-. O l 's (Boston 'Rdison Company l JUNE 1997 l

INSERVICEINSPECTION

SUMMARY

REPORT FOR REFUEL OUTAGE 11 AT PILGRIM NUCLEAR POWER STATION l

l l

/

Prepared by Date r-1/-97 Reviewed by / -

W Date 5,b'?,[9')

Approved by dd- Date 6/3/97 9706270142 970625 '

DR ADOCK 050002 3

l Table of Contents 1.0 Executive Summary 1.1 Tables  !

Table 1 ISI Examinations Performed On-Line Prior to RFO 11.

Table 2 ISI Examinations Performed During RFO 11.

Table 3 RFO 11 Non-Conformance Reports Table 4 Preservice Visual Examinations Performed During 1997.

Table 5 Preservice Visual Examinations Performed During 1996.

Table 6 Preservice Visual Examinations Performed During 1995.

Table 7 VT-2 Visual Examinations Performed During 1997 System Pressure Tests. I Table 8 VT-2 Visual Examinations Performed During 1996 l System Pressure Tests. l Table 9 VT-2 Visual Examinations Performed During 1995 System Pressure Tests.

2.0 NIS-1 and NIS-2 Code Reports for ASME XI Repairs and Replacements.

J J

d 4

4 4

4 t

4

! 1 SECTION 1.0 EXECUTIVE

SUMMARY

I i

f 1

'd.

-i

)

.'t y

e b

5 i

4 i

4 a

f f

4 4

i 4

4 4

4 n

d

. ~ - - . . . _ . - - - . - . . - _ _ - - - . - . _ . - - - . - . -

PILGRIM NUCLEAR PG%'.R STATION l 1997 REFUEL OUTAGE 11 INSERVICE INSPECTION

SUMMARY

REPORT 1.0 EXECUTIVE

SUMMARY

This report documents the inservice inspection (ISI), preservice inspection (PSI), and augmented examinations performed at Pilgrim NJclear Power Station (PNPS) for the period from the end of Refueling i Outage 10 to the end of Refueling Outage 11. The examinations performed are included in the first period of the Third Ten Year Inspection Interval of the PNPS ISI Prograrn.

Types of examinations performed were-

. ASME XI inservice and preservice visual, surface and volumetric examinations.

. Ultrasonic (UT) examinations for intergranular stress corrosion cracking (IGSCC) per Generic Letter 88-01.

. UT examinations of Salt Service Water piping per Generic Letter 82-13 and BECo Specification M-591.

. UT examinations of high energy piping for flow assisted corrosion per Generic Letter 89-08 and BECo Specification M-577.

. Invessel examinations.

l

. Visual and ultrasonic examinations of the core shroud modification.

. Visual examinations of the drywell annulus air gap drain lines.

. UT and visual examinations of RPV internal core snray piping and spargers.

. Visual examinations for leakage of Class 1,2 and 3 components.

Examination Details:

Examinations were conducted in accordance with ASME Section XI 1989 j Edition and BECo letters to NRC, NOs. 92.048,96.091,96.105,97.003, j 97.010 and NRC letter to BECo dated February 10,1997.

General Electric Company was the examination vendor for examinations 1

l

)

. l l .

l performed during the refueling outage and on-line RHR heat exchanger UT examinations while BECo persor.nel performed the on-line examinations prior to RFO 11.

Regarding BECo letter 92.048 " Revised Inspection Plan for Drywell Annulus Air Gap Drain Lines at PNPS": l The 4" annulus air gap drains were examined after flood up of the l refueling cavity and prior to drain down of the cavity. No leakage was found.

Regarding BECo letter 96.091 " Pilgrim Station 1996 On-Line and Refueling Ontage 11 Inservice inspection (ISI) Plan" as modified by BECo letters 96.105, 97.003, 97.010 and NRC letter dated February 10,1997:

All examinations were completed with the following additional information:

. Ultraconic examination of core spray piping internal to the reactor vessel fcund 6 flaws which were separately reported to the NRC by DECO letter 97.033.

. Visual examinations were performed in the reactor pressure vessel of all jet pumps riser-to-elbow and elbow-to-thermal sleeve welds per General Electric SIL 605; no flaws were found.

. Visual examinations of one half of all jet pump assemblies included the riser brace welds, beam assembly, swing Cate and latch pin, set screws, wedges and slip joints. Due to nonconformance reports (NCR 97-105 and NCR 97-117) for swing gate position, the scope of the examinations was expanded to include all swing gate assemblies.

. Ultrasonic examinations of a 25% sample of the equivalent length l of all core shroud vertical welds (approximately 134 inches) were performed as outlined in BECo letter 96.091 with no reportable l indications datected. Visual examinations performed on components of the core shroud modification revealed no indications. Inspected components included one complete tie rod l assembly, the adjacent gusset plate welds and core plate wedge assemblies, and accessible ring segment welds. Tie rod preload was verified by visual examination of one lower pin assembly for

the presence of a gapped condition. The results of the visual i examination were satisfactory as the tie rod pin was found to be in
intimate contact with the gusset plate.

t

. The steam dryer leveling screws were found to have cracked tack

- welds in two locations (NCR 97-124).

. Two brackets. welded to the vessel interior wall and not previously identified on plant drawings (later identified as abandoned reactor start-up vibration instrumentation brackets) were examined to code requirements.

j . UT thickness measurements were mnde on 54 components for flow assisted corrosion in accordance with Generic Letter 89-08. This -

included a scope expansion of 5 components due to a thin wall j finding. Refer to NCR 97-106 and NCR 97-108.

l

. A rejectable flaw in the Class 2 RHR piping support lug GB l 117HLi(4) documented in NCR 97-64 and NCR 97-134 caused a L scope expansion of 7 similar components. No additional flaws were identified.

. -Class 2 RCIC Weld HD-13-1-3D was substituted for previously scheduled HB-10-F110 due to inaccessibility for ultrasonics.

. Class 2 RCIC Weld HD-13-1-3D was substituted for previously scheduled HD-13-F41 due to inaccessibility. 1

.- UT examinations were performed on-line on 19 Salt Service Water spools for wall thickness in accordance with Specification M-591 and Generic Letter 89-13. One nonconformance report was written which was unrelated to service conditions.

. A total of 13 nonconformance reports were written on ISI activities.

Six were in regard to core spray piping internal to the vessel, two l were regarding flow assisted corrosion, two were regarding un-lateched jet pump swing gates and one for cracked steam dryer leveling screw tack welds.

Regarding visual examinations for. leakage for Class 2 and 3 pressure testing:

The majority of the Class 2 and 3 systems have been leak checked including the RHRIFPC Inter-tie piping described in BECo letter 96.054.

I 1

1 Tcbla 1 ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO 11 by Boston Edison Company COMPONENT.  ? DESCRIPTION- CATEGORY SYSTEM' ' ISOMETRIC

EXAM-  : DATA

]

SHEETS l 10-VB-100129A VALVE BOLTING B-G-2 RHR 1S11-10-1 VT-1 96-V 205 10-VB-1001-290 VALVE BOLTING B-G-2 RHR 1S1110-1 VT-1 96-V-130 i 97-V-015 l

. 1 11 VB-110116 VALVE BOLTING B-G-2 SBLC 1S1-1-11-1 VT-1 97 V-018 96-V-129 i CATEGORY 10-E207A-1 SHELL TO FLANGE C-A RHR ISI-E207A AUTO UT 96-E-169 96-E-168 i

96-E-167 l

' 96-E-166 96-E-170 I

10-E207A 3 SHELL TO FLANGE C-A RHR ISI-E207A AUTO UT 96-E-172 4

96-E-173 96-E 174 96-E 175 96-E-171 10-E207A-4 HEAD TO FLANGE C-A RHR ISI-E207A AUTO UT 96-E-177 96-E-179 96-E-176 96-E-180 96 5-178 10-E207A-5 HEAD CIRC WELD C-A RHR ISI-E207A AUTO UT 96-E-182  ;

96-E-181 96-E-183 96-E-184 96-E-185 page 1 of 7

Tcbla 1 1

ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO 11 l by Boston Edison Company COMPONENT DESCRIPTION ' CATEGORY' SYSTEM' ISOMETRIC EXAM - ' DATA SHEETS CATEGORY 10-E207A-N3-1 NOZZLE TO SHELL C-B RHR ISI-E207A VT-2 VT-10-97003 WELD WITH i REINFORCING l PLATE 10-E207A N4-1 C-B RHR ISI-E207A VT-2 VT-10-97003 CATEGORY GB-14-8HLi(4) SUPPORT LUGS C-C CS ISI-l-14-2A MT 97 M-010 CATEGORY GB-14-F84 PIPE TO VALVE C-F-1 CS ISl 1-14 2A PT UT 96 P-138 96-E-132 96-E-134 '

96-E-136 GB-14-F85 VALVE TO PIPE C-F-1 CS ISI-l 14-2A PT UT 96-E-136 96-E 134 96-E-132 96-P 139 CATEGORY 3-ESD-16 ELBOW TO PIPE C-F-2 CRD ISI-l-3-1 MT UT 96-E-078 96-M-074 96-E-076 3-ESD-24 ELBOW TO PIPE C-F 2 CRD ISI-l-3-1 MT UT 96-M-069 96-E-071

~

96-C-070 96-C-072 96-E-073 GB 14-4-3F PIPE TO ELBOW C-F-2 CS ISI-l-14-2A MT UT 96-E-024

96-M-021 page 2 0f 7

Tcbla 1 ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO 11 '

by Boston Edison Company l

COMPONENT . DESCRIPTION ' ' CATEGORY. SYSTEM ISOMETRIC EXAM -DATA SHEETS 96-C-023 l

96-E-027 96-C-026 )

GB-14-F39 PIPE TO VALVE C-F-2 CS ISI I-14-2B MT UT 96-M-022 l

96-E-025 96-E-028 96-C-026 EB-23 3-1B RED. ELBOW TO C-F-2 HPCI 1S1-1-23-5 MT UT 96-E-087 PIPE 96-E-090 96-U-204 96-E 195 96-M-203 96-M-080 EB-23-F35 PUMP TO RED. C-F 2 HPCI 1S1-1 23-5 MT UT 96-E-082 ELBOW l 96-E-084 96-E-086 )

96-M-079 l 96-E-089 HD-13-1-3D PIPE TO TEE C-F-2 RCIC 1S11-13-2 MT UT 96-M-029 l

96-C-034 96-E-035 96-E-032 96-C-031 l GB !O-17-3A-l TEE TO PIPE C-F-2 RHR ISI-l 10-3A MT UT 96-C-061

\

i l 96-E-067 l l

page 3 of 7

1 TEbla 1 ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO 11 by Boston Edison Company COMPONENT. ' DESCRIPTION CATEGORY'. SYSTEM- ISOMETRIC . EXAM DATA

. SHEETS 96-M-059 96-C-065 96-E-063 GB-10-18-4B PIPE TO C-F-2 RHR ISI-l 10-3A MT UT 96-M-016 WELDOLET 96-C-017 l

l 96-E-020 96-C-019 96-E-018 HB-10-1-10B ELBOW TO PIPE C-F-2 RHR ISI-1-101B MT UT 96-E-044 -

l 96-M-037 96-C-039 96-U-012 96-C-042 96-M-038 96-M-013 96-E-041 HB-10-3-1E TEE TO REDUCER C-F-2 RHR ISI-1-10-1B MT UT 96-C-046 96-E-049' 96-M-045 I

96-E-047 96 C-048 HB-10-3-1F REDUCER TO C-F-2 RHR ISI-I-10-1B MT UT 96-E-066 ELBOW 96-E-062 96-C-061

(-

l page 4 of 7

Tsbla 1 ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO 11 by Boston Edison Company COMPONENTf " DESCRIPTION CATEGORY SYSTEM ~ ISOMETRIC . EXAM DATA SHEETS 96-M-058 96-C-065 i l

HB-10-3-2F TEE TO PIPE C-F-2 RHR ISI-l 10-2A MT UT 96-E-190 96-E-189 96-C-061 96-M-188 i 96-C-065 HB-10-F79 VALVE TO ELBOW C-F-2 RHR 1S1-1-10-1C MT UT 96-M-030 96-C-031 96-E-033 1 96-E-036 HB 10-F92 PlPE TO ELBOW C-F-2 RHR ISI-l-10-1 B MT UT 96-E-043 96-U-012 96-M-038 96-M-037 96-C-039 96-E-040 97-M-013 ,

96-C-042 CATEGORY HE-30-10PS STANCHION D-B RBCCW ISl-1-30-1SH2 VT-3 VT-30-96008 HE-30-11PS STANCHION D-B RBCCW ISI-I-30-1SH1 VT-3 VT-30-96004 HE-30-121PS STANCHION D-B RBCCW ISI-I-30-1SH1 VT-3 VT-30-96006 HE-30-437PS STANCHION D-B RBCCW ISI-l 30-1SH1 VT-3 VT-30-96007 HE-30-52PS STANCHION D-B RBCCW ISI-1-30-1 SH2 VT-3 VT-30-96014 page 5 of 7

~ . . _ . . _ . _ _ . _ . _ _ _ _ _ _ _ _ _ _.

Tcbla 1 ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO 11 l by Boston Edison Company

. ISOMETRIC EXAM

' COMPONENT DESCRIPTION . CATEGORY:' SYSTEM ~ DATA SHEETS HE-30 66PS STANCHION D-B RBCCW ISI l 30-1SH1 VT-3 VT-30-96010 HE-30-67PS STANCHION D-B RBCCW ISI-l-30-1SH1 VT-3 VT-30-96011  ;

l HE-30-68PS STANCHION DB RBCCW ISI-l-301SH1 VT-3 VT-30-96012 HE-30-69PS STANCHION D-B RBCCW ISl-1-30-1SH1 VT-3 VT-30-96017 i

HE-30-99PS STANCHION D-B RBCCW ISI-l-30-1SH2 VT-3 VT-30-96013 l l

CATEGORY H-14-1-10 RIGID HANGER F-A CS 1S1-1-14-2B VT-3 VT-14-96002 d

H-14-14SH RIGID HANGER F-A CS ISI-l 14-2A VT4 VT-14-96001 l

! H-231-11 SPRING HANGER F-A HPCI ISI-1-23-2 VT-3 VT-23-96001 H-23-1-16S LATERAL F-A HPCI ISI-l-23-2 VT-3 VT-23-96002 j RESTRAINT j H-23-1 8 SPRING HANGER F-/ HPCI ISI-l 23-2 VT-3 VT-23-96003 4

H 30-1-11SA ANCHOR F-A RBCCW ISI 130-1SH1 VT 3 VT-30-96003

}

I H-301-437 RIGID HANGER F-A RBCCW ISl 1-30-1SH1 VT-3 VT-30 96005 RBCCW VT-3 VT-30 96009 H-30167 RIGID HANGER F-A ISI-l-30-2SH1 H-30 ANCHOR F-A RBCCW ISl-130-2SH1 VT-3 VT-30-96016 69SA/350 H 30-199 RIGID HANGER F-A RBCCW ISI-130-2SH2 VT-3 VT-30 96015 H-13-1-30 RIGID SUPPORT F-A RCIC 1S1-1-13-3 VT-3 VT-13 96002 i

