ML20138E422

From kanterella
Jump to navigation Jump to search

Forwards SE Which Provides Review of Relief Requests VR-29 & VR-30 Included in Inservice Testing Program for Plant,Unit 1
ML20138E422
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 09/16/1994
From: Wessman R
Office of Nuclear Reactor Regulation
To: Norris J
Office of Nuclear Reactor Regulation
Shared Package
ML20136C539 List: ... further results
References
FOIA-96-485 TAC-M88977, NUDOCS 9409210128
Download: ML20138E422 (1)


Text

.- _

SEP 161994 met 10RA'00M TO:

Jan A. Norris, Project Manager i

Project Directorate II-2 Division of Reactor Projects I/II FROM:

Richard H. Wessman, Chief Mechanical Engineering Branch Division of Engineering

SUBJECT:

REVIEW 0F INSERVICE TESTING PROGRAM RELIEF REQUESTS ST. LUCIE PLANT, UNIT I - TAC NUMBER M88977 I

The attached safety evaluation provides the Mechanical Engineering Branch's review of Relief Requests VR-29 and VR-30 included in the inservice testing program for the St. Lucie Plant, Unit I.

This completes the actions for the branch for TAC number M88977.

1 Docket No. 50-335

Attachment:

Safety Evaluation cc w/ attachment:

IST Service List Distribut'on:

c

-ar rme EMD Reading / Plant /Chron DOCUMENT NAME: 6:\\ CAMPBELL \\!STSERS\\STLUC.994 CSee previous concurrence.

D receive a repyg :his document, Indicate in the has C=Capy ta/o attedument/enetoewe E=capy with attactument/enetesure s = no capr 0FFICE EQ*

E EMEB*

N EMEB N

NAME PCampbell GJohnson RWessman7b DATE 9/14/94 9/15/94 9 / 4 /94 '

0FFICIAL l(ECORD COPY FILENAME: G:\\ CAMPBELL \\ISTSERS\\STLUC.994 3 -nf 47_

(T7+o9 AloJih j' NBC Ms CETJTER COPYg,