5 TABLE HP 10.3-2 (Revised)
BIC ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT CASEOUS TFFLUENTS - SUMMATION OF RELEASES JANUARY 1987 to JUNE 1987 Est Total A.
PISSION AND ACTIVATION CASES **
UNITS ist QUARTER 2nd QUARTER Error %
1.
Total release Ci 8.34E+02 2.20E+03 2.
Average release rate for period uCi/see 1.07E+07 2.80E+02 6.66 3.
Percent of annual ava MPC I
2.80E-02 7.76E-02 B.
IODINES 1.
Total Iodine Ci 4.02E-03 8.13E-03 2.
Average release rate for period uCi/sec 5.17E-04 1.03E-03 5.65 3.
Percent of annual ava MPC 3.13E-05 2.06E-05
~
C.
PARTICULATES 1.
Particulates with half-life >
8 days Ci
,3.ta -04 3.90E-04 2.
Average release rate for period uCi/sec 4.43E-05 4.96E-05 3.
Percent of annual avg MPC I
1.54E-06 2.72E-06 10.8 f
4 Cross alpha radioactivity Ci 4.16E-07 1.10E-06 5.
Cross alpha release rate for period uCi/sec 5.35E_-08 1.4pE-07 D.
TRITIUM **
~
1.
Total release Ci 2.12E+00 2.19E+00 2.
Average release rate for period uCi/sec 2.72E-01 2.79E-01 3.
Percent of annual ava MPC I
1.24E-05 1.27E-05 E.
1.
Beta air dose at site boundary due to Noble Cases (TS 13.1.4.2a) mRads 5.96E-03 1.42E-02 2.
Percent limit 5.96E-02 1.42E-01 3.
Camma air dose at site boundary due to Noble Cases (TS 13.1.4.2a) mRads 9.27E-03 2.29E-02 4.
Percent limit 1.85E-01 4.58E-01 F.
1.
Maximun organ dose to public based based on critical receptors (TS 13.1.4.3a) mRee 8.32E-03 2.0$E-03 2.
Percent _of limit 1.11E-01 2.73E-02 o Note Data is reported for I-131 and I-133 only
- Notet Includes calculated emergency condenser fission gas and tritium releases to atmosphere.
8803010097 000226 PDR ADOCK 05000155 R
PDR IC0288-0025A-HP01
e, TABLE HP 10.3-2 (Revis:d) 0 BIC ROCK POINT SEMIANWUAL RADIOACTIVE EFFLUErr RELEASE REPOJR CASEOUS EFFLUENTS JANUARY 1987 to JUNE 1987 3.
PARTICULATES*
Units let QUARTER 2nd QUARTER Chromium-51 Ci 3.02E-05 4.53E-05 Manganese-54 Ci 2.79E-05 1.53E-05 Cobalt-58 Ci 5.80E-07 None Cobalt-60 Ci 5.03E-05 3.57E-05 Zine-65 Ci 8.02E-06 2.18E-06 Barium-140 Ci 5.74E-05 1.30E-04 Cesium-134 Ci 4.24E-05 1.72E-05 Ces ium-137 Ci 6.49E-05 4.81E-05 Nbbium-95 Ci 4.20E-07 None Cesium-136 C1 2.54E-06 None Mercury-203 Ci 3.70E-07 None Silver-110m Ci 1.05E-05 7.00E-07 Molybdenum-99**
C1 1.23E-05 4.70E-06 Lan t han wn-140 **
Ci 1.78E-04 3.60E-04 Strontium-91**
Ci 1.61E-04 9.49E-04 Sodium-24**
C1 2.85E-05 2.15E-05 Bromine-82**
Ci 4.36E-04 1.74E-03 Strontium-89***
Ci 2.8E-05 4.1 E-05 l
Strontium-90***
Ci 1.7E-06 2.5E-06 i
(
Net unidentified beta ci 1.92E-05 5.16E-05 i
Total Cross Cl 1.16E-03 3.47E-03 Total Tl > 8 days ci 3.44E-04 3.90E-04 o Particulates with half-lives >8 days.
- Particulates with half-lives <8 daysl not reflected in overall isotopic totals.
I
- o Calculated from vendor analysis of monthly stack gas filters.
NOTEt Reported net beta and vendor analysed Sr-89/90 results were input to CASPAR code as Sr-90 to yield conservative dose estimates.
IC0288-002$A-HP01 1
i,-
TABLE HP 10.3-1 7
BIC ROCK POINT SEMI, ANNUAL RADIOACTIVE EFFLUEFT RELEASE REPORT BATCH RELEASES JULY 1987 to DECEMBER 1987 A.
Caseous - Continuous Release B.