1 H-13-1-32 SPRING HANGER FA RCIC 1S1113-3 VT-3 VT-13-96003 1

H-10-1 101S RIGID HANGER F-A RHR ISt-I VT-3 VT-10-96009 SBSH2 H-10-1-102S LATERAL F-A RHR ISf-I 10- VT-3 VT-10-96010 RESTRAINT 5BSH2 H-10-1-160 RIGID HANGER F-A RHR ISI l VT 3 VT-10 96006 SBSH2 H-10-1-17SS RIGID HANGER F-A RHR ISI-l-10-1C VT-3 VT 10-96004 H-10-1 180 RIGID HANGER F-A RHR ISI-l VT-3 VT-10-96003 '

4 ASH 2 page 6 of 7

Tabla 1 ISI EXAMINATIONS PERFORMED ON-LINE PRIOR TO RFO 11 by Boston Edison Company COMPONENT DESCRIPTION CATEGORY ~ SYSTEM- ISOMETRIC EXAM DATA SHEETS H-10-1-182 SPRING HANGER F-A RHR 1S1-1 10-1C VT-3 VT-10 96005 H-10-1-4SR LATERAL F-A RHR ISI-I-10-3A VT-3 VT 10-96002 RESTRAINT H 10-1-76 RIGID HANGER F-A RHR ISI-l 10- VT-3 VT-10-96008 SBSH1 l H 10-1-81 RIGID HANGER F-A RHR 1S1-110- VT-3 VT 10-96007 f 4BSH1 l H-10-1-E207A HX SUPPORT F-A RHR ISI-E207A VT-3 VT-10-96001

\

.e page 7 of 7

Tcbla2 ISI EXAMINATIONS PERFORMED DURING RFO 11 by General Electric COMPONENT 2 ' DESCRIPTION _ CATEGORY- -SYSTEM ~ ISOMETRIC EXAM RPV-HF-Od20 ~ ~ HEAD TO FLANGE ' B-A RPV 1S1-1-54-2 MT UT RPV-SF-0-120 SHELL TO FLANGE B-A RPV 1S1-1-54-1 UT RPV-TH-M1 MERID HEAD WELD 0 B-A RPV 1S1-1-54 2 UT RPV-TH-M2 MERID HEAD WELD 45 B-A RPV 1S1-1-54-2 UT i l

RPV-TH-M3 MERID HEAD WELD 90 B-A RPV 1S1-1-54-2 UT CATEGORY RPV N3A-NIR NOZZLE INNER RADIUS B-D RPV 1S1-1-54-1 UT l

RPV-N3A-NV NOZZLE TO VESSEL B-D RPV 1S1-1 54-1 UT RPV-N3B-NIR NOZZLE INNER RADIUS B-D RPV 131-1-54-1 UT RPV-N38-NV NOZZLE TO VESSEL B-D RPV ISt-i-54-1 UT l

RPV-N3C-NIR NOZZLE INNER RADIUS B-D RPV 1S1-1 54-1 UT l RPV N3C-NV NOZZLE TO VESSEL B-D RPV 1S1-1 54-1 UT l RPV-N3D-NIR NOZZLE INNER RADIUS B-D RPV 1S11-54-1 UT NOZZLE TO VESSEL B-D RPV 1S1-1-54-1 UT i RPV-N3D-NV RPV-N6A NIR NOZZLE INNER RADIUS B-D RPV 1S1154-1 UT l

RPV-N6A-NV NOZZLE TO VESSEL B-D RPV 1S1-1-54 1 UT CATEGORY 14-A-10A VALVE TO PIPE B-F CS 1S1-114-1 PT UT l

1 A-1 NOZZLE TO SAFE END B-F RPV ISl-1-1-SH1 MT UT 1 B-1 NOZZLE TO SAFE END B-F RPV ISI-l-1-1SH1 MT UT 1-C-1 . NOZZLE TO SAFE END B-F RPV ISl-1-1-1SH1 MT UT 1-D-1 NOZZLE TO SAFE END B-F RPV ISI-l-1-1SH1 MT UT 14-A-1 SAFE END TO NOZZLE B-F RPV 1S1-1-14-1 PT UT 2R-N2G-1 SAFE END TO NOZZLE B-F RPV ISI-i-2R-B PT UT 2R-N2H-1 SAFE END TO NOZZLE B-F RPV ISI-l 2R-B PT UT 2R-N2K-1 SAFE END TO NOZZLE B-F RPV ISI-2R-B PT UT page1 of5

.-. - .. = - --. . _ .

. Tcbla 2 ISI EXAMINATIONS PERFORMED DURING RFO 11 by General Electric l

DESCRIPTION -CATEGORY SYSTEM ISOMETRIC EXAM.  !

, ' COMPONENT.

R.,. . . .

! RPV-N14-1 SAFE END TO NOZZLE , B-F .RPV 1S1-1-11-1 PT

]

RPV-N98-1 NOZZLE TO CAFE END B-F RPV 1S1-l.54 4 PT UT l CATEGORY RPV-CB-1-18 CLOSURE BUSHINGS B-G-1 RPV 1S1-1 54-2 VT-1 l l

RPV-CHN-1-18 CLOSURE HEAD NUTS B-G-1 RPV 1S1-1-54-2 MT RPV-CS-1-18 CLOSURE STUDS B-G-1 RPV 1S11-54-2 UT I l

RPV-CW-1-18 CLOSURE WASHERS B-G-1 RPV 1S1-1-54-2 VT-1 RPV-FT-1-18 THREADS IN FLANGE B-G-1 RPV 1S1-1-54-2 UT CATEGORY 6-VB-57A VALVE BOLTING B-G-2 FW 1S1-1-6-1 VT-1 l

6-VB-578 VALVE BOLTING B-G-2 FW ISI-t-6-1 VT-1 23-VB-2301-4 VALVE BOLTING B-G-2 HPCI ISI-l 23-1 VT-1 1-VB-203-1 A VALVE BOLTlNG <2' B-G-2 MS ISI l 1-1SH2 VT-1 l 1 VB-203-1B VALVE BOLTING <2' B-G 2 MS ISI-l-1-1 SH2 VT-1 1-VB-203-1 C VALVE BOLTING <2' B G-2 MS ISI 1-1-1SH2 VT-1 l 1 VB-203-1D VALVE BOLTING <2' 0-G-2 MS ISI 1 1-1SH2 VT-1 1 VB-203-2A VALVE BOLTING <2' U-G-2 MS ISI l.1-1SH2 VT-1 1-VB 203-2B VALVE BOLTING <2' B-G-2 MS ISI-l.1 1SH2 VT-1 2-VB-202-4A VALVE BOLTING B-G-2 RECIRC ISI-l-2R-A VT-1 RPV-FB-N7A FLANGE BOLTING B-G-2 RPV 1S11-54-4 VT-1 RPV-FB-N7B FLANGE BOLTING B-G-2 RPV 1S1-1-54-4 VT-1 RPV FB-N8 FLANGE BOLTING B-G-2 RPV 1S11-54-4 VT-1 12-VB-1201-2 VALVE BOLTING B-G-2 RWCU ISl-1 12-1 SH1 VT-1 CATEGORY RPV-SBW-0 RPV STABILIZER WELD B-H RPV 1S1-1-54 1 MT RPV-SBW 180 RPV STABILIZER WELD B-H RPV 1S1-1-54-1 MT page 2 of 5

i .

Tcbis 2 ISI EXAMINATIONS PERFORMED DURING RFO 11 by General Electric

COMPONENT- , L DESCRIPTION :  :. CATEGORY' SYSTEM IFOMETRIC ' EXAM.

~

i RPV-SBW-270 ' RPO STABluZhR WELD ' 'B-H RPV' 1S1-1-54-1 MT

RPV-SBW-90 RPV STABILIZER WELD B-H RPV 1S1-1-54-1 M~i'

, CATEGORY 14-A 17 PIPE TO PENETRATION B-J CS 1S1-1-14-1 PT UT I

14-A 18 PIPE TO PIPE B-J CS 1S1-1-14-1 PT UT 14-B-17 PIPE TO PENETRATION B-J CS ISl-1-14-1 PT UT 14-B-18 ELBOW TO PIPE B-J CS ISI-l-14-1 PT UT j 14-B-19 PIPE TO ELBOW B-J CS 1S1-1-14-1 PT UT 14-B-20 PIPE TO PIPE B-J CS ISl-1-14-1 PT UT 6-B-7 PIPE TO VALVE B-J FW ISI-l-6-1 MTUT 6-N4B-8 ELBOW TO PIPE B-J FW ISI-l-61 MT UT 6-N4C-9 ELBOW TO PIPE B-J FW ISI-l-6-1 MT UT 23-0-10 VALVE TO ELBOW B-J HPCI 1S1-1 23-1 MT UT I 23-O 9 PlPE TO VALVE B-J HPCI 1S1-1-23 1 MT UT 1-A-14 VALVE TO PIPE B-J MS ISI-1-1-1SH2 MT UT 1-SD-8R VALVE TO PIPE B-J MS ISI-l-1-1SH2 MT 13-0-3 PIPE TO ELBOW B-J RCIC 1S1-1-13-1 MT 13-O-4 ELBOW TO PIPE B-J RCIC 1S1-1-13 1 MT -

10R-IB-12 PENETRATION TO ELBOW B-J RHR 1S1-1-10-1 PT UT 12-O-29R ELBOW TO PIPE B-J RWCU ISI-l 12-1SH1 PT UT 12-0-30R PIPE TO ELBOW B-J RWCU ISI-1-12-1SH1 PT UT 12-0-31 R ELBOW TO PlPE B-J RWCU ISI-l.12-1SH1 PT UT 12R-BC-6 PIPE TO ELBOW B-J RWCU ISI-I-12-1SH2 PT B-11-304 ELBOW TO PlPE B-J SBLC 1S1-1 11-1 PT B-11-305 PIPE TO ELBOW B-J SBLC 1S11-11-1 PT page 3 of 5

l l .

. Tcbla 2 1

ISI EXAMINATIONS PERFORMED DURING RFO 11 l by General Electric COMPONENTJ DESCRIPTION CATEGORY SYSTEM. ISOMETRIC EXAM CATEGORY l

RPV INTERIOR VESSEL INTERIOR B-N-1 RPV N/A VT 3 CATEGORY GB-14-2HLi(4) SUPPORT LUGS C-C CS 1S1-1-14-28 MT l EB-23-13HLi(4) SUPPORT LUGS C-C HPCI 1S1-1-23-2 MT" l

MT" EB-23-59HLi(4) SUPPORT LUGS C-C HPCI 1S1-1 23-2 EB-23-62HLi(4) SUPPORT LUGS C-C HPCI 1S1-1-23-2 MT" HB-23-75HLi(8) SUPPORT LUGS C-C HPCI 1S1-1-23-3 MT" HE 26- SUPPORT LUGS C-C HPCI ISI-l-23-4 MT" '

175HLi(1)

HB-13-F HLi(2) HANGER LUGS C-C HPCI 1S1-1-23-3 MT" 10-E2078-S1 HX SUPPORT LUGS C-C RHR ISI-E207B MT l 10-E2078-S2 HX SUPPORT LUGS C-C RHR ISI E207B MT 10-E207B-S3 HX SUPPORT LUGS C-C RHR ISI-E207B MT 10-E2078-S4 HX SUPPORT LUGS C-C RHR ISI-E2078 MT i 1

l GB SUPPORT LUGS C-C RHR ISI-l 10-3A MT l l

117HLi(4)

HL SUPPORT LUGS C-C RHR ISI l-10-4 ASH 1 MT" l 200HLi(4)

CATEGORY HL-10-4-28 ELBOW TO PIPE C-F-2 RHR ISI l-10-2A MT UT HL-10-F202 NOZZLE TO PIPE C-F-2 RHR ISI-l-10-2A MT UT -

" Expanded ecope exams SLT RHR-13 PRESSURE BOUNDARY C-H RHR ISi I-10-1C VT-2 CATEGORY H-6-1-102 SPRING HANGER F-A FW ISI-l-61 VT-3 H-6-1 106 SPRING HANGER F-A FW ISII-6-1 VT-3 H-23-1-12SS SNUBBER F-A HPCl ISI l-23-3 VT-3 page 4 cf 5

- j Tcbla 2 i

ISI EXAMINATIONS PERFORMED DURING RFO 11  !

4 by General Electric COMPONENT ' DESCRIPTION' CATEGORY SYSTEM ISOMETRIC EXAM i H-1-1-22 RIGID HANGNR F-A MS ISI-l-1 1SH2 VT-3 i

. H-1-1-HA2 SPRING HANGER F-A MS ISI-l-1-1SH1 VT-3 H-1-1-SA1 SNUBBER F-A MS ISl-1-1-1 SH1 VT-3 H-1 1-SA2 SNUBBER F-A MS ISI-l-1-1 SH1 VT-3 H-2-1-H1 SPRING HANGER F-A RECIRC ISI l-2R-A VT-3 H-2-1 H6 SPRING HANGER F-A RECIRC ISI-l-2R-A VT-3 H-2-1-H8 SPRING HANGER F-A RECIRC ISI-1-2R-A VT-3 H-10-1-SS1.9 SNUBBER F-A RHR 1S1-1-10-1 VT-3 H-54-1-SB0 PRV STABLIZER F-A RPV 1S1-1-54-1 VT-3 H-54-1-SB180 RPV STABILIZER F-A RPV 1S1-1 54-1 VT-3 H-54-1-SB270 RPV STABILIZER F-A RPV 1S1-1-54 1 VT-3 H-54-1-SB90 RPV STABILIZER F-A RPV 1S1-1-54-1 VT-3 l l

H-12-1-11 SPRING HANGER F-A RWCU ISI-l-121SH1 VT-3 l

l page 5 of 5 l

l

I Ta bla 3 RFO 11 NONCONFORMANCE REPORTS NCR NO. DESCRIPTION - DISPOSITION MR 97-090 Flaw in core spray weld SWIAN Accept as is 19600303 l 97-091 Flaw in core spray SWIAS Accept as is 19600303 97-092 Flaw in core spray SWlBN Accept as is 19600303 97-093 Flaw in core spray SWIBS Accept as is 19600303 97-068 Flaw in core spray SW8BN Accept as is 19600303 97-086 Flaw in core spray SW8AN Accept as is 19600303 97-106 Thin wall for E/C PT 196 Replace 19600692 97-108 Thin wall for E/C PT 186/187 Replace 19600687 97-064 GB-10-117HL1(4) linear indication Repair 19600301 96-052 JF29-9-1 thin wall Accept as is 19600286 97-105 Jet pump #6 swing gate unlatched Accept as is 19600303 97-117 Jet pump #1,4,7,8,9,16 and 17 Accept as is 19600303 swing gates unlatched 97-124 Tack welds on steam dryer Accept as is 19600303 leveling screws @ 35* and 215*

are cracked page1 of1

TABLE 4 PRESERVICE VISUAL EXAMS PERFORMED DURING 1997

DATASHEET: ' DESCRIPTION) ' SYSTEM ( EXAM TYPE . DATE MR VT-197008 1-VI 203-4A INTERNALS MS VT-3 3/5/97 19601055 VT-10-97002 Temp Support RHR VT-3 2/11/97 19602324 FSKC 97-01-KALB-03 VT-10 97012 H-101-SS21 RHR VT-3 3/3/97 19600645 VT-10-97018 H-10-1-50SH RHR VT-3 2/23/97 19501915 VT-10-97019 1001-2A & 1001-2C RHR VT-2 3/25/97 19602410 CHK VALVES VT-10-97023 H-10-1 SG16 RHR VT-3 4/9/97 19301461 VT 10-97024 H-10-SS25 RHR VT-3 4/3/97 19600649 VT-10-97025 H-10-1-110 RHR VT-3 2/22/97 19301736 VT-14-97001 H-14-1-18S CS VT-3 2/25/97 19600646 VT-23-97002 H 23-1-86 HPCI VT-3 2/18/97 19600651 VT-23-97003 H-23-1 86 HPCI VT-3 2/18/97 19600650 VT 20 97001 TEMP. SUPPORT SSW VT-3 1/28/97 19602273 FSKC 97 01-KAL VT 29-97002 TEMP. SUPPORT SSW VT-3 1/28/97 19602273 FSKC-97 01-KAL VT-29-97003 P-208C PWT SSW VT-2 2/7/97 19503415 VT-29-97004 E-122B CHANNEL HEAD SSW VT-2 2/8/97 19602273 VT-29-97005 E-209B Hx PWT SSW VT-2 2/28/97 19602272 VT-29-97006 - SSW 3822 VALVE SSW VT-2 3/1/97 P9402454 VT-29-97007 SSW 3838 VALVE SSW VT-2 3/1/97 P9402455 VT 29-97008 SSW 3833 VALVE SSW VT-2 3/1/97 P9402455 VT-29-97009~ H-29-1 11 SSW VT-3 3/7/97 19301734 VT-29-97010 E 122B CHANNEL HEAD SSW VT-2 3/13/97 19700390 VT-29-97011 'A' SSW TE-6242 SSW VT-2 3/16/97 19602583 VT-29-97012 'A' SSW TE 3842 SSW VT-2 3/16/97 19602642 page1 of2

