ML20148B918
| ML20148B918 | |
| Person / Time | |
|---|---|
| Site: | Zimmer |
| Issue date: | 09/14/1978 |
| From: | Heishman R NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Borgmann E CINCINNATI GAS & ELECTRIC CO. |
| Shared Package | |
| ML20148B922 | List: |
| References | |
| NUDOCS 7811010050 | |
| Download: ML20148B918 (2) | |
See also: IR 05000358/1978016
Text
hf
3
,
.
4,
UNlTED STATES
,
., q
f' 4
NUCLEAR REGULATORY COMMISSION
f ,. Z
h
REGloN til
799 ROOSEVELT ROAD
4
oLEN ELLYN, ILLINols 60137
,
.....
SEP 141978'
Docket No. 50-358
Cincinnati Cas and Electric
f
Company
ATTN:
Mr. Earl A. Borgmann
Vice President Engineering
139 East 4th Street
Cincinnati, OH
45201
Gentlemen:
This refers to the inspection conducted by Messrs. P. A. Barrett,
J. Hughes, G. F. Maxwell,'and T. E. Vandel, of this office on
August 2-4, 1978, of activities at the Wm. H. Zimmer Nuclear
Power Station authorized by NRC Construction Permit No. CPPR-88
and to the discussion of our findings with Messrs. B. K. Culver
and W. W. Schwiers, others of your staff, and others of the
Zimmer staff at the conclusion of the inspection.
The enclosed copy of our inspection report identifies areas
examined during the inspection. Within these areas, the
inspection consisted of a selective examination of procedures
and representative records, observations, and interviews with
personnel.
During this inspection, certain of your activities appeared to
be in noncompliance with NRC requirements, as described in the
enclosed Appendix A.
This notice is sent to you pursuant to the provisions of
Section 2.201 of the NRC's " Rules of Practice," Part 2, Title
10, Code of Federal Regulations.
Section 2.201 requires you to
submit to this office within thirty days of your receipt of
this notice a written statement or explanation in reply,
including for each item of noncompliance: (1) corrective
i
action taken and the results achieved; (2) corrective action
to be taken to avoid further noncompliance; and (3) the date
when full compliance will be achieved.
i
781101@ 60
-
. - - -
. - .
-- --
-
-
. -
- . . -
._
1
%
.
.
Cincinnati Gas and
-2-
]3{p 14 Jg7g'
Electric Company
In accordance with Section 2.790 of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of'this
letter, the enclosures, and your response to this letter will
be placed in the NRC's Public Document Room, except as follows.
If the enclosures contain information that you or your contractors
believe to be proprietary, you must apply in writing to this
office, within twenty days of your receipt of this letter, to
withhold such information from public disclosure.
The appli-
cation must include a full statement of the reasons for which
the information is considered proprietary, and should be pre-
pared so that proprietary information identified in the
application is contained in an enclosure to the application.
!
We will gladly discuss any questions you have concerning this
inspection.
Sincerely,
e}
a l.
'- /
.-
R. F. Heishman, Chief
Reactor Construction and
Engineering Support Branch
Enclosures:
1.
Appendix A, Notice
of Violation
2.
IE Inspection Rpt
No. 50-358/78-16
cc w/encls:
Mr. J. R. Schott, Plant
Superintendent
Central Files
'
ReproductionUnitNRC20b
l
MDR
Local PDR
'
U. Young Park, Power Siting
,
(
Commission
(
l
I
!
l
'
-
-
.
.-
-.
-
--.
-
..
- - ..
-
-
.