  • i QCP 100-525

+

l Revision 3 EFFLUENT AND HASTE DISPOSAL May 1985 SEMI-ANNUAL REPORT January-June 1985 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Quarter Quarter Est. Total Unit First Second Error. %

A.

FISSION & ACTIVATION GASES m

l.

Total Release C1 367 727 2.

Average release rate for period uCl/sec 47.2 92.5

~

3.

Percent of Tech Spec limit *

.293

.Hz Chimney & stack

.100

.176

,j B.

IODINE i

1.

Total Iodine-131 C1 1.4E-02 5.7E-03 1

2.

Average release rate for period uCl/sec 1.8E-03 7.2E-04 l

C.

PARTICULATES l.

Particulates with half-lives

> 8 days C1 3 2E-02 3.5E-02 2.

Average release rate for period uCl/sec 4.1E-03 4.5E-03 3.

Gross alpha radioactivity Cl 9.6E-06 1.1E-05 0.

TRITIUM i

1.

Total Release C1 21.5 7.07 2.80 0.90 2.

Average release rate for period uC1/sec l

E.

Iodine 131 & 133, Tritium and Particulates Percent of Tech spec Limit Chimney & stack

.183

.121

2uCLE SC0Y/ CRC?" Art.

  • Nobel Gas Gamma eta l

APPROVED 8508270231 850813 PDR ADOCK 05000254 R

PDR JUN 061985 l

9/0295c Q.C.O.S.R.

(

QCP 100-525 Revision 3

,1 e-

?

l GASEQUS EFFLUENTS Continuous Mode Batch Mode Quarter Quarter Quarter Quarter

_}.

Nucildes Released Unit First Second i

1.

Fission gases Main Chimney Kr-85 C1

<LLD

<LLD Kr-85m Cl 5.57 33 7 Kr-87 Cl 5.00 34.1 t

l Kr-88 Cl

<LLD 39 1

~

Cl 17.2 173 Xe-133 i

3 X3-135 Cl 72 3 235 Xe-135m Cl 58.1 43.1 1

168 133 Xe-138 Cl Cl Cl Cl Unidentifled Cl 326 691 Total for Period C1 2.

Iodines I-131 Cl 1.11E-02 4.63E-03 I-133 Cl 6.70E-02 4.07E-02 I-135 Cl 6.20E-02 7.21E-02 Total for Period Cl 1.40E-01 1.17E-01 A?PRCVED

).;> d i:,'3 9/0295c

0. C. O. 3. 7.
i. -

CCP 100-525

/

e" Revision 3 j

1 GASEOUS EFFLUENTS Continuous Mode Batch Mode j

he" ongr Qu_a_rter Qu_arter t

Nucildes R leased Unit rst 3.

Particulates Main Chimney 4

4 SR-89

  • C1 1.22E-03 1.45E-03 i

SR-90

  • C1 3.65E-05 3.08E-05 Cs-134 Cj 7.10E-05 1.17E-04 l

Cs-137 C1 4.34E-04 8.78E-04

-t Ba-140 Cl 3 24E-03 2.54E-03

<8 Day Half Line La-140 C1

'i Cr-51 C1

<LLD

<LLD l

Mn-54 C1

<LLD

<LLD

<LLD

<LLD Co-58 C1 9.60E-04 1.02E-03 t

Co-60 Cl 7.50E-04 3 95E-04 I-131 C1

<LLD 2.1E-05 AQ-110m Cl f.

7 38E-03 6.10E-03 l-133 C1

'i-135 Cl

9. E-03 8.20E-03 C1 Cl Cl Unidentified C1
  • Sr-89, Sr-90 Valves for May and June are Projected APPROVID

.'UN O 31933 Q.C.O.S.R.

9/0295c 3_

l'

'I QCP 100-525 Revision 3 GASEOUS EFFLUENTS 3

Continuous Mode Batch Mode Quarter Quarter Quarter Quarter Nuclidet Released Unit First Second I.

