Provides Addl Info Re Compliance W/Reg Guide 1.97 W/Respect to Containment Isolation Valve Position Indication & Request Approval for Deviation from Guidance
ML20141K140
Person / Time
Site: Waterford 
Issue date: 05/23/1997
From: Ewing E
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-REGGD-01.097, RTR-REGGD-1.097 W3F1-97-0120, W3F1-97-120, NUDOCS 9705280340
Download: ML20141K140 (16)


Text

- _ _ _ _ _ _ _ _ - - _ - - _ _ - _ _ - _ _ _ _ - -

,d 8

, E.ntergy ww*"""c-Killona. LA 70066 Tel 504 739 6242 Early C. Ewing, lil J

afety & Regulatory Af'arrs W3F1-97-0120 A4.05 PR May 23,1997 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Supplemental Response to RG 1.97, Revision 3 Gentlemen:

On February 28,1991, Waterford 3 submitted to the NRC letter W3F1-91-0019 which documented compliance with Regulatory Guide 1.97, Revision 3. This submittal was approved by the NRC on July 12,1993. The purpose of this letter is to provide additional information regarding compliance with RG 1.97 with respect to containment isolation valve (CIV) position indication and request approval for deviation from the guidance provided in RG 1.97 for several CIVs.

Table 1 of the 1991 submittal states that position indication is provided for all automatic containment isolation valves. ANSI N271-1976," Containment Isolation Provisions for Fluid Systems," defines " automatic isolation valve" as a valve whose closure is initiated by automatic means without any action by a plant operator upon receipt of an isolation signal from a protection system. Waterford 3 only included automatic isolation valves (i.e. only those which receive an automatic closure signal) in the scope of RG 1.97 submittal. Containment isolation valves which do not receive an automatic closure signal (i.e. those with a primary safety function to open) were not included in the submittal. That decision is believed to have been based on the following types of statements in RG 1.97: "At the start of an accident, it may be difficult for the operator to determine immediately what accident has occurred. For this reason, reactor trip and certain other safety actuations (e.g. containment isolation) have been designed to be performed automatically during the initial stages of an accident."

f@

9705280340 970523 M*^

@MMMHMEM

^

t t

2 C 8 U

i

,; n Supplemental Response to RG 1.97, Revision 3 W3F1-97-0120 Page 2 May 23,1997 Waterford 3 believes the 1991 submittal was clear as to which CIVs were included in the scope (valves were listed by component number); however, the submittal did not specifically identify the valves that were excluded. Thus, it is not clear that the NRC concurred with this exclusion. RG 1.97 does not appear to give exemption for CIVs which do not receive an automatic closure signal. ANSI /ANS-4.5-1980, which is endorsed by RG 197, states that position indication should be provided for remotely-operated primary reactor containment isolation valve positions (closed /not closed).

We recognize that although a number of CIVs have open safety functions, there may be a point in the accident when these valves may need to be closed to preserve containment and thus perform a closed safety function. Based on the above, we have determined that these additional remotely-operated CIVs should be included in the scope of RG 1.97. A review of the CIVs at Waterford 3 showed that nearly all of the remotely-operated CIVs have qualified position indication in the control room, including those which have an open safety function. Attachment 1 provides a list of the remotely-operated CIVs which were not included in Waterford 3's RG 1.97 submittal in 1991 with the exception of CS-129 A&B, and NG-412 A&B, which are passive components and are discussed below. The valves in Attachment 1 will be added to FSAR Table 7.5-3, " Accident Monitoring Instrumentation". The only valves in Attachment 1 which do not have RG 1.97 qualified position indication are MS-116

--A&B and CVC-209, which are also discussed below.

