Text
JF^">%
untTE.) STATES p.
g NUCLEAR RESULATCRY COMMISSl2N
{
- i REOMNW IV
,[
PA!KWAY CENTRAL PtAZA BulLDING
$'+,*.,e p,
811 RYAN PLAZA ORIVE. SulTE 1000 ARUNOTON, TEXAS 79011 SifS0 Y Sequoyah Fuels Corporation Kerr-McGee Center
~~
ATTN:
J. C. Stauter, Director Nuclear Licensing & Regulation P. O. Box 25861 Oklahoma City, Oklahoma 73125 I
~ -
Gentlemen:
Please find enclosed Amendment No. 07 to your NRC material license.
You should review this amendment carefully and be sure that you understand all conditions.
If you have any questions, you may contact the reviewer who signed your license amendment at 817/860-8100.
Please be advised that you must conduct your program involving radioactive materials in accordance with the conditions of your NRC license, representations made in your license application, and NRC regulations.
In particular, note that you must:
1.
Operate in accordance with NRC regulations 10 CFR Part 19, "Notices, Instructions and Reports to Workers; Inspections," 10 CFR Part 20, "Standards for Protection Against Radiation," and other applicable regulations.
2.
Possess radioactive material only in the quantity and fone indicated in your license.
3.
Use radioactive material only for the purpose (s) indicated in your license.
4.
Notify NRC in writing of any change in mailing address (no fee required if the location of radioactive material remains the same).
5.
Request and obtain appropriate amendments if you plan to change ownership of your organ zation, change locations of radioactive material, or make i
any other changes in your facility or program which are contrary to your license coaditions or representations made in your license application and any supplemental correspondence with NRC.
A license fee may be charged for the amendments if you are not in a fee-exempt category.
8804070330 880316 REG 3 LIC70 SNM-1174 DCD
Sequoyah Fuels Corporati'n o 6.
Submit a complete renewal application with proper fee, or termination request at least 30 days before the expiration date on your license.
You will receive a reminder notice approximately 90 days before the expiration date.
Possession of radioactive material after your license expires is a violation of HRC regulations.
7.
Request termination of your license if you plan to permanently discontinue activities involving radioactive material.
You will be periodically inspected by NRC.
Failure to conduct your program in accordance with NRC regulations, license conditions, and representations made in your license application and supplemental correspondence with NRC will result in enforcement action against you.
This could include issuance of a notice of violation; imposition of a civil penalty; or an order suspending, modifying, or revoking your license as specified in the General Policy and Procedures for NRC Enforcement Action, 10 CFR Part 2, Appendix C.
Since serious consequences to employees and the public can result from failure to comply with NRC requirements, prompt and vigorous enforcement action will be taken when dealing with licensees who do not achieve the necessary meticulous attention to detail and the high standard of compliance which the NRC expects of its licensees.
Thank you for your cooperation.
Sincerely,
.idb R. J. Everett, Chief Nuclear Materials Safety Section
Enclosure:
As stated
- i0 84 -
Amendment No. 07 i.s i uun u s a
w WE OF Es g
U.s. NUCLE AR QEGULAToRY Commission i
gl l-MATERIALS LICENSE f Pursuant to the A'omic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438),
H gl Code of Federal Regulations, Chapter 1, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations f
g heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, [
l source, and special nuclear material des:tnated below; to use such material for the purpose (s) and at the place (s) designated below;to
{
l d: liver or transfer such ma'erial to persons ac'horized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any a
g i
conditions specified below.
I o
I Ucensee In accordance with letter dated l
l August 6, 1985 1
1.
Sequoyah Fuels Corporation
- 3. Ucense number 35-12636-02 is arnended in l
Kerr-McGee Center its entirety to read as follows:
l 2.
P. O. Box 25861 g
Oklahoma City, Oklahoma 73125-
- 4. Expiratien date February 28, 1990 f
[
I g
- 5. Docket or
'e 030-0W47 Reference No.
q.
l'
- 6. Byproduct, source. and/or
- 7. Chemical and/or physical S. Maximum amount that licensee special nuclear material form C 'may possess at any one time
under this license I
N I
A.
'A.
Sealed sources'(Texas A.
Not to exceed l
Nuclear.Model.850233 3.5 millicuries y
G l,or'3M.Madel4P6M).
per source q
tr
-M T /
\\ t: -
I B.
Cesium-137 4;,B. 4ealal-sourcas'f(Technical y B.
Not to exceed 0
I
-Operations 14odel 77302) 165 mi11icuries
~-
I per source l
. f. ;,,
w...,
C.
Cesium-137 c'-' 7 C. 5 Sealed soiirces,(Ame'rsham N C.
