DUKE POWER GOMPAhT P.O. BOX 33180 CHARLOTTE, N.C. 28242 (704 37 531 December 20, 1985 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention:

Mr.

B. J. Youngblood, Project Director PWR Project Directorate No. 4 Re:

Catawba Nuclear Station, Unit 1 Docket No. 50-413 Technical Specification Amendment

~

Dear Mr. Denton:

Enclosed is a tabular listing of changes requested in my letters of March _15, 1985, August 7, 1985, October 30, 1985, November 7, 1985 and December 17, 1985 concerning the proposed Catawba Units 1 and 2 Technical Specifications.

The changes listed are those that will affect the Unit 1 license.

It is requested that these changes be incorporated as an amendment to the Technical Specifications for Facility Operating License No. NPF-35.

It is recognized that some of the proposed changes will not be incorporated into the combined Technical Specifications due to schedular constraints.

Changes which are to be deferred will be pursued after the issuance of the Operating License for Catawba Unit 2.

Be advised that the deferred changes are viewed as improvements over the current Specifications but do not reflect correction of any errors contained in the Unit 1 Specifications.

It is Duke's understanding that corrections to the errors that have been identified (e.g. the typographical error identified on page 3/4 3-40, item 13, where "N.A." is not appropriately placed) will be incorporated into the combined Technical Specifications.

8512260066 851220 i

PDR ADOCK 05000413 P

PDR L

h oo\\

d 4

Mr. Harold R. Danton, Direc' tor I

December 20, 1985 Page Two There are several of the proposed Technical Specification changes that we want to delete, specifically:

Page #

Proposed Change To Be Deleted 3/4 3-12 The additions to Table Notations (3) and (6),

3/.4 4-20 The addition to ACTION C.,

-3/4 6-2 The addition to Surveillance 4.6.1.2, 1/4 6-42 The change to Surveillance 4.6.5.7c, and 3/4 7-32 The deletion of Surveillance 4.7.10.4b. (2) 3/4 7-39, 40 & 41 The revised Standby Shutdown Facility Specification 3/4.7.13 Also, two clarifications (attachment 2) are proposed to previously submitted changes.

On page 6-6 add " Revision 13" after "Section 13.1.3" and on page 6-8, the proposed change should now read

" Station Manager or Superintendent of Station Services".

This request involves an amendment request to Catawba's Technical Specifications.

Accordingly, pursuant to 10 CFR 170.21 a check for

$150.00 is enclosed.

Pursuant to 10 CFR 50.91(b) (1) the appropriate South Carolina State

. Official is being provided a copy of this amendment request.

If there are any questions concerning this application, please contact Mr. Roger Ouellette at (704)373-7530.

Very truly.yours, db Hal B. Tucker RWO:slb Attachment 4

Mr. Enrold R. Danton,_ Director December 20, 1985 Page Three cc:

Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. Heyward G. Shealy, Chief Bureau fo Radiological Health S. C. Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Mr. P.

H.

Skinner NRC Resident Inspector Catawba Nuclear Station e

~

-n-4 g -

Mr. Hnrold R. Danton, Director December 20, 1985 Page Five HAL B. TUCKER, being duly sworn, states that he is Vice President of Duka Power Company; that he is authorized on the part of said Company to sign aria file with the Nuclear Regulatory Commission this revision to the Catawba Nuclear Station License No. NPF-35 and that all-statements and matters set forth therein are true and correct to the best of his knowledge.

Hal B. Tucker, Vice President Subscribed and sworn to before me this 20th day of December, 1985.

0pd

_4 Notary Public My Commission Expires:

!j 9 stIIIllet s

ig L. KE 0

4

~4

$y.'

=

= ra :l 6 0Th"r.%.i "r*

20:

lj$2.,

  1. UBL d',/Iij i,i...... b..

l l

l L

Table of Proposed Char ges i

f 8

9 i

Page #

Remarks 2-2 Change "1700" to "1775" on Figure 2.1-1 2-5 Relocate " Low" in Item 16.a in Table 2.2-1 2-8 Change "At RATED THERMAL POWER" to " Allowed by Safety Analysis",

Change " exceeds" to "is more negative than" and change " exceeds" to "is more positive than".