CS-129 A&B are the Containment Spray Riser Check Valve Bypass _ Valves and are located inside containment. These valves are solenoid-operated, normally closed, and fail closed on a loss of power (see Attachment 2). The purpose of these valves is to enable indication of containment spray riser level to be taken, which is performed once per shift per the requirements of TS 3/4.6.2.1. Riser level instrumentation is provided upstream of check valve CS-128 A(B). A reading is taken by depressing a push-button on the local control panel (RAB wing area) which energizes and opens CS-129 A(B) thus bypassing the check valve CS-128 A(B) and allowing the level instrument to measure riser level. When the push-button is released, CS-129 A(B) will close. Position indication lights are provided on the local control panel for CS-129 A(B) to ensure the valves re-close when deenergized. This local position indication loop is safety class 1E qualified and operates from magnetic reed switches on the valves which provide positive indication of physical valve

_ position.

l-i L

L Supplemental Response to RG 1.97, Revision 3 l

W3F1-97-0120 Page 3 j~

May 23,1997 NG-412 A&B are the Steam Generator Nitrogen Supply Valves. These valves are l

motor-operated and are normally locked closed during plant operation. These valves are opened during shutdown conditions to provide a nitrogen blanket for the steam generators (see Attachment 3). These valves are provided with Non-safety 120V

Vital AC Uninterruptable position indication in the control room which is provided by limit switches on the valve. However, for the purpose of containment isolation, NG-412 A(B) are considered to be passive components. The locked closed position of I

these valves (i.e., braker maintained open) is controlled by OP-100-009, " Control of Valves and Breakers" and by OP-903-031, " Containment Integrity Check." OP-903-031 implements TS surveillance requirement 4.6.1.1.a which requires monthly verification of certain CIV positions, including NG-412 A&B This monthly check includes independent verification of valve position. OP-100-009 provides for independent verification to ensure the valves are returned to their locked closed j

positions after being opened. These administrative controls provides positive indication of valve position at all times, and ensure these valves are closed during l'

l plant operation assuring containment isolation.

RG 1.97 states that Type B variables are those variables that provide information to indicate whether plant safety functions are being accomplished. For the purposes of containment isolation, CS-129 A&B and NG-412 A&B are considered to be passive -

components. The status of the safety function (closed) for these valves is positively known prior to the accident, and these valves remain closed throughout the accident.

l Thus, these valves are not considered to fall within the scope of RG 1.97 requiring post accident monitoring instrumentation. This conclusion is consistent with the Bases of NUREG-1432, "CE Revised Standard TS," which states, "In the case of CIV position, the important information is the isolation status of the containment penetration. For containment penetrations with only one active PCIV having control room indication, a single channel of valve position indication is required to be OPERABLE. This is sufficient to redundantly verify the isolation status of each isolable penetration via indicated status of the active valve, as applicable, and prior knowledge of passive valve or system boundary status." Waterford 3 requests the NRC's concurrence with this conclusion.

i MS-116 A&B are the main steam atmospheric dump valves (ADVs) (see Attachment 3). These valves are containment isolation valves and do not have RG 1.97 qualified position indication in the control room. These valves fait closed on a loss of actuator power and do contain safety-related limit switches which provide open and closed position indication in the control room (indication is on the plant computer and is non-l safety-related). The closed limit switch also provides an annunciator in the control

~.

l Supplemental Response to RG 1.97, Revision 3 W3F1-97-0120 Page 4

- May 23,1997 room which indicates when the valve is not fully closed..The AC power supply for the annunciator is classified as non-safety, but is supplied by the emergency diesel generator and is backed up by safety-related, seismically qualified batteries for a l

. Loss of Offsite Power (Non-safety 120V Vital AC Uninterruptable). The cables in this loop are designed to IEEE-383. The loop does not specifically meet Safety Class 1E requirements in that the cables are routed through non-safety-related raceways (i.e.

do not meet 1E separation criteria). The cable trays for these non-safety raceways are seismically-mounted; however, portions of conduit traversing from one tray to another may not be seismically qualified. This annunciator, however, is considered to be a reliable source of direct position indication (closed /not closed status) for these valves. Position indication for the ADVs was discussed in a letter to the NRC dated March 31,1986 titled " Supplement to the Detailed Control Room Design Review Summary Report." In this letter it was noted that monitoring of steam generator pressure along with valve demand indication and valve travel limit indication provide reasonable approximations of valve position. Safety-related 1E indication as well as RG 1.97 Category 2 non-1E Vital indication of Steam Generator pressure is provided in the control room. Additional alternative means to determine if 1

the ADVs are performing their containment isolation function include safety-related 1E (ARMIRD5028, ARMIRD5031) and non-safety-related (ARMIRD5500 A&B) radiation monitors which are located near each ADV on the roof of the Reactor Auxiliary Building and would indicate radiation releases in the area. Based on the above, Waterford 3 believes the ADVs possess reliable position indication and sufficient alternate means of indication to determine valve status should they be required for containment isolation purposes during an accident. Waterford 3 requests the NRC's approval for deviation from the RG 1.97 qualification requirements for these valves based on the above.