Fission gases Reactor Vent Kr-85 C1

<LLD

<LLD Kr-85m Cl

<LLD

<LLD Kr-87 Cl

<LLD 3 01 Kr-88 C1

<LLD

<LLD Xe-133 C1 1.2 24.8 I

X3-135 Cl 17.6 9 13 1

Xe-135m Cl 3.01

<LLD

}

<LLD

<LLD Xe-138 C1 t

Cl Cl 4

21.8 36.9 Total for Period C1 2.

Iodines 1.99 -03 4.93E-04 I-13I Cl

-03 3 02E-03 I-133 Cl

-03 4.61E-03 I-135 C1 8.81E-03 8.17E-03 Total for Period Cl l

J hFF RO Vi.,

JU.'i0iiC]3 Q. C. O. 3..?.

3/0295c

=

QCP 100-525 Revision 3

'~

GASEOUS EFFLUENTS i

Continuous Mode Batch Mode kNoj7 AN Qua w l

Nuclides Released Unit rs l

3.

Particulates Reactor Vents SR-89

  • Cl 5.38E-05 3.47E-04 SR-90
  • Cl 4.53E-05 3.48E-05 Cs-134 Cl 7 5E-05 5.03E-05 Cs-137 C1 3 26E-04 1.06E-03 Ba-140 C1 3.42E-04 4.45E-04 i

La-140 Cl

< 8 Day Half Line 5 90E-04 8.78E-04 Cr-51 Cl

<LLD 3.7E-05 Mn-54 Cl

<LLD 3.6E-05 Co-58 C1

\\

2.97E-03 2.01E-03 Co-60 CI 1.36E-04 1.44E-04 I-13I Cl

<LLD 4.56E-05 Aq-II0m Cl 1.80E-03 1 54E-03 l-133 d

1.76E-03 7.65E-03 I

l-135 C1 Ru-103 1.87E-04

<LLD Cl Cl Unidentified Cl t

  • S r-89, Sr-90 Valves for May and June are Projected APPROVID

.lU.'i 0 3 ll.'3 9/0295c O. C. O. S. ;t

i QCP 100-525 Revision 3 e

APPROVE 0 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES IN H 1935 Q.C.O.S.R.

Quarter Quarter Est. Total

-l Unit Error, %

A.

FISSION & ACTIVATION PRODUCTS 1

l.

Total release (not including I'

tritium, gases, alpha)

C1 4.4E-03 3.8E-02 2.

Average 011uted concentration I

during batch dischargest period urI/ml 2.2E-09 1.7E-08 3.

Percent of appilcable limit

  • 4.

Maximum diluted concentration j

during batch discharges uCl/ml 3.2E-09 5.6E-09,

B.

TRITIUM

.)

I I

1.

Total 8elease Cl

.86 1.35 i

l 2.

Average diluted concentration during batch discharges uCl/ml 4.4E-07 6.0E-07 i

3.

Percent of applicable limit 1.5E-02 2.0E-02 C.

DISSOLVED AND ENTRAINED GASES I.

Total release C1 3.42E-04 2.18E-04 2.

Average diluted concentration during batch discharges uCl/mi 1 7E-10 9.6E-11 3.

Percent of aoolicable limit 5.4E-05 1.9E-05 O.

GROSS ALPHA RADI0 ACTIVITY i

<LLD

<LLD 1.

Total Release Cl 2.

Average concentration released

~

during batch discharges uCl/ml E.

VOLUME OF WASTE RELEASED (prior to dilution Liters 4.8E+05 5.3E+05 I

F.

VOLUME OF OILUTION WATER USED OURING BATCH OISCHARGES Li ters 1.96E409 2.26E+09 l

G.

TOTAL VOLUME OF DILUTICN 8.28E+10 8.31E+10 HATER DURING PERIC-D (CUARTER)

Liters

  • WHCLE ECC(/CRGA.'l 3/0295c b

QCP 100-S25 Revision 3 LIQUID EFFLUENTS Continuous Mcde Batch Mode Quarter Quarter Quarter Quarter Nuclides Released Unit.