3/4 0-2 Add Specification "3.0.5 Limiting Conditions for Operation including the associated ACTION requirements shall apply to each unit individually unless otherwise indicated as follows:

a.

Whenever the Limiting Condition for Operation refers to systems or components which are shared by both units, the ACTION requirements will apply to both units simultaneously.

This will be indicated in the ACTION section; b.

Whenever the Limiting Condition for Operation applies to only one unit, this will be identified in the APPLICABILITY section of the specification; and c.

Whenever certain portions of a specification contain operating parameters, setpoints etc., which are different for each unit, this will be identified in parentheses or footnotes.

(For example, "... flow rate of 54,000 cfm (Unit

1) or 43,000 cfm (Unit 2)...")."

3/4 1-12 Type correction (31.2.2 to 3.1.2.2), and change "100*F" to "114 F" 3/4 2-2 Add "The provisions of Specification 3.0.4 are not applicable for operation up to 50% of RATED THERMAL POWER" to Action c., and Add "c.

The provisions of Specification 4.0.4 are not applicable" to 4.2.1.1.

3/4 2-6 Move Figure 3.2-2 to page 3/4 2-8 3/4 2-7 Change "0.3" to "0.2" l

3/4 2-10 Move Figure 3.2-3 to page 3/4 2-11 and Add " Acceptable Operation" and " Unacceptable Operation" 3/4 2-14 Add "c.

The provisions of Specification 4.0.4 are not applicable." to 4.2.4.1 3/4 2-16 Change parameters and limits on Table 3.2-1 from,

" Indicated Reactor Coolant System T,y 5 592.5 F Indicated Pressurizer Pressure

> 2220 psig*

Page #

Remarks to, Average Temperature Meter average-

- 4 channels: 5 592*F

- 3 channels: 5 592*F Computer average - 4 channels: 5 593 F

- 3 channels: 5 593*F Pressurizer Pressure Meter average

- 4 channels: 1 2227 psig*

- 3 channels: 1 2223 psig*

Computer average - 4 channels: 1 2222 psig*

- 3 channels: 1 2224 psig*

3/4 3-3

. Relocate " Low" in Item 16.a in Table 3.3-1 3/4 3-4 Add "(Above P-10)" and "#####" to Item 18.e and Add "###" to Item 18.f.

3/4 3-5 Add "##### Above the P-10 (Low Setpoint Power Range Neutron Flux Interlock) Setpoint." to Table Notations in Table 3.3-1 3/4 3-8 Relocate " Low" in Item 16.a in Table 3.3-2 c

3/4 3-10 Relocate " Low" in Item 16.a in Table 4.3-1 3/4 3-11 All "(Above P-10)" and "####" to Item 18.e and Add "(Below P-10)"

and "###" to Item 18.f in Table 4.3-1 3/4 3-12 Add "#### Above P-10 (Low Setpoint Power Range Neutron Flux Interlock) Setpoint." to Table Notations, Add "For this speci-fication the frequency shall be 31 EFPD." in Note (3), and Add "For this specification the frequency shall 'e 92 EFPD." in Note (6) in Table 4.3-1 3/4'3-15 Delete " Ventilation" from " Filtered Ventilation Exhaust" in Item 1 c.

3/4 3-18 Change " loop" to "stm gen" in Item 5.b in Table 3.3-3 3/4 3-19 Change " loop" to "stm gen" in Item 6.c in Table 3.3-3 3/4 3-21 Delete "6 " from Items 8.g.1) and 2), Change "5231" to "5232" and delete "1" from 8.g.1) and 2) 3/4 3-23 Delete " Ventilation" from Item 16 3/4 3 Add "with flow through the HEPA filters and carbon adsorbers" to ACTION 24.

Page #

Remarks 3/4 3-27 Delete " Ventilation" from Item 1 3/4 3 Delete "1" from 8.g.1) and 2)

/

3/4 3-32.