TABLE 4 f

PRESERVICE VISUAL EXAMS PERFORMED DURING 1997

'DATASHEET- DESCRIPTION ..  : SYSTEM EXAM TYPE ~ DATE MR VT 29 97013 2" PIPING TO 29-HO-39A SSW VT-2 4/6/97 19503156 VALVE l

VT 29-97014 E 209A HX CHANNEL SSW VT-2 3/15/97 19602270 HEAD ,

VT 30-97004 H-30-1-175 RBCCW VT-3 3/6/97 19301735 97-V-215 ' B-G-2 MS VT-1 3/6/97 19601055 l

97-V-376 B-G-2 MS VT-1 4/4/97 19600731 97-V-270 B-G-2 RECIRC VT-1 2/27/97 1960353 19002762 97-V-271 B-G-2 RECIRC VT-1 2/27/97 1960262 19602762 97-V-299 B-G-2 RECIRC VT-1 3/12/97 P9403213 97-V 301 B-G-2 RECIRC VT-1 3/14/97 19602391 97 V-005 B-G-2 CRD VT-1 1/29/97 N/A 97-V 006 B-G-2 CRD VT-1 1/27/97 N/A 97-V-019 B-G-2 CRD VT-1 2/26/97 N/A 97 V-030 B-G-2 CRD VT-1 2/20/97 N/A 97 V-079 B-G-2 CRD VT-1 2/21/97 N/A l l

97-V-188 B-G-2 CRD VT-1 3/4/97 19600794

{

l l

l l

l page 2 of 2

-2

N TABLE 5 PRESERVICE VISUAL EXAMS PERFORMED DURING 1996 l

1 DATASHEET - DESCRIPTION -SYSTEM- EXAM TYPE- .DATE MR-VT-196002 SRV203-3B PlLOT MS VT-2 4/24/96 19600190 VT 196003 SRV203-3B PILOT MS VT-3 4/16/96 19600190 VT-13-96001 PSD 1301-9 RCIC VT-2 4/3/96 N/A, PNPS 8.5.5.1 l

VT-29-96001 29-HO-58 SSW VT-2 9/17/96 19601977 VT-29-96003 29-HO-3871B SSW VT-2 9/29/96 19500321 ,

i VT-29-96004 29-HO-3972B SSW VT-2 9/29/96 19500316 VT-29-96005 E-209B HX SSW VT-2 9/29/96 19502034 l VT-29-96006 29-HO-3930B SSW VT-2 9/29/96 19502394 VT-29-96007 29-HO-3B to 29-HO-5B SSW VT-2 10/15/96 19500319 i VT-29-96009 P-208E SSW PUMP SSW VT-2 11/12/96 19503413 VT-30-96001 H-30-1-E209A RBCCW VT-3 3/15/96 19502512 VT 30-96002 H 30-1-E209B RBCCW VT-3 3/15/96 19502511 96-V-007 BG2 MS VT-1 5/22/96 N/A I

l l

l l

page1of1

TABLE 6 PRESERVICE VISUAL EXAMS PERFORMED DURING 1995 DATASHEET - DESCRIPTION - SYSTEM- EXAM TYPE :DATE .- MR -

! VT-10-95050 28B VALVE 3/4" DRAIN RHR VT-2 9/28/95 19502914 VT-29-95021 2" VLV RPLMT AT P-208B SSW VT-2 12/21/95 19503377 l

l l

l I

l l

1 1

- i l

I page1ofI

TABLE 7 I

i VT-2 VISUAL EXAMS PERFORMED DURING 1997 SYSTEM PRESSURE TESTS

'DATASHEET-_ COMPONENT:  : SYSTEM, EXAM TYPE ' ~ RUE :MR VT-10-97004 SLT RHR 1 RHR VT-2 2/16/97 N/A j

VT-10-97005 SLT RHR-6 RHR VT-2 2/16/97 N/A

VT-10-97006 SLT RHR-7 RHR VT-2 2/16/97 N/A I VT-10-97007 SLT RHR-9 RHR VT-2 2/19/97 N/A

\

4 VT-10-97008 SLT RHR-10 RHR VT-2 2/19/97 N/A 1

VT-10-97009 SLT RHR4 RHR VT-2 2/19/97 N/A i

VT-10-97010 SLT RHR-1, -11, -12,13, -14 RHR VT2 2/25/97 S9604277 l

VT-10-97014 SLT RHR 2 RHR VT-2 3/6/97 N/A l

VT-10 97016 SLT RHR-3, -8 RHR VT-2 3/6/97 N/A a 4 VT-10 97017 SLT RHR-5 RHR VT-2 3/13/97 N/A I VT-10-97020 SLT RHR-1 RHR VT-2 3/17/97 N/A i

VT-10-97021 SLT RHR-4 RHR VT-2 3/15/97 N/A

\ .

VT-10-97022 SLT RHR-1 RHR VT-2 3/13/97 N/A l

l VT-1197001 SLT SLC-1, -2, -3, -4 SBLC VT-2 2/27/97 N/A

! VT-23-97004 SLT HPCI-2 HPCI VT-2 1/16/97 N/A

! VT-30-97001 SLT RBCCW-1 RBCCW VT-2 2/21/97 N/A

VT-30-97002 SLT RBCCW 3 RBCCW VT-2 2/16/97 N/A i VT-30-97003 SLT RBCCW 5 RBCCW VT-2 2/16/97 N/A VT-54-97005 ANNULUS DRAINS RPV VT-2 2/18/97 N/A VT-54-97006 , ANNULUS DRAINS RPV VT-2 3/13/97 N/A f VT-54-97007 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 PRESSURE TEST I VT-54-97008 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 PRESSURE TEST 1

VT-54-97009 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 I

PRESSURE TEST 4

page 1 of 2 i

. .- - . _ _ - . _ - - - - . . . - . - - - - . - - . - . - . - . . .- . = _ - -

, l

, . . i 4

TABLE 7 VT-2 VISUAL EXAMS PERFORMED DURING 1997 SYSTEM PRESSURE TESTS j DATASHEET/ COMPONENTS ?8YSTEM~ EXAM TYPE ' L DATE MRT VT-54-97010 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 i PRESSURE TEST 4

VT-54 97011 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 PRESSURE TEST l VT-54-97012 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 I

PRESSURE TEST l VT-54 97013 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 i PRESSURE TEST VT-54-97014 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 PRESSURE TEST i

j VT 54-97015 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 l PRESSURE TEST 1

l VT-54-97016 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 i PRESSURE TEST 3 VT 54-97017 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 i PRESSURE TEST i

l VT-54 97018 CLASS 1 SYSTEM VARIOUS VT 2 3/28/97 19602747 PRESSURE TEST ,

i l

VT-54-97019 CLt.SS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 PRESSURE TEST l

I VT 54 97020 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 j PRESSURE TEST l VT 54-97021 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 PRESSURE TEST

{

VT-54 97022 CLASS 1 SYSTEM VARIOUS VT-2 3/28/97 19602747 PRESSURE TEST 4

i d

page 2 of 2

TABLE 8 1

VT-2 VISUAL EXAMS PERFORMED DURING 1996 SYSTEM PRESSURE TESTS DATASHEET.- .

COMPONENT' . SYSTEM EXAM TYPE ' DATE MR VT-29-96008 SLT SSW-2 SSW VT-2 11/4/96 N/A VT-30-96003 SLT RBCCW-6 RBCCW VT-2 8/27/96 N/A VT-30-96004 SLT RBCCW 2 RBCCW VT-2 8/23/96 N/A VT-30-96005 SLT RBCCW-1 &-7 RBCCW VT-2 8/21/96 N/A VT-30-96006 SLT RBCCW-11 RBCCW VT-2 8/22/96 N/A VT 30-96007 SLT RBCCW-3 & -10 RBCCW VT-2 9/3/96 N/A page1of1

. TABLE 9 VT-2 VISUAL EXAMS PERFORMED DURING 1995 SYSTEM PRESSURE TESTS DATASHEETi COMPONENTj -SYSTEM ~ EXAM. TYPE . DATE :MRi VT-10-95046 SLT RHR-1 RHR VT-2 7/17/95 N/A VT-10-95047 SLT RHR-8 RHR VT-2 7/17/95 N/A VT-10-95048 SLT RHR-1,2 RHR VT-2 7/14/95 N/A VT-10-95049 SLT RHR 4,6 RHR VT-2 7/14/95 N/A VT-14-95014 SLT CS-1 CS VT-2 6/23/95 N/A VT-14-95015 SLT CS-6 CS VT-2 6/23/95 N/A VT-14-95016 SLT CS-8 CS VT-2 6/23/95 N/A VT 14-95017 SLT CS-7 CS VT-2 6/23/95 N/A VT-14-95018 SLT CS-5 CS VT-2 6/28/95 N/A VT-14-95010 SLT CS-4 CS VT-2 6/29/95 N/A VT-14-95020 SLT CS-3 CS VT-2 6/29/95 N/A VT-14-95021 SLT CS-1,2 CS VT-2 6/29/95 N/A VT-23-95015 HYDRO HPCI-6 HPCI VT-2 6/5/95 19400658 VT-23-95016 HYDRO HPCI-6 HPCI VT-2 6/5/95 19400658 VT 23-95017 HYDRO HPCI-6 HPCI VT-2 6/5/95 19400658 VT-23-95018 SLT HPCI-2 HPCI VT-2 6/19/95 N/A VT-23-95019 SLT HPCI-3 HPCI VT-2 6/8/95 N/A VT-29-95017 SLT SSW-2 SSW VT-2 7/12/95 N/A VT-29-95018 SLT SSW-3 SSW VT-2 7/12/95 N/A VT-29-95019 SLT SSW-2 SSW ' VT-2 7/12/95 N/A VT-29-95020 SLT SSW 3 SSW VT-2 7/12/95 N/A l

l l

! u page1of1

-__________._________.______.____._______.______.-.__..--.____._.......____.q s

4 SECTION 2.0 NIS-1 AND NIS-2 CODE REPORTS FOR ASME XI REPAIRS AND REPLACEMENTS l

l l

.~ -_ .. . . . . . . - . - . _ - -- - - - - ~ _ _ - . . - . - . . . . - , . . _ . . - ~ . . . . . - . . - .

I I

~

l FORM NIS.1 OWNER $' DATA REPORT FOR INSERVICE INSPECTIONS As vesguired by the Provisions of the ASME Code Rules

i. owner Boston Edison Company' l (Nasme and Addnes of owner)
2. Plant D 41 n r4 m Nnelaar pnwar ttatinn. DFnd1. Dar.kv Hill Rd. p1wmn"th' (Nasas and AdBass of Plant! g
3. Pleas Unic Il 4. owmer Car Misser of Autherisation (if seguired) N/A  !
s. Camawren.1 ser.sa, os.e 12-9-72 4.Na,iamai somd Number f= unit 20763
7. Campeneans laspeseed
  • h. -

Neaufanper l P-

^ ;r -:

er '~ efanufasbwer
orlesenter ' 5eser er 'M ,' . '

er Ineseller Serial No. Provinse No. Seard No.

Reactor Vessel Combustion Erig. 66107 '

66207 20763-pininn Bechtel '

N/A N/A N/A

! I l

' j l

l e

4 l . . .

1

~

Note Supplernental sheets la form of lists, slutches, or drawings sney be used provided (1) sue is 8n in. x 11 in..

(2)informuion in items I through 6 on this data report is included on each sheet. and (3) each sheet is numbered and the awaber of sheets is recorded at the top of abis form.

l I

l j -

1 4

FORM NIS 1 (back) 6-5-95 3-29-977[a, se ,an,em 6-30-9 6 6-30-05

a. saamissiion Da s
masa er w ak mgaand l
u. Abaraa .f r.- uions..See taci.de a sin of esamiassiese and . -w -

ISI Sumary Report f ewnminervat. .

- d**-' #

11. AbsonesofCondacionsN*Yee ISI Summary Report ,

t 12. Abstractef Cometive

- - ' ' end "

. l e ISI Summar M Pt'ind NIS-2 Fonns .

- . ~ ., - ,, .

.e .ic.ft u . '2,r J ..c~. . r, -

. We certify that ehtMteunessa made in this mpers am sorrect and sine___t-aa'a-a and costeetiw sese-

' ~a-i - =. - , . .;

swes enkes conferia ao the rules of the ASME Code,Sessies XI.

k Dase M3 19 97 Signed Bostonifdison owner gy l _

d+- W e 1

usehrh. Maha99f.u' >-

  • v:g '"J*

s a. .<

a

n. .' i.e Certincase of Authorizados No.(if applicable) N /A Empiracien Date ,

CER.TIFICATE OF INSERVICE INSPECTION- -

l

t. the madersigns holding a valid cosamission issued by the National Board of BoDer and Pressure Vessel

,lp and/or the State or Provinee of MaCC

  • and eunployed by'A -G4 < k + u'a of wa t am. MA how inspected ,he componen, described is imis own 6askepg riW in"p' riod e
  • 4170/Q7 . and siste that so she best of my knowledge and belief, the Owner 6/6fQ4 to has performed examinations'and takes somedve anesseres.deserbed is this Owners' Data Report la asserdamer

! with she requiremenu of the ASME Code.Section XI.

By signing thh eerdficate selsher the laspecear nor bis employer snakes may watranty.aspressed or hapC concerning the ="- - and sometive measmes described la this Owners' Data Report. Furthermore, neither the laspector met his e.ployer shall be liable in any mammer foe any pareenalisjury or property desmage er a loss of any kind arising from or commeeted wish this inspeedes.

Date . [- Y - 1@

b48 c.. r d- MA 1470 National 5eard. $ taw. Province and No.

% % 's5 5 aasm '

  • V e

~~ .