Not to exceed g
l N
M Y[.
@epp4 CQ 100 microcuries y
l Q,
@ t J.3 <$! /?
P'"'"""
SeNbdMources(Amariham I
0.
/u D.
D.
Not to exceed s
l
'Q Model C00.701) y 100 microcuries g
per source g
y,,. y, s n
I I
I I
E I
I I
I I
l l
4 l
l 1
l I
l R
I t
E I
l g
,0 i
I r}
kYb L-maemuse*
.wemmmz-tmunrem
'gj NXcrom.U4A u.S. NUCLE AR REGuLAToLY CoMMisSloN GAct or Pacts j' 48'8 Licente numkr
~
SUPPLEMENTARV SHEET 35-12636-02 MATERIALS LICENSE 1
030-05947 q
I l
Amendment No. 07 1
1 1
I l
9.
Authorized use:
1 A.
For use in Texas Nuclear Model 5179 source holders for level measurements.
I g
8.
For use in Technical Operations, Inc. Model 773 calibration kit for q
instrument calibration.
1 I
C.
For use in Amersham Model X.23 source holder for gamma attenuation I
measurements.
~~..
l
, \\ 1 '-
L.
D.
For use in Amersham Hodel X.7 source holder for gamma attenuation y
g measurements.
l CONDITIONS R
' \\
l
.~
I 10.
Licensed material shall be used only at the licensee's facilities in Crescent, l
/
gl The licensee shall comply with the provisions, of Title 10, Ctjapter 1, Code of 11.
gl R
Federal Regulations, Part 19, "Notices,.. Instructions and Reports to Workers; l
Inspections" and Part 20, "Standards,for P_rotection Against Radiation."
lj li 12.
Licensed material shall be used byi or under the supervisionlof, Alvin W. Norwood, Ronald L. Fine, Claude Mc_ Thompson, Mi]11am 4. Rogers, Samuel L. Wilson, and y
,l C /p[-(( Q.??
p.
g Scott C. Munson.
E x s v
i 13.
A.
(1) Each seal'ed, source containing, licensed, material ( other than hydrogen-3, R
with a halfMi/e greater thart 30 days and ini any form other than gas I
shall be test d'Yor leakage and/or contaminatlon at intervals not to t
f exceed 6 months, except sealed sources, contained in Texas Nuclear Model 5179sourceholdersNhallbq,4tesf.edforleakageand/orcontaminationat i
gI intervals not to exceed 1 years. pin the absence of a certificate from Il a transferor indicating that a test has been made within 6 months prior l
I; to the transfer, a sealed source received from another person shall not be put into use until tested.
t l'
II 1
I I!
I;
(!
E'I I'
II I!
E!
$I-ti MtX+MWKi.t~Xif,MitKiiD^KiLiXiD.XiXEEfitHKffM CtMi? W h
g, sac ro,m 3N A W.S. N8 COEUR Re@LWTLel;N L9sOWSSisR)l FAGE 3
or 4
naGEs I;
Lacerne f. umber MATERIALS LICENSE 3,,,,,,,,,7,,,,j,q,mbc1 35'1 6-0 SUPPLEMENTARY SHEET 030-05947 I
I Amendment No. 07 I
I I
i 13.
(continued) l l
(2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source is exempt from such leak tests when the source g
g contains 100 microcuries or less of beta and/or gamma emitting mrterial g
or 10 microcuries or less of alpha emitting material.
1 (3) The periodic leak test required by this condition does not apply to l
sealed sources that are, stored _and not being used.
The sources excepted from this.te,st.,st.all.be tested for leakage prior to any use y
g or transfer to another person unless'-they have been leak tested within g
6 months prior to the date of use or transfer.
4 ij B.
The test shall be capable of detecting the presence of 0.005 microcurie of I
radioactive material on the test sample.
The tes,t sample shall be taken I
from the sealed sou'rce or from the surfaces of ~the device in which the l
sealed sourcefis permanently mounted or stored ~on whith one might expect g
contamination to accumulate.
Records of' leak test results shalt be kept q;
in units of microcuriesiand' maintained lfor inspection by the Comilasion.
1;
~
L.
E C.
If the test ~ reveals the presence:ofio.005'm'icrocurie or more of removable I,
contamination, the licensee shall immediately withdraw.the sealed source k;
from use and shall cause it to be decontaminated'and re h
disposed of in ac'cordarice with-Commission regulations.d: paired or to be A report shall be gj filed within 5 days of the. test with the.U. S. Nuclear Regulatory Commission, E!
Region IV, 611'Ryari Plarale.',Mu'ite4000ZA'rlington C/Jexas 76011, describing ol the equipment'.'involv'ed,'the test re'sditsy,.alid the c6rrective action taken.
l x
y il D.
