ML20151E200

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Rejecting Util Proposal Re Reactor Protection Sys Protective Circuitry Surveillance Requirements.Proposed Tech Specs for Reactor Protection Sys Protective Circuitry Requested within 60 Days of Ltr Date
ML20151E200
Person / Time
Site: Pilgrim
Issue date: 07/15/1988
From: Mcdonald D
Office of Nuclear Reactor Regulation
To: Bird R
BOSTON EDISON CO.
Shared Package
ML20151E202 List:
References
TAC-62793, NUDOCS 8807250408
Download: ML20151E200 (3)


Text

?.

MCO fg UNITED STATES

[

_g NUCLEAR REGULATORY COMMISSION g

l WASHINGTON, D. C. 20555

\\ ***"/

July 15, 1988 Docket'No.:

50-293 Mr. Ralph G. Bird Senior Vice President - Nuclear Boston' Edison Company Pilgrim Nuclear Power Station RFD#1, Rocky Hill Road Plymouth, Massachusetts 02360

Dear Mr. Bird:

SUBJECT:

REACTOR PROTECTION SYSTEM PROTECTIVE CIRCUITRY SURVEILLANCE REQUIREMENTS

Reference:

TAC Number 62793 In your letter of February 17, 1987, which responded to our letter of September 24, 1980, you conclude that Technical Specification surveillance testin appropriate for your recently modified reactor protection system (RPS) g is not power sources. Rather, you propose to perform surveillance on the RPS power source protective circuits once per operating cycle and that this surveillance be dictated by a procedure external to Technical Specifications. The enclosed Safey Evaluation provides our complete response and conclusion that your proposal is unacceptable.

In addition, please refer to Mr. R. J. Janecek's letter of November 12, 1987 on behalf of the BWR Owners Group and sent to Mr. R. E. Starostecki of the NRC.

The subject of Mr. Janecek's letter was the "BWR Owners Group Technical Specification Screening Criteria Application and Risk Assessment." The staff has reviewed this document and responded by letter to Mr. Janecek on May 9, 1988. Appendix D to the staff's response is titled "Results of the NRC Staff Review - BWR Owners Group's Submittal - Retention and Relocation of Specific Technical Specifications." Specifically, note LCO 3.8.4 on page D-9.,

It is identified as Repor^. Item 277 (this refers to Mr. Janecek's letter of November 12, 1987 - comonly called the "Split Report") and is titled "Power Monitoring of RPS."

Both the staff and the BWR Owners Group agree that this specification once each operating cycle) y a 6 month functional test and a channel calibration (operability demonstrated b is appropriate for such an important component.

In sumary, the staff has concluded that:

1) it is appropriate to incorporate the RPS circuitry into the Technical Specifications, and 2) sufficient justification has not been provided to accept your proposal for deleting the six month channel functional test and leaving only calibration on a once per operating cycle frequency.

(y0\\

9807250400gjo 93 PDR ADOCK PNV k

P

t

_p.

We again request that you provide your proposed Technical Specifications for the RPS protective circuitry within 60 days of receipt of this letter.

Sincerely, Original signed by:

Daniel G. Mcdonald, Senior Project Manager Project Directorate I-3 Division of Reactor Projects I/II

Enclosure:

Safety Evaluation cc: See next page DISTRIBUTION: fDocketTFile, NRC & Local PDRs, PDI_3 r/f, SVarga, BBoger, MRushbrook,'UM600nald, 0GC, EJordan, BGrimes, ACRS (10), RWessman

~

/-)

/

7 s

N SEL
DIR/PDI 0FC :PDI-3
P

-3

__:____.....:...g NAME :M cok :ETro er:mw:

onald

JKno
RWessr an DATE:07/1W88

/

07/{S88
07

/8

07/if /88 i

\\

\\

\\

OFFICIAL (RECORDCOPY 4

t 4

Mr. Ralph G. Bird

' Boston Edison Company Pilgrim Nuclear Power Station cc:

Mr. K. L. Highfill Mr. Ralph G. Bird Station Director Senior Vice President - Nuclear Pilgrim Nuclear Power Station Boston Edison Company RFD #1 Rocky Hill Road Pilgrim Nuclear Power Station l

Plymouth, Massachusetts 02360 RFD#1, Rocky Hill Road l

Plymouth, Massachusetts 02360 Resident Inspector's Office Mr. Richard N. Swanson, Manager U. S. Nuclear Regulatory Connission Nuclear Engineering Department Post Office Box 867 Boston Edison Company Plymouth, Massachusetts 02360 25 Braintree Hill Park Braintree, Massachusetts 02184 Chairman, Board of Selectmen 11 Lincoln Street Ms. Elaine D. Robinson Plymouth, Massachusetts 02360 Nuclear Information Manager Pilgrim Nuclear Power Station Office of the Commissioner RFD #1, Rocky Hill Road Massachusetts Department of Plymouth, Massachusetts 02360 Environmental Quality Engineering One Winter Street Charles V. Barry Boston, Massachusetts 02108 Secretary of Public Safety Executive Office of Public Safety Office of the Attorney General One Ashburton Place 1 Ashburton Place Boston, Massachusetts 02108 20th Floor Boston, Massachusetts 02108 Mr. Robert M. Hallisey, Director Radiation Control Program Massachusetts Department of Public Health 150 Tremont Street, 2nd Floor Boston, Massachusetts 02111 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Mr. James D. Keyes Regulatory Affairs and Programs Group Leader Boston Edison Company 25 Braintree Hill Park I

Braintree, Massachusetts 02184

)

l

_J