(

esame m

1 I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI B~'= Fdi- Co Date 5/16/94

1. Owner Nams 800 Bov1=*= Street W MA Sheet 1 of 1 Addrums
2. Plant Pilaram N-1==* Power R'**i= Unit 1 Names 600 Da+v Hill Pand Pim*h MA 02360 MR 19401118 Addrums Espah- Orgmassamen P.O. No., Job No., sec.
3. Work Perfanned by p-'= Fdi- cc Type Code SymbolStamp N%

"" AuthermationNo. N/A 600 Pu lev Hill Pa-d Pivmouth.MA 02360 Experation Date N/A Addrums 4 Manhnr= tion of System P- ida=1 Hat Pa=aval ,

5. (a) Appbcable Construction Code ANSIB31.1 19.6LEdition, . Add- da Code Case (b) Appbcable Edition of Section XI Utiliasd for Repairs or Parl-** 19 12
6. Mantine=*wm of Components Repaired or Replaced and P - -----" CP '

I National Repaired, ASME Name of Name of Manufacturer Board Other Year Replaced, or Code Ca----at Manid=cturer Serial No. No. Identification Built Replacesnant Stamped (Yes or No)

Support N/A H10-1 102SH Repair N/A

7. Desenption of Work P=ie ==aa t ner FRN 94 0109.
s. Test ca a-*d Hydrostatic 0 P-=~ O NommalOperatmsPressure O Other O Pressure esi TestTant. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawar,s may be used, provided (1) size is 8% in. x 11 in., (2) informa-tien in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtamed from the Order Dept., ASME, 345 E. 47th 9., New York, N.Y. 10017

I t .

l t

r 4

FORM NIS-2 (Back)

9. Remarks Thi5 l

2 WAS A EfO /O t&

Apphanbieu-% Dess = ; ; id.he d-l 'A')

i l

I.

1 i 8 CERTIFICATE OF COMP CE We certify that the statamants made in the report are comet and this ASME Code, Section XL VdfA. conforms to the rules of the supeir

(

i Type Code symbolStamp bd I

Cernfimte ofAuthanzataan No. O 11 FW_ Date Signed 7w [et 74 Date 4,[6 .199'7 Ow.wir or Owner's NP. Title i

! CgR. trICATE OF INSERVICE INSPECTION 1, the vieregned, hokhng a valid na=====on i sued by the National Board of Boiler and Pressure Vess

! of u==

and employed by Arkwnsht h_ utual Ins, Co. of Waltham Mann. have inspected the tvunpanants descri in this Owner's Reports during the period J <- 95

to .4-M- 9 7 . and state that to the best ofmy knowledge and belief, th- Owner has performed exammations and taken corrective measu

, Owner's Report in accordance with th We mts of the ASME Code, Section XL a

]

j By signag this cerhfi=ta neither the Impaction nor his employer makes any warranty, expressed avami==hr=2s andcorrective measures destribedinthis Owner's Report.

! Furthennare, neither the laspector nor his anployer shall be liable in any manner for any personal iqjury or property damage or a loss of any kind arisms from i f 6 i

l ""  !

/

FV cammimawma MA-1420 1 Bipasure Nanomal Bosni, anste, Pnmens, and Eadorusumans

{ nuns 4-9 to f'7 -

i

]' (1242) e 4

1 l

i n  !

I i

4 i

1

FORM NIS-2 0% NER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Date. 3/14Mf97

1. Owaar N= Edia Co s

Nams 1 c( 2 800 Bowlsten Street. Naa MA Sheet _

Addess Pdem N 1= Powermad= Unit i

2. Plant Nams MR 19601060 600 RockvMill PanA Pimah MA 02360 Rapanr. - P.O. No., Job No, etc.

Addnes w= FAi- Co Type Code Symbol Stamp N/A ,

3. WorkPerfanned by

"'"' Authonzation No. N/A 600 Rocky Hill Road. Pimah MA 02360 Expiration Date N/A Addas.

4. Haneiru atian of System u.;.m --g.-- .

19 58 Edition. Add-via, code case

5. (:) Appbcable Constnetion Code ASMEIII (b) Appbcable Edition of Section XI Utahzed for Repers or Replac,m,nts 19 12
6. Identdication of Components Repaared or Replaced and Replacement Components National Repaired, ASME Manufactwer Board 0%r Year Replaced, or code Name of Name of Identification Built Reptaramant Stamped ce Mannracturer SerialNo. No.

(Yes or No)

Safety Relief Target Rock SRV Pilot ~ RV-203-38 1995 debuilt Yes Valve Solenoid Ses =-- ' : _' _- - " -  : ; i f

7. Description of Work hi- m*=
8. TestConducted: Hydrostatic Pneumatic C NamnalOperstmgPresswe Other C Pressure poi TestTemp. *F NOTE Supplanental sheets in fann oflists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This fann (E00030) may be obtamed from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017

_. _ _ . - _ _ _ . _ . _ - . _ . _ _ - . - . _ . - _ _.._ ..._. .~ -_--. _ .

.._._.._.__-..._..___._____.m _ _ . - _ -

l FORM NIS-2 (Back) l' l

9. Ranarks Four body to base ==*= r=la~d with Tweet Rock snares ===liad by BECo Apphenbieu-h-ers Du,a Reports to be sanded 1

l 4

l i

\

l CERTIFICATE OF COMPLIANCE

( We cerary that thematana=*= made in the report are correct and this _ conforms to the rules of the ASME Code,Section XL repair er! ' '

%/

Type Code Symbol Stamp b d Certificate of Authonzation No. k d Expuntion Date Signed I / w /ri V Date 4./F .19*77-i Ownero Owner'sDesigsee, Title l l

CERTIFICATE OF INSERVICE INSPECTION I 1, the undersigned, holding a valid canmiamion issued by the National Board of Boiler and Pressure Vessel 1==partars and the State  ;

of Mass and employed by Arkwruht u.*=1 Ins. Co. of Walth== u.. . have inspected the canpanante described in this Owner's Repons during the period I- c 4.fo 4 29-4~7 . and state that

, to the best of my knowledge and belief, the Owner has performed avaminatiana and taken corrective maaewas described in this l Owner's Report in accordance with the requiremsets of the ASME Code, Sachon XL By agmng this certificate neither the Piaa nor his employer makes any wnrranty, weJ or implied, concenung the vaminahana and corrective measures described in this Owner's Report. Fathermore, neither the Inspector nor his employer shall be liable in any te.manar for any personal injury or property damage or a loss of any kind anang from or connected with this aspechen.

/ /kN

  • Cammismons MA-1420 Dia.

w y( m - 7 19 f 7 (12/82) ,

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMEN'I3 i

As Required by the Provisions of the ASME Code Section XI waa Fdi- co Date_. 3/2/97

1. Owner Name R00 Bowlston Street han MA Sheet 1 of 1 Amns
3. Plant Pilmm M Power **a+iaa Unit i Nams 600 na lv Hill nand PI-=*h MA nnati MR 19700576 Ammes Rapnire. - P.O. No., Jeb No., anc.
3. Work Perfanned by w Ndi- Co TypeCode SymbolStamp N/A Name N/A Authenzaban No.

600 D-hv Hill PaaA Plvman'h MA 02360 Expiration Date N/A AMma

4. hhncahan ofSystem RHIL M01001-29B. mor y c = 1 Valve
5. (a) ApplicableConstruction Code B31.1 19_62 Edition, Addenda, Code Case i l

(b) Appbcable Edition of Section XI UtilLd for Repairs or P=?-- --- --ts 19_32

6. Idenhnc=han of C+--r-=- = Repalad or Replaced and Replanamant C-----i+= =

j National Repaired, AShG  !

Name of Name of M==uf=enwer Board Other Year F 1". or Ccde c-+ Manufachwer- Serial No. No. Idanhnc=han Built Rept - ' Stamped l (Yes or 1

&)

MO 1001-29B Anchor / Pads Gate Valve Darlina Replaced No I

1

. )

7. Description of Work P=i" ar--e hanadary marts (dine. hahine)
3. Test ca dari-i Hydmetatic0 Pneumauc 0 NommalOpastmgPnssure O Other O Pressure nei TestTemp. 'F NOW.: Supplemental sheets in form of lists, =ketche=, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets.is recorded at the top of this fonn (12/83) *nais form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017

FORM NIS-2 (Back)

9. Retraks -. .

Applacableu-af.,e-er's Data Reports to be smached

.w :.. . .

.,*,e i

! CERTIFICATE OF COMPLIANC5%""-

! We certify that the statements made in the repost att correct and this conforms to the rules of the ASME Code,Section XI. nysirer 1 z.:x.3 J.W. 1

) Type Code S)1nbol Stamp A  !

_. . r . e _

, Certificate of Authoruation No. N' A 'Y';N?NINe i

Signed fr1 74 V S' & 4f3 .1917 j Owner or Owner's Designee, Title -. .

l

, CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid crunmi== ion issued by the National Board of Boiler and Pressure Vessel Inspartars and the State i of Mass and employed by Arkwrinht Mutual Ins. Co. of Waltham Mast have in ivre u the en=panents described i in this Owner's Reports during the period 4 - s-fSto 3-M--9 7 . and state that to the best of my knowledge and belief, the Owner has performed av====hant and. taken coricctive measures described in this Owner's Repcrt in accordance with the requirements of the ASME Code, Section XL

~

By sigmng this certificata neither the Inspection nor his nnployer makas anyimitenty, wJ or implied, concerning the i examinations and carective measures describeciin this Owner's Report. Fidesr se, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss ~of ~any' kind arising from or cannardarl with this  !

M"I x ""

Bigesame Cnmmissions MA-1420 National Board,mata, Frowbos, sad Endorseassses j

l Date _ S 4-19 Y 7 . _ . . . _ . .

O '* E e..e g d i 1

l l

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI w- FAiaan Co Date 7/12/96

1. Owner Nams 800 Bovt=*= Street. N=*= MA Sheet I of' I Addrus Pdenm N-1= Power **=*i- Unit i 2 Plant Name MR 1950!362 600 Daciw Hill Pa=A Pivm-th MA 02360 Rapare. P.O. No., Job No., sec.

Address

%= FAiaan Co TypeCode SymbolStamp N/A )

3. Work Perfanned by

"'"' AuthonzationNo. N/A l Expiration Date N/A 600 B ~+v Hill Pa=A Pivmanth MA 02360 Addres

4. IdentificataanofSy=*= RHR f

19 67 Edition. Addanda, Code Case

5. (a) Apphcable Construction Code B.31.1 (b) Appbcable Edition of Section XI Utilized for Repairs or P;' -ts 19 32
6. Identification of Components Repautd or Replaced and Replacement Components

}

J I

National Repamd, ASME i Name of Name of Manufacturer Board Other Year Pi t ". or Code l l

No. Identification Built Rep 1=c==an' Stamped Component Manufacturer SerialNo.

(Yes or l l

No)

N/A MO 1001 18A N/A R.,,;  ; ; No 1 3' 300lb Velan N/A Gate Valve ( PAA*rs) l l

l 7 DescriptionofWork P- ' valve disc.

8. Test C 8 " Hydrostatic 0 Pneumatic 0 NarnmalOperatingPressure O Other O Pressure osi Test Temp. 'F l NOTE: Supplemental sheets in fann of lists, sir eche=, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtamed frota the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017 l

l

_ . - . .- =-.-- - . - _ . . - . - - . _ . . _ - - -

1 l FORM NIS-2 (Back)

9. Remarks renlacement ner PDC E10A Apphanbie M*-ers Data Rapons to be anaded CERTIFICATE OF COMPIJANCE We certify that the =tatemente made in the report are correct and this - conforms to the rules of the ASME Code, Section XL repair Type Code Symbol Stamp h M Certificate of Authernation No. b. Id Expiration Date Signed wM / Date 6/3 .1997 Owner or Owner's Desigdse, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid trunmission issued by the National Board of Boiler and Pressure VesselInspecton and the State of Mass and employed by Arkwrimht MutualIns. Co ofWaltham Mass. have inspected the compone:sts desaibed in this Owner's Reports during the penod 4 -$ -fTto 3-#M '7 . and state thr,t to the best of my knowledge and belief, the Owner has performed exammttions and taken corrective measures described in this

)

Owner's Report in accordance with the requirements of the ASME Code,Section XI. l By signing this certificate neither the Inspection nor his employer makes any warranty, w /. or implied, concermng the examinations andcorrective measuresdescribedinthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ansmg from or connected with this {

inspection. I M* r'nmmienions MA-1420 Date y .-

6 #f -1997

-~~

(12/82) .

l l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

%= FAiaaa co Date 3/11/97

1. Owner Nams

. heet S I of I 800 " ;M= Street _ b-*aa MA Addnes Pilerim N~I- Power **=*i- Unit i

2. Plant Neow MR 19600301 600 Rackv Hill Paad Piv==*h MA 02360 RepairP. - P.O. No., Jub No., sec.

Addnes haa Fdi- Co T3pe Code SymbolStamp N/A

3. Work Perfanned by Authonzaban No. N/A 600 Rocky Hill Da=A Plv==*h MA 02360 Ewaie=*iaa

' Date N/A Addnes

4. Idantificatian of System RHR . c.r.ey r i e 2 19 67 Edition, Addenda, Code Case '

) 5. (a) Applicable Construcuan Code B.31.1 (b) Applicable Edition of Section XI Utilized for Repairs or Rept cnn nes 19_.12

6. Identifiention of Companente Repaired or Replaced and Replacement C&*=

l National Repaired, ASME Mmufacturer Board Other Year Replaced, or Code Name of Name of SerialNo. No. Identi5 cation Built Peplananent Stamped Ort Manufacturer (Yes or No)

RHR Pipe Weld # OB- Rw No 10-117 HLl(4) r

7. Description of Work Wald mir RHR nine due to MT infie=*iaa
8. TestConducted Hydrostauc0 Pneumauc 0 NanunalOperatingPressure O Other O Pressure esi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8Y in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fonn.

L (12/82) His fann (FA0030) may be obtamed from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017 i

l

l FORM NIS-2 (Back)

9. Remarks Refer NCR 97-064 Appiscable bl=hver's Data Repans to be anseed l

l CERTIFICATE OF COMPLIANCE We certify that the *=tamanta made in the report are correct and this conforms to the rules of the i' ASME Code, Section XL repair er Type Code Symbol Stamp k Certificate of Authorustion No. L) 10r Expiration Date Signed

~

7 m In '7M Date 4/3 .199 7

( Owner or Owners Desij(nee, Title I

l CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commi== ion issued by the National Board of Boiler and Pressure VesselInspectors and the State of Mass and employed by Arkwrimht Mutual Ins. Co. of Waltham Mass. have inspected the components described in this Owners Reports during the period 4 -S-Ps% 1 Af-f'7 . and state that l

to the best of my knowledge and belief, the Owner has performed erammations and taken corre' tive e measures described in this Owner's Report in accordance with the requirementa of the ASME Code,Section XI.

By signing this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, concerums the examinations andcorrective measuresdescribedinthis Owners Report. Furthermore, neither the Inspector nor his employer ,

i shall be liable in any menner for any personal injury or property dar age or a loss of any kind anang from or v =- '=-f with this ia&_

1 AM, - c i ions MA-1420 l Date pp n 4 1997

-~~

l (12/s2) _.

l l

i i

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Prwisions of the ASME Code Section XI

~

n~e- FAiaan Co Date 2/4/97

1. Owner N _ _

800 "sv'A.:: Street n~eaa MA Sheet 1 of 2 l

2. Plant Ptlanm Niel==r Power Rh Unit 1 Name 600RockyHillP=A Pim*li MA 02360 MR 19600794 Repair e . P.O. No, Job No., sec.