First Second I

SR-89

  • Cl 5.14E-05 3.17E-05 SR-90
  • C1 8.03E-06 2.88E-02 l

Cs-134 Cl 4.58E-05 3.68E-05 Cs-137 C1 7.70E-04 1.17E-03 I-131 C1 8.30E-06 5 91E-05 l

J Co-58 C1 4.50E-05 1.82E-04 1

Co-60 C1

~

1 99E-03 5.17E-03

~

i Fe-59 Cl

< LLD 6.43E-05 I

6.40E-05 6.11E-05 Zn-65 CI 1.92E-04 3.63E-03 Mn-54 Cl 7.60E-04 1.33E-03 Cr-51 Cl

< LLD

< LLD i

Zr-95 C1

<LLD

< tL9 Nb-95 C1

< LLD

<LLD Mo-99 C1

< LLD 3.60E-04 Aq-110m C1 D

<LLD Ba-104 Cl D

<LLD Cs-136 Cl Y

'I"*

La-140 Cl Fe-55

  • 4.18E-04 7.57E-04 i

C1 Unidentified C1 4.35E-03 3.84E-02 Total for Period (above)

Ci 1 95E-04 1.98E-04 Xe-133 C1 1.47E-04 1.98E-05 Xe-135 Cl b

Prepared by hrM M

Approved by APPROVED Rad-Cehm Supervisor

  • Sr-89, Sr-90, Fe-55 for May abd 9dM are Projected.

i um5:

JUN0SE35

SOLID RADI0 ACTIVE WASTE

SUMMARY

UNITS 1/2 OUAD-CITIES STATION 1/1985 DATE C0 TRANS BURIAL VOLUME MILLICURIES SITE 01/03/85 CN BSC 178.00 8280.00 01/03/05 TRI-STATE BSC 26.20 13183000.00

-01/07/85 CN BSC 178.00 7603.00 01/11/85 CN BSC 178.00 8216.00 01/11/85 HACKE USE 872.00 408.62 01/12/85 TRI-STATE BSC 26.20 11069000.00 01/14/85 CN BSC 178.00 10390.00 01/16/85 CN BSC 178.00 9894.00 01/16/85 TRI-STATE BSC 26.20 10457000.00 01/18/85 CH BSC 178.00 9549.00 01/19/85 TRI-STATE BSC 26.20 10616000.00 01/21/85 CH BSC 178.00 9566.00 01/23/85 CN BSC 105.00 81.80 01/23/85 CN BSC 178.00 7275.00 01/23/85' HACKE USE 999.50 151.82 01/23/85 TRI-STATE BSC 26.20 7482000.00 01/24/85 CH USE 105.00 937.00 01/30/85 CN BSC 178.00 9986.00 x x x x xx x x x x x x x x x x x x x x x x x ** x x x

  • x x x x x x x MONTHLY TOTALS 3814.50 52889338.24 USE - U.S.

ECOLOGY BSC - BARNWELL' SOUTH CAROLINA CN

- CHEM NUCLEAR CD,.

TS

- TRI STATE

4 SOLID RADIDACTIVE WASTE

SUMMARY

UNITS 1/2 GUAD-CITIES STATION 2/1985 DATE CD TRANS BURIAL VOLUME MILLICURIES SITE 02/04/85 CN BSC 178.00 8875.00 02/08/85 CN BSC 178.00 6718.60 02/11/85 CN BSC 178.00 6241.00 02/13/85 CN BSC 178.00 5928.60 02/21/85 CN BSC 178.00 5076.00 02/22/85 HACKE USE 1289.75 56.17 JO2/25/85 CN BSC 178.00 4736.10 02/27/85 CH BSC 178.00 5689.60 02/28/85 HACKE USE 585.00 451.60

    • x*
          • x x x x x xx x x x x x x x **** ** ******

HONTHLY TOTALS 3120.75 43772.67 USE - U.S.

ECOLOGY BSC - BARNMELL SOUTH CAROLINA CN

- CHEM NUCLEAR CO.

