p utQ

[

LA &

[

UNITED STATES

[

g NUCLEAR REGULATORY COMMISSION "g

E WASHINGTON, D. C. 20555 kg.....[

September 9, 1983 s

MEMORANDUM FOR:

Richard E. Cunningham, Director Division of Fuel Cycle and Material Safety Office of Nuclear Material Safety and Safeguards FROM:

Richard C. DeYoung, Director Office of Inspection and Enforcement

SUBJECT:

REVISION OF 10 CFR PART 35 We have reviewed the subject revision transmitted by your memo dated August 26, 1983 and we have no comments. Harriet Karagiannis, phone number 492-9655, will be the IE contact with the task force members revising 10 CFR Part 35.

Richard C. D Young Director Office of pection and Enforcement CONTACT: Harriet Karagiannis, IE 492-9655 8509230633 850906 PDR PR 35 50FR30616 PDR

_ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Topic Current Proposed Why the Change was Made A teletherapy AU T&E draft tele-35.960 require " adequate" therapy RG App B B teletherapy safety draft tele-35.610,.633 provides workers with a procedures therapy RG uniform course of action App G A supervision of physicians RG 10.8 54.4* 35.38 allows training of physicians and technicians A licensure of unnamed policy 35.2 legalizes receipt, use, and users disposal by technicians A RSO T&E RG 10.814.8 35.900 identifies RSO T&E A AU T&E RG 10.8 35.910,.920 AU needs to know when to App A

.930,.940 prescribe, how to handle safely A Survey meter calibration RG 10.8 35.951 survey instruments are needed App D 1 to measure radiation levels A dose calibrator cali-RG 10.8 35.950 needed to measure dosages, bration App D 2 avoid misadministration A area survey procedures RG 10.8 35.70 assures control, notice of App I unnecessarily high levels A waste disposal RG 10.8 35.92 ensures proper decay-in-App J storage method A staff briefing for RG 10.8 35.304 ensures ancillary staff is radiopharmaceutical App K briefed on safety measures therapy A staff briefing for RG 10.8 35.404 ensures ancillary staff is brachytherapy App L briefed on safety measures A ventilation, control of RG 10.8 35.90,.205 avoids unnecessary worker gases App M exposure to gases C amendments RG 10.8 35.17 gives notice as to when App N amendments are needed A ALARA program RG 10.8 35.30 requires management commitment App 0 to ALARA