Mems B~em FA6 Co

' TypeCodeSymbolStamp N/A - . -

3. Work Perfonned by Nams -
j s AuthonastionNo. N/A 600RockyHillRoad. Pim*h MA 02360

' E_W Date N/A ug,,, ,.~% ,

4. IdentiScauen ofSystem C---rei Rod Drive Unit .

~ ~

5. (a) ApplicableConstructmnCode ASME1H i9. gl Jdition, A M=ta, Code Case (b) Applicable Edition of Section XI Utahand for. Repass or 89 - fa19 J 1
6. Identincation of Components Repaired or Rtplaced and Ref-ae Components - . . .

i

' I I I National Repaued, ASME Name of Manufactmer Board Otter Year Replaced, or Code l . Name of l C =__aaaaa' Manufacturer SerialNo. No. Idenht'iratian. Built Rt-t Stamped

.GBD (Yes or 14 35 No) .

02-27

~ 18-15 Rebuilt by 02-1: 1995 Rebuilt Yes CRD 8'C* Ei' 38 47

'3447 14 03 10 !!

22-27 .

l 1 M7 l 42 15 384:

I -- -

Is-19 l

7. Description of Work Exchanne CRD. renlaos can acrew.
8. Test Conducted: Hydrostatic 0 Pneumatic 0 NanunalOperstmgPressure O Other O Pressure Clgis I leak check pod Test Temp. , *F An in-service inspection perfanned of the mammbly CRD unit when used in the vessel with no visible leaks allowed - VT 2 examinati NOE: Supplemental sheets in fann of lists, airmedwa or drawings inny be used, provided (1) size is 8% in. x 1I in , (2) informa-ion in items 1 through 6 on this report is hacluded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. ~ -

(12/B2) This form (E00030) may be obtaital from the Order DepL, ASME, 345 E. 47th St. New York, N.Y. 10017

Y FORM NIS-2 (Back)

9. Remarks wg y=e_ ....s. pas, g, parts to be aw

, CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are carnect and this _

conforms to the rules of the ASMB Code, Section XL repelr or ? "-~'

V Type Code Symbol Stamp b )N Certificate ofAuthorization No. M Expiration Date Signed e 6., A 7'd I/

' Owner %r Owners DesignM, Title

__ Date 4/3 .19 9"7 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commmion issued by the National Board of Boiler and Pressure Vesse! Inspectors and the State of Mass and employed by Arkwvirht MutualInt Co of Waltham Mass. have m' spected the 0eg--=ts described in this Owner's Reports during the period # - <-45to .7-MM 7 . and state that to the best of my knowledge and belief, the Owner has performed evaminations and tak'en corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL By sigmng this certificate neither the Inspection nor h!s' employer makes any warranty, orM or implied, concerning the '

examinations and contetive measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind ansing from or e=W with this in8Pectiert

/XAf M A - C- =iadons MA-1420 V' /Impasar'sSisonnar Etional Boent, Stata, Pnmnos, and he Date [ i - 19 7 (12/82) ,

l l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Date 2/31/97

1. Owner Ba='= Fdiaan Co Nams J Stact 1 of 1 800 Bevision Street _ Ba-'aa MA l Unit I
2. Plant Pilmrim N 1**e Pomr **daa

. Naas 600 RockyHillRoad PI wh MA 02360 MR 197000296 & 19600577 Rapeir Orymnastana P.O. No., Jeb No., sec.

Addma Type Code Symbol Stamp ' N/A

3. Work Perfonned by' Nataa FAlaan Co Nms Authanzation N'o. N/A Expiration Date 'N/A 600 RockyHillRoad Plea =*h MA 02360

^"*

4. identifwationofSy='= Ra aladan Swtem
5. (a) ApplicableConstnactionCode ASMEIU 19 ,Jditioc, 29 'NM' Code Case (b) Applicable Edition of Section XI Utahzed for Repsirs x Paa1-h 19 12 a _
6. Identification of Components Repaired or Replaeniand Pap! rarnant Components _ ,

l Repaired, ASME National Other Year Replaced,or Code Namecf Name of Mannfacturer Board No. Identification Built Paa1 ~=aaat Stamped N:=nt Manufacturet SerialNo.

(Yes or No)

Recire. Pump Bryan hekaan Pump 201 A Decon Raa1 ==" No and B Flange

7. Description of Work Raalare dacaa f1===a ** and nuts.
s. TestC*4 Hydststatic0 Pneumatic 0 NarninalOperatingPressure O other O Pressure esi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the numbe of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtamed from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

_ _ . . _ _ _ _ . . _ _ _ _ _ _ _ _ _ _ - . . . . _ _ _ _ ___ _. _ _ _ .m._ _ ._

I FORM NIS 2 (Back)

9. Remarks Refer to FRN 96-01 158 =ad 97 01-25 Appbsmbi. u-r.,*= r% Dess Raports to be asased l

1 1

1 I

.a g

--;+-- CERTIFICATE OF COMFLIANCE ^- , e :-

We certify that % staten ats made in the'M are corred and this confonns to the ruleskthe 1 ASME Code, Sec%n XI. />> J u supeirw' ' '"

>sr. -

l l

l

g, + . w,@t.s Type Code SymbolStamp V l_4 1 Certificate ofAuthonzation No. N d t' Expiration Date Signed }$lDw :7;4 V-' -~ Date 1./3.:1997--

Ownefor Owner's M. .*fitle CERTIFICATE OF INSERVICE INSPECTION l I, the ;r d.sr.ig d, holding a valid ===le= ion issued by the National Board of Boiler and Pressure Vesse! '@.and the State of Mass and employed by Arkwight Mutual Ins. Co. of Waltham. Mass have inspected the components described in 8 Owner's Reports during the period 4 - r-f83o 3 .A9- 9 7 . and state that to the best of my knowicdge and belief, the Owner has performed ex==inations and taken corrective measures described in this Owner's Report in accordance with the iw  :. of the ASME Code, Sectico XI.

By gnag this certificate neither the Inspection nor his employer makes any warranty, wd or imphed, concermng the ex==inations and corrective measures describedin this Owner's Report. Furthermore, neither the Inspector nor his sunployer shall be liable in any manner for any personal igjwy or property damage or a loss of any kind ansing from or ==ar**d with this

s. t,

^

M- Commissions MA.1420 sipumure Nasiamat soent, state, Pnmane, and Enderesmauls Date d *'Y- 19 7I 02/82) 4

4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 5-*= sdi- ce Date 3/14M7

1. Owner Nams 300 Bowl ='aa Street %=*= MA Sheet 1 of 1 Mdans
2. Plant Pilerim N= 1==e Power R*=*i- Unit 1 Nams 600 ma tw Hill Dand Pivaw=4 MA 02360 MR 19602410 Mdnas Repaire. P.O. No, M No., sec.

' ' ~

3. WorkPerfonned by Will"- is Type Code SymbolStamp N/A .*

Authonzation No. N/A

_ hai=+4aa Date N/A m .

4. Manhfimhan ofS; " RHR
5. (a) AppbcebleConstructionCode B31.1 19.E Pdi*i- _^ dd-ada coa Case (b) Apphable Edition of Sachen XI Utahzed for Repairs or Dapla==w='s 19 32
6. Identification of Components Repaired or Replaced and RepIntement C----i = =

l National Repshed. ASME Name of Name of Manufactmer Board Other Year Replaced, or Code Ca-a--' Manufacturer SerialNo.- No. Menhfimtian Built R*=i-t Stamped (Yes or No) ..

l l

Check Valve Anchor / Darling ADV

  1. W9324070 10012 A/C Replaced No l

(fM1tf!r) .

l l

6

7. Denmphon of Work .Esalace *" valves and aiaal-
8. Test t's=d=*=1 Hydmetatic Paa==a'e NommalOperntingPressure Q Other Prinsme nei TestTemp., _'F NOTE: Supplemental sheets in form of lists, sketches, or drawags may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/52) This form (E00030) may b, obtained from the Order Dept., ASME,345 E. 47th SL, New York, N.Y. 10017

FORM NIS-2 (Back)

9. Remarks FRN 97-01-13.

Appixable M-r--Ws Data Repats to be =mW CERTIFICATE OF COMPLIANCE We certify that the statemmts made in the report are correct and this confonns to the rules of the ASME Code,Section XL repair Type Code SymbolStamp A A .

Cerhficate ofA*Weion No. d i M.

Expiration Date Signed . L//s /,. 7'2f V Date d[f .197'/

Owns or Owners Designise, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid mmminion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State i of Mass and employed by Arkwriaht Mutual Ins. Co. of Waltham Mass. have inspected the E-g--=ts described in this Owners Reports during the period 4- f-feto 2-M-97 . and sta*e that to the best ofmy knowledge and belief, the Owner has performed examinations and take' n corre6tive measun:s described in this Owner Report in accordance with the reqmrements of the ASME Code, Section XL By sigmng this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, concermng the

l. examinations andcorrective measures describedinthis Owners Report. Furthennore, neither the Inspector nor his employer i shall be liable in any manner for any personal injury or property damage or a loss of any kind ansing fmn or -*M with this -

j mspection.

I I #

s j 1/ h N - Ccmminions ___MA-1420 Nasicaal Board, State Prwuxe, aml Endrumses j

'/ ' [ vw signenne j Dess d 19 Y t

(12/12) ,

P b

'1*"""

FORM NLv2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI B-eaa FAi.aa co Date 5/30/96

1. Owner Name 800 Bovidaa Street. Dadaa MA Sheet 1 of 1 Merum Pilmm Nael~e Power Station Unit 1
2. Plant 1 Na=8 600 Rocky Hill PaaA Plymouth. MA 02360 MR 19601057 Raynar C- . " P.O. No., Job Na, etc.

Mdress B~t= FAi- Co Type Code SymbolStamp N/A

3. Work Performed by Authorustion No N/A 600 Rocky Hill Paad Plvranadh MA 02360 Expiration Date N/A Merus
4. Identification of Systan Main Se== Svssn 19 68... .hdition, Addenda, Code Case
5. (a) ApplicableConstructionCode ASMEIII (b) Applicable Edition of Section XI Utilued for Repairs or Repla=nemte 19 12
6. Identification of Components Repaired or Replaced and Replacement Components I

National Repaired, ASME Manufacturer Board Other Year Replaced, or Code Name of Name of Sesial No. No. Identification Built Reptamaaat Stamped Caraaaaaa' Manufacturer (Yes or No)

BK 6309 RV-203-4A 1995 Replacement Yes Safety Relief Dresser Valve l

l 7. Description of Work Paal- evidiae RV (BK 6302) with recer+1fied itV (By Wyle Imb) BK 6309.

l

8. TestCW HydrostabcO Pneumauc 0 NommalOperstmgPressure O
Other O Pressure osi Test Temp. *F NOTT. Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/E2) This form (E00030) may be obtamed from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017

l l FORM NIS-2 (Back) l

9. Remarks Appbcable Ma.ufamma's Desa Reports to be anached CERTIFICATE OF COMPIJANCE l We certify that the at='emente made in the report are correct and this conforms to the rules of the ASME Code,Section XI. pp.ir er ' -

1 Type Code Symbol Stamp A Certificate of Authonzatinn No. d Expiraban Date l

Signed dw M 7WV Date 4/5 .199 7 Dwns or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION l 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel *@. and the State of Mass and employed by Arkwriaht MutualIns. Co of Walth m u. .

have inspected the ,--, ===ts described i in this Owner's Reports during the period /- r- 9_4~to .7 ,24 - f 9 . and state that to the best of my knowledge and belief, the Owner has performed ==mmatinne and taken corrective measures described in this i Owner's Report in accordance with the reqmrements of the ASME Code,Section XI.

By signing this certificate neither the Inspection nor his cunployer makes any warranty, w d or implied, concermng the evaminations and corrective measures described in this Owner's Report. Furthermore, neither the Inspartnr act his empic'yer

l. shall be liable in any manner for any personal injury or property damage or a loss of any kind anang frorn or caniwrtad with this l

l h , c'nmmienions MA-1420 p' y se n m u w n . u a.

o I t. t,9 7 -

(12/82) .

}

f

-_. _ _ __ ._______._____.-___..._..m_.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Dad- NAi- Co Date 5/13/97

1. Owner Names 800 Bovidan Stmet Da=*aa MA Sheet 1 of 1 Mdess
2. Plant Pilarim N= t==r Pimer *=*i- Unit 1 Names 600 DacityHill #a=A Pl-=*h MA 02360 MR 195001788 Menes Repair Ossmaissaem P.O. No., Job No., etc.
3. Werk Perfonned by Dad- FAi- Co and Type Code SymbolStamp N/A Nms N/A Authorumban No.

W-1A;a= Services lac Expiration Date N/A Mdess

4. Idsmeikatum of System RHR
5. (a) Apphcable Construction Code B31.1 19ft2 Editim Addenda, Code Case (b) Appbcable Edition of Section XI Utahzed for Repairs or Replarwwn's 19.,J2
6. Identification of Components Repaared or Replaced and Replacement C==-ts l

Nabonal Repaired, ASME Name of Name of Manufacturer Board Other Year Replaced, or Code C&t Manufactuer Serial No. No. Identification Built Replar===nt Stamped (Yes or l

No) l Support at Valve BeCo 1997 Repair No

! 10 CK 1001-2A i

l I

7. Descripuan of Work MaAiry and r= iaditt new nine ==aaa t at valve 10-CK-101-24 ner FRN 97 0161.
a. Test Conducted: Hydrostauc0 Pneumatic 0 N==1OperetagPnnsure O ,

other O Presswe osi Test Temp. _'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) endi sheet is numbered and the number of sheets is recorded at the top of this form.

(12/B2) " Ibis form (E00030) may be obtamed from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017 l

l l

l  !

\

1 l- - ._ _ _ _ _ _ _ - - - _ _ _ _ _ - _ _ _ _ - _ - - = _ _ _ = = -_ -

l l

l l

1 i

l FORM NIS-2 (Back)

9. Remarks Appbcable Manufassurw% Data Rapats to be starhad l

i 1

l I

CERTIFICATE OF COMPLIANCE ,

We certify that the statements made in the report are correct and this _ conforms to the rules of the ASME Code,Section XI.  ;' -

Type Code Symbol Stamp d Certificate ofAuthoruation No. N Exptration Date 1

Signed 2//w T4 V Date S .1997 l ~ Owner or Owners DesySee, Title l

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid mmmiteion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Mass and employed by Arkwrinht Mutual Ins. Co. of Waltham Mass. have inspected the components described in this Owners Reports during the period t- c-9Cto 1-l#--7 7 . and state that to the best of my knowledge and beli4 the Owner has performeil exammations and taked coirective sneasures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By sigmag this certificate neither the Inspection nor his employer nakes any warranty, expressed or implied, concerntng the examinations andcorredive measuresdescribedinthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind artsing from or -W with this mspectiort b Commissions MA-100

, dad. % . - ---

osi. u- i,97 (12n1) l l

l l

i i

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Sectica XI Date sns6 g, % n-r= Fai.aa co Nams 1 f Sheet 1 of_

too he'"'a L._;. Da=*an MA Ames Unit i

2. Plant Pilmm N=' =r Power **=+1aa Nams MR 19501915 600RoelvHillDaad Pl==8h MA 02360 _ ^ P.O. No., Job No.,ses.

Repair C, ,

Adess Type Code SymbolStamp N/A

3. Work Perfonnedby ne= FAi- co N'"' Authorizatum No.

N/A Expiration Date N/A 600 Dackv Hill Daad Plweek MA 02360 Ames

! 4, ta,ntikatinn of System Dudaaf Heat 8--wel

.*ddaada - CodeCase 19.4LEdition, i 5. (a) Applicable Construction Code ANSIB31.1 (b) Applicable Edition of Section XIUtahasd for Repairs or Replarminante 19 32 '

(

6. Identification of Co= -:=- - 2 Repaired or Replaced and Replanernent Ca===aaaate l

' Repsued. ASME l

National Year Replaced,or Code Manufacturer Board Other I Name of Name of Built Replacernant Stamped SerialNo. No. Identification Cet 3' - '= : - w (Yes or No)

P-i N/A N/A Hlo-150SH .

