, (3 *~

March 23, 1988 Docket No. 50-344 DISTRIBUTION LDocket. File i DHagan Mr. David W. Cockfield NRC &~LPDRs EJordan Vice President, Nuclear . PDV Reading DMCrutchfield Portland General Electric Company < GMHolahan JLee 121 S.W. Salmon Street TChan OGC Portland, Oregon 97204 JPartlow TBarnhart (4/ Mkt)

Wanda JoAes EButcher

Dear Mr. Cockfield:

ACRS(10) GPA/PA ARM /LFMB REG V (4)

Subject:

Trojan: License Change Application (LCA) 154 (TAC No. 66096) 4 By letter dated August 6, 1987 as revised December 16, 1987, Portland General Electric Company (PGE) requested a revision to the Trojan Technical Specification (TS) to correct the Basis Section to TS 3/4.4.6.2.

Bases to the Technical Specifications are not considered to be part of the Technical Specifications. As such, request for NRC approval of proposed re-visions to the Bases which do not necessitate changes to the Technical Specifica-tions need not be submitted as an uendment to the Facility Operating License.

We have nevertheless reviewed your submittals and conclude that the proposed Basis regarding Pressure Boundary Leakage and the added requirement that the unit be brought to Cold Shutdown following the occurrence of Pressure Boundary Leakage are consistent with that of Westinghouse Standard Technical Specifi-cations (W-STS) and resolves an editorial inconsistency between B 3/4.4.6.2 and the definition of Pressure Boundary Leakage as defined in TS Section 1.16. Therefore,'we find the proposed Basis to be acceptable; your request for revision is granted.

The revised Basis is enclosed.

Sincerely, original signed by Harry Rood for George W. Knighton, Director Project Directorate III-V Division of Reactor Projects - III, IV and V and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

As stated cc: See next page 3 POV CRSP/PDV DRSP/D:PDV ,

mes TChan GKnighton 3/g/88 3//J /88 3 4 '88 l

$033S000dO!OS 4

, <s*

Mr. David W. Cockfield Portland General Electric Company Trojan Nuclear Plant cc:

Senior Resident Inspector U.S. Nuclear Regulatory Commission l Trojan Nuclear Plant Post Office Box 0 Raiaier, Oregon 97048 Mr. Michael J. Sykes, Chairman Board of County Commissioners Columbia County St. Helens, Oregon 97:

Mr. William T. $1xon Oregon Departmene of Energy Salem, Oregon 97310

' Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596