Tests for leaka#(,j' feifically authorized by thttommission or a g
f by other persons sp q!
State to perform such services.
g'
,.c i
14.
Sealed sources containing licensed material'shall no* be opened.
6i' G.
G i'
d I!
4 ti i
q l
tl 6
il, I
l 4l di I
~
- WM3XXXfM3XXhgrXiir-~Wff#XXhfdKTddfT1hTXhfMf*Wh@
l
g, Nac F.pm 3740 U.S. NUCLE AR REGUL AToRY CoMMisSloN {
ococ d
or 4
Docts l
Lxense number h.-
35-12636 0 MATERIALS LICENSE-
, g a,,,_,94,2 p
l SUPPLEMENTARY SHEET g
030-05947 l
l l
I Amendment No. 07 t
1 I
I 15.
Installation, relocation, removal from service, maintenance, repair, and initial I
radiation survey o' Texas Nuclear devices containing licensed material and l
installation, rep., ament, and disposal of sealed sources containing licensed y
material used in Texas Nuclear devices shall be performed only by the licensee, g
Texas Nuclear, or by other persons specifically authorized by the Commission or l
an Agreement Stat 2 to perform such a rvices.
1 I
16.
The licensee shall conduct a physical inventory every 6 months to account for
[
all sealed sources received and posses, sed under the license.
The records of the g
inventories shall be maintained for.2 years from the date of the inventory for g
inspection by the Commi.ssion','and shall include the quantities and kinds of g
licensed material, location of sealed sources and'the date of the inventory.
4; dj 17.
Except as specifically provided otherwise by this license, the licensee shall i
possess and use licensed material described in Items 6, 7,and 8 of this license I
in accordance with statements, representations, and procedures contained in l
application dated April 26, 198.4, and letters dated'Januar'y '30,1985, and g
August 6, 1985.
The Nuclear Regulatory. Commission's regulations shall govern the g
licensee's statements in applicationi~or letters,'unless the statements are more I
restrictive than the regulati,ons.
I g,
p Ni, ir.
g
^-
U2' #M, ; :'Dj ef.G-[Ec. -
p'
_e j
I
'v ' s I
1; Q '..
,. ~ ty i
.. Qisye., -
v, -
As, 5.
g g
r.7,
y,Q. j >
g.
.v I
- ' n A
q!
I;'
s 1
.d.-
q 3.
e p
e
.s II'l ll 1
4 g
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
{
I!
I; Mb1 Date et 01c85 By Yn -
Nuclear Materials Safety Section l
q; l
qi Region IV 4;
Arlington, Texas 76011 t
dl l
8l l
I; I
(,
l Al l
di i
t lf l
dls'._____.__.._-_.__-__.-___--
. gmTAT&Tm's.:mTsTmTMLT&T&TELT&TATAT&T&mN"&T&TmLTALT.T&5.JN
CIMARRON PLUTONIUM PLANT MATERIAL CONTROL AND ACCOUNTING OF SPECIAL NUCLEAR MATERIAL This material control and accounting plan is to be maintained in compliance with 10 CFR Part 74, Subpart B.
The Standby Operations Manager shall be responsible for developing,
- revising, implementing, and enforcing the measurement and cccountability procedures.
The procedures shall be reviewed and cpproved by appropriate plant and corporate management.
The plutonium content of drums of waste produced in completing the decontamination of the plutonium plant shall be measured and shipped to burial upon accumulation of a
sufficient amount.
Accurate records shall be maintained of the measurements and disposition by drum number.
Each transfer of special nuclear metal of one gram or more shall be reported by completion and distribution of a
Nuclear Material Transaction Report (DOE /NRC Form 741).
A Material Status Report on a DOE /NRC Form 742 shall be compiled as of March 31 ard September 30 of each year and shall be submitted to NRC within 30 days after the end of the period covered by the report.
Any apparent loss of special nuclear material which cannot be resolved by an immediate investigation shall be reported to the NRC Operations Center.
The NRC Operations Center shall be notified within one hour of discovery of any loss or theft or other unlawful diversion of special nuclear material, or any other incident in which an attempt has been made to commit a
theft or unlawful diversion of special nuclear material.
The notification shall be made to the NRC Operations Center via the Emergency Notification System.
If the Emergency Notification System is inoperative, the notifitation shall be made by commercial telepho!>e.
At least oace a year, an internal review of the overall system of special nuclear material control shall be conducted for corporate management and reported to the Standby Operations Manager.
The audit shall cover
- accuracy, completeness, and adherence to measurement and accountability procedures and regulatory requirements.
7 00 g ot. u0 0 3 9 2
-.