TS

- TRI STATE

e s

SOLID RADI0 ACTIVE HASTE

SUMMARY

UNITS 1/2 OUAD-CITIES STATION 3/1985 DATE CO TRANS BURIAL VOLUME MILLICURIES SITE 03/04/85 CN BSC 178.00 5000.00 03/06/85 CN BSC 178.00 5339.00 03/08/85 CN BSC 178.00 3096.00 03/13/85 CN BSC 178.00 7441.00 03/14/85 HACKE USE 1289.75 93.49 03/18/85 CN BSC 170.00 19151.00 03/21/85 CN BSC 178.00 13547 00 03/26/85 CN BSC 178.00 7528.00 03/27/85 CH BSC 178.00 10644.00 03/29/85 CN USE 110.50 1256.90

  • x x x x x x x x x x x * * * * * * * * *
  • x x * * * *
  • x ** * * *
  • MONTHLY TOTALS 2824.25 73096.39 USE - U.S.

ECOLOGY BSC - BARNWELL SOUTH CAROLINA CH

- CHEM NUCLEAR CO.

TS

- TRI STATE

1 SOLID PADI0 ACTIVE HASTE

SUMMARY

UNITS 1/2 GUAD-CITIES STATION 4/1985 DATE CO TRANS BURIAL VOLUME MILLICURIES SITE 04/01/85 CN BSC 178.00 9949.00 04/02/85 HACKE USE 1289.75 412.50 04/03/85 CN BSC 178.00 6380.10 04/10/85 CN BSC 178.00 6111.00 04/11/85 HACKE USE 570.00 500.21 04/15/05 CN BSC 178.00 5298.70 04/17/85 CH BSC 178.00 4551.00 04/19/85 HACKE USE 1289.75 202.55 04/19/05 CN USE 105.00 1747.80 04/22/05 CN BSC 178.00 4113.00 04/29/85 CH BSC 178.00 2648.00 m* **********************************

HONTHLY TOTALS 4500.50 41913.86 USE - U.S.

ECOLOGY BSC - DARNWELL SOUTH CAROLINA CH

- CHEN NUCLEAR CD.

TS

- TRI STATE

s SOLID RADI0 ACTIVE WASTE

SUMMARY

UNITS 1/2 OUAD-CITIES STATION 5/1985 DATE C0 TRANS BURIAL VOLUME HILLICURIES SITE 05/02/85 HACKE USE 532.50 653.80 05/02/85 CN BSC 178.00 3668.00 05/06/85 CH BSC 178.00 3708.10 05/08/85 CH BSC 178.00 2965.00 05/08/85 HACKE USE 1289.75 80.03 05/13/85 CN BSC 178.00 10243.20 05/15/05 HACKE USE 1289.75 106.58 05/16/85 CH BSC 178.00 17762.00 05/20/85 CN BSC 178.00 13265.00 05/23/85 CN BSC 178.00 9893.00 05/30/85 CN BSC 178.00 11069.00 05/31/05 HACKE USE 1289 75 55.67 05/31/85 CH USE 105.00 514.93 x*

  • x
  • x x x* x * *** * **
              • x x x xx x x ****

NONTHLY TOTALS 5930.75 73984.31 USE - U.S.

ECOLOGY BSC - BARHWELL SOUTH CAROLINA CH

- CHEH HUCLEAR CO.

TS

- TRI STATE l

N l

i l

i,

r SOLID RADI0 ACTIVE WASTE

SUMMARY

UNITS 1/2 QUAD-CITIES STATIDH 6/1985 DATE CD TRANS BURIAL VOLUME MILLICURIES SITE 06/03/85 CN BSC 178.00 8995.00 06/06/85 CN BSC 178.00 11894.00 06/10/85 CN BSC 178.00 10177.00 06/12/85 CH BSC 178.00 7244.00 06/12/85 HACKE USE 1289.75 81.88 06/17/85 CN BSC 178.00 7529.00 06/19/85 CN BSC 178.00 7533.00 06/20/85 HACKE USE 728.50 352.19 06/24/85 CN BSC 178.00 7600.00 06/26/85 CN BSC-178.00 9017.40 06/27/85 HACKE USE 1063.80 72.81

      • x x x x x x x x x x x x x x x x x x * *
      • x x *
  • x x x x x x HONTHLY TOTALS 4506.05 70496.28 z

USE - U.S.

ECOLOGY BSC - BARNMELL SOUTH CAROLINA l

CH

- CHEM NUCLEAR CO.

TS

- TRI STATE e