f

, fl,AR 2 1933 -

Docket Nos. 50-325 and 50-324 DISTRIBUTION 6 Doetet' Hoe 7t"^ 325/325 Mr. E. E. Utley NRC PDR EAdensam GPA/PA Senior Executive Vice President Local PDR PAnderson ARM /LFMB Power Supply and Engineering & Construction PD21 r/f BMozafari i

Carolina Power & Light Company TMurley ESylvester Post Office Box 1651 OCC-WF ACRS(10)

Raleigh, North Carolina 27602 FMiraglia EJordan CRossi JPartlow

Dear Mr. Utley:

SVarga TBarnhart(4) 4 Glainas J. Rajan

SUBJECT:

INSERVICE INSPECTION RELIEF REydEST NO. RR-8, REV. O. FUNCTIONAL TESTING 0F SNUBBERS - BRUNSWICK STEAM ELECTRIC PLANT (BSEP), UNITS 1 & 2 (TAC N05. 63786/63787)

By letter dated August 19, 1987, Carolina Power and Light Company (CP&L) sub-nitted additional infonnation to supplement a letter dated June 4,1987, concern-  :

ing the Inservice Inspection (ISI) Program for Brunswick Steam. Electric Plant, Units 1 & 2. Contained in the August 19, 1987 submittal was relief request '

RR-8 by which CP&L requested relief frcm certain Section XI ASME Code requirements related to the second 10-year intenval ISI program. The NRC staff has acted on relief request RR-8 as an individual action so it would not impact

  • the scope and duration of the current refueling outage.  ;

Based on our review and on information provided by CP&L during a telephone con-  !

ference on November 23, 1987, the NRC staff has provided an interpretation of  ;

Section XI of the ASME Boiler and Pressure Vessel Code in the enclosed Safety >

Evaluation (SE).

The SE supports the proposed testing plan for the functional testing of snubbers,  ;

The NRC staff has determined that the requested relief is not necessary because the proposed plan meetsSection XI of the ASME Code requirements and complies with the requirements of Technical Specification 4.7.5. l Sincerely. l Elinor Adensam. Director  !

Project Directorate 11-1  !

Division of Reactor Projects - I/II  ;

Enclosure:

3 As stated a

' LAf .tk R

l PE:PD21:DRPR g

PM:PD21:0 PR BC:EMEB: DEST C- .i DRPR PAnfferson BMozafari:aly ESylvester LMarsh E4densam 02gb/88 02/#/88 02/d/88 02/$A/88 0/ /88 g/y88 8803080108 880302 I

! PDR ADOCK 05000324 P PDR

e

Mr. E. E. Utley Brunswick Steam Electric Plant Carolina Power & Light Company Units 1 and 2 CC

Mr. P. W. Howe Mr. C. R. Dietz Vice President Plant General Manager Brunswick Nuclear Project Brunswick Nuclear Project Box 10429 Box 10429 Southport, North Carolina 28461 Southport, North Carolina 28461 Mr. R. E. Jones, General Counsel Mr. H. A. Cole Carolina Pcwer & Light Company Special Deputy Attorney General P. O. Box 1551 State of North Carolina Raleigh, North Carolina 27602 Post Office Box 629 Raleigh, North Carolina 27602 Mr. Mark S. Calvert Associate General Counsel Mr. Robert P. Gruber Carolina Power & Light Company Executive Director Post Office Box 1551 Public Staff - NCUC Raleigh, North Carolina 27602 Post Office Box 29520 Mr. Christopher Chappell, Chairman Board of Comissioners Post Office Box 249 Bolivia, North Carolina 28422 Mrs. Chrys Baggett State Clearinghouse Budget and Management 116 West Jones Street 4

Raleigh, North Carolina 27603 liesident Inspector U. S. Nuclear Regulatory Comission l Star Route 1 Post Office Box 208 '

Southport, North Carolina 28461 Regional Administrator, Region II U. S. Nuclear Regulatory Comission 101 Marietta Street, Suite 2900 Atlanta, Georgia 30303 Mr. Dayne H. Brown, Chief l

Radiation Protection Branch t

Division of Facility Services N. C. Department of Human Resources ,

701 Barbour Drive  !

Raleigh, North Carolina 27603-2008 i

i

!