Change "<" to "<" in Item 12.c 3/4 3-34 Delete " Ventilation" from Item 16

-3/4 3-37 Delete " Ventilation" from Item 1.1.

3/4 3-38 Delete " Ventilation" from Items 2.a.12) and 3.a.12) 3/4 3-39 Delete " Ventilation" from Item 4.a.12) 3/4 3-40 Delete "N.A." from Item 13 3/4 3-41 Delete "1" from 1KC305B and 1KC315B in Table Notation (2) 3/4 3-42 Delete " Ventilation" from Item 1

~

3/4 3-49 Delete " Ventilation" from Item 16 3/4 3-52 Change "All" to "1,2,3,4" in item 4

'3/4 3-53 Change " charcoal" to " carbon" in ACTION 31, 34 and 35, Delete

" recirculation" in Action 31, and delete " Ventilation" in ACTION 35-3/4 3-54 Change "All" to "1,2,3,4" in Item 4 3/4 3-62 Change " HOT SHUTDOWN" to " HOT STANDBY" and change "12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />" to "6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />." in ACTION a.

3/4 3-65 Change " HOT SHUTDOWN" to " HOT STANDBY" and change "12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />" to "6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />." in ACTION

a. and b.

3/4 3-66 Change "2/ Steam generator" to "1/ steam generator" in Item 9.

3/4 3-70 Typo correction (" system" to " System")

3/4 3-71 Change " fire-detection instruments" to " smoke detection or flame detection instruments" and " Fire detectors" to " Detectors" in 4.3.3.8.1., and

~

Change " fixed temperature / rate of rise" to " heat" in 4.3.3.8.2a.

3/4 3-73 Change Zone 9 smoke from "13" to "14" and Heat from "11(6)" to "12(6)", Zone 27 Smoke from "15" to "20" and Heat from "15" to "20", Zone 28 Smoke from "1" to "6" and Heat from "1" to "6" and Zone 46 Smoke from "7" to "13" and Heat from "7" to "13".

Page #

Remarks 3/4 3-74 Change Zone 65 Smoke from "15" to "16" and Heat from "15" to "16", Zone 66 Smoke from "4" to "11" and heat from "4" to "11",

Zone 82 Smoke from "3" to "28" and Heat from "3" to "27", Zone 84 Smoke from "9" to "17" and Heat from "9" to "17" and change Zones 131 to 141 by moving " Bel." to just before "El."

3/4 3-75 Change "23" to "25" for Zone 72 and Change Zones 142 to 149 by moving "Be1." to just before "El."

3/4 3-76 Change Zone 184 Location from "43+0" to "El. 543+0," Change Zone 185 Description from "207A" to "209A" and Change Zone RF1B Heat from "(10" to "(10)".

3/4 3-79 Add "per station" to Items 1.a, 2, 3.a, 3.b and 3.c.

3/4 3-82 Typo correction (CHANNNEL to CHANNEL).

3/4 3-84 Add "per station" to Items 1.a, 1.b, 2.a, and 2.b.

3/4 4-2 Add "and the reactor trip breakers in the closed position" and "within I hour" to ACTION b.

3/4 4-10 Change "both" to "more than one" and "PORV(s)" to "PORV" in ACTION c.

3/4 4-11 Add "N " to 4.4.4.3a., Add "b.

Isolating and venting the normal 2

(air) supply, and", Change 4.4.4.3b. to 4.4.4.3c., and add footnote "*Not applicable to Unit I until after the first refueling outage."

3/4 4-14 Change "at least once per 20 months" to "not less than 12 months or more than 24 months." in 4.4.5.3b.

3/4 4-15 Change "and" to "or repaired by an acceptable method such as steering.

It" is 4.4.5.4a.6).

3/4 4-16 Add "or repair" to 4.4.5.4b. and add "or repaired" to 4.4.5.5b.3).

3/4 4-17 Delete two and three loop information from Table 4.4-1.

3/4 4-18 Add "*"'s to " plug"'s and add footnote "*Where plugging is indicated, steering or other approved repair methods are acceptable."