CVC-209 is the charging system header containment isolation valve outside containment. This valve contains direct position indication in the control room (control panel CP-4) which is non-safety powered. Leakage past this valve from the

. RCS is not expected while the charging system is in operation since the charging pumps are positive displacement thereby providing a higher pressure in the charging lines than in the RCS. The charging system receives an automatic SIAS signal to L

start two charging pumps, align the system to take a suction on the Boric Acid l

Makeup Tanks and inject borated water into the Reactor Coolant System. Flow l

through this penetration is guaranteed in this line under post-LOCA conditions, and L

credit is taken for flow in the small break LOCA analysis. During the post-LOCA period, the water in the Boric Acid Makeup Tanks may be depleted. When this happens, charging will be secured and the charging isolation valves will be shut.

y i--

,-r e

Supplemental' Response to RG 1.97, Revision 3 W3F1-97-0120 Page 5 May 23,1997 The need to close CVC-209 for containment isolation would only be expected for a line rupture. For most RCS break locations, the charging line will not be exposed to the containment atmosphere, since flow from the Safety injection system keeps the piping covered with fluid. In the event the break was in the RCS Cold Leg at a position which caused the charging line to be exposed to the containment atmosphere, there are still several barriers available. Inside containment there are 2 I

' valves in series in each charging path and outside containment there are check valves on each charging pump discharge in addition to the containment isolation valve. The charging pumps are positive displacement pumps further minimizing any j

back flow in the system. All of the piping is of high pressure design, and tho vaives l

. are subject to ASME section XI testing.

Waterford 3 is implementing procedural guidance to manually isolate the upstream manual isolation valve CVC-208 should this penetration need to be isolated. CVC-j 208 has local mechanical position indication and is accessible post-accident (this

]

action is discussed in letter W3F1-97-0107 submitted to the NRC on May 6,1997).

In addition, the inside containment isolation valves, CVC-216 A&B and CVC-218 l

A&B (see Attachment 4) contain qualified position indication in the control room.

l-Waterford 3 believes that the non-safety position indication for CVC-209, the l

qualified position indication for the inside CIVs, and the proceduralized action to manually shut CVC-208 provide positive assurance the CVC penetration status will be available should it be required during an accident. Waterford 3 requests the-NRC's approval for temporary deviation from the RG 1.97 qualification requirements for this valve until safety-related position indication can be provided to fully meet RG 1.97. This qualified position indication will be installed during Refueling Outage 9 (RF09), which is currently scheduled for the Fall of 1998.

^

l l

Supplemental Respr

, to RG 1.97, Revision 3 W3F1-97-0120 Page 6 May 23,1997 i

Should you have'any questions concerning the above please contact me at l

(504) 739-6242.

Very truly yours, l

r

/~

u

/

E.C. Ewing Director Nuclear Safety & Regulatory Affairs ECE/DFUssf Attachments cc:

E.W. Merschoff, NRC Region IV C.P. Patel, NRC-NRR J. Smith N.S. Reynolds NRC Resident inspectors Office t

l l

l

ATTACHMENT 1 SUPPLEnENTAL RESPONSE TO RG 1.97 REVtSION 3 ADOmONAL CONTANGENT ISOLATION VALVE POSmON DOICATIONS RG1.97 POWER NUheER SERtAL TYPE /

LOOP COMP SUPPLY OF SPDS NUh4hER VARIABLE CAT COMPONENT TYPE LOCATION ENV SEIS QA CLASS RANGEANTS CHANNELS llo N

021 CN1MT ISOL B1 MS IZSO401A S

RB B

A A

1E EnERG CLOSED NOT CLOSED 1NALVE MA MSWAAA401A EnERGENCYSG VLV POSmON NOT AVAAABLE I

CP4 FEED PUhr TUR8HES. NOTE 1,2.

