I ENCLOSURE 1 NOTICE OF VIOLATION 4

i Alabama Power Company Docket No. 50-364 Farley 2 License No. NPF-8 The following violations were identified during an inspection conducted on November 19 - December 18, 1985. The Severity Levels were assigned in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C).

Technical Specification 6.8.1.b requires that written procedures be imple-l mented covering refueling activities. This includes receipt and inspection of new fuel.

Contrary to the above, on November 21,1985 at 2:35 p.m., Fuel Handling Procedure FNP-0-FHP-3.0 was not fully implemented in tnat during new fuel receipt and inspection, the top frame fastener nuts on the new fuel shipping carriage were released by a licensed operator who had not been briefed on the fuel handling procedure prior to performing the v The procedure required the top fastener to be released only when the fuel was brought to the vertical position and the new fuel lif ting tool had been engaged. This resulted in damage to the new fuel assembly.

This is a Severity Level V violation (Supplement I).

Parsuant to 10 CFR 2.201, you are required to submit to this office within 30 days of,the date of this' Notice, a written statement or explanation in reply, 4

includingi (1) admission or denial of the alleged violations; (2) the reasons for the violations if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

Security or safeguards information should be submitted as an enclosure to facilitate withholding it from public disclosure as required by 10 CFR 2.790(d) or 10 CFR 73.21.

09 M Date:

l

~ e601140150 e60109 PDR ADOCK 05000348 o