3/4 4-19 Change " Gaseous" to " Particulate" in 3.4.6.la., add "Either" and change "and" to " subsystem or the" in 3.4.6.lb., and change

" Particulate" to " Gaseous" in 3.4.6.1c.

3/4 4-20 Add "While in Mode 1 or 2" to ACTION c.

3/4 4-22 Delete "1" from valve numbers and delete all drawing numbers.

Page #

Remarks 3/4 4-23 Delete "1" from valve numbers, delete all drawing numbers, and change "RHR" to " Residual Heat Removal".

3/4 4-40,.41 Add Specification 3/4.4.11 REACTOR COOLANT SYSTEM VENTS.

3/4 5-1 Add "with power removed" to 3.5.1.la., and add "and power is removed" to 4.5.1.la.

3/4 5-2 Change "2000" to "1000", and delete 4.5.1.1.1d.1) and 2).

3/4 5-6 Delete "1" from valve numbers in 4.5.2a.

3/4 5-7 Delete "1" from valve numbers in 4.5.2g.2).

3/4 6-2 Add "as supplemented by ANSI 56.8 (1981)" to 4.6.1.2.

3/4 6-7 Add penetration "M328 and add footnote "*Not applicable for Unit I until after the first refueling outage,"

3/4 6-9 Add "III.D.2 (b) (ii)".

3/4 6-14 Change " charcoal" to " carbon" in 4.6.1.8a and b., delete "(1),

and "or (2)...the system" is 4.6.1.8b. and change the footnote from "the requirement...and operating." to " pursing of residual refrigerant is not mandatory."

3/4 6-15 Change " charcoal" to " carbon" in 4.6.18c., d.1) and f., delete "when tested in accordance with ANSI N510-1980" from 4.6.1.8d.5) and add new surveillance 4.6.1.8g.

'3/4 6-17 Add " valves" in 4.6.1.9.4.

3/4 6-36 Change "3" to "18" and delete "during the first year after the ice bed is initially fully-loaded and at least once per 6 months thereafter" in 4.6.5.3.lb., change "25%" to "50%", and "four" to "two" in 4.6.5.3.lb.3).

3/4 6-37 Change "25%" to "50%" and "four" to "two" in 4.6.5.3.lb.4).

3/4 6-42 Change "66" to "100" in 4.6.5.7c.

3/4 7-1 Change " COLD" to " HOT" and "30" to "6" in ACTION a.

3/4 7-3 Delete "1" from valve numbers on Table 3.7-2.

3/4 7-5 Typo correction (move "and" from 4.7.1.2.la.3) to a.4)).

3/4 7-12 Add "(Units 1 and 2)" after ACTION.

3/4 7-13 Add "(Units 1 and 2)" after ACTION.

I Page #

Remarks 3/4 7-14 Change " charcoal" to " carbon", delete "(1)" and ", or (2) following painting, fire, or chemical release in any ventila-tion zone communicating with the system" in 4.7.6c.

Change

" charcoal" to " carbon" in 4.7.6d., e.1) and e.2). Add " relative to adjacent areas" and change " adjacent areas" to "the control room" in 4.7.6e.3).

Delete "when tested in accordance with ANSI N510-1980", in 4.7.6e.4)., and change footnote from "The require-ment for reducing refrigerant concentration to 0.01 ppm may be satisfied by operating the system for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> with the heaters on and operating." to " Purging of residual refrigerant is not mandatory."

'3.4-7-15 Change " charcoal" to " carbon" in 4.7.6e.5) and 4.7.6g., and add surveillance 4.7.6h.

3.4 7-16 Change " charcoal" to " carbon" in 4.7.7a., delete "or (1) after any structural maintenance on the HEPA filter or charcoal adsorber housing, or (2) following painting, fire, or chemical release in any ventilation zone communicating with the system" in 4.7.7b., change "30,000" to "60,000" in 4.7.7b.1) and change footnote from "The requirement for reducing refrigerant concen-tration to 0.01 ppm may be satisfied by operating the system for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> with the heaters on and operating." to " Purging of residual refrigerant is mandatory."