021 CNTMT ISOL.

81 MS IZSO4018 S

RB B

A A

1E EnERG CLOSED NOT CLOSED 1NALVE MA MSWAAA4016 EnERGENCYSG VLV POSITION NOT AVA8.ASLE I

CP4 FEED PUhr TUR91NES. NOTE 1.2.

021 CNTMT ISOL 81 MS IZS0116A2 S

RS B*

B A

N1E VITAL - CLOSED NOT CLOSED 1NALVE MA MSWAAA116A ATMOSPHERIC VLV POSmON AlWUN. RA0781 1

CP4 STEAM DUhr. NOTE 12 021 CNTMT ISOL 81 MS IZS011882 S

R8 B*

B A

NIE VITAL CLOSED NOT CLOSED 1NALVE MA MSWAAAttG8 ATMOSPHERIC VLV POSmON ANNUN. N8791 1

CP4 STEAM Dt.2@. NOTE 12 021 CNTMT ISOL B1 CVRIZS01011/2 S'

ANN A

A A

1E VITAL CLOSED NOT CLOSED 1NALVE N/A CVRMVAAA101 CONTAMENT VLV POSmON NOT AVAA.ABLE I

CP-18 VACUUM REUEF. NOTE 1.

021 CNTMT ISOL B1 CVRIZS02011/2 S

ANN A

A A

1E VITAL CLOSED NOT CLOSED 1NALVE MA CVRMVAAA201 CONTAMENT VLV POSmON NOT AVAILABLE I

CP-18 VACUUM RELIEF. NOTE 1.

021 CNTMT ISOL B1 CClZS0007A1/2 S

RB A

A

.s 1E EhERG CLOSED NOT CLOSED 1NALVE N/A CCWAAA807A cot @ONENT VLV POSmON NOT AVAILABLE 1

CP-18 COOUNG WATER INLET TO CNTimT FAN COOLER UNITS.

NOTE 12 021 CNTMT ISOL 81 CCIZS0007B1/2 S

RB A

A A

1E EnERG CLOSED NOT CLOSED INALVE N/A CCWAAA8078 CORPONENT VLV POSmON NOT AVA8.ABLE I

CP-18 COOUNG WATER N.ET TO CNTDMT FAN COOLER UNITS.

NOTE 12 021 CNTMT ISOL 81 CClZS0808At/2 S

R8 A

A A

1E EhERG CLOSED NOT CLOSED 1NALVE MA CCWAAA808A COhrONENT VLV POSITION NOT AVALABLE I

CP-18 COOLNG WATER INLET TO CNTnWT FAN COOLER UNITS.

NOTE 1,2.

021 CNTMT ISOL 81 CC1ZS000881!2 S

RB A

A A

1E EhERG CLOSED NOT CLOSED INALVE MA CCMVAAA8088 COh@ONENT VLV POSITION NOT AVAiABLE I

CP-18 COOUNG WATER INLET TO CNTimT FAN COOLER UNITS.

NOTE 12 021 CNTMT ISOL B1 CClZS0822A1/2 S

R8 A

A A

1E EhERG CLOSED NOT CLOSED 1NALVE MA CCMVAAA822A COhrotENT VLV POSmON NOT AVAILABLE I

CP-18 COOUNG WATER OUTLET FROM t

CNTnmT FAN COOLER UNITS, NOTE 12

? p.1 of 7 i

m m

..-....wa a m. -

2.

.. m. -=m- -.-

--.. -.-.2.

.-. m-..-...--.-...

.a-.

l j

ATTACHMENT 1 SUPPLEMENTAL RESPONSE TO RG 1.97. REVISION 3 ADDITIONAL CONTAMENT ISOLATION VALVE POSITION NDICATIONS RG1.97 POWER NUMBER SERIAL TYPE /

LOOP COMP SUPPLY OF SPDS NUMBER VARIABLE CAT COMPONENT TYPE LOCATION ENV SETS OA CLASS RANGEANTS CHANNELS 10 CohmENTS 021 CNTMT ISOL B1 CCES082281/2 S

RB A

A A

1E ElERG CLOSED NOT CLOSED 1NALVE MA CCMVAAA822B CONPONENT VLV POSITION NOT AVALABLE I

CP-18 COOUNG WATER OUTLET FROM CNTWT FAN COOLER UNITS.

