REGISTRY-0F RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE N0:
NR-310-D-101-5 DATE: JUN 121984 PAGE 1 0F 4 l-DEVICE TYPE:
Lightsource Cell Assembly i
J MODELL P/N 12304725 l
l
\\
l DISTRIBUTOR:
General Dynamics Land Systems,.Inc.
t
'P. O. Box 1852 Warren, Michigan 48001 MANUFACTURER:
Optic-Electronic Corp 11477 Pagemill Rd Dallas, Texas l
SEALED SOURCE MODEL DESIGNATION:
Self Powered Lighting Corporation P/N 12274313 not to exceed 7 curies, or Mb-Microteck source P/N 123047259 not to exceed 10 curies, t-ISOTOPE:
MAXIMUM ACTIVITY:
- Hydrogen-3 10 curies l
LEAK TEST FREQUENCY:
Not Required PRINCIPAL USE:
(W) Self luminious Applications i
l CUSTOM DEVICE:
X YES NO For use by the Department of Defense throughout the USA.
9602260207 96022'3 PDR RC l.
SSD PDR
/~N O,
o U
o REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE N0:
NR-310-D-101-S DATE: JUN 121984 PAGE 2 0F 4
-DEVICE TYPE:
Lightsource Cell Assembly DESCRIPTION:
The sealed tritium light is constructed of borosilicate glass capsule that is i
internally coated with a phospher and filled with tritium gas under a pressure of 40 psi.
To provide high resistance to breakage every light is embedded into 0.050 inch silicone and sealed inside a steel cell that is then assembled into the optical collimator or tank muzzle reference system (MRS).
The MRS is then mounted to the tank.
Different style tanks require different optical collimator y
and attachment hardware.
General Dynamics assigns a unique MRS part number to each unique system.
However they all use the same source cell.
LABELING:
Due to location of the source cell labeling of the cell is impractical.
However the complete MRS is labeled in accordance with part 20.203 and contractual require-ments of Department of Defense (D0D).
t Diagram I
l See attachment 1 and 2.
l l
l CONDITIONS OF NORMAL USE:
The muzzle refer sensor system is used by tank operations personnel to determine L
the position of the gun.
l t
[-
f o
9 REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO:
NR-310-0-101-S DATE: g y PAGE 3 0F 4 DEVICE TYPE:
Lightsource Cell Assembly PROTOTYPE TESTING:
j Each source is leak tested, visually inspected for compliance with design specification and brightness.The completed MRS has been tested to military specification'to' determine the unit will operate under temperature'and other environmental or operational conditions which are associated with their use.
EXTERNAL RADIATION LEVELS:
The manufacturer reports no detectable radiation levels on any accessible surface of the MRS_or the Light Cell.
' QUALITY ASSURANCE AND CONTROL:
All components are built to contractual specification.
General Dynamics inspects all incoming parts for compliance to design specifications and functionally i
tested before they are sent'to the D0D.
The D00 will not accept any MRS that does not meet the contractual agreement.
LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
o-
.These light cell assemblies contained in the muzzle reference system shall be distributed only to the specific licensee referenced in this document (The Department of Defense).
o
- Handling, storage, use, transfer and disposal to be determined by the 1
- licensing authority.
l o
- This registration sheet and the information contained within the references f
shall not be changed or transferred without the written consent of the NRC.
t" g
geeM-'imi-y P
-Tg4
e q
-e m
w r
w-
,+meaeer n-we "wi4 w - + - 'a-s 1
..~
=
t
\\
')
O V
o REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE N0:
NR-310-D-101-S DATE: JUN 121984 PAGE 4 0F 4 I
DEVICE TYPE:
Lightsource Cell Assembly SAFETY ANALYSIS
SUMMARY
Based on our review of the information and that data cited below, that the light cell was previously deemed acceptable for licensng purposes, and that modification to the MRS mounting hardware do not effect the integrity of the light cell assembly, we continue to conclude that the device design is accept-able for licensing purposes.
This registration sheet was formulated to incor-(
porate the MRS into the automated registry system.
I
REFERENCES:
The following supporting documents for the light source cell assembly are i
hereby incorporated by reference and are made a part of this registry document:
1 o
General Dynamics letter dated on December 7,1983 and their license number 21-21060-1 with enclosure letter.
ISSUING AGENCY:
USNRC g.( ?
Date:
Reviewer:.
Mas [
er@F y
fa,tb JM. die //
- Date:
Concurrence:
U V
4 l
l.4 Nt:?
?
O A
- t, S
u wD SEALING COMPOUND gg TYPE II COLOR WHITE A
W SPEC MIL-A-46106 4h O
m
-4 LOCKING COMPOUND
$m TYPE I, GRADE N g
+ /+
em 3
SPEC MIL-S-46163 E
N ER m o
=
g Mm g
m z
b CELL-12304726
~
w
~
S o
g a
'BEAMSPLITTER ASSY-12304727 M
i!
I a
5 4
,/'r
~
COTTER P
IN-MS24665 g
!E!
-lOl3 o
I h
CELL ASSY-12304713 s
9 P
n..
E ACKIN -M G
i g
S9021-027 A
g HOUSING-123 s-S 04712
\\
3
' Wq WIN 00W-122858 B(
t r,
67
\\
P L ACKING-M
- )
S e;
RETICLES9021-030
> j-ag i
SING m$ ik HOU P
ACKING-MS9021 ASSY-123 y
x CELL ASSY-1230-025 20 hjg.
047 4725
- jd m$
j,!
0 e
i
/
l t=
4 E
a Ea A
T S
/
COTTER PIN-MS24665-lOl3 buh 0 i'l [ CELL ASSY-12304713 l
s,5-- ~~b w n 8
( r PACKING-MS9021-027 y
J' 8
gg s
g 8
5 HOUSING-12304712 E[
2f' i
as t
~
i eE a
s E
I E
M ME 3
a
-@d[ WINDOW-12285867 q
g 52 2"
z 1 w glb.,
=
c
/l Y
/
V3 o
PACKING-MS9021-030 m
c>
m ynp L. RETICLE HOUSING ASSY-12304720 c.,
o aum G
PACKING-MS9021-025 0
CELL ASSY-12304725
i t
1.5 I
w a
l o
=
T S
w w
SEALING COMPOUND gg
'i TYPE H COLOR WHITE a
i SPEC MIL-A-46lO6 4h; o
rn -
[
LOCKING COMPOUND
$5 g
TYPE E, GRADE N 3
B SPEC MIL-S-46163
'm- /
+
e Fn 5
N Si? w S
o m
a i
o z
. c:
m a=
s
' j"-
ta 5
g 2
3 bCELL-12304726
~
i o
o a
2 BEAMSPLITTER ASSY-12304727
?
M i
9 m
m s
i r
I-
.