A UNITED STATES

qh k

,j, NUCLEAR REGULATORY' COMMISSION 3

WASHINGTON, D. C. 20555 e

,s 04 W Mr. Charles Barnes 1574 Bellevue Street, SE IN RESPONSE REFER Salem, OR 97301 TO F01A-85-644

Dear Mr. Barnes:

This is in response to your letter dated September 20, 1985, in which you requested, pursuant to the Freedom of Information Act (FOIA), all records from June 25, 1975,to March 1, 1976, relating to the incident described in IE Bulletin 75-07.

The enclosed appendix identifies records responsive to your request. These records are being placed in the NRC's Public Document Room (PDR), 1717 H Street, NW, Washington, DC 20555, in file folder F01A-85-644. Should you wish to obtain copies of these records, I have enclosed a copy of the notice that provides charges and procedures for obtaining copies of records directly from the PDR.

Since ely,

  1. A

. M. Felton, Director Division of Rules and Records Office of Administration

Enclosures:

As stated 8511210476 851104 PDR FOIA BARNES85-644 PDR i

Re: F01A-85-644 APPENDIX 1.

Undated Extracted page 6 from I&E Inspection Reports 070-925/75-05 and 070-1193/75-15.

2.

08/15/75 Memo to H. D. Thornburg from J. A. Hind re: Kerr-McGee HEPA Filler Incident.

(1 page) i 3.

08/15/75 Letter to W. J. Shelley from J. A. Hind re: Investigation of Waste Shipment Incident of June 25, 1975 w/ attached IE Investigation Report No. 070-1193/75-09.

(9 pages) 4.

.09/05/75 Letter to Jack Hind from W. J. Shelley re: Investigation of Waste Shipment Incident of July 25, 1975.

(3 pages) 5.

09/10/75 Letter to W. J. Shelley from Jack A. Hind re: Item of Noncompliance.

(1 page)

T u-

ll

t

) _

(.

D.

r

{

IE Bulletin No. 75-07 Date:

Novecber 26, 1975 DESCRIPTION OF CIRCIP5 TRICES:

Nuclear Engineering Co=pany, Inc. (NECO), Louisville, Kentucky notified

,/

the Kerr-McGee Nuclear Corporation snd IE:III on, respectively, June 30, r

1975, and July 2,1975, that they had received a waste shipnent at their Beatty, Nevada burial site from the Cimarron Plutonium facility in a Super Tiger shipping container (Certificate No. 6400) on June 25, 1975.

Ylhen the shipment was opened by NECO on June 26, 1975, they found evidence that an exothermic reaction had taken place inside a DOT Specification 120 fiberboard carton containing a 24" x 24" x 12" acid resistant HIPA filter.

The box was ther= ally hot on receipt and the outside of the box was i

scorched. The nylon filament tape used to seal the box had celted, fusing l

the box to another box.

Less than 450 c/m of alpha contmimtion was detected on the box and it was ic=ediately buried.

)

This filter was identified as one serving a glovebox system in which nitric acid is used to dissolve scrap oxide catorials for purification.

~

l Nitrogen oxide gases and water vapor were released through the filter.

The filter had been bagged out in a 4 cil polyethylene (PE) bag, placed j

in the original shipping carton, packaged again in another PE bag before i

being placed in the DOT 12B fiberboard carten. On another occasion a similar filter package had emitted nitrogen oxide fumes while in storage at the Kerr4fcGee plutonium plant.

J The cause of the reaction is unknown, since cost of the constituent catorials in the HEPA filter do not readily react with nitric acid.

The exothertic reaction may have occurred in extraneous materials placed in the package l

or in the packaging caterial itself.

ACTION TO BE TAKEN BY LICENSEES:

The following actions are requested of reprocessing plants, fuel cycle i

j plants and cajor laboratory licensees:

l l

1.

Review your present or planned operations to determine if there are I

processes that emit corrosive gases, particularly nitrogen oxide, into ventilation systets filtered by HEPA filters.

l 4

2.

Review your procedures for the handling, packaging, storing, and shipping of-caterials, particularly cellulose caterials or other readily oxidicable substances that have been expeced to nitric acid, nitrogen oxide gases, or other oxidicing agents, to determine if appropriate precautions are being taken to preclude an exothermic 4

reaction.

3 Report to this office, in writing within 30 days of the date of this Bulletin, the results of your review and, if apprcpriate, the i

actions you have taken or planned to correct these problems.

Recorda i

of your evaluations should be maintained for exanination during the next routine inspection of your facility.

4 w w ?1 Q.

-