NOTE 1.2.

02t CNTMTISOL B1 CCES0823A112 S

RB A

A A

1E EIERG CLOSED NOT CLOSED 1NALVE MA CCMVAAA823A COMPONENT VLV POSITION NOT AVARABLE I

CP-18 COOUNG WATER OUTLET FROM CNTWT FAN COOLER UNITS.

NOTE 12 021 CNTMT ISOL Bt CCES08238112 S

RB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE MA CCMVAAA8238 COMPONENT VLV POSITION NOT AVAILABLE I

CP-18 COOUNG WATER OUTLET FROM CNTWT FAN COOLER UN!TS.

NOTE 12 021 CNTMT ISOL 81 CS ES0125A1/2 S

RB A

-4 A

1E EMERG CLOSED NOT CLOSEU 1NALVE N/A CSMVAAA125A CONTAINhENT VLV POSITION NOT AVAILABLE I

CP4 SPRAY. NOTE 1.

021 CNTMT ISOL B1 CS ES012581/2 S

RB A

A A

1E EfERG CLOSED NOT CLOSED 1NALVE N/A CSMVAAA1258 CONTAMAENT VLV POSITION NOT AVAILABLE I

CP4 SPRAY. NOTE 1.

021 CNTMT ISOL B1 SI ES0138A S

RB A

A A

1E EIERG CLOSED NOT CLOSED 1NALVE MA St MVAAA138A SAFETYINJECTION VLV POSITION NOT AVARABLE I

CP4 FROM LPSI PUhPS. NOTE 1,3.

021 CNTMT ISOL B1 St ES0138B S

RB A

A A

1E ENERG CLOSED NOT CLOSED 1NALVE N/A StMVAAA1388 SAFETYINJECTION VLV POSITION NOT AVAA ABLE I

CP4 FROM LPSI PUhPS. NOTE 1.3.

021 CNTMT ISOL B1 StES0139A S

RB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE MA SiMVAAA139A SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 FROM LPSI PUhPS. NOTE 1.3.

021 CNTMT ISOL B1 SI ESGi398 S

R8 A

A A

1E EMERG CLOSED NOT CLOSED INALVE MA StMVAAA1398 SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 FROM LPSI PUMPS. NOTE 1,3.

021 CNTMTISOL B1 St ESO405A1!2 S

RCB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE MA St MVAAA405A SAFETYINJECTION WV POSITION NOT AVAR.ABLE I

CP4 SHUTDOWN COOUNG. NOTE 1.

021 CNTMT ISOL B1 St ESO405B112 S

RCB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE MA StMVAAA4058 SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SHUTDOWN COOLING. NOTE 1.

021 CNTMT ISOL B1 SI ESO407A S

RB A

A A

1E EhERG CLOSED NOT CLOSED 1NALVE N/A St MVAAA407A SAFETY INJECTION VLV POSITION NOT AVAILABLE I

CP4 SHUTDOWN COOUNG. NOTE 1. p. 2 of 7

=

. ~

ATTACHMENT 1 StJPPLEbENTAL RESPONSE TO RG 1.97, REVISION 3 ADDITIONAL CONTAINhENT ISOLATION VALVE POS! TION INDICATIONS RGi.97 POWER NUMBER SERIAL TYPEI LOOP COhe SUPPLY OF SPDS NUMBER VAR 1ABLE CAT COMPONENT TYTE LOCATION ENV SEIS OA CLASS RANGE / UNITS CHANNELS 1/0 COMAENTS 021 CNTMT ISOL B1 St IZSO407B S

RB A

A A

1E EMERG CLOSED NOT CLOSED INALVE MA StWAAA407B SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SHUTDOWN COOUNG. NOTE 1.

021 CNTMT ISOL B1 SIIZS0225A S

RB A

A A

1E EhERG CLCGED NOT CLOSED tNALVE N'A StMVAAA225A SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SYSTEM FROM HPSt LOOP 1 A.

NOTE 1,3.

021 CNTMT ISOL B1 St IZS0225B S

RB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE MA StMVAAA2258 SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SYSTEM FROM HPSI LOOP 1 A.

