Corrected Effluent & Waste Disposal Semiannual Rept,Solid Waste & Irradiated Fuel Shipments,Jul-Dec 1982
ML20197B185
Person / Time
Site: Farley  
Issue date: 12/31/1982
From:
ALABAMA POWER CO.
To:
Shared Package
ML20197B175 List:
References
NUDOCS 8610280114
Download: ML20197B185 (2)


Text

.

4 TABLE 3 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT (1982)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.

SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel) 1.

Type of Waste U!iITS PERIOD July 1-Dec.31 3

a.

Spent resins, filter sludges, m

9.627E 00 evaporator bottoms, etc.

'Ci 3.230E 00 3

b.

Dry compressible waste, m

1.632E 02 l

contaminated equipment, etc.

Ci 6.020E 01 3

c.

Irradiated components, m

None control rods, etc.

Ci None 3

d.

Other (described) m

'None Ci None 2.

Estimate of major nuclide composition ISOTOPES Ci ISOIOPES Ci a.

Nb-95 5.9E-01 1.917E-02 Ba-140 1.6E 00 5.325E-02 I-131 1.2E 01 4.147E-01 Na-24 1.4E-01 4.400E-03 Cs-134 7.2E 00 2.334E-01 Co-57 1.6E 00 5.325E-02 Co-60 4,3E 01 1.403E 00 La-140 2.2E 00 7.092E-02 Cs-137 1.2E 01 3.940E-01 Co-58 1.3E 01 4.089E-01 Mn-54 5.5E 00 1.789E-01 b.

Cr-51 1.2E 01 7.259E 00 Mn-54 3.2E 00 1.932E 00 I-131 6.6E 00 3.957E 00 Fe-59 5.6E-01 3.360E-01 Cs-134 6.2E 00 3.957E 00 Co-60 3.3E 01 2.001E 01 Cs-137 1.6E 00 9.708E-01 La-140 1.9E-01 1.120E-01 Zr-95 1.6E 00 9.335E-01 Nb-95 2.4E-01 1.415E-01 Co-58 4.0E 01 2.418E 00 egR102OO114 860714 ADOCK 05000348 g

PDR

TABLE 3 (con't)

EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT (1982)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS 3.

Solid Waste Disposition a.

Number of Shipments 13 b.

Mode of Transportation Chem-Nuclear Transport (11) l Hittman Transport (2) c.

Destination Chem-Nuclear Systems, Inc.

Barnwell, South Carolina 4.

Type of Containers a.

( la )

170 cf. steel liners (dewatered resin & charcoal media) 120 cf. High Integrity Containers

( Spent filters )

55 cf. High Integrity Containers

( Spent filters )

b.

( lb )

55 gallon steel drum 112 cf. wooden boxes 5.

Solidification Agents a.

( la )

No solidifications during this report period. All items (spent resin and charcoal) that are i

catagorized item la were shipped dewatered.

b.

( lb )

N/A B.

IRRADIATED FUEL SHIPMENTS (Disposition) 1.

Number of Shipments None 2.

Mode of Transportation N/A 3.

Destination N/A I

l 33