3/4 7-17 Change "30,000" to "60,000" in 4.7.7b.3), change " charcoal" to " carbon" in 4.7.7c., d.1), d.2) and f., Add "per fan" to 4.7.7d.1), e. and f., Delete "when tested in accordance with ANSI N510-1980" from 4.7.7d.5), Add "After any structural maintenance on the filter housing or, "to 4.7.7e. and f.,

and Add surveillance 4.7.7g.

3/4 7-18 Add " functional" to 4.7.8a., add "and by type. Each category may be inspected independently." to 4.7.8b., and add " Time Until" to inspection interval chart in 4.7.8b.

3/4 7-19 Delete "of each type" from 4.7.8e.

3/4 7-20 nelete "for each snubber type" from 4.7.Sc., delete "of a type" from 4.7.8e.1), insert proposed new wording for 4.7.8e.2) and delete 4.7.8e.3).

3/4 7-22 Change " functionally tested" to " evaluated in a manner to ensure their OPERABILITY" and change " testing" to " evaluation" in 4.7.8g., and add "of the affected snubber" and change "The replacements (snubbers or critical parts) shall be documented and the " to "All" in 4.7.8i.

3/4 7-23 Delete the " REJECT" line from Figure 4.7-1.

3/4 7-28 Add " accessible" to ACTION a. in two places.

3/4 7-32 The proposed change to 4.7.10.4b.2) is to be deleted.

Page #

Remarks 3/4 7-39, Delete current Specification 3/4.7.13 and replace with proposed 40 & 41 Specification 3/4.7.13 (based on McGuire SSS submittal) and add

"(Units 1 and 2)" after ACTION:

3/4 8-7 Add footnote "# A maximum of two calls may be jumpered out at a time."

3/4 8-24 Delete breaker "1EMXK-F07A" and corresponding description.

3/4 8-26 Delete breaker "1EMXL-F06C" and corresponding description.

3/4 8-35 Add:

IMXY-F02C Reactor Building Lower Primary Bkr Containment Welding Backup Fuse Machine Receptacle IRCPL0185 3/4 8-43 Add:

6 DC Welding Circuits IEQCB0001 Lower Containment Primary Bkr-AA DC Welding Circuit Backup Bkr-AB IEQCB0002 Upper Containment Primary Bkr-AA DC Welding Circuit Backup Bkr-AB 3/4 9-5 Change " charcoal" to " carbon" in 4.9.4.2a., b., c. and d.1, delete

"(1)" and " or (2) following painting, fire, or chemical release in any ventilation zone communicating with the system" from 4.9.4.2b. and change the footnote from "*The requirement for reducing refrigerant concentration to 0.01 ppm may be satisfied by operating the system for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> with heaters on and operating."

to " Purging of residual refrigerant is not mandatory."

3/4 9-6 Delete "when tested in accordance with ANSI N510-1980." and "and" from 4.9.4.2d.2), change " charcoal" to " carbon" in 4.9.4.2f., and add Surveillance 4.9.4.2g.

3/4 9-14 Change " charcoal" to " carbon" in 4.9.11.1 and 4.9.11.2a.. Delete "or (1) after any structural maintenance on the HEPA filter or charcoal adsorber housings, or (2) following painting, fire, or chemical release in any ventilation zone communicating with the system: in 4.9.11.2b., change "16,565" to "33,130" in 4.9.11.2b.1),

and change the footnote from "*The requirement for reducing refrigerant concentration to 0.01 ppm may be satisfied by oper-ating the system for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> with the heaters on and operating."

to " Purging of residual refrigerant is not mandatory."

3/4 9-15 Change "16,565" to "33,130" in 4.9.11.2b.3), change " charcoal" to " carbon" in 4.9.11.2c., d.1) and f., add "per fan" to 4.9.11.2d.1), e. and f., delete "when tested in accordance with ANSI N510-1980" and add "any structural maintenance on the filter housing, or after" to 4.9.11.2c. and f.

Fage #

Remarks 3/4 9-16 Add surveillance 4.9.11.2g.

(new page)~

.3/4 10-1 Add "and being relied on for the SHUTDOWN MARGIN requirement" to 4.10.1.2.