NOTE 1,3.

021 CNTMT ISOL B1 St IZS0226A S

RB A

A A

1E EMERG CLOSED NOT CLOSED tNALVE N/A SIWAAA226A SAFETYtNJECTON VLV POSITION NOT AVAILABLE I

CP4 SYSTEM FROM HPSI LOOP 18.

NOTE 1.3.

021 CNTMT ISOL B1 SIIZS0226B S

RB A

A A

1E EIERG CLOSED NOT CLOSED 17 E

N/A St MVAALN SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SYSTEM FROM HPSI LOOP 18.

NOTE 1,3.

021 CNTMT ISOL B1 St IZS0227A S

RB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE WA StMVAAA227A SAFETYP4JECTION VLV POSITION NOT AVAR.ABLE I

CP4 SYSTEM FROM HPSI LOOP 2A.

NOTE 1.3.

021 CNTMT ISOL B1 SI12S0227B S

RB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE MA StMVAAA2278 SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SYSTEM FRCM HPSI LOOP 2A.

NOTE 1.3.

021 CNTMT ISOL B1 SilZS0228A S

RB A

A A

1E EMEh7 CLOSED NOT CLOSED 1NALVE MA SIWAAA228A SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SYSTEM FROM HPSI LOOP 28.

NOTE 1,3.

021 CNTMT ISOL B1 St tZS0228B S

RB A

A A

1E ELERG CLOSED NOT CLOSED 1NALVE WA SiMVAAA2288 SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 SYSTEM FROM HPSt LOOP 28.

NOTE 1.3.

021 CNTMT ISOL B1 St IZS0506A S

RB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE KA SiWAAA506A SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 HOT LEG INJECTION. NOTE 1.3.

021 CNTMT ISOL 81 St IZS05068 S

RB A

A A

1E EMERG CLOSED NOT CLOSED INALVE NA StMVAAA506B SAFETYINJECTION VLV POSITION NOT AVAILABLE I

CP4 HOT LEG INJECTON. NOTE 1.3. p. 3 of 7 m

m -

.1 ATTACFNENT 1 SUPPLEMENTAL RESPONSE TO RG 1.97, REVISION 3 ADDmONAL CONTAMAENT ISOLATION VALVE POSITION INDICATIONS RG1.97 POWER NUMBER SERIAL TYPE!

LOOP CObP SUPPLY OF SPDS NUMBER VARIABLE CAT COhPONENT TYPE LOCATION ENV SEIS QA CLASS RANG *MS CHANNELS WO COMENTS 021 CNTMT ISOL B1 CVCIZS02091/2 S

R8 C

B B

NIE VITAL CLOSED NOT CLOSED 1NALVE N/A CVCMVAAA209 CHEMCAL AND WV POSmON NOT AVAILABLE I

CP-4 VOLUME CONTROL CHARGING LINE. NOTE 1.

021 CNTMT ISOL 81 CVCtSV0216A S

RC8 A

A A

1E EMERG CLOSED NOT CLOSED tNALVE N/A CVCMVAAA216A CHEMCAL AND WV POSmON NOT AVAILABLE I

CP-4 VOLUME CONTROL CHARGING LINE. NOTE 1.

021 CNTMT tSOL 81 CVCtSV02168 S

RC8 A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE N/A CVCM/AAA2168 CHEMCAL AND VLV POSmON NOT AVAILABLE I

CP-4 VOLLNE CONTROL CHARGING LINE. NOTE 1.

021 CNTMT ISOL 81 CVCISV0213A S

RCS A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE N/A CVCM/AAA218A CHEMICAL AND WV POSmON NOT AVAILABLE I

CP-4 VOLtJfE CONTROL CHARGING LINE. NOTE 1.

021 CNTMT ISOL 81 CVCtSV02188 S

RCB A

A A

1E EMERG CLOSED NOT CLOSED 1NALVE N/A CVCMVAAA2188 CHEMICAL AND VLV POSITION NOT AVAILABLE I

CP-4 VOLUME CONTROL CHARGING LINE. NOTE 1.