LIQUID 3rd Quarter 4th Quarter Number of Releases 3
2 Total Release Time Minutes 7.52E+02 4.14E+02 Maximum Release Time Minutes 2.77E+02 2.28E+02 Average Release Time Minutes 2.51E+02 2.07E+02 Minimum Release Time Minutes 2.05E+02 1.86E+02 i
k l
i i
2 l
\\
l l
l l
IC0288-0025A-HP01 1
l
y 8
TABLE HP 10.3-2 BIC ROCK POINT SEMIANNUtL RADIOACTIVE EFFLUElfr RELEASE REPORT CASEOUS EFFLUENTS - SUMMATION OF RELEASES JULY 1987 to DECEMBER 1987 Est Total A.
FISSION AND ACTIVATION CASES UNITS 3rd QUARTER 4th QUARTER Error Z 1.
Total release f
Ci i
2.99E+03 2.33E+03 2.
Averate release rate for period I
uCi/see1 3.76E+02 2.93E+02 4.91 3.
Percent of annual ava MPC I
i 1.04E-01 8.11E-02 B.
IODINES 1.
Total Iodine Ci 6.79E-03 8.07E-03 2.
Average release rate for period uCi/sec 8.54E-04
- 1. 02 E-0 3 5.51*
3.
Percent of annual ava MPC 2.63E-05 2.68E-05 C.
P ARTI CULATES I
1.
Particulates with half-life >
~
8 days Ci 9.17E-04 7.84F,-04 2.
Averste release rate for period uCi/see 1.15E-04 9.86E-05 3.
Porcent of annual ava MFC 7.46C-06 1.67E-06 10.2 4.
Cross alpha radioactivity Ci 8.30E-07 8.50E-07 5.
Cross alpha release rate for period uCi/see 1.04E-07 1.07E-07
~~
D.
TRITIUM 1.
Total release Ci 1.3E+00 1.3E+00 2.
Average release rate for period uCi/see 1.6E-01 1.6E-01 l
3.
Percent of annual ava MFC 1
7.4E-06 7.4E-06
.E.
1.
Beta air dose at site boundary due to Noble Cases (TS 13.1.4.2a) mRads 1.83E-02 1.42E-02 2.
Percent limit 1.83E-01 1.42E-01 3.
Camma air dose at site boundary due I
to Noble Cases (TS 13.1.4.2a) mRads 3.05E-02 2.33E-02 l
4.
Percent limit 6.10E-01 4.66E-01 l
F.
1.
Maximum organ dose to public based based on critical receptors (TS 13.1.4.3a )
mrem 1.36E-02 5.77E-03 2.
Percent of limit 1.81E-01 7.69E-02
- Notet Data is re-Orted for I-131 and I-133 only t
IC0288-0025A-HP01
TABLF,HP 10.3-2 9
BIC ROCE POINT SFMI ANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT CASEQUS EFFLUENTS JULY 1987 to D,ECEMBER 1987 1.
FISSION CASES Units 3rd QUARTER 4th QUARTER Krypton-85m C1 4.13E+01 3.40E+01 Krypton-87 C1 2.131t+02 1.76E+02 Krypr.on-88 C1 1.28E+02 1.08E+02 Xenon-133 C1 1.50E+01 1.23E+01 Xenon-133m Ci None None t
Xenon-135 C1 2.01E+02 1.68E+02 Xenon-135m Ci 3.65E+02 2.73E+02 Xenon-138 Ci 1.51E+03 1.10E+03 Witrogen-13 Ci 5.13E+02 4.58E+02 Total for Period Ci 2.99E+03 2.33E+03 2.
IODINES Iodine-131 Ci 8.00E-04 7.70E-04 Iodine-132 Ci None None Iodine 133 Ci 5.99E-03 6.30E-03 Iodine-134 Ci None None Iodine-135 Ci None 1.00E-03 Total for Period Cl 6.79E-03 8.07E-03 IC0288-0025A-HP01
1 TABLE HP 10.3-2 10 BIC ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT CASEOUS EFFLUENTS JULY 1987 to DECEMBER 1987 3
PARTICULATES*
Units 3rd QUART'ER 4th QUARTER Chromiusr51 Ci 4.45E-05 1.4 3E-04 Manzanese-54 Ci 9.40E-06 1.15E-05 Cobalt-58 Cl None None Cobalt-60 Ci 2.70E-05 4.20E-05 Zine-65 C1 1.30E-06 1.00E-05 Barium-140 Ci
- 4. 44 E-04 2.36E-04 Cesium-134 Ci 3.55E-05 6.69E-05 Cesium-137 Ci 9.70E-05 1.56E-04 Niobium-95 Ci None 2.87E-07 Silver-110m Cl 1.30E-06 1.25E-05 l
Strontium-91**
Ci 6.60E-03 3.69E-03
(
Lanthanum-140**
C1
- 1. 33 E- 03 7.10E-04 Bromine-82**
Ci 5.43E-03 3.11E-03 l
S od i u m-24 **
Ci None 2.52E-05 Mol ybde nue-99 **
Ci
- 6. 50 E-06 3.14E-05 Westunium-239**
Ci None 1.85E-05 Strontium-89***
Ci 9.6E-05
- 1. 0 E-04
\\
Strontium-90***
Cl 1.1E-06 1.4E-06 Net unidentified beta Ci
- 1. 60 E-04 4.60E-06 Total Ci 9.17 E-04 7.84E-04 i
o Notes Particulates with half-lives >8 days.