Support

7. Descriptim of Work Add .etero,, w..- M:n f' --- = or =- '--S e ---- - O --
8. Test 09-+ Hydrostatic 0 Pneumatic 0 NouunalOperstagPressure O Other O Pressure nei TestTemp. 'F NOTE: S'gp= - ' ' sheets in form of lista,4 ache =, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) inf tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o rmorded at the top of this ferm.

This form (E00030) may be obtamed from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017 (12/82)

I i

. \

l 1

l i

l FORM NIS-2 (Back) l l

9. Remarks t

'r'" ManufachrWs N R.,,,  ;. to be anM I l

l l

CERTIFICATE OF COMPLIANCE We certify that the statemente made in the report are correct and 6 ASME Code, Section XL '

conforms to the rules of the apeir or ^ '

i O 1 l

Type Code Symbol Stamp l\ A .

)

Certificate of Authonzation No. h ./d.

Expiration Date Sign:d _ l.< / e [.es WV Date 4/3 .1997

' owifer or owners Designee, Title l

CERTIFICATE OF INSERVICE INSPECTION CERTIFICATE OF INSERVICE INSPECTION I, the understgned, holding a valid enmmmion issued bv the National Board of Boiler and Pressure Vessel Inspectas and the State of Mass and employed by Arkwrinht Mutual Ins. Co. of Waltham Mass. have inspected the en= nan-ats described in this Owners Reports during the period g c.35To T 2 9 7 . and state that to the best ofmy knowledge and belief, the Owner has performed n=mmations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XL By signing this certificate neither the Inspection nor his employer makea any warranty, @J cr implied, enneemiaa the naminations andcorrective measuresdescribedinthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this mspectim. j hh Cammmions MA-100 w

yp M- t#17 (12/82) i l

t I

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Boston Wi== Co Date 1/24/96

1. Owner Name 800 Boylston Street. Boston MA Sheet 1 of I

/ ddress

3. Plant Pilarim Nuclear Power Station Unit 1 Nams 600 Rocky Hill Road. Plymouth. MA 02360 MR 19503321 Addnes Repair Orgaamnaa P.O. No., Job No., etc.
3. Work Performed by Boston FAson Co Type Code Symbol Stamp N/A i

N'"'

Authaustion No. N/A 600 Rocky Hill Road. Plymouth. MA 02360 Expintion Date N/A Addams

4. idertification of System RCIC f
5. (a) Applicable Construction Code ANSIB31.1 19.62 , Edition, AMenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs a Replacements 19 j2
6. Identificaen of Components Repaired or Replaced and Replacement Components National Repaired, ASME Name of Name of Mmurent Board Other Year Replaced, or Code Serial No. No. Identifierdon Built Replacement Stamped Cw&t Manufacturer (Yes or No)

RCIC Rupture BS&B 'DV" PSD 13019 1995 Replace No Disc I .

7. Description of Work Reclace RCIC rupture disc. PSD 1301-9 with an innved design oer FRN 9543-157.
8. TestCMM Hydrostatic Pnaunatic 0 NommaiOperatingPressure @

Other Pressure osi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x i1 in., (2) informa-tion in items 1 through 6 on this report is included on each sie:t, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fonn.

(12/82) This form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

FORM NIS-2 (Back)

9. Remarks PSD 1301-9 replaced oer FRN 95-03157. Ruoture Dise meets ASME Section III Class-I burst test certification.

Apphcable MamfacusW Dera Reports io tw anadwd CERTIFICATE OF COMPIJANCE We certify that the statements made in the report are correct and this _ confonns to the ndes of the ASME Code,Section XI. repairer I Type Code Symbol Stamp N Certificate of Authonzation No. 4 Expiration Date Signed /w /e,74/ Date M3 .1997 OwEer or Owners Desighe, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commtssion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Mass and employed by Arkwright Mutual Ins Co. of Waltham, Man have inspected the components described in this Owners Reports dudng the period I-S- FS'to T-M- 97 . and state that to the best of my knowledge and belief, the Owner has performed exammations and taken correciive measures described in this Owners Report in accordance with the i%6sts of the ASME Code,Section XI.

By signing this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, c==ine the examinations andcorrective measures describedinthis Owners Report. Ftuthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or eaa*a4 with this _

inspection.

/b, , C-minions MA-1420 jr s-a t,n u m mai.,,r. % .a t a - .a.

(12/82) m _ ____

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Boston M*= Co Date 3/14/97 mme 800 Boylston Street. Bostm MA Sheet 1 of 1 Merena
3. Plant Pilerim Nuclear Power Station Unit I mas 600 Rocky Hill Road Plvmoutit MA 02360 MR 19600734 Mereen Repair Ory.amhaa P.O. No., Job No, etc.
3. Wcat "siviKid by Boston Edison Co Type Code Symbol Stamp N/A Nme h*harivadon No. N/A 600 Rocky Hill Road. Plymouth. MA 02360 Expiration Date N/A Merena
4. IdentificationofSystem Main Steam
5. (a) Applicable Construction Code ASM"III 193.L _Editice R 1970 AAA*ada Code Case (b) Applicable Edition of Section XI Utilized for Repaxrs or Rep 1-ta 19 12
6. Identification of Components Repaired or Replaced and Rept=-nt Components I

National Repaired, ASME Name of Name of Manufactum Board Other Year Replaced, or Code Canponed Mannunt Serial No. No. Identification Built Rep!-t Stamped (Yes or No)

SRV Target Rock 117 Main Stage 1968 Replace Yes RV-203-3C (SRV) /[ m r-Ger Atw.#) 9

7. Description of Work Reolace nuts.
s. Test cwe Hydrostatic 0 Pneumatic 0 Nnmmal Operating Pressure O Other O Pressure esi Test Temp. 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/83) This form (E00030) may be obtamed fan the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017

FORM NIS-2 (Back)

9. Remarks Four body to base nuts reol=M with TarEet Rock snares sunolied by BcCo.

Apphc w. u-rru mv. p.t. Repans to be an. dad CERTIFICATE OF COMPIJANCE We certify that the =f =tements made in the report are correct and this \ confams to the rules of the ASME Code, Section XL npair I Type Code Symbol Stamp b b Certificate ofAuthonzation No. b Expiration Date Signed '/s# - /rt 72f/ Date M.s .1997' Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commiazion issued by the National Board of Boiler and Preasure Vessel Inspectors and the State of Man and employed by Arkwri2ht Mutual Ins. Co. of Waltham. Mass. have inspected the =npnaents described in this Owners Reports during the period 4 e PS'lo 1-M- f 7 . and state that to the best of my knowledge and belief, the Owne has performed nommations e,nd taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signag this certificate neither the Inspection nor his employer makes any warranty, expsissed or implied, concerning the naminations and arrective measures describedin this Owner's Report. Furthermore, neither the Inspector nor his emplo)w shall be liable in any man wr for any personal injury or property <tamage or a loss of any kind ansmg frtun or e- d with this inspection.

((A- C M =* ions MA.1420 De y .- 2. 1997 (1v82) ,

I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Date 4/11/95

1. Owner Boston Edison Co Hans 800 Boylston Street. Boston MA Sheet 1 of 1 Mdrena Pilgrim Nuclear Power Station Unit 1
2. Plant Naam 600 Rocky Hill Road. Plymouth. MA 02360 MR 19501162 Espair Organiaauco P.O. No, Job No, sac.

Mdme Type Code Symbol Stamp N/A

3. Work Performed by Boston EA% Co N*"" Authernation No. N/A Expirstion Date N/A 600 Rocky Hill Road. Plymouth.MA 02360 Mons
4. Identification of System Feedwater Edition, Addenda, Code Case
5. (2) Applicable Constmetion Code _. ANSIB 31.1 19 67 (b) Applicable Edition of Section XI Utilized for Repers or Replacements 19_.,12
6. Identi5 cation of Components Repaned or Replaced and Replacement Components i Repared, ASME National Other Year Replaced, or Code Name of Manufacturer Board Name of Built Replacement Stamped SerialNo. No. Identification C a panent M =him (Yes or No)

R 9=ii No H6-1-SS2A Snubber No Bolt with stud Rn!"

7. Dricription of Work Modifv H61 SS2A per FRN 95-01-25 & 30.
8. Test C=W Hydmstatic 0 Pneumatic 0 Netut Operatmg Pressure O Other 0 Pressure vai TestTemp. 'F Visual ofWelds NOTE: Supplemental abeets in fonn of lists, sketches, or drawmgs may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items I through 6 ce this report is included on each abeet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82)

^

FORM NIS 2 (Back)

9. Remarks Applicable ManufusurW D.ta R.,~. to be a*1 ached CERTIFICATE OF COMPIJANCE We certify that the s'=tement< made in the report are correct and this conforms to the rules of the ASME Code,Section XI. npek Type Code Sytr.bol Stamp N Certificate ofAuthorization No. Expiration Date

[

Signed r/A. d-*-- Mn TA I Date 4/3 .197 7 OwnTr or Owners Desig:(de, Title CERTIFICATE OF INSERVICE INSPECITON 1, the undcraigned, holding a valid commmion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of _ Mass and employed by Arkwrinht Mutual Ins. Co. of Wahham Mass. have inspected the raamaaants described in this Owners Reports during the period t- $- 54 10 to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this "f->#- 97 . and state that Owners Report in accordance with the inism,csts of the ASME Code, Section XL By sigmng this certificate neitha the laspection nor his employer makes saf warranty, expressed or implied, raa-ia the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his emplowr shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or canaac'M with this mspectio:L Yb. ___c - leons MA-100 w - u.r ~ ~

o.t. /,- f- 19 M

/

(I M ,

~

a FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

=

Date_

3/11/97

1. Owner Bostm Edison Co Na=8 f I of 1 Sheet 800 Boylston Street. Boston MA A,u =

Unit i

2. Plant Pilnim Nuclear Power Station Name MR 19600461 600 Rocky Hill Road. Plymouth. MA 02360 Repair Orpam'- P.O. No., Job No., etc.

A44n Type Code Symbol Stamp N/A

3. Work Perfonned by Bwan Edison Co N/A Name Authoruatiu1No.

Expiration Date N/A 600RockyHillRoad. Plwnouth.MA 02360 Addams

4. Identification of System MO-1400 4 A. Core Soray. S.C.2 Addenda, Code Case Edition,
5. (a) Applicable Construction Code ANSI B31.1 19_67 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 82
6. Identification of Components Repaired or Replaced and Replacement Components I Repaired. ASME National Code Other Year Repinced, or Manufacturer Board Stamped Nameof Name of Built Reptamnent Serial No. No. Identification C&t Manufacturer (Yes or No) 1970 Replace No Valve Bolting MO 1400-4A
7. Desaiption of Work Reelace t--..rt boltina
8. Test C+w HydrostatzO Pneumauc 0 NommalOperatingPressure O psi TestTemp. 'F Omer O Pressure NOTE: Supplemental sheets in fans of lists, sketches, or drawings may be used. pnmded (1) i size is 8% in. x tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the numbe recorded at the top of this form.

l This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.

(12/82)

l FORM NIS-2 (Back)

9. Remarks Baltina renlaced Appheam M-FM Data Rapons 2 be awaimt I

l l

i i 4

CERTIFICATE OF Ces " iNCE We certify that the tatementa made in the seport are correct anc. _ cor. forms to the rules of the ASME Code,Section XI. repair Type Code Symbol S*. amp b A Certificate ofAuthoruation No. 6 Expiration Date Signed az[/m M 7~41/ _ . . Date 4[3 s 19 9 / _ l Owner er Owner's Desigfdee, Title l CERTIFICATE OF INSERVICE INSPECTION i

I, the undermgned, holding a valid tr=n=nsion issued by the National Board of Boiler and Pressure Vessel insp-4ars and the State of _%r:s and employed by Arkwnsht Mutua11ns. Co. of Walth== Mass. have inspected the m'a described i

in this owner's Reports duziug ti.e period 4 97to _ "?-.2 8 -9 7 . and state that to the best of my knowledge end belief, the Owner has performed exa=Mtions and taken corrective measures described in this Owner's Report in wh with the rec .ments of the ASME Code,Section XI.

By signing this certificate'nerther the Inspection nor his employer makes any wananty, d w or implied, -ia the ernminane andcorrective measures describedinthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any unanner for any personal injury or property damage or a loss of any kind ansmg f. m or rwwweai with this 4 inspection.

    1. Ujd A Commissions MA-1420

^

/r /paraame =0 ==--

o f e i,77 (12/82)

J k

e

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Prwisions of the ASME Code Section XI haa FAiaan Co Date 5/16/97

1. Owner Ness 800 Bov1=taa Street. Man MA Sheet 1 of 1 Adams:

Pdmm N-ta- Power *= s dan Unit 1

3. Plant Nams 600 D~h Hill Road. Plvrpouth.MA 02360 MR 19600412 & 19600811 Reper C _ - P.O. No., Job Ni.., .s.

Addes.

3. WorkPerfonnedby naa'an FAi- Co and . Type Code Symbol Stamp N/A Authortzation No. N/A W'alAiam SarneesInc Expustion Date J/A Addess
4. IdentificatumofSystem Core Sorav. RHR. C=+aia'aaat e
5. (a) Apphenble Construction Code ASME III 19.21 Editice, 7a R- AAA-ada Code Case (b) Applicable Edition of Section XI Utilized for Repaus or Replacernents 19 ,82
6. Identi5 cation of Components Repaired or Replaced and Replacement Components l

National Repened, ASME Name of Manufacturer Board ed.1 Year Replaced, or Code Name of SerialNo. No. Identification Built Replacement Stamped j C-m' M -a h cr Uma 4 No)

Torus CB&l O 1403 Penetration Repaued No X-212 Torus CB&I O 1403 Penetration Repared No X-214 Torus CB&l O1403 Penetration Repared No X-215 Torus CBM O103 Penetration Repared No l X-218 i

7. Descnptaca ofWork laa'alia'iaa of straiaa s remured torus na=1* raadifiem6an by w1Aiaa
8. ' lea ra=Aarnad Hyd ostatic 0 Pneumatic El Nomma!Operatmg Pressme O Other 0 Pressee esi Test Temp. 'F

NOTE. Supplemental sheets in form of lists, sketches, or drawings may be used, prended (1) size is 8% in. x 11 s., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/B2) This fann (E00030) may be o'.1 tamed from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017

  • Code Edition per NUREO-0661 and MK 1 containrnent program.