' p. 4 of 7

NOTES FOR ATTACHMENT 1 TABLE:

NOTE 1: This valve does not receive an automatic closure signal.

t i

NOTE 2: One containment isolation valve outside the containment is provided for certain lines penetrating the containment through Class C or Class D penetrations. (FSAR subsection 6.2.4.1.2 provides further details).

Dedicated indication for this valve is provided in the control room t

NOTE 3: Redundant valve provided for subject line is either a check valve or locked closed valve. Only power operated valve on subject line is provided with a dedicated indication in the control room (Refer to FSAR Section 6.2.4).

'e GUIDE FOR ATTACHMENT 1 TABLE:

I Column Headina Description i

SERIAL NUMBER:

Sequential number for each variable in RG 1.97 (as listed in W3F1-91-0019).

VARIABLE:

Name of the variable as defined in RG 1.97.

RG 1.97 TYPE / CAT:

Type and Category of variable as defined in RG 1.97.

i l

LOOP COMPONENT:

UNID numbers of sensing and indicating devices that are part of the f

instrumentation loop.

l t

COMPONENT TYPE:.

Defines the function of the component as follows:

j S:

Sensing Device j

1:

Indicating Device t

i f

i L

h p. 5 of 7 f

.i LOCATION:

Provides the building location for sensing device or the Control Panel number for.

indicating device. Following abbreviations are used:

l

' RB:

Reactor Building (Wing Area)

RCB: Reactor Containment Building ANN: Annulus Shield Building ENV:

Defines Environmental Qualification status of the loop.

A-All or part of the instrumentation loop components fall within the scope of 10CFR50.49 and NUREG-0588. Loop components located in a harsh environment are qualified for the environment in which they are located.

i B:

The instrument loop is Class 1 E, is located in a mild environment and is I

designated to function in such an environment.

  • Limit switches for MS-116 A&B are class 1E, power supply for indication is non-1 E vital.

C:

The instrument is non-Class 1 E and is designed to withstand its specific p

service environment.

SEIS:

Defines Seismic Qualification status of the loop. Following notation is used:

l A-Applicable components of this loop are seismically qualified in accordance

[

with the criteria of FSAR section 3.10.

B:

Portions of this indication loop are not seismically qualified.

1 i

L

< p. 6 of 7

~

QA-Defines Quality Assurance level of loop. Following notations are used:

A-Either all or part of the components of this instrument loop are Class 1E or installed on safety class 1, 2, 3 lines or have an LP&L safety class designation of "SR". As such it is subject to quality assurance program -

requirements in accordance with 10CFR50 Appendix B.

B:

This loop is Non-Class 1E but it requires Quality Assurance requirements to support EQ and/or SQ requirements as specified by RG 1.97 Rev. 3.

POWER SUPPLY CLASS:.

Classifies the power supply of loop components. NOTE: Vital receives power from uninterruptable power source. Emergency is backed up by Diesel Generator and/or Batteries.

RANGE / UNITS:

Defines the range and the units for the instrument.

NUMBER OF CHANNELS:

Identifies total number of channels provided for tais variable.

SPDS1/O:

Point identification for Safety Parameter Display System.

COMMENTS:

Provides comments appliccble to loop.

[

i i

i

! p. 7 of 7 l

.iw

3 Simplified Schematic of Containment Spray Riser (Train A) l l

n

/\\ A A A A Outside Spray Nozzles I

Containment i

l l CS-128A [

][

CS-129A I

I I

Inside Containment Containment g

Spray Pump CS-Il7A A

N k

=

CS-125A I

=

i

Simplified Schematic of Main Steam Isolation (Train A)

Atmosphere JL I

Inside As sareties (6)

MS-116A Containment l

O JL ji MS-115A h=

MS-124A i

I NG-412A

{

MS-401A I

Outside Steam V

Containment Generator l

Jk To 2 EN#1 N

g 2

I m

Simplified Schematic of Charging Penetration

~

I Inside q

l Containment l

CVC-209 l

q CVC-216A

>@4 X

i M

cyc-208 To q

l cyc-2i6n m

Aux.

>g M

Spray I

g Charging CVC-218B Pumps Outside l

N

> To RCS Containment cyc-2iar N

> To RCS I

CVC-220 I

r+4><F CVC-219

=>

m