DRESDEN NUCLEAR POWER STATION DOCKET NOS. 50-10, 50-237, 50-249 MEASUREMENTS AND APPROXIMATIONS A.

rission and activation gases: The D-1 chimney and D2/3 chimney are sampled daily via a grab sample. The D-2 and D-3 Reactor Vents are sampled weekly via a grab sample. The samples are analysed for specific isotcpes present in the release using a Ge(L1) spectrometry system. Tritium is collected via a continuous sample on the D-2/3 l.

chimney and via a grab sample on the D2/3 Reactor Vent and analysed using a Liquid Scintillation Counter.

Kr-85 is estimated in the D2/3 chimney using a recoil or non-recoil calculation using fission /sec.

plot and the sum of Xe-138, Kr-87, Kr-88, Kr-85m, Xe-133 and Xe-135 j

activities.

B.

Iodine and Particulate Iodine and particulate samples from the D-1 and D2/3 Chimney and the D-2 and D-3 Reactor Vents are collected for a seven day period. These samples are analysed for specific nuclides present in the release using a Ge(Li) spectrometry system. When particulate samples are not used for reporting the release rate due to management decision that the sample may not be representative, an average of the preceding sample and the following sample is used to calculate the release.

A monthly composite is sent to a vendor to be analysed for Sr-89, St-90, and Gross Alpha activity.

+

C.

Liquid Effluents:

Prior to a release duplicate grab samples are collected from each batch and analysed for gross activity using a gas flow proportional counter.

Rad-waste batch discharges are also analysed for specific isotopes present in the release using a Ge(L1) i spectrometry system. A composite of all batches for the month is sent to a vendor to be analysed for Sr-89, Sr-90, re-55, and Gross Alpha. One of the LPCI samples for each month is analysed for specific isotopes present in the releases using a Ge(L1) spectrometry i

system. This sample is sont to a vendor to be analysed for St-89, St-90, re-55, and Gross Alpha activity.

1 i

I.

Page 1 of 15 1981a I

/

9808170321 8 ADOCK O gO gor ff

DRESDEN NUCLEAR PoltER STATION t

EFFLUENT AND NASTE DISPOSAL SEMIANNUAL REPORT

' Januarv - Through Ja==

1911 GASEOUS EFFLUENTS i

SUMATION OF ALL RELEASES I

Docket Numbers: 50-10 50-237 50-249 f

t UNIT 131 QUAkTER 2nd QUARTER l

r A.. FIRSICM AMD ACTIVATICM GARES.

[

1.

Total Release C1 1.14 E02 4.74 E01 2.

Average Release Rate for Period uC1/sec 1.45 E01 6.03 E00 j

3.

Percent of Technical Specification Liisit i

B.. _. IQQiusts Ci 7.04 E-02 8.78 E-03 1.

Total Iodine-131 2.

Average Release Rate for Period uCi/sec 8.95 E-03 1.11 E-03 3.

Percent of Technical Specification Limit I

I i

C.

PARTICULATEE 1.

Particulates with half lives > 8 days C1 1.29 E-02 2.35 E-03 l

2.

Average Release Rete for Period uC1/sec 1.64 E-03 2.99 E-04 3.

Percent of Technical Specification Limit i

4.

Gross Alpha Radioactivity Ci 5.92 E-10

<MDL

n. TarTitas 1.

Total Release Ci 9.82 E00 2.75 E00 3.

Average Release Rate for Period uC1/sec 1.25 E00 3.50 E-01 i

j 4

3.

Percent of Technical Specification Limit i

f O Will be included in the Annual R yort on Environmental Radioactivity Data

[

[

i

{

Page 2 of 15

(

l 1981a j

l i

I

?

DRESDEM NUCLEAR PON3R STATION EFFLUENT AND NASTE DISPOSAL SENIANNUAL REPORT

._ January Through Juaa 1911 Di Chl=nay GASEOUS EFFLUENTS GROUND LEVEL RELEASES Docket Number 50-10 SKMI-ELEVATED RELEASES.

l xx ELEVATED RELEASES CCaiTINUOUS MODE BATCH MODE NUCLIDES RELEASED UNIT 131 QUARTER Ind QUARTER 121 QUARTER Ind QUARTER

_.. F15510M GAEEE.._C1 Ee-133 Ci Ee-135m C1 Er-87

_C1_

J g-ts C1

_ eu e e Er-35m C1 Er-85 Cl e

Me-135 Ci e

Xe-113 C1 e

0+harg11e-133a C1 C1

TOTAf,

_qi None.

Mone 10 DINES

-- l _131 C1 1-333 C1 I-135

_Cl TOTAL C1 None Nane EARIlCULATES dr-39 C1 II.- 9 0 C1 Cr-51 C1 Mn-14

_CL Co-58 C1 e

i Fe-59 Cl

,_ Co-E0 Cl 6.68 E-06 3.07 E-06 3g.95

_Cl_

Mh 95

_C1

- - EnL.103 C1 e

Aa_110m C1 Eh-124

_C1 e

I-131 Cl Ca-134 Ci 3 19 E-07 I

ca-136 C1 C3-137 ll_Jd6. E-06 2.81 E-05 atdA0 C1 Ct.141 ll Cad (.4 C1

_. _.__ Z n - 6 5 31_

Ba-133 C1 Sb-125 Ci e

I ctherg1_Modg__C1_

La-Itg....cl C1 C1 j-Ci TQTAL C1 1.q5 E-05 3.15 E-Q5 None None

  • See Table for MDL of Each Nuclide Page 3 of 15 1981a

DRESDEN NUCLEAR POWER STATION EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

_-Jtnuary__ Thrcugh June 1911 Docket Number 50-10 TABLE OF MINIMUM DETECTABLE LEVELS FOR GASEOUS EFFLUEN7S Di chimney __ GASEOUS EFFLUENTS AVERAGE FLOW 50.000 cfm HDL (uC1/cc) s or TIME < MDL 1.

FISSION GASES Xe-138 4.16 E-08 100.0 Xe-135m 1.29 E-07 100.0 Kr-87 3.03 E-08 100.0 Kr-88 5.21 E-08 100.0 Kr.85m 1.78 E-08 100.0 Kr-85 4.43 E-06 100.0 Xe-135 1.52 E-08 100.0 Xe-133 4.32 E-08 100.0 Others:

2.

IODINES I-131 5.34 E-14 100.0 I-133 5.57 E-14 100.0 I-135 1.19 E-13 100.0 3.

PARTICULATES Sr-89 2.5 E-14 100.0 St-90 1.5 E-14 100.0 Cr-51 4.20 E-13 100.0 Hn-54 5.27 E-14 100.0 Co-58 4.83 E-14 100.0 Fe-59 7.58 E-14 100.0 Co-60 1.26 E-13 15.9 Zr-95 9.09 E-14 100.0 Hb-95 4.96 E-14 100.0 Ru-103 4.95 E-14 100.0 Ag-110m 5.12 E-14 100.0 Sb-124 5.86 E-14 100.0 I-131 5.15 E-14 100.0 Cs-134 5.73 E-14 92.3 Cs-136 5.49 E-14 100.0 Cs-137 6.21 E-14 7.7 Ba.140 1.91 E-13 100.0 Co 141 7.64 E-14 100.0 Co-144 3.27 E-13 100.0 Zn-65 9.03 E-14 100.0 Ba-133 6.93 E-14 100.0 Sb-125 1.39 E-13 100.0 Others:

Page 4 of 15 1981a I

n

~

DRESDEN NUCLEAR POWER STATICBI EFFLUENT AND NASTE DISPOSAL SEMIANNUAL REPORT

_ January. Thrcugh Jun.

1931

~

D2/3 Chimney _

GASEOUS EFFLUENTS GROUND LEVEL RELEASES Docket Numbers: 50-237

'i SEMI-ELEVATED RELEASES.

50-249

):

um ELEVATED RET, EASES C NTINUQQB,MQDE RATCN MODE NUCLIDES RELEASED UNIT 131 QUARTER 2nd QUARTER lat QUARTER 2nd QUARTER FISSIW GARE8_Ji Ka-138 C1 1.13 E01

-- 18.135m

_Ci 6.66_gQ0 3

Er-87 C1.

Er-RA C1 1.64 E00 Jr-asa ci a.64 E-01 Er-85 JL 5.26 E-05 13-135 Ci 5.74 E01 1,18 E01 1e-133 C1 1.11 E01 1.64 E00

_ 9theIsi

_C1.

Cl i

TOTAL _ _

C1 1.0L 502 1.79 E01 None None 1

JDDIMES I-131 C1 3.25 E-03 4.99 E-04 l

_I-133 C1 1.49 E-02 2.71 E-03 I

I-135 C1 2.31 E-02 5.11 E-03

"'OTAL C1 4.13 E-02 8.52 E-03 None None PARILCULATES Er-89 C1 1.,21 E-07 C.80 E-09 gr-90 C1 6.33 E-10 Cr 51

__C i Mn-54 C1 2 g2 E-05 2.21 E-05 t

l Co-58 C1 Fe-59

_Cl Co-60

..CL.,

4.51 E-04 1.13 E-04

___,_g r - 9 5

_CL Mh-95 C1_

AnL 101

__ C i An-110m Ci e

Eh-114 Ci I-111

_CL ttgi E 04

_6.33 E-05 Ca-134 C1 Ca-136 C1 Ca-137 C1 7.95 E-05 5.4A C-05

-. 3&-1(l8

_C1_

2.89 E-03 2.86 E-04 Cg_l(1

_ C1.

3.03 E-06 4x20 E-05 Ce-144 CL Kkd5 Cl Ba-133 C1 Sb-115

_ C L__

Othat11_Mo-99 Ci e

Lad 4L_C1._

I Ci i

ci

. C1 l

TUIAL

!_CL (1 led 3 6.10_E-04 None None

  • See Table for MDL of Each Nuclide 4

Page 5 of 15 1981a t

1

., _1

DRESDEN ITUCLEAR POWER STATION Docket Numbers:

~

50-237 TABLE OF HINIMUM DETECTABLE LEVELS 50-249 F0h GASEOUS EFFLUENTS 1st qtr 283 Kcfr.

AVERAGE FLOW 2nd qtr 305 Kcfm D2/3 Chimney GASEOUS EFFLUENTS BDL (uC1/cc)

% OF TIME < MDL 1.

FISSION GASES Xe-138 4.16 E-08 92.3 Xe-135m 1.29 E-07 97.3 Kr-87 3.03 E-08 100.0 Kr-88 5.21 E-08 99.5 Kr-85m 1.78 E-08 99.5 Kr-85

(.43 E-06 0.0 Xe-135 1.52 E-08 49.5 Xe-131 4.32 E-08 96.2 Others:

2.

IODINES I-131 5.34 E-14 0."

I-133 5.57 E-11 38.b I-135 1 19 E-13 24.2 3.

PARTICULATES Sr-89 2.5 E-14 0.0 Sr-90 1.5 E-14 50.0 Cr-51 4.20 E-13 100.0 Mn-54 5.27 E-14 36.5 Co-58 4.83 E-14 100.0 Fe-59 7.58 E-14 100.0 Co-60 1.26 E-13 3.3 Zr-95 9.09 E-14 100.0 Nb-95 4.96 E-14 100.0 Ru-103 4.95 E-14 100.0 Ag-110m 5.12 E-14 100.0 Sb-124 5.86 E-14 100.0 I-131 5.15 E-14 16.5 Cs-134 5.73 E-14 100.0 C3-136 5.49 E-14 100.0 Cs-137 6.21 E-14 40.7 Ba-140 1.91 E-13 9.3 Co-141 7.64 E-14 94.0 Ce-144 3.27 E-13 100.0 Zn-65 9.03 E-14 100.0 Ba-133 6.93 E-14 100.0 Sb-125 1.39 E-13 100.0 Others:

Page 6 of 15 1981a

DRESDEN NUCLEAR POWER STAIION s

i

-EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT

_fangcry__. Thrcugh June 19H D2/3 Vent GASEOUS EFFLUENTS

=

GROUND LEVEL RELEASES Docket Numbers: 50-237 xx SEMI-ELEVATED RELEASES

  • 50-249 ELEVATED RELEASES CONTINUOUS MODE BATCH MOUZ NUCLIDES RCLEASED UNIT 131 QUARTER 2nd QUARTER lat QUARTER 2nd QUARTER FISSION GASES C1 X2-138 C1 Xe-135m Cl Kr-87 C1 Kr-88 Cl Kr-She Cl Kr-85 C1 Xe-135 C1 7.61 E00 2.24 E01 Xe-133 C1 7.14 E00 Otherst 01 Ci TOTAL C1 7.61 E00 2.95 E01 None None IOD.1HES I-131 Cl 7.59 E-02 6.67 E-05 I-133 C1.

9.59 E-03 1.91 E-04 I-135 C1 1.88 E-02 1.33 E-06 TOTAL C1 2.91 E-02 2.59 E-04 None None PARTICULATES Sr-89 C1 1.04 E-08 Sr-90 Cl 3 29 E-10 Cr-51 Ci 7.07 E-04 7.20 E-06 Mn-54 C1 2.69 E-04 5.88 E-04 Co-58 C1 2.82 E-04 2.64 E-05 Fa-59 Ci 7.38 E-05 3.72 E-05 Co-60 C1 2.27 E-03 1.60 E-03 Zr-95 C1.

7.80 E-05 Nb-95 C1 a

Ru-103 Cl Au-110m C1 1.57 E-05 1.19 E-06 Sb-124 C1 1.30 E-06 I-131 C1 6.21 E-04 2.35 E-06 Cm-134 C1 Cs-136 C1 5.58_E-06

[

Cs-137 Cl 7.37 E-06 1.24 E-05 Ba-140 C1_

4.67 E-04 Co-141 C1 Co-1(i

_C1_

3 1.4 E-06 I (0 E-04 4.76 E-06 Zn-65

_gi_

t Ba-133

_C1 Sb-125

_EL_

_.___Otherst Cl l

Mo-99 C1 3.61_E-03 C1 TOTAL

_C1 8.60 E-03 1.74 E-03 None None

  • See Table for MDL of Each Nuclide Pag' 7 of 15 1981a-

DRESDEN NUCLEAR POWER STATION January Thrcugh June 1911 Dsckct Numb 3rs:

50-237 TABLE OF MINIMUM DETECTABLE LEVELS 50-240 FOR GASEOUS EFFLUENTS D2:

110 Kcfm D2/3 Vent GASEOUS EFFL')ENTS AVERAGE FLOW D3:

110 Kcfm MDL (uC1/cc)

% OF TIME < MDL 1.

FISSION GASES Xe-138 4.16 E-08 100 Xe-135m 1.29 E-07 100 Kr-87 3.03 E-08 100 Kr-88 5.21 E-08 100 Kr-85m 1.78 E-08 100 Kr-85 4.43 E-06 100 Xe-135 1.51 E-08 51.1 Xe-133 4.3% E-08 96.2 Others:

2.

IODINES I-131 5.34 E-14 9.3 I-133 5.57 E-14 6.7 I-135 1.19 E-14 53.3 3.

PARTICULATES Sr-89 2.5 E-14 50.0 Sr-90 1.5 E-14 67.0 Cr-51 4.20 E-13 46.2 Mn-54 5.27 E-14 0.0 Co-58 4.83 E-14 0.0 Fe-59 7.58 E-14 23.6 Co-60 1.26 E-13 0.0 Zr-95 9.09 E.11 100.0 Nb-95 4.96 E-14 100.0 Ru-103 4.95 E-14 100.0 Ag-110m 5.12 E-14 65.4 Sb-124 5.86 E-14 96.2 I-131 5.15 E-14 41.2 Cs-134 5.73 E-14 100.0 Cs-136 5.49 E-14 88.5 Cs-137 6.21 E-14 34.1 Ba-140 1.91 E-13 50.0 Ce-141 7.64 E-14 100.0 Co-144 3.27 E-13 96.2 Zn-65 9.03 E-14 42.3 Ba-133 6.93 E-14 100.0 Sb-125 1.39 E-13 100.0 Others: Mo-99 3.95 E-13 50.0 Page 8 of 15 1981a

DRESDEN NUCLEAR POWER STATION EFFLUENT AND WAS13 DISPOSAL SEMIANNUAL REPORT January Through June 1911 LIQUID EFFLUENTS i

SUMMATION OF ALL RELEASES Docket Numbers: 50 50-237 50-249 UNIT lit QUARTER 2nd QUARTER A.

FISSICEI AND ACTIVATIN PRODUCTS

1. Total Release (not incl. tritium, gases, alpha)

C1 7.77 E-03 4.85 E-02

2. Average Diluted Conc. During Period uC1/mL 7.77 E-06 1.38 E-04
3. Percent of Applicable Limit B.

TRITIUM

1. Total Release C1 2.62 E00 1.08 E01
2. Average Diluted Conc. During Period uC1/mL 2.62 E-03 3.07 E-02
3. Percent of pplicable Limit C.

DISSQLYID__AND ENTRAINED GASES

1. Total Release Ci 3.02 E-04 2.05 E-04
2. Average Diluted Conc. During Period uC1/mL 3.02 E-07 5.82 E-07
3. Percent of Applicable Limit D.

CROSS ALPHA RADIOACTIVITY

1. Total Release Ci (MDL

<MDL E.

VOLUME OF WASTE RELEASED (prior to dilution) liters 1.00 E06 3.52 E05 F.

VOLUMW OF DILUTION WATER USED DURING PERIOD liters 1.16 E08 6.43 E07 0 Will be included in the Annual Report on Environmental Radioactivity Data Page 9 of 15 1981a

DRESDEN NUCLEAR POWER STATION E",TLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT January _ Through June _ 19H Madwaste LIQUID EFFLUENTS Docket Numbers: 50-10 50-237 1.

Number of Batch Releases: 183 50-249 2.

Total Time Period for Batch Releases: 58,633 min 3.

Maximum Time Period for a Batch Releases 447 min 4.

Average Time Period for Batch Releases: 320 min 5.

Minimum Time Period for a Batch Release:

11 min 6.

Average Stream Flow During Periods of Release of Effluent into a Flowing Stream: 8.57 E04 L/ min COITINUOUS MODE BATCH MODE NUCLIDES 'AELEASED UNIT ist QUARTER 2nd QUARTER lat QUARTER 2nd QUARTER Sr-89 C1 Gr-90 C1 h41 Ci Mn-S4 C1 2.99 E-04 5.12 E-03 Co-58 C1 Fe-59 Ci 7.20 E-05 Jh60 C1 4.71 E-03 3.72 E-02 Zn-65 Ci Ru-103 C1 Sb-122 Ci Sb-124 Ci I-131 C1 2.47 E-05 I-133 Ci I-135 Ci L's-134 C1 Cs-137 C1 2.55 E-03 5.97 E-03 Ba-140 Ci Lit-140 Cl Ce-141 Ci

.. _.. Others Fe-55 C1 Cr-51._

C1 1.00 E-04

_C1._-

C1 (above)

Total _Igr_Igriod C1 None None 7.69 E-03 4 d4 E-02--

Xa_-13 3 C1 1.79 E-04 1.36 E-04 Xe-115 C1 1.23 E-04 6.89 E-05

  • See Table for HDL of Each Nuclide Page 10 of 15 1981a

DRESDEN NUCLEAR POWER STATION

__J.anua ry Through June 1911 TABLE OF MINIMUM DETECTABLE LEVELS Docket Numbers:

FOR LIQUID EFFLUENTS 50-10 50-237 50-249-Radwasta LIQUID EFFLUENTS TOTAL GALLONS RELEASED 4,145.460 MDL (uCi/mL)

% OF GALLONS < MDL Sr-89 8.3 E-08 100.0 Sr-90 2.4 E-08 100.0 Ar-41 2.71 E-08 100.0 Mn-54 5.04 E-08 20.0 Co-58 4.98 E-08 100.0 Fe-59 8.11 E-08 99.5 Co-60 1.18 E-07 0.0 Zn-65 9.97 E-08 100.0 Ru-103 6.04 E-08 100.0 Sb-122 7.31 E-08 100.0 Sb-124 4.87 E-08 100.0 I-131 5.62 E-08 99.5 I-133 5.34 E-08 100.0 I-135 9.15 E-08 100.0 Cs-134 5.51 E-08 100.0 Cs-137 4.04 E-08 98.6 l

Da-140 2.11 E-07 100.0 La-140 3.82 E-08 100.0 1

Ce-141 9.33 E-08 100.0 Xe-133 1.53 E-07 91.5 Xe-135 5.13 E-08 89.1 Cr-51 4.81 E-07 99.3 Fe-55 3.1 E-07 100.0 Page 11 of 15 1981a i

DRESDEN NUCLEAR POWER STATICN EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT January-Through June 193.g LPCI LIQUID EFFLUENTS Docket Numbers: 50-237 50-249 3.

Number of Batch Releases:

97 2.

Total Time Period for Batch Releases: 120.3 min 3.

Maximum Time Period for a Batch Release: 1.24 min 4.

Average Time Period for Batch Releases: 1.24 min 5.

Minimum Time Period for a Batch Release: 1.24 rnin 6.

Average Stream Flow During Periods of Release of Effluent into a Flowing Stream: 1.50 E06 L/ min CONTINUOUS MODE BATCH MODE NUCLIDES RELEASED UNIT lit QUARTER 2nd QUARTER 131 QUARTER 2nd QUARTER

,__ Sr-89 C1 2.10 E-06 Sr-90 C1 3.20 E-07 Ar-41 C1 Mn-54 C1 1.64 E-06 1.08_E-05 Co-58 C1 Fe-59 C1 Cg-10 C1 6.29 E-05 1.30_E.04 Zn-65 C1 Ru-103 Ci Sb-122

.JL Sb-124 C1.

I-131 C1.

I-133 Ci I-115 C1 Cs-134 C1 j

Cs-137 C1 b64 E-Q.6

1. 61_Jl-Q S-._

Ba=140 Ci--

La-140 C1 Ce-lil Ci Others Cr-51 C1 Fe-55_.-.Ci -

C1_

_CL_

(above)

Intal _f_Qtlerlod_

_C 1__

None None 7.66 E-06 1.58 E-04.._

Xe-133

_,C1_

Xe-135 C1

  • See Tc.ble for MDL of Each Nuclide Page 12 of 15 1981a

c:

DRESDEN NUCLEAR PONER STATION January Through June 1911

}

TABLE OF MINIMUM DETECTABLE LEVELS Docket Numbers:

FOR LIQUID EFFLUENTS 50-237 50-249 LPCI LIQUID EFFLUENTS TOTAL GALLONS RELEASED 4.21 E05 MDI, (uC1/mL)

% OF GALLONS < MDL Sr-89 7.9 E-08 85.2 Sr-90 2.7 E-08 85.2 Ar-41 2.71 E-08 100.0 Mn-54 5.04 E-08 0.0 Co-58 4.98 E-08 100.0 Fe-59 8.11 E-08 100.0 Co-60 1.18 E-07 0.0 Zn-65 9.97 E-08 100.0 Ru-103 6.04 E-08 100.0 Sb-122 7.31 E-08 100.0 Sb-124 4.87 E-08 100.0 1-131 5.62 E-08 100.0 I-133 5.34 E-08 100.0 I-135 9.15 E-08 100.0 Cs-134 5.51 E-08 100.0 Cs-137 4.04 E-08 0.0 Ba-140 2.11 E-07 100.0 La-140 3.82 E-08 100.0 Ce -14.t 9.33 E-08 100.0 Xe-133 1.53 E-07 100.0 Xe-135 5.13 E-08 100.0 Cr-51 4.81 E-07 100.0 Fe-55 4.8 E-07 100.0 Page 13 of 15 1981a

DRESDEN NUCLEAR POWER STATION 4

5 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT January Through June 1911 Docket Numbers:

50-10 SOLID WASTE AND IRRADIATED TUEL SHIPMENTS 50-237 50-249 A.

SOLID WASTE SHIEEED OFFSITE FOR BURI AL OR DISPOSAL (NOT IRRID:: ATED TUEL)

1. Type of Waste Unit 6-month period a.

Spent resins, filter sludges, evaporator bottoms, etc.

Ci 7.18 E02 b.

Dry compressible waste, contaminated equip., etc.

C1 1.09 E01 c.

Irradiated components, control rods, etc.

C1 1.86 E00 d.

Other (describe)

C1

2. Estimato of Major Nuclide Composition (by type of waste) s C1 a.

Co-60 74.5 5.35 E02-Fe-55 12.4 8.90 E01 Mn-54 9.8 7.04 E01 Cs-137 0.7 5.03 E00 Other 2.6 1.87 E01 hu Co-60 24.4 2.66 E00 Fe-55 71.3 7.77 E00 Mn-54 2.8 3.05 E-01 Cs-137 1.4 1.53 E-01 Other 0.2 2.18 E-02 c.

Co-60 29.41 %

5.47 E-01 Fe-55 67.95 %

1.26 E00 Mn-54 2.64 %

4.91 E-02 4

d.

3. Solid Waste Disposition NUMBER OF SifIPMENTS MODE _DE_IRANSPORTATION DISTINAIloti 1

Motor freight (exclusive use only)

Chem-Nuclear, IL 42 Motor freight (exclusive use only)

Barnwell, SC l

16 Motor freight (exclusive use only)

SEG, TN 1

Motor freight (exclusive use only)

Quadrex, TN 2

Motor freight (exclusive use only)

Westinghouse-DRR, PA B.

IRRADIATED TUEL SHIPMENTS (Disposition)

HUMBIR OF SHIPMENIS 80DE_QI IRMISEDATATION DISIIHAT10N 1

Motor freight (exclusive use only)

Barnwell, SC Page 14 of 15 1981a

. -; e - -.

DRESDEN NUCLEAR POWER STATION EFFLUENT AND WAST 8 DISPOSAL SEMIANNUAL REPORT January Through June 1911 Docket Numbers:

50-10 ABNORMAL RELEASES 50-237 50-249 A.

LIQUID 1.

dumber of Releases:

None 2.

Total Activity Released:

Nong.

B.

GASEOUS 1.

Number of Releases None 2.

Total Activity Released:

None t

i l

15 of 15 1981a

4

~

N

/

Commonwealth Edison C

Dresden Nuclear Power Sttion C;.

R.R. #1 Morris, Illirds 60450 Telephone 815/942 2920 August 3, 1988 EDE LTR: 688-569 Mr. A. Bert Davis Regional Administrator Directorate of Int.pection and Enforcement Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 L

Subject:

Dresden Station Operating Report, NRC Dockets 50-10, 50-237, 50-249 Dear Mr. Davis Enclosed is the radioactive effluent report for Je.nuary through June 1988 for Dresden Nuclear Power Station.

one copy of each report is provided for your use and eight copies are being distributed per the rules and regulations outlined in the November 1986 Federal Register.

f Sincerely Yours, y

C c4*

E. D. Eeni rg Station Manager Dresden Nuclear Power Station EDE:JW jmt l

Enclosure cca J. Wallace J.C. Golden Filed 1RC

[

File / Numerical I