- Notel Particulates with half-lives <8 dayst not reflected in overall isotopic totals.
- No t e t Calculated from vendor analysis of monthly stack p.as filteral November and December results based on estimate due to unaval'embility of sample analysis.
Reported net beta and vendor analyzed Sr 89/90 results were input to CASPAR code as Sr-90 to yield conservative dose estimates.
IC02b8-0025A-HP01
a.
TABLE HP 10.3-3 11 BIC ROCK POINT SEMI ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS - SUMMATION OF RELEASES JULY 1987 to DECEMBER 1987 Est Total A.
FISSION AND ACTIVATION PRODUCTS UNITS 3rd QUARTER 4th QUARTER Error %
1.
Total release (not including tritium, nases, alpha)
Ci 1.00E-01 6.53E-03 2.
Average diluted concentration durina period uci/mi 3.89E-09 2.60E-10 4.27 3.
Percent of MPC 4.49E-01 3.74E-03 B.
TRITIUM 1.
Total release Ci 9.52E-02 1.54E-02 2.
Average diluted concentration durina period uCi/mi 3.69E-09 6.18E-10 6.16 3.
Percent of MPC 1.22E-04 2.06E-05 C.
DISSOLVED AND ENTRAINED CASES 1.
Total Release Ci None None 2.
Average diluted concentration durina perled uCi/ml None None None 3.
CROSS ALPHA RADIOACTIVITY (Total Release)
C1 2.28E-06 2.002-07 1.
Average diluted concentration
[
durina period
,uCi/ml 8.84E-14 8.03E-15 E,
VOLUME OF WASTE RELEASED (Prior to Dilution)
Liters 5.11E+04 3.36E+04 F.
VOLUME OF DILUTION WATER USED DURING PERIOD Liters 2.58E+10 2.49E+10 C.
MAXIMUM DOSE COMMITMENT - WHOLEBODY mrem 4.65E-02 7.22E-03 Percent of TS 3.24.4.la limit 3.10E00 4.81E-01 H.
MAXIMUM DOSE COMMITMENT - ORGAN mRee 1.00E-01 !
1.15E-02 Percent of TS 3.24.4.la limit 2.00E00 l
2.30E-01 IC0288-002$A-HP01
b.
TABLE HP 10.3-3 12 BIC ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS JULY 1987 to DECD(BER 1987 1.
NUCLIDES RELEASED Units 3rd QUARTER 4th QUARTER Cesiumm137 Ci 1.27E-02 2.70E-03 Cobalt-58 Ci 7.40E-04 None Manganese-54 Ci 2.79E-02 1.00E-03 Cobalt-60 Ci 2.01E-02 2.10E-03 Cesium-134 Ci 8.80E-04 3.80E-04 Iron-59 Ci 2.28E-03 None Chromium-51 Ci 5.00E-04 None Zine-65 Ci 6.10E-04 None Silver-110m Ci 3.30E-04 None Iodine-131 Ci 2.00E-05 None Strontium-89**
Ci 1.8E-04 1.6E-04 l-Strontium-90**
Ci 2.7E-04 1.9E-04 l
Net Unidentified i
Beta ci 3.39E-02 None Fission & Activation Product Total (Above)
Ci 1.00E-01 6.53E-03 Xenon-133 Ci None None Tri t i um Ci 9.52E-02 1.54E-02 Crand Total Ci 1.95E-01 2.19E-02
- Notel Calculated from vendor analysis of monthly radwaste composite samplest October and December results based on estimate due to unavailability of sample analysis.
Reported net beta and vendor analyzed Sr 89/90 results were input to LADTAP code as Sr-90 to yield conservative dose estimates.
I IC0288-0025A-HP01
2, TABLE HP 10.3-4 I3 BIC ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUElff RELEASE REPORT SOLID RADI0 ACTIVE WASTE JULY 1988 to DECDIBER 1987 Weste Source of Solidification Container Volume Total
- Principal Class Waste Atent Type (Cu.ft.)
Curies Radionuclides A
DAW N/A Strong tight 1010.0 0.5 Co-60, Mn-54, Container-Cr-51, Cs-137, LSA Zn-54 Total Shipped 1010.0 0.5 i
- NOTEt Camma isotopes are measured quantitiest s,11 other isotopes are estimated.
l IC0288-0025A-HP01 l
.