Dt:KE POWER GoxPAxy 15.0. HOX 30180 CitAltLOTTE. N.C. 28242 IIAL H. TUCKER returnome ens resessaise (704) 373-4534 January 10, 1986 un.

-n-Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention:

Ms. E.G. Adensam, Chief Licensing Branch No. 4

Subject:

McGuire Nuclear Station Docket Nos. 50-369 and 50-370 Technical Specification Amendment Relative to the Number of Reactor Coolant Pumps in Operation when in Mode 3

Dear Mr. Denton:

Attached are proposed license amendments for McGuire Nuclear Station Facility Operating Licenses NPF-9 (Unit 1) and NPF-17 (Unit 2).

The proposed changes to the Technical Specifications seek to:

1.

Correct an inconsistency between the McGuire Nuclear Station accident analysis in the FSAR and McGuire's Technical Specification 3.4.1.2 and Bases 3/4.4.1 regarding the number of operating reactor coolant pumps when in hot standby; and 2.

Ensure that in the event of any limiting accident at zero power the design basis will be met.

Attachment I contains the proposed Technical Specification changes. Attachment II provides a Technical Justification and Safety Analysis in support of the proposed changes. Attachment III provides an analysis confroming to the standards contained in 10 CFR 50.92 as required by 10 CFR 50.91.

This analysis concludes that the proposed amendments would not have an adverse safety or environmental impact.

This request involves one application for amendment to the McGuire's Technical Specifications. Accordingly, pursuant to 10 CFR 170.21, a check for $150.00 is enclosed.

Please feel free to contact us if you require any additional information.

Very truly yours, O f al B. Tucker i

JGT/jgm bi)

Attachments 8601240240 860110 PDR ADOCK 05000369 P

PDR

'H.R.benton January 10, 1986 Page 2 cc:

Dr. J. Nelson Grace, Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, Suite 2900 Atlanta, Georgia 30323 Mr. W.T. Orders Senior Resident Inspector McGuire Nuclear Station Mr. Dayne Brown, Chief i

Radiation Protection Branch Division of Facility Services Department of Human Resources P.O. Box 12200 Raleigh, North Carolina 27605 6

H.R. Denton, Director January 10, 1986 Page 3 HAL B. TUCKER, being duly sworn, states that he is Vice President of Duke Power Company; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commiseion this revision to the McGuire Nuclear Station License Nos. NPF-9 and NPF-17 and that all statements and matters set forth therein are true and correct to the best of his knowledge.

C Mk Hal B. Tucker, Vice President Subscribed and sworn to before me this 10th day of January, 1986.