MONTHYEARML20236N4521998-07-0606 July 1998 Application for Amend to License R-28,adding Condition B(5) to License to Read as Listed ML20217M2531998-04-0202 April 1998 Application for Amend to License R-28,revising TS to Incorporate Safety Channel on Reactor Coolant Inlet Temp That Was Installed to Address Problem on 970930 ML20059M3081993-10-27027 October 1993 Application for Amend 40 to License R-28,revising TS to Accommodate Implementation of New 10CFR20.Rev 2 to Safety Analysis Encl ML20244D4931989-05-0808 May 1989 Application for Amend to License R-28,modifying Tech Specs Sections 3.1.6 & 6.1.6 Re Shutdown Margin During shim-safety Rod Insp & Licensed Senior Reactor Operator on Shift Whenever Reactor Operating,Respectively ML20137C4531985-12-0202 December 1985 Application for Amend to License R-28,eliminating Supervisor of Reactor Operations Block from Figure 6.1 on Page 35. Assistant Reactor Manager Has Assumed All Supervisor Responsibilities ML20135H8011985-09-18018 September 1985 Application for Amend to License R-28,changing Tech Spec 3.1 Re Subcritical State of Reactor During Fuel Loading Changes ML20135A3311985-09-0404 September 1985 Application for Amend to License R-28,changing Tech Spec Section 3.1 Re Subcriticality of Reactor During Fuel Load Changes.Revised Tech Spec Page 9,superseding 841130 Submittal,Encl ML20138L5571980-04-0202 April 1980 Application to Amend License R-28,authorizing Conversion from High to Low Enriched U Fuel 1998-07-06
[Table view] Category:TEXT-LICENSE APPLICATIONS & PERMITS
MONTHYEARML20151Z2651998-09-17017 September 1998 Amend 45 to License R-28,adding License Condition to Allow Greater Flexibility in Receipt & Possession of Byproduct Matl Used to Support Research & Development within Facility ML20236N4521998-07-0606 July 1998 Application for Amend to License R-28,adding Condition B(5) to License to Read as Listed ML20216J3281998-04-16016 April 1998 Amend 44 to License R-28,revising TS to Add Coolant Inlet Temperature Rundown ML20217M2531998-04-0202 April 1998 Application for Amend to License R-28,revising TS to Incorporate Safety Channel on Reactor Coolant Inlet Temp That Was Installed to Address Problem on 970930 ML20059M3081993-10-27027 October 1993 Application for Amend 40 to License R-28,revising TS to Accommodate Implementation of New 10CFR20.Rev 2 to Safety Analysis Encl ML20245F9741989-08-0404 August 1989 Amend 33 to License R-28,consisting of Changes to Tech Specs to Reflect Administrative Changes & Operational Status of Facility ML20244D4931989-05-0808 May 1989 Application for Amend to License R-28,modifying Tech Specs Sections 3.1.6 & 6.1.6 Re Shutdown Margin During shim-safety Rod Insp & Licensed Senior Reactor Operator on Shift Whenever Reactor Operating,Respectively ML20236U1961987-11-24024 November 1987 Amend 32 to License R-28,reflecting Revised Physical Security Plan That Shows New Measures Used to Protect SNM of Low Strategic Significance Resulting from Conversion to Low Enriched U Reactor Fuel ML20141N1091986-02-24024 February 1986 Amend 31 to License R-28,revising Tech Specs to Eliminate Ref to Supervisor of Reactor Operations ML20137C4531985-12-0202 December 1985 Application for Amend to License R-28,eliminating Supervisor of Reactor Operations Block from Figure 6.1 on Page 35. Assistant Reactor Manager Has Assumed All Supervisor Responsibilities ML20136G8831985-11-19019 November 1985 Amend 30 to License R-28,changing Tech Spec Section 3.1(5) to Conform W/Changes Made When License Renewed on 850728 ML20135H8011985-09-18018 September 1985 Application for Amend to License R-28,changing Tech Spec 3.1 Re Subcritical State of Reactor During Fuel Loading Changes ML20135A3311985-09-0404 September 1985 Application for Amend to License R-28,changing Tech Spec Section 3.1 Re Subcriticality of Reactor During Fuel Load Changes.Revised Tech Spec Page 9,superseding 841130 Submittal,Encl ML20133C1841985-07-29029 July 1985 Amend 29 to License R-28,renewing License for 20 Yrs ML20138L5571980-04-0202 April 1980 Application to Amend License R-28,authorizing Conversion from High to Low Enriched U Fuel ML20148D8081978-10-13013 October 1978 Amend 26 to Facil Oper Lic R-28 Revising Tech Specs to Auth Pwr Level for Ford Nuc Reactor When 10-plate Fuel Assemblies from Psu Res Reactor Are Utilized in E,W, & Fringe Locations of Reactor Core ML20148C7931978-10-12012 October 1978 Amend 25 to License R-28,revising Tech Specs to Authorize Possession of Intermetallic U Aluminide & U Oxide (U-308) Cermet Fuels & U-aluminum Alloy Fuel & Delete Cold Sump Alarm 1998-09-17
[Table view] |
Text
_ _ _ _ _ _ . .
e' THE UNIVERSITY OF MICHIG AN MICHIGAN M E MORI AL-PHO ENIX PROJECT l OFFICE OF THE DimECTOR PHOENIX MEMORI AL LABORATORT FMEN3 4 313) 764 8253 NORTH CAMPUS ANN ARSOR. MICHIG AN ASSOS Septembcr 18, 1985
. Docket.50-2 License R-28 United States Nuclear Regulatory Commission Harold Denton, Director Division of Reactor Licensing Washington, D.C. 20555 Gentlemen:
The University of Michigan requests that Ford Nuclear Reactor Technical Specifications, page 9, section 3.1, specification (5) be changed as follows:
(5) The reactor shall be subcritical by at least 0.025 delta K/K during fuel loading changes.
A revised page 9 is enclosed for incorparation in our Technical Specifications.
In our license renewal request, originated on November 30, 1984, the shutdown margin relative to the cold, xenon free critical condition with all three shim safety rods inserted was changed from 0.03 delta K/K to 0.025 delta K/K (page 9, section 3.1, specification (1)) . The minimum subcritical reactivity for fuel movement is the minimum shutdown margin with all rods inserted. It was an oversight on our part that we did not request a concurrent change in specification (5) reactivity to 0.025 delta K/K.
i Sincerely, William Kerr, Director Michigan Memorial-Phoenix Project Enclosure WK/sv Subscribed and sworn before me, this)JL day of feple3@eg ig_8,.f5 a Notary8g9240243 in and for Washtenaw Publi: BM9 i Michioan, County, PDR ADN 2 P PDR NOTARY PUBLIC MYComrnission expires _Jy -n\
..