~1 3/4 11-3 Typo corrections ("to., s to_sec~1, and s to sec).

3/4 11-4 Delete "Mo-99" and add "and Mo-99" to Table Notation (3).

~1

~1 3/4 11-11 Typo corrections (s to sec and s to sec).

3/4 11-12 Delete "Mo-99" and add "and Mo-99" to Table Notation (2).

3/4 12-1 Raise "+" up in equation in ACTION b.

3/4 12-2 Change " vegetable" to " vegetation" in ACTION C.

3/4 12-5 Add " low level" to Table 3.12-1 in three places (twice to item 3.c. and once to item 4.a.).

3/4 12-6' Delete "three different kinds of broad leaf", "each of the", and

" broad leaf" from item 4.c. in Table 3.12-1.

3/4 12-7 Change " analyzed for gross beta radioactivity" to " held for",- add "before gamma isotopic analysis is performed." and delete "If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples. " in Table Notation (3) to Table 3.12-1.

3/4 12-9

~ Change "2" to "20(')" and "0.9" to "1" on Table 3.12-2 for I-131.

3/4 12-10 Delete "0.01" for Gross Beta and change "l(4),, u "15(5)" for I-131 on Table 4.12-1.

~1 1

2/4 12-11 Typo corrections (s to sec and s to sec).

3/4 12-12 Add Table Notation "(4) Reporting 1cvel for gamma isotopic analysis.

If the calculated dose for drinking water exceeds 1 mrem /yr, low level I-131 analysis shall be performed and 'a reporting level of 2 pei/1 shall be used." and add " (5) LLD for gamma isotopic analysis. 'If low level I-131 analysis is performed, an LLD of 1 pci/1 shall apply."

5-3 Replace current Figure 5.1-2 with new Figure 5.1-2 6-1 Add "for each unit" and change "the" to "either" in 6.2.2b. and change "the" to "either" in 6.2.2c.

6-3 Replace current Figure 6.2-1 with new Figure 6.2-1.

Page #

Remarks 6-4 Replace current Figure 6.2-2 with new Figure 6.2-2.

6-5 Replace current Table 6.2-1 with new Table 6.2-1 and delete "8-hour" from footnote "*".

6-6 Change "of Regulatory Guide 1.8, September 1975." to " outlined in the Catawba FSAR, Section 13.1.3 Revision 13." in 6.3.1.

6-8 Change " Station Manager" to " Station Manager or Superintendent of Station Services" in 6.5.1.8.

6-13 Delete " implementation" and "erviro1 mental" and add "and implementation of the environmental radiological monitoring program." to 6.8. lg., and add "or (4) Station Services Superintendent (the Security Plan only)" and change "Maintenace" to " Maintenance" in 6.8.2.

6-17 Change " Appendix B shall be supplemented with three additional categories:

class of solid wastes (as defined by Part 61), type of container (e.g., LSA, Type A, Type B, Large Quantities), and SOLIDFICATION agent or adsorbent (e.g., cement, urea formal-dehydes)." to "The Radioactive Effluent Release Reports shall include the following information for each class of solid waste (as defined by 10CFR Part 61) shipped offsite during the report period:

a.

Total Container volume, b.

Total Curie quantity (specify whether determined by measure-ment or estimate),

c.

Principal radionuclides (specify whether determined by measurement or estimate),

d.

Source of waste and processing employed (e.g., dewatered spent resin, compacted dry waste, evaporator bottoms),

e.

Type of euulainer (e.g., LSA, Type A, Type B, Large quantity) and f.

Solidification agent or absorbent (e.g., cement, urea formal-dehyde)."

6-20 Delete "i. Records of quality assurance activities required by the Operational Quality Assurance Manual." and reletter the remaining items accordingly in 6.10.2.

6-21 Add "6.10.3 Records of Quality Assurance activities required by the Operational Quality Assurance Manual shall be retained for a period of time as recommended by ANSI N45.2.9-1974."

Page #

Remarks 7-1 Delete Section 7.0 SPECIAL TEST PROGRAM and page 7-1 in its entirely.

l*

s.

s Additional clarifications i