D Q'
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVAlllATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO: NR-310-D-101-S DATE:
PAGE: 1 of 4 SEP 1 9 1990 DEVICE. TYPE:
Lightsource Cell Assembly i
MODEL:
P/N 12304725 l
i DISTRIBUTOR:
O General Dynamics Land Systems, Inc.
<% P. O. Box 1852 D Warren, Michigan 48001 MANUFACTURER: $ 11477 Pagemill Road
' Optic-Electronic Corp 0 Dallas, Texas SEALED SOURCE MODEL DESIGNATION:
Self-Powered Lighting Corporation P/N 12274313 not to exceed 7 curies, Mb-Microteck source P/N 12304725 not to exceed 10 curies, or SRB Technologies Inc. P/N 12304725 not to exceed 10 curies ISOTOPE:
MAXIMUM ACTIVITY:
Hydrogen-3 10 curies LEAK TEST FRE0VENCY:
Not Required PRINCIPAL USE:
(W) Self Luminous Applications CUSTOM SOURCE:
X YES NO For use by the Department of Defense throughout the USA 9602260200 960223 PDR RC
(
SSD PDR
O O
i I
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION'0F DEVICE (AMENDED IN ITS ENTIRETY)
NO: NR-310-0-101-S DATE:
SEP 1 8 1990 PAGE: 2 of 4 l
DEVICE TfPE:
Lightsource Cell Assembly DESCRIPTION:
The sealed tritium light is constructed of borosilicate glass capsule that is internally coated with a phosphor and filled with tritium gas under a pressure of 40 psi. To provide high resistance to breakage every light is embedded into 0.050 inch silicone and sealed inside a steel cell that is then arvembled into the optical collimator or tank muzzle reference systems (MRS). The firs is then mounted to the tank. Different style tanks require different optical collimator and attachment hardware. General Dynamics assigns a unique MRS part number to each unique system. However, they all use the same source cell.
LABELING:
Due to location of the source cell labeling of the cell is impractical.
However, the complete MRS is labeled in accordance with Part 20.203 and contractual requirements of Department of Defense (D00).
DIAGRAM:
See Attachments 1.
CONDITIONS OF NORMAL USE:
The muzzle reference sensor system is used by military tank operations personnel to determine the position of the gun.
\\.
O O
REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO: NR-310-D-101-S DATE:
SEPIeleg)
PAGE: 3 of 4 DEVICE. TYPE:
Lightsource Cell Assembly
, PROTOTYPE TESTING:
Each source is leak tested, visually inspected for compliance with design specification and brightness. The completed MRS has been tested to military specification to determine the unit will operate under temperature and other environmental or operational conditions which are associated with their use.
e EXTERNAL RADIATION LEVELS:
The manufacturer reports no detectable radiation levels on any accessible surface of the MRS or the light cell.
QUALITY ASSURANCE AND CONTROL:
All components are built to contractual specification. General Dynamics inspects all incoming parts for compliance to design specifications and functionally tested before they are sent to D0D. The 000 will not accept any MRS that'does not meet the contractual agreement.
1 LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
o The light cell assemblies contained the muzzle reference system shall be distributed only to the specific licensee referenced in this docum 1t (000).
o Handling, storage, use,. transfer and disposal to be determined by the licensing authority, o
This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.
)
9
O O
REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO: NR-310-D-101-S DATE:
PAGE: 4 of 4 SEP I e g DEVICE TYPE:
Lightsource Cell Assembly SAFETY ANALYSIS.
SUMMARY
Based on our review of the information and data cited below, that the light cell was previously deemed acceptable for licensing purposes, and that modification to the MRS mounting hardware do not effect the integrity of the light cell assembly, we continue to conclude that the device design is acceptable for licensing purposes. This registration sheet was formulated to incorporate the MRS into the automated registry system.
REFERENCES:
The following supporting documents for the light source cell assembly are hereby incorporated by reference and are made a part of this registry document:
o General Dynamics letters dated December 7,1982, and December 8,1989, and their License No. 21-21060-01 with enclosures thereto.
ISSUING AGENCY:
U. S. NUCLEAR REGULATORY COMMISSION Date I 9 I990 Reviewer
'O
/
Date SEP Concurrence d'ww$ ^^^ FM l
f 9 tog 1
O O
REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY) 4 i
NO: NR-310-D-101-S DATE:
ATTACHMENT 1 SEP t9; i
l SEALING COMPOUND TYPE D COLOR WHITE SPEC MIL-A-46106 LOCKING COMPOUND TYPE H. GRADE N SPEC MIL-S-46163 s0
)
-+
2 M
s
\\
w,,,
/_
'-CELL-12304726
~
BEAMSP TTER ASSY-12304727
- -