Ongmal construction code is ASME III Class B 1%5 edition through June 9,1%7 Addenda

l

! FORM NIS-2 (Back)

9. Remarks Pat ~ to MR 19600812. MR 19600811. =ad PDC 96-32. RT --==ia=+ian af wr.lds; w im- a Apphcable Manufamwe's Dasa Rapons to be saaded i

l l

l CERTIFICATE OF COMPIJANCE We certify that the =*=*====*= made in the report are correct and this ~ confonns to the rules of the AFME Code,Sectaan XI. nymire(

Type Code Symbol Stamp ,4 1

Certdicate of Autharvation No. k E ; =-C-:= Date Signed bP uU Owner or Owna's Designee, Title TW Date O 3' .1997 j

l

[ CERTIFICATE OF INSERVICE INSPECTION 1, the undr< maned, holding a valid comn innion issued by the National Board of Boiler and Pressure Vessel la=partars and the State of Maas . and employed by Arkwnght Mutual Ins Co. of Waltham. Mass. have inspected the componerits described in this Owner's Reports during the period I ,r-feto T- A.9- 9 7 . and state that to the best of my knowledge and belief, the Owner has perfc:med ===iM* ions and taken corrective measures desenhuiin this Owner's Report in accordance with the i - = of the ASME Code,Section XI.

l By manic'nis - certdicate neither the Inspection nor his employer = den any warranty, expressed or imphed, concernag the

! ===iaations atdkeective mamanes describedin this Owner's Report. Furthennere, neither the lampartar nor his employer I

shall be liable in a4 a.anner for any personal iqiury or property damage or a loss of any kind ansing from er aaaaartad with this P" / , . Cammi== ions MA-1420 V' Sagssame Nanent Benni, Stas, Provinos, and Endorsummes o o r- i,w -

l (12/82) , l l

1 1

b t

i f

i

}

)

i

i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1

Date 10/22/96

1. Owner haa FAiaan Co h as 800 Boylston Street _ han MA Sheet I of 1 Md'  !

Piladm Net-Power Station Unit 1 I

2. Plant h as MR 19600807 600 mach Hill Pand Piv=~*h MA 02360 Rapeir e . - P.O. No Jeb No., sec.

Messes Type Code Symbol Stamp N/A

3. Work Pen'anned by __ Ea='an Edison Co N"' Authanzation No. N/A E+1 ration Date N/A ,

600 mach Hill Ror.d. Pivmadh MA 02360 Means 4, FA-aeir. eiaa of s e u.ina- - E-; ;;

19_BQ _ Edition, 22 Add-aA- Code Case

5. (a) Apphenble Construction Code AmR m (b) Appbcable Edition of Section XI Utahzed for Repairs or Rept-ts 19_,32 -
6. Identification of Components Repaired or Replaced and Replacement Components I Repaired, ASME National Other Year Replaced,or Code Name of Hame of Mantscher Board No. Identification Built R=1=<=aat Stamped omt Manufacturer SerialNo.

(Yes or No)

MSIV Atwood & AO.203-2C 1982 RW Yes Morrill

/peirs ru

~

/In?M#9) d

7. DesenptionofWork P 17 . -- -- --nhiv.
8. TestConducted. Hydrostatic 0 Pneumatic 0 NommalOperstmgPressee E Othe. O Pressure osi TestTemp. 'F NOTE: Supplemutal sheets in form of lists. ***rhes, or drewms: may be used, pnmded (1) size is 8% in. x 1I in., (2) informa-tion in items 1 G.'mgh 6 on this report is inchded on each sheet, and (3) each sheet is numbered and the nwnber of sheets is recorded at the top of this fann.

(12/82) This form (E00030) may be obtamed from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

. ~ . - . - . . -. . . .. - .. --- -

l 1

FORM NIS-2 (Back)

9. Renvns Renlace noonet ****mbly with new **aamhly aimaliaA by Atwood & Morrill. Daa1*~d =Mae with 13g

^7 " Manufammers % Reputs to be saadud style. cut ug' goced adine leak off-line l

l l CERTIFICATE OF COMPLIANCE We certify that the *=taman'a made in the report are correc'. and this -

conforms to the rules of the ASME Code,Section XI. repair er C*- '4 l

V Type Code Symbol Stamp A Cert Scate ofAuthonzation No. 4 Expiration Date Signed Al/w 74/ Date M3 .199 7 l " OwneTor Owner's Designee, Title I, the undersigned, holding a valid comnussion issued by the National Board of Boiler and Pressure Vessel s ' 46 and the State

! of Mass and employed by Arkwrinht Mntual Ins. Co. of Walth== Mass. have inspected the cornpanents described in this Owner's Reports durir.c the period 4-r-9fto 1-M-9 7 . and state that to the best of my bc.d ," e and belief, the Owner has performed exammations and taken corrective measures dedbed in thi l Owner's Report in accordance with the requirements of the ASME Code, Secdon XI.

j By sigmng this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, concermag the j erarninations andcorrective measuresdescribedinthis Owner's Report. Furthermore, neither the inepartar nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ansing fmm or connected with this 1

'"'I"ia" bfJAM - C-.mions MA-100 m

yy ,-e c-r- t,97

,, --~

i (12/82) l u

1 i

l i

l

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Dad = Fdiaaa Co Date 5/14/96

1. Owner Naas 800 M ^ -- Street Rad = MA Sheet I of 1 Addrum Pilmm F~t- Power S*=*i- Unit i
2. Plant Nems 600 Rocky Hill Paad Pivraaneh. MA 02360 MR 19601061 Rapeir C P.O. No Job No., anc.

Addrums Da='= Fdi- Co Type Code SymbolStamp N/A

3. Work Perfanned by Authorusbon No. N/A F-aiatiaa Date N/A 600 Paeh Hill Paad Plvraanth MA 02360 "

Addrums

4. tdentificatum of System _ Main ** - ---- * .r x 19Dtion, Addanda, Code Case
5. (a) Apphable Construction Code ANFIII (b) Appbceble Edition of Section XIUtilized for Repairs or R-f-ts 19 82
6. Identification of C - -; = - = Repaired or Replaced and Replacement Components i

National Repaared, ASME Manufacturer Board Other Year Replaced,or Code Name of Name of Serial No. No. Identifation Built F=; lac ==nant Stamped C~-aaaaat Manufacturer (Yes or No)

SRV Pilot Target Rock RV-203-3C RgM==t Yes Main Staae l >

l l

l l

7. Deswiption of Work lad =H snare SRV nilot
8. Test Candacead HydrostaticD Iwan w 0 Narn=a10perstagnessure O l

Other 0 Pressure nei TestTemp. 'F NOTE: SRV set pressures are calibrated by the vendo per Tech. Spec., no additional testag is required.

NO1Y.: Supplemental sheets in form of lists, Astches, or drawings may be used, provided (1) size is 8% in. x 11 is., (2) informs.

tion in items I through 6 en this report is ivhdod on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) " Ibis form (E00030) may be obtamed from the Order Dept., ASME,545 E. 47th St., New York, N.Y. 10017 l

l

FORM NIS-2 (Back)

9. Remarks Apphcaba. M-e% twa asports to to ansched I

i CERTIFICATE OF COMPIJANCE i We certify that the s'a**= ente made in the report are cortect and this _

conforms to the rules of the ASME Code, Section XL '

. apeir ^

V Type Code Symbol Stamp 4

  • l Certificate ofAuthanzation No. b d Expiration Date Signed ,[ [/w Date (/3 .1997
Owner or Owners Designec, Title l l

CERTIFICATE OF INSERVICE INSPECTION I, the underW bolding a valid commission issued by the National Board of Boiler and Pressure VesselInspectors and the State of __ Mass and employed by Arkwnsht Mutual Ins. Co. of Waltham. Mass. have inspected the components described j in this Owners Reports during the period 4 - f- 9f"to g-J24'-9 '7 . and state that j to the best of my knowledge and belief, the Owner has performed exammatiots and take' ncortdctive tnessures described in this Owner's Report in accordance with the ig-awts of the ASME Code,Section XI.

By signing this certificate neither the Inspection nor his employer makes any warranty, expressed or implied, ceiaomg the j

evaminations and corrective measures describedin this Owner's Report. Fmtttrmore, neither the Inspector nor his employer

shall be liable in any manner for any personal injury or property damage or a loss of any kind arismg froan or ennnected witn this inspectient 1 .

t .- C - ia= ions MA-1420 National Board, same, Preece, and Eadanerases f / Inspecaer'sFirsaure

o I t-9--i,M -

1 (12/82) ,

  • I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Regnimi by the Previsions of the ASME Code Section XI Date 2/24/97
1. Owner Bw= FAiaaa Co mais 800 Boylston Street. Bwaa MA Sheet i of 1 Add w Pilarim N_v!__e Power Station Unit 1
2. Plant mm.

600 Rocky Hill Road. Plvmouth. MA 02360 MR P9401325 i Adammi Repair orsenaation P.O. N., Job No., etc.

Bwan FAi- Co Type Code SymbolStamp N/A

3. Work Perfanned by

""' Authorirahan No. N/A 600 Rocky Hill Road. Plvra-th MA 02360 Expiration Date N/A a Addess

4. Identificatice of System F ==idn=1 Heat Removal l

USAS

5. (a) ApplicaNeConstructionCode ANSIB31.1 19.52 Edition, AAAanAm Na N.10 Code Case (b) ApplicaNe Edition of Section XIUtilized for Repairs or R;!~ents 19 12
6. Idennfication of Components Repaired or Replaced and Replacement Components I National Repaired, ASME Name of M d--+=cr Board Other Year Replaced,or Code Name of C - aaaaat Manufacturer Serial No. No. Identification Built Replacement Stamped (Yes or No)

RHR LPCI Rockwell N277SP66, 1%9 Replace 1nternals NO Injection Edward Valves - - M3ZS-18" Check Valve Inc 100168B

7. DescriptionofWork P-1 7 sc. di hiame eins. and b=hi~$ an l seat ocr FRN 97 01-4].
8. Test C*-d- Hydrostatic 0 Pneumatic 0 NommalOperatingPressure O Other O Pressure osi TestTemp. *F l

NOTE Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in itesns I through 6 on this rv.part is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtamed $ rom the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017 l .

I l

\

I l

-. . --- . =- . . . - - -. .. - - . - _. .. --

4 a

  • l j frORM NIS-2 (Back)
9. Remarks Refer to FRN 97-01-41 for ASME C~ia Rar* ion XI inalt to rentir/r=Ia== ant olan.

i Appbcable MaWN Data Rapons to be enached i

J CERTIFICATE OF COMPIJANCE We catfy that the =*=*ananta made in the report are correct and this conforms to the rules of the  !

ASME Code, Sectace XI. espear l

1 Type Code Symbol Stamp b A-Certificate ofAutheruation No. U 8 Expiration Date Signed fl.tl A : " h TA V Date 6/3 .1997 Owner or Owners M% Title CERTIFICATE OF INSERVICE INSPECTION I, the underegned, holding a valid a= mission issued by the National Board of Boiler and Pressure Vessel I.,.ps and the State cf Mans and employed by Arkwriaht Mutual Ins. Co of Wal'h*= Mass. hsve inspected the components described 1 in this Owner's Reports during the pmod 4- S- 9f to T-# f- 9 *7 . and state tnat to the best of my knowledge and belief, the Owner has perfened evenunatirma and taken corrective measures described in this i Owner's Report in accordance with the .+ of the ASME Code,Section XI.

By signing this certdicata neither the Piaa_ nor his emplopt makes any warranty, expremed or implied, concermng the avaminations andcorrective measuresdescribedinthis Owner's Report. Fmi;.sg.ws, neither the Inspector nor his employer shall be liable in any mannar for any personal injury or property damage or a loss of any kind anang from or raaaarend with this inspectiert p

f [x .

A/

c-missions MA-1420

-~a-o t-r- ,,9 7 ...

(12/82) ,

_ _ _ . _. _. ~ _ .

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Date 2/14/97

1. Owner Bwan Edison Co Nam 800 Boylston Street. Bwnn MA Sheet i of I Addrum Pilmrim Nuclear Power S'adaa Unit 1
2. Plant Naan 600 Rocky Hill Road. Plymouth. MA 02360 MR 1960065I Rapan C.. - "- P.O. No., Job No., anc.

Addnes Type Code SymbolStamp N/A

3. Work Perfanned by Boston Edison Co

""" Authanzation No. N/A m 600 Rocky HillRoad. Plvmanth MA 02360 Expiration Date N/A Addrom

4. Identification ofSystem Hinh P we N1=nt Iniection 19.67 Edition, Addenda, _ Code Case
5. (a) Applicable Construction Code ANSIB31.1 1

(b) Applicable Edition of Section XI Utilized for Repairs or RT -ts 19_.82

6. Identification of Components Repatted or Replaced and Raale<=ent Components I

National Repaired, ASME Board Other Year Replaced, or Code Name of Name of Manufacturer No. Identification Built Rapta~= ant Stamped cet Manufacturer SerialNo.

(Yes or No) 201 Replaced No Snubber BerBen. -

SS43-20 40 Patenon -

478 Replacement No Snubber Anchor /

SS-23-20 40 Lvyns,

7. Descriptice of Work Rcacyc and rectace snubber IAW MR 19600651 work instruction and w d. c 3.M 4-89.
8. TestCWM Hydrostatic 0 Pneumatic 0 NommalOperstmgPressure 0
  • Other O Pressure psi TestTemp. 'F

< Pst- Vr NOTE. Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% ir x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/E2) This form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ' - - - - ~

FORM NIS-2 (Back)

9. Remarks Applicableu==>-- d. Data Reports to be anadwd CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are corr ct and this ASME Code, Section XL ' conforms to the tries of the npair er ^ -

Type Code Symbol Stamp N Certificate ofAuthenzation No. O M Exptration Dede Signed /m I MV Date 3 .1997 OwnerorOwnersDesudee Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commierion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of _Jdag_ and employed by Arkwright Mutual Ins. Co. of Walthem Mass. have inspe:ted the components described in this Owner's Reports during the period t- <- Peto 7 ,21-9'7 . and state that to the best of my krowledge and belief, the Owner has pen cmed exammations and taken corrective measures described in this Owners Report in accadance with the iwaats of the ASME Code, Section XL By signing this certificate neither the Inspection nor his employer makes any warranty, @M or implitx1, concermng the examinations andcorrective measuresdescribedinthis Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any mane for any personal injury or property damage or a loss of any kind ansmg from or conneciert wA this mspection.

IW y .- C.- - M.-

o.a 4 199 9 _

(12/82) ,

FORM NIS-2 OWNER'S REI ORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Date 2/17/97

1. Owner B^ dan FAi=an Co Name 800 Boylston Street. Bastan MA Sheet I of_ 1 Marus Pilarun Ni_v1= Power Statinn Unit 1
2. Plant Name 600 Rocky Hill Road. Plvn=<th MA 02360 hG1196()0646 Mense Repr Orgamunes P.O. No., Job No., etc.

