Amends 190 & 173 to Licenses DPR-70 & DPR-75,respectively, Changing TSs 3/4.3.3.1 & 3/4.7.6 to Reflect CR Design
ML20134J980
Person / Time
Site: Salem  
Issue date: 02/06/1997
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Public Service Electric & Gas Co, Philadelphia Electric Co, Delmarva Power & Light Co, Atlantic City Electric Co
Shared Package
ML20134J983 List:
References
DPR-70-A-190, DPR-75-A-173 NUDOCS 9702130051
Download: ML20134J980 (34)


Text

__

[lA 4

UNITED STATES

}

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 30666 4 001

\\..... j/

~

PUBLIC SERVICE ELECTRIC & GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPANY AILANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-272 SALEM NUCLEAR GENERATING STATION. UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.190 License No. DPR-70 1.

The Nuclear Regulatory Commission (the Commission or the NRC) has found that:

A.

The application for amendment filed by the Public Service Electric &

Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the licensees) dated June 10, 1996, as supplemented June 24, July 1, August 13, September 20, and October 17, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I;

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-70 is hereby amended to read as follows:

9702130051 970206 DR ADOCK 0500 2

(2) Technical Soecifications and Environmental Protection Plan The Technical Specifications contained in Appendices A and B, as revised through Amendment No.190, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance, to be implemented within 30 days.

FOR THE NUCLEAR REGULATORY COMMISSION t

ohp F. Stolz, Diregtc r r4 ject Directorate T-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: February 6, 1997 1

i

ATTACHMENT TO LICENSE AMENDMENT NO.190 FACILITY OPERATING LICENSE NO. DPR-70 DOCKET NO. 50-272 Revise Appendix A as follows:

Remove Paoes Insert Paaes 3/4 3-36a 3/4 3-36a 3/4 3-37 3/4 3-37 3/4 3-38a 3/4 3-38a 3/4 7-18 3/4 7-18 3/4 7-19 3/4 7-19 3/4 7-20 3/4 7-20 3/4 7-21 3/4 7-21 B 3/4 3-2 B 3/4 3-2 B 3/4 7-5 B 3/4 7-5 B 3/4 7-Sa B 3/4 7-5b B 3/4 7-5c

~

I

i i

TABLE 3.3-6 (Continued)

RADIATION MONITORING INSTRUMENTATION i

t MINIMUM i

CHANNELS APPLICABLE' ALARM / TRIP MEASUREMENT INSTRUMENT OPERABLE MODES SETPOINT RANGE ACTION l

2.

PROCESS MONITORS t

i

b. Noble Gas Effluent Monitors
1) Medium Range Auxiliary 1

1,2,3&4 s3.0x102pCi/cm 10-8-10'uCi/cm' 23 f

3 Building Exhaust System (Alarm only)

[

(Plant Vent) i

2) High Range Auxiliary 1

1,2,3&4 s1.0x10r Ci/cm 3

p 10~'-105 3

pCi/cm 23 Building Exhaust System (Alarm only)

(Plant Vent)

3) Main Steamline 1/

1,2,3&4 s10 mR/hr 1-10* mR/hr 23 Discharge (Safety MS Line (Alarm only) l Valves and Atmospheric Steam Dumps) h

4) Condenser Exhaust 1

1,2,3&4 s1.27x10' cpm 1-10' cpm 23

}

System (Alarm only) 3.

CONTROL ROOM i

i cpm 24 h

a. Air Intake -

2/ Intake ##

2 s2.48x10 cpm 10'-107 Radiation Level i-

    1. Control Room air intakes shared between Unit 1 and 2.

t

    • ALL MODES and during movement of irradiated fuel assemblies and during core alterations.

[

t SALEM - UNIT 1 3/4 3-36a Amendment No.190 l

[

TABLE 3.3-6 (Continued)

TABLE NOTATION ACTION 19 - With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, perform area surveys of the monitored area with portable monitoring instrumentation at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

ACTION 20 - With the number of channels OPERABLE less than required by the

{

Minimum Channels OPERABLE requirement, comply with the ACTION requirements of Specification 3.4.6.1.

ACTION 22 - With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, comply with the ACTION requirements of Specification 3.9.9.

ACTION 23 - With the number of OPERABLE Channels less than required by the Minimum Channels OPERABLE requirements, initiate the preplanned alternate method of monitoring the appropriate parameter (s),

within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, and:

1) either restore the inoperable Channel (s) to OPERABLE status within 7 days of the event, or 2) prepare and su'>mit a Special Report to the Commission pursuant to Specification 6.9.2 within 14 days following the event outlining the action taken, the cause of the inoperability and the plans and schedule for restoring the system to OPERABLE status.

ACTION 24 - With the number of channels OPERABLE one less than required by the Minimum Channels OPERABLE requirement, restore the inoperable channel (s) to OPERABLE status within 7 days or initiate and maintain operation of the Control Room Emergency Air Conditioning System (CREACS) in the pressurization or recirculation mode of operation.

CORE ALTERATIONS and movement of irradiated fuel assemblies will be suspended during operation in the recirculation mode.

With no channels OPERABLE in a Control Room air intake, immediately initiate and maintain operation of the CREACS in the pressurization or recirculation mode of operation.

CORE ALTERATIONS and movement of irradiated fuel assemblies will be suspended during operation in the recirculation mode.

SALEM - UNIT 1 3/4 3-37 Amendment No.190

TABLE 4.3-3 (Continued)

RADIATION MONITORING INSTRUMENTATION SURVEILLANCE REOUIREMENTS CHANNEL MODES IN WHICH CHANNELS SOURCE CHANNEL FUNCTIONAL SURVEILLANCE INSTRUMENT CHECKS CHECKS CALIBRATION TEST REQUIRED 2.

PROCESS MONITORS

b. Noble Gas Effluent Monitors
1) Medium Range Auxiliary S

M R

Q 1,

2, 3&4 Building Exhaust System (Plant Vent)

2) High Range Auxiliary S

M R

Q 1,

2, 3&4 Building Exhaust System (Plant Vent)

3) Main Steamline S

M R

Q 1,

2, 3&4 Discharge (Safety Valves and Atmospheric Dumps)

4) Condenser Exh. Sys.

S M

R Q

1, 2,

3 & 4 3.

CONTROL ROOM

a. Air Intake - Radiation Level S

M R

Q

    • ALL MODES and during movement of irradiated fuel assemblies and during core alterations.

SALEM - UNIT 1 3/4 3-38a Amendment No.190

PLANT SYSTEMS i

3/4.7.6 CONTROL ROOM EMERGENCY AIR CONDITIONING SYSTEM LIMITING CONDITION FOR OPERATION 3.7.6.1 The common control room emergency air conditioning system (CREACS)*

shall be OPERABLE with:

a.

Two independent air conditioning filtration trains (one from each unit) consisting of:

1.

Two fans and associated outlet dampers, 2.

One cooling coil, 3.

One charcoal adsorber and HEPA filter array, 4.

Return air isolation damper.

4 b.

All other automatic dampers required for operation in the pressurization or recirculation modes.

c.

The control room envelope intact.

4 APPLICABILITY:

ALL MODES and during movement of irradiated fuel assemblies and during CORE ALTERATIONS.

ACTION:

MODES 1, 2,

3, and 4 a.

With one filtration train inoperable, align CREACS for single filtration train operation within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, and restore the inoperable filtration train to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

b.

With CREACS aligned for single filtration train operation and with one of the two remaining fans or associated outlet damper inoperable, restore the inoperable fan or damper to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

c.

With the Control Room Envelope inoperable, restore the Control Room Envelope to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, d.

With one or both series isolation damper (s) on a normal Control Area Air Conditioning System (CAACS) outside air intake or exhaust duct inoperable, close the affected duct within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one isolation damper secured in the closed position or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. (Refer to ACTION 24 of Table 3.3-6.)

  • The CREACS is a shared system with Salem Unit 2 1

SALEM - UNIT 1 3/4 7-18 Amendment No.190

i I

l PLANT SYSTEMS LIMITING CONDITION FOR OPERATION (Continued) l

==================================================================

l e.

With one or both isolation damper (s) on an outside emergency air l

conditioning air intake duct inoperable, close the affected duct within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one isolation damper secured in the closed position and restore the damper (s) to OPERABLE status within 7 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

f.

With any isolation damper between the n2rmal CAACS and the CREACS inoperable, secure the damper in the closed position within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

MODES 5 and 6 or during movement of irradiated fuel assemblies and during CORE ALTERATIONS.

a.

With one filtration train inoperable, align CREACS for single filtration train operation within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, or suspend CORE ALTERATIONS and movement of irradiated fuel assemblies.

b.

With CREACS aligned for single filtration train operation with one of the two remaining fans or associated outlet damper inoperable, restore the fan or damper to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, or suspend CORE ALTERATIONS and movement of irradiated fuel assemblies.

c.

With two filtration trains inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies, d.

With the Control Room Envelope inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies, e.

With one or both series isolation damper (s) on a normal CAACS outside air intake or exhaust duct inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies until the affected duct is closed by use of at least one isolation damper secured in the closed position. (Refer to ACTION 24 of Table 3.3-6.)

f.

With one or both series isolation damper (s) on an outside emergency air conditioning air intake duct inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies until the affected duct is closed by use of at least one isolation damper secured in the closed position.

To resume CORE ALTERATIONS or movement of irradiated fuel ass emblies, at least one emergency air l

intake duct must be operable on each unit.

l g.

With any isolation damper betweet the CAACS and the CREACS i

inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies until ihe damper is closed and secured in the closed position.

l SALEM - UNIT 1 3/4 7-19 Amendment No.190

I

\\

l 1

PLANT SYSTEMS l

SURVEILLANCE REQUIREMENTS 4.7.6.1 Each control room emergency air conditioning system filtration train shall be demonstrated OPERABLE:

At least once per 31 days by initiating flow through the HEPA filter a.

and charcoal adