ML20151L165

From kanterella
Jump to navigation Jump to search
Forwards SER Accepting WCAP-10125, Extended Burnup Evaluation of Westinghouse Fuel, for Operation to Lead Rod Average Burnup Target.Conclusion Valid Only for Zircaloy- Clad Fuel.Tac 48689 Completed
ML20151L165
Person / Time
Issue date: 09/11/1985
From: Rubenstein L
Office of Nuclear Reactor Regulation
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML20151K563 List:
References
FOIA-86-78 TAC-48689, NUDOCS 8509180204
Download: ML20151L165 (1)


Text

,?

2,*-

OEP 111965 MEMORANDUM FOR:

D. Crutchfield, Assistant Director for Safety Assessment, DL FROM:

L. S. Rubenstein, Assistant Director

.for Core and Plant Systems, DSI

SUBJECT:

REVIEW 0F TOPICAL REPORT WCAP-10125-P, " EXTENDED BURNUP EVALUATION OF WESTINGHOUSE FUEL", JULY 1982 Enclosed are the results of our review of topical report WCAP-10125, " Extended Burnup Evaluation of Westinghouse Fuel." We have concluded, as a result of our review of the report, that Westinghouse methods and safety analyses are valid for operation to the lead rod average burnup target proposed by Westing-house. This conclusion is valid only for Westinghouse Zircaloy-clad fuel.

We did not consider the effects of high burnup on Westinghouse stainless steel clad fuel as part of this review.

This review was performed with the assistance of Battelle Pacific Northwest Laboratory under FIN 2533. This concludes our work on TAC 48689.

The evaluation includes an assessment of the radiological consequences of accidents involving extended burnup fuel by the Accident Evaluation Branch.

Or4;irial slar.ed by

),, & Rubenstein L. S. Rubenstein, Assistant Director for Core and Plant Systems, DSI cc: Millard Wohl H. Bernard Carl Beyer, PNL C. Thomas

Contact:

R. Lobel, CPB:DSI X-29475 DISTRIBUTION CENTRAL FILE CPB:R7Fa L. RUBENSTEIN-h L. PHILLIPS R. LOBEL AEB Reading File d

e, U D. FIEN0 G. Hulman

}

  • SEE PREVIOUS CONCURRENCE

.C

CPB:DSI
CPB:DSI:BC :

B

AD:

AME :RLOBEL:cs

CBERLINGER :
L IN :

ATE : c9/9/85

*9/9/85
9/ks/85
9/11/85 OFFICIAL RECORD COPY ~

[

.