident Inspectors Continue to Monitor Licensee Corrective Action1999-07-26026 July 1999 PNO-I-99-036:on 990718,update to Beaver Valley,Unit 2 Forced Outage Made.Licensee Replaced Suspected Voltage Regulator Control Relays & Satisfactorily Retested EDG 2-2.Resident Inspectors Continue to Monitor Licensee Corrective Action PNO-I-99-033, on 990716,apparent Electrical Fault Occurred During EDG Full Load Test,Which Opened Supply Breaker Between Emergency & Normal 4 Kilovolt Busses.Station Personnel Intend to Resolve & Correct Electrical Fault1999-07-19019 July 1999 PNO-I-99-033:on 990716,apparent Electrical Fault Occurred During EDG Full Load Test,Which Opened Supply Breaker Between Emergency & Normal 4 Kilovolt Busses.Station Personnel Intend to Resolve & Correct Electrical Fault IR 05000334/19990031999-07-0707 July 1999 Insp Repts 50-334/99-03 & 50-412/99-03 on 990502-0612.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support.Results of Y2K Readiness Assessment Also Included IR 05000334/19990021999-05-21021 May 1999 Insp Repts 50-334/99-02 & 50-412/99-02 on 990321-0501.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000334/19990011999-04-22022 April 1999 Insp Rept 50-334/99-01 & 50-412/99-01 on 990207-0320. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support.Also Results of Insp by Regional Security & Inservice Insp Specialists IR 05000412/19993011999-04-20020 April 1999 NRC Operator Licensing Exam Rept 50-412/99-301(including Completed & Graded Tests) for Tests Administered on 990322- 25.All Applicants Passed All Portions of Exams IR 05000334/19980111999-02-25025 February 1999 Insp Repts 50-334/98-11 & 50-412/98-11 on 981227-990206. Violations Noted.Major Areas Inspected:Operations,Maint & Plant Support ML20207E0761999-02-25025 February 1999 Notice of Violation from Insp on 981227-990206.Violation Noted:Licensee Failed to Promptly Identify & Correct Condition Adverse to Quality in That Investigation of Improperly Calibr Channnels Was Incompleted ML20206U3141999-02-0505 February 1999 Notice of Violation from Insp on 981116-1217.Violation Noted:On or Before 981217,design Control Measures Were Not Established to Ensure That Design Basis Closing Voltage Requirements of Circuit Breakers Were Met & Verified IR 05000334/19980091999-02-0505 February 1999 Insp Repts 50-334/98-09 & 50-412/98-09 on 981115-1217. Violations Noted.Major Areas Inspected:Engineering IR 05000334/19980101999-01-13013 January 1999 Insp Repts 50-334/98-10 & 50-412/98-10 on 981115-1226.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support.Matl Condition of Fire Protection Equipment Installed in Plant Was Excellent IR 05000334/19980061998-12-0404 December 1998 Corrected Pages 17 & 18 to Insp Repts 50-334/98-06 & 50-412/98-06,correcting Errors on Subj Pages ML20196H2951998-12-0202 December 1998 Insp Repts 50-334/98-08 & 50-412/98-08 on 981026-30.No Violations Noted.Major Areas Inspected:Operations & Maint ML20196H3231998-12-0202 December 1998 Insp Repts 50-334/98-06 & 50-412/98-06 on 981004-1114.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support IR 05000334/19980071998-11-0505 November 1998 Insp Repts 50-334/98-07 & 50-412/98-07 on 981006-07.No Violations Noted.Major Areas Inspected:Performance of Emergency Response Organization IR 05000334/19980051998-10-23023 October 1998 Insp Repts 50-334/98-05 & 50-412/98-05 on 980816-1003. Apparent Violations Being Considered for Escalated Enforcement Action.Major Areas Inspected:Operations, Engineering,Maint & Plant Support ML20151Z3231998-09-15015 September 1998 Insp Repts 50-334/98-04 & 50-412/98-04 on 980628-0815. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20151Z3181998-09-15015 September 1998 Notice of Violation from Insp on 980628-0815.Violation Noted:On 980808,inspectors Observed Maint Supervisor Manipulate Outboard Pump Packing Supply Valve & Perform Maint by Adjusting Outboard Packing Gland Nuts IR 05000334/19983011998-08-21021 August 1998 Exam Repts 50-334/98-301OL & 50-412/98-301OL Conducted During Wks of 980803-07 & 17-21.Exam Results:Four Unit 2 SRO Candidates Passed All Portions of Initial Exam.Good Performance Noted During Exam in Area of Crew Communication ML20236X8661998-08-0505 August 1998 Notice of Violation from Insp on 980426-0627.Violation Noted:From 1988 to Sept 1997,licensee Routinely Vented Units 1 & 2 HHSI Piping Prior to Surveillance Testing W/O Proper Controls to Evaluate Amount of Gas.No Response Required IR 05000334/19980031998-08-0505 August 1998 Insp Repts 50-334/98-03 & 50-412/98-03 on 980426-0627. Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering,Maint & Plant Support ML20236X8631998-08-0505 August 1998 Notice of Violation from Insp on 980426-0627.Violation Noted:During Period of 980428-0608,licensee Failed to Implement Procedures as Evidenced by Listed Examples IR 05000334/19983001998-06-0303 June 1998 Exam Rept 50-334/98-300OL Conducted on 980420-24 & 0518.Exam Results:Three SRO Instant Candidates Passed All Portions of Initial License Exam ML20217F5881998-04-22022 April 1998 Notice of Violations from Insp on 980208-0321.Violations Noted:Conditions Adverse to Quality Were Not Promptly Corrected from Nov 1993 to March 1998,util Failed to Correct Known Unit 1 & 2 TS Deficiency in Timely Manner ML20217F5951998-04-22022 April 1998 Insp Repts 50-334/98-01 & 50-412/98-01 on 980208-0321. Violations Noted.Major Areas Inspected:Operations, Engineering,Maint & Plant Support ML20217B9771998-03-17017 March 1998 Notice of Violation from Insp on 971228-980207.Violations Noted:Repair Activities for 2-1 Station Battery Were Not Properly pre-planned & Implemented ML20217B9851998-03-17017 March 1998 Insp Repts 50-334/97-11 & 50-412/97-11 on 971228-980207. Violations Noted.Major Areas Inspected:License Operations, Engineering,Maint & Plant Support.Security Program Was Also Inspected ML20216E8071998-03-0909 March 1998 Notice of Violation from Insp on 980105-0212.Violations Noted:On 971218 Dl Implemented Change to Temporary Operating Procedure to Allow Operators to Control Cooldown & Heatup Rate of Reactor Coolant by Mean Other than by Regulating ML20216E8191998-03-0909 March 1998 Insp Repts 50-334/98-80 & 50-412/98-80 on 980105-0212. Violations Noted.Major Areas Inspected:Evaluation of Implementation of 10CFR50.59 SE Program Relating to Changes, Tests or Experiments at Plant ML20202A9691998-02-0404 February 1998 Insp Repts 50-334/97-09 & 50-412/97-09 on 971116-1227. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support.Rept Also Includes Results of Announced Insp in Areas of Emergency Preparedness IR 07100116/20120271998-02-0404 February 1998 Notice of Violation from Insp on 971116-1227.Violation Noted:Licensee Had Not Tested 20 of 27 Direct Lines at Alternate EOF in Coraopolis,Pa PNO-I-98-002, on 980130,operators Declared Both Trains of Component Cooling Reactor & Reactor Plant River Water Sys Inoperable Due to Failure to Meet TS Surveillance Testing Requirements.Entered TS 3.0.3 & 4.0.31998-02-0202 February 1998 PNO-I-98-002:on 980130,operators Declared Both Trains of Component Cooling Reactor & Reactor Plant River Water Sys Inoperable Due to Failure to Meet TS Surveillance Testing Requirements.Entered TS 3.0.3 & 4.0.3 IR 05000334/19970101998-01-0909 January 1998 NRC Operator Licensing Exam Rept 50-334/97-10OL (Including Completed & Graded Tests) for Tests Administered on 971215- 18 ML20198K4761998-01-0606 January 1998 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:Between 1988 & 970912, Condition Adverse to Quality Existed at Unit 1 & 2,when Excessive Gas Accumulated in HHSI Pumps Suction Lines ML20199A1711997-12-31031 December 1997 EN-97-119:on 980106,notice of Proposed Imposition of Civil Penalty in Amount of $55,000 Issued to Licensee.Action Based on Violation Involving Failure to Take Adequate Action to Correct Significant Condition Adverse to Quality PNO-I-97-077, on 971216,Duquesne Light Co Initiated Unit 2 Reactor Shutdown in Accordance W/Ts 3.0.3.Licensee Plans to Address Unit 2 Design Deficiency for CR Emergency Air Cleanup & Pressurization,During Shutdown1997-12-17017 December 1997 PNO-I-97-077:on 971216,Duquesne Light Co Initiated Unit 2 Reactor Shutdown in Accordance W/Ts 3.0.3.Licensee Plans to Address Unit 2 Design Deficiency for CR Emergency Air Cleanup & Pressurization,During Shutdown ML20203D7421997-11-26026 November 1997 Insp Repts 50-334/97-08 & 50-412/97-08 on 971005-1115. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 07100005/20110151997-11-26026 November 1997 Notice of Violation from Insp on 971005-1115.Violations Noted:Workers,Found in Radiology Controlled Areas,Not Aware of Radiological Conditions in Work or Travel Areas IR 05000334/19970071997-11-0707 November 1997 Insp Repts 50-334/97-07 & 50-412/97-07 on 970831-1004. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20198S6351997-11-0707 November 1997 Notice of Violation from Insp on 970830-1004.Violation Noted:Licensee Changed QA Program Resulting in Reduction in Commitments in QA Program Description Previously Accepted by NRC W/O Prior NRC Approval IR 05000334/19970061997-09-18018 September 1997 Insp Repts 50-334/97-06 & 50-412/97-06 on 970720-0830.No Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support & Licensed Operator Requalification Training Program ML20217P7731997-08-18018 August 1997 Notice of Violation from Insp on 970608-0719.Violation Noted:Previous Corrective Actions Inadequate in That on 970701,unplanned Engineered Safety Feature Actuation, Occurred During Troubleshooting Activities on Unit 1 IR 05000334/19970051997-08-18018 August 1997 Insp Repts 50-334/97-05 & 50-412/97-05 on 970608-0719. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support ML20141G9971997-07-0303 July 1997 Notice of Violation from Insp on 970209-0426.Violation Noted:During EDG Surveillance Tests,Load Test Values Used Were Inadequate to Ensure That EDGs Achieved 2750 Kw Due to Inaccuracies in Kilowatt Meter Instrument Loop 1999-09-07 |
Text
q ,
-.- s APPENDIX A NOTICE OF VIOLATION Duquesne Light Company Docket No. 50-334 Beaver Valley Power Station, Unit 1 License No. DPR-66 As a result of the inspection conducted on March 11 thru April 18, 1986, and in accordance with the " General Statement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2,. Appendix C (1985), the following violations were identi-fied:
A. Technical Specification 4.3.3.5 requires remote shutdown monitoring instru-mentation channel TRB-RH-606, RHR Temperature - HX Outlet, to be demonstrated operable by performance of a monthly channel check. Technical Specification 1.10 defines channel check as a qualitative assessment of channel behavior-during operation by observation.
Contrary to the above, the monthly remote shutdown monitoring instrumentation channel check failed to qualitatively assess TRB-RH-606 as inoperable from December 25, 1985 to March 19, 1986, when indicated readings were off-scale low (less than 50 F) at less than expected ambient temperature (70-80 F).
This is a Severity Level IV Violation (Supplement I).
B. Technical Specification 4.3.3.6.1 requires that the fire detection instrumen-tation accessible during normal plant operation for each fire detection zone listed-in Table 3.3-10 shall be demonstrated operable at least once per six' months by performance of a channel functional test. A channel functional test, as defined by Technical Specification 1.11, is the injection of a simulated signal into the channel as close as practical to the sensor (detector) to verify operability including alarm and/or trip functions.
Contrary to the above, on March 26, 1986, it was determined that implementa-tion of OST 1.33.16, Smoke Detector Instrumentation Test, on the smoke detec-tion system in the No. 2 Diesel Generator Room, failed to demonstrate indivi-dual detector operability in that a complete channel functional test was et performed to verify the control room alarm function for each detector. Du; to inadequate testing, the licensee was unaware that detector D100 was in-operable between January 7,1985 and March 26, 1986.
This is a Severity Level IV Violation (Supplement I).
Pursuant to the provisions of 10 CFR 2.201, Duquesne Light Company is hereby re-quired to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement or explanation in reply, including (1) the corrective steps which have been taken and the results achieved; (2) cor-rective steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved. Where good cause is shown, consideration will be given to extending this response time.
~