Badaa F^aariCo Type Code SymbolStamp N/A

3. Work Perfanned by

""" AuthonzationNo. N/A 600 Rocky Hill' Road. Plymouth. MA 02360 Expuntion Date N/A Marus l 4. Identification ofSystem Core Sorav 19.fLEdition, Addenda, Code Case

5. (a) Applicable Construction Code USAS B31.1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_.8.2
6. Identification of Components Repatrixi or Replaced and Replacement Components National Repaned, ASME Manufecturer Board Other Year Replaced,or Code Name of Name of Carapawt Manufacturer Serial No. No. Identification Built Re! - t Stamped (Yes or No)

Snubber Anchor / 450 Replaced No SS-14 3-04 Darling Snubber Anchor / 482 Rep 1= ment No SS-14-344 Darling l

l

7. Description of Work Remove and reolace anubber IAW ME 19600646 work instruction and Lidiuc 3.M.4-89.
8. TestCa~hM HydrostaticO Pneumatic 0 NommalOperatingPressure 0
  • Other O Pressure esi TestTemp. 'F
    • fir- VT NOTE: Supplemental slyxts in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 1I in., (2) informa-tion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obtamed from the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017 l

l i

i

. .._ ._ .. _ . _. _ . . .. m._._______ _ _ _ _ _ . . _ . . _ . _ _ _ . _ _ _ . . - . . . _ _ . _ _ . . _ _ . _

f l

l l

t FORM NIS-2 (Back)

9. Remarks Appbcable ManufachaWs Desa Rapons to be amashed I

l l

CERTIFICATE OF COMPflANCE l We certify that the =*=8-h made in the report are correct and this conforms to the rules of the ASME Code, Section XL repair Type Code Symbol Stamp N .A CertiScate ofAutheraation No. N A ppa Date _

Signed 2N - - M 7X Y Date h .1997 Owner or Owner's R . Title CERTIFICATE OF INSERVICE INSPECTION I, the ui.f.sM holding a valid ev=nmiadan issued by the National Board of Boiler and Presswe Vasel Inag=*a : and the State of Mass and employed by Arkwnsht M*at Ins. Co. of Wal* ham Ma== have inspected the componesits described in this Owner's Reports during the period 4 95 to 7 - 2 f- 9 7 . and state that to the best of my knowledge and belief, the Owner has performed mammatiana and taken corrective menswee described in this Ownes's Report in accordance with the .y w of the ASME Code, Section XL By signing this certi6cate neither the Inspection nor his employer makes any warranty, expressed or imphed, concermag the

===in=*=== and corrective measures described in this Owner's Report. Furthermore, neither the laq= tar nor his employer shall be liable in any manner for any personal igjury or property damage or a loss of any kind anang from or -M with this M. nnnmi , s MA-1420 g p l n., - ~ -

osa t-f- ts*77

12/t2) ,

l 4

i i

4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI l

J beaa FAi- co Date 2/14/97

1. Owner Nses I

Sheet I of 1 800 Bovid = Street. bdaa MA 4

Mdes 1 Pilarim N Power **diaa Unit I

2. Plant mm.

600DackyHillPaart Plmdh MA 02360 MR 19600650 aspairc. - P.O. W., Job %., sec.

udass ,

3. Work Performed by bd- FAi- Co TypeCodeSymbolStamp_ N/A
  • "* AuthanzataanNo. N/A Expiration Date N/A 600 DacivHillRani Plmdh MA 02360 Menus
4. IdentiScshen of Syc Hiah n- #=' ' fai"i=

19 J2J,dition, Aman <t= Code Case

5. (n) ApphcableConstructaceCode ANSIB31.1 (b) Appbcable Edition of Section XI Utahand for Repairs or Rep 1==nanen 19J
6. Identination of Components Repaired or Replaced and Reptamment Compone.rs I National Repaared, ASME Manufacturer Board Other Year Pii d. or Code Name of Name of No. Identification Built Replacement Stamped C-t Manufar*ner SerialNo.

(Yes or No)

Snubber Bergen- 200 RW No SS-23-20 41 Paterson Snubber Anchor / 479 P T = --- t 1

No SS-23-2041 Durhns l

l i  ;

! 7. Desenphon ofWork D- y and r=1= -hhar IAW MR 19600650 work instrnetian and w= '

  • 3.M.4-89.

I

. Test can,InetM Hydrostatic 0 Pneumshc 0 N=nmalOperstagPressure O

'Other O Pressure asi TestTemp. 'F

" T S C- v'T NOTE: Surgdemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion 12 items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/82) This form (E00030) may be obeamarl from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017 I

l i

(

l l

9 FORM NIS-2 (Back)

9. Remarks Appbombie Ma.ufam.are Data Rapons a he anaded CERTIFICATE OF COMPIJANCE We omrtify that the statements made in the report me correct and this conforms to the ndes of the ASME Code, Section XL suyair Type Code Synbol Stamp L1l A ,

Certificate ofAuthorizaban No. O v1. NW6 Date Signed 9 -I TAV Date M3 .19T7 Owner or Ownsh 6esignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid - -- . issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Maan and employed by Arkwnsht MutualIns. Co. of Waltham. Mass have inspected the cr==iv-nts described in this Ownsh Reports during the period t- <- 95 to .7-J 9-9 7 . ed state that to the best of my knowledge and belief, the Owner has puformed -*= and taken conective measures described in &

Owns'sReportinaccordancewiththe.4 ^ ofthe ASMECode,SechonXL By mening this cert:5cate neither the inagwr+ia= nor his employer makes any wanenty, supressed or imphed, concerning the

--ni==tiana and corrective sneasures described in this' Owner's Report. Furthennare, neither the Inspectar nor his employer shall be liable in any manner for any personalindury or property damage or a loss of any kind arimag tem er aannared with this in.p.ctian MM- r % , ane MA-1420 Dese fy pd-f-t997 ,

(12/B2)

W., - - , - .~e, . - . . - -. , ,,. . - . . _ , , . . . . , ,. . , , . ,,,. . _ , , , . , - , , _ .

l 1

\

i l

1 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI j w a=Ndi- co Date 2/17/97

l. Owner Name l

800 a" .9= StreeLh- MA Sheet I of ,1 i Amuss

2. Plant PiirimN ta -Power R'a'iaa Unit 1 1

Nems 600 D~Irv Hill Da=A Piv=~4 i1A 02360 MR 19600649 Address Rapere. ,

P.O. No., Job No., ses.

3. Work Perfanned by Da-'- Ndi- Cs Type Code SymbolStamp - N/A

" Authorizaban No. N/A 600 Darkv Hill na.A piv--et, MA 02360 . Expiration Date N/A Andress

4. IA-*irwahan of sp n. :a. I Hamt n====aval
5. (2) Apphceble Construction Code ANSIB31.1 19.62_ Edition, . Add-da CodeCase -

(6) Appbcable Edition of Sechen XI Utahand for Repsars or PT-ts 19_,.H t

6. Man **c=*ma of Cc =i-- 2 Repared or Replaced and Replamneat Ce= ;-

i National Repavat. ASME Name of Name of Manufacturer Board Other Year PT d.or Code C- ---' Maanfar*=er Serial No. No. Identi6 cation Built Replanaraant Stanped (Yes or No)

Snubber Anchor / 464 Replaced No SS-10 343 Derhna Snubber Anchor / 481 P f ar====' No 8S 10-3 43 Durhaa 7 Deseptaen of Work Da= ave and >= 8- =li6 IAW MR 19600649 work * - t---x= and e = "

3M4-89.

s. Test r'h HMO P--*- 0 NanunalOperating Pmsure O Oamr O Pressure nei TestTemp. *F
  • Preservice functional test, preservice visual exammation NOTE. Supplemental sheets in form of lists, akasew, or drewmas inny be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in imms 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the wp of this form.

(12/82) This form (E00030) may be obtamed from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

)

ek

- ~' e v -w--- .-,

- . ~ - . - - . - - . - - _ . - ~ . . . - - _ . . _ . - _ . - - . . . . . - - . . . - . - .

e...-.-.-.

1 i

j FORM NIS-2 (Back) 1

} 9. Remarks

j. Appbcable Masudbremer% Lata Rapons to be sneaked i

i I

t .

1.

CERTDPICATE OF COMPIJANCE l l We cenify that the statements mande in the report are correct and this coaforms to the rules of the I supeirer C j- ASME Code,Section XL -

7 l Type Code SynabolStamp d i .,

3 l Cad 6cate ofAuthorization No. d A FYA Date  ;

j Signed lH- lct AV Date 6/9

.1997 I

Owner or Owner 4 M . Title I l 1

l i CERTIFICATE OF INSERVICE INSPECTION /

l I,the-- ' ; ", holdag a valid c==ai== ion issued by the National Board of Boiler and Pressure Vessel lespectors and the State j of Mass and employed by Arkwrisht Mutual Ins. Co. of Waltham. Mass. have inspected the comparents deswibed j in this Owaats Reposts dunas the period _ g- r.-9fto 's-M 'l7 . and state that to the best of my knowledge and belief, the Cwner has performed -=*== and taken correctim mensues deswibed in ibis Owners Report in accordance with the reqmroments of the ASME Code, Section XL i By agning this omtaficase neithm the Inspection nor his employer makes any warranty, expressed or imphed, noneaning tM i -ia=*== and cornetiw mensmes describedin this Owners Report. ' Furthermore, neither the1==p=*ar nor his unplayw j shall be liable in any meaner for any personal iqiury or property danage or a Ices of any kind anang from er connedad with this

W I M" Canuntamens MA-1420 Duas r pI 1997 -

(12/82) .

4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Ba='an FAi== Co Date 2/17/97 Namm 800 Boviston Street. Boston MA Sheet 1 of 1 Manae
2. Plant Pilarim Nurta=e Power Lation Unit 1 Naam 600 Rocky Hill Road. Plymouth. MA 02360 MR 19600645 Adenas Rapeir C. - - P.O. No Job No., etc.
3. Work Perfonned by Boston Edison Co Type Code SymbolStamp N/A Num Authorization No. N/A 600 Rocky Hill Road. Plvmouth. MA 02360 Expiration Date N/A Menen
4. Identification of System RWAnal Heat Removal
5. (:) Applicabic Construction Code .. ANSJ B31.1 19.fi2_ Edition, Aha Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacementi 19_.3.2 s
6. Menhfication of Components Pgaired or Replaced and Raph-nt Components I National Repaired, ASME Name of Name of Manufacturer Board Other Year Replaced, or Code c ye y==uwer Serial No. No. Identification Built Ra,n!=e-maat Stamped (Yes or No)

Snubber Anchor / 455 Replaced No SS-10 3041 Darling Snubber Anchor / 480 Replacement No SS-10 3041 Durhna

7. Desenption of Work Remove and reolace snubber IAW MR 19600645 work instnaction and Lawdm 3.M 4 89.

l

8. Test C*H_: Hydmstatic0 Pneumatic 0 NommalOperstmgPmsure O l Other O Pmsure ,, j Test Te:np. 'F
  • Preservice functional test, purvire visual exanunation Norm: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x !I in., (2) informa-tion in items I through 6 on this rept is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

l (12/82) This form (E00030) may be obtained fran the Order Dept., ASME,345 E. 47th St., New York, N.Y. 10017 l

l 1

_ _ _ _ _ _ . . . _ _ _ . . . _ _ _ _ _ _ _ . _ _ _ _ . . . _ . . . _ _ . _ _ _ . _ . _ . _ . . _ . _ . _ - . _ . . _ _ _ _ . . . . ~ _

l t O 4 ,

i I

i

! FORM NIS-2 (Back) i

, 9. Remarks j Appin bi. u_% on. aspons se k an=sted 1

2 CER11FICATE OF COMPLIANG We certify that the s*=8-an'= made in the report are acrrect and this m confonns to the rules of the ASME Code,Section XL - nymir 5 Type Code SymbolStamp N Catscate ofAuthanamen No. N A ExprobonDate '

S& n h *fAV Date W3

.1997 Ominar or Owner'sn-%aa. Title J

CERTIFICATE OF INSERVICE INSPECTION 1, the =="= 'M. holdag a valid ====== ion issued by the Nahanal Board of Bouer and Presame Vessel In= par'ars and the State

  • of u- and employed by Arkwnsht Mutual Ins. Co. of Waltham. Mass. have inspected the =npanant, described in this Osmar% Reports during the periM 4-r- kto 4-Ef- 9 7 . and state that to the best of my knowledge and belief, the Owner has perfonned v===== == and taken corrective measures described in this owner's Report in accontence with the reqmraments of the ASME Code, Sectuu XI.

By sismas this certmoete neither the % nor his employer makes any warranty, expressed or imphed, concernas the cr-iam'== and corrective measures described in this Owner's Report Furthennare, neither the Inspecter nor his employer siell be liable in any asaner for any personal hinry or property damage x <t loss of any kind ariang from er cranected with this irspechen.

Me can=ni-aos MA-M20 Esas [ - T - 19 N ,

(12/82) ,

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

i. O wnse = =.- se - c. D.te sa m7 Name 300 Bov'=*aa Street. b=*aa MA Sheet I of 1 Menes
2. Plant Pilarim N Power R*=*6 Unit 1 Nams 600 Dadev Hill D-A Plvmouth. MA 02360 MR - '

1931461 Mdnus Rapsire_ , - P.O. N% Ash Ns, sec.

3. Work Perfenned by b=*= FA- Co Type Code SymbolStamp N/A Nas Authonzaban No. N/A 600 DaAev Hill Da-A Plvwk MA nitAn F-a3*=*ia=

Date N/A Addams

4. Id=hfie=han of System u a.:6 , %

19.IUklition, W1977 m-da Code Case

5. (:) Appbcable Construction Code Anw m (b) Applicable Edition of Sechan XI Utahand for Repairs or Darlan====** 19 12
6. IAanei&atian of C+- ;_r_ - = Repaired or Replaced and Reptars mant C==aa==a*=

l National ,

Repaired, ASME Name of Name of Manufacturer Board Other Yer, 1 Replaced, or Code CP Manufacturer SerialNo. No. Ident:6 cation Built ' r aa8 -

  • Stamped (Yesor No) l Pipe Clamp Bergen Peterson N/A N/A H.lo.1 sol 6 93 Ragdaa=nant N/A
7. Descnphen of Work D 8-~ bar fr-- with alaa at-
s. Test c=AM Hydrostanc0 P====*- 0 NummalOpadingPnasure C ,

Other O Pressure nei TestTemp. 'F NO'm: Supplemental sinents in fans of lists, =Ireerha, or drawings iney be vmd, provided (1) size is 8% in. x 11 in., (2) informa.

tion in itans 1 through 6 en this report is metadad on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fann. ,

(12/B2) This form (E00030) may be ah*=inad froen the Order Dept, ASME,345 E. 47th St, New York,' N.Y. 10017

. .. . . . . - . - - . . _.-.~ . - . _..-.- . - -. - . _ . - . - . . - - .. ....

O i

FORM NIS-2 (Back)

9. Remarks Pine ela'na nrocured to ASME III. = Man NF 1977 FAitian thraneh winter 1977 Addaada which Apphenhie Mandummers Data Reports to be amadud

==*i=fien niaine daien cada_ ANSI B31.1.1973. Refer to FRN 93-01.12. 34. 53. $$ and 56.

CERTIFICATE OF COMPIJANCE We certify that the arata=wata made in the report are correct and this .

confwas to the rules of the 3

ASME Code, Section XL repair -

Type Code Symbol Stamp b k Certificate of Authenzation No. d N- Expiration Date Signed ~ ] /w M 'DW Date 3 .1997 Dwner or Owner's M . Title ,

CERTIFICATE OF INSERVICE INSPECTION I, the unders.gned, holding a valid can===ian issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Mann and employed by Atkwright MutualIns. Co. of Waltham. Mass. have inspected the -p desaibed l in this Owner's Reports dunng the period / - 1. Pflo 3-Af- 9 7 . and state that l to the best of my knowledge and belief, the Owner has performed ==mmatinos and takes corrective measurse described in this Owner's Report in accordance with the ., of the ASME Code, Section XL l l

By sigmng this certt6cate neither the instwetion nor his employer makes any warranty, expressed or imphed, concernas the

==minatian, and corrective measures describedin this Ownse's Report. Furthermore, neither the Inspartar nor his employer -

shall be liable in any manner for any personalispury or property damage or a loss of any kind anang from or connected with this aspectiost M- Cammia=ces MA.1420

/ leyessort Sagassure Nahamal Beard, Buss, Primane, and Eadoreanumas Due

[4 19U (12/s2) 1

  • l i.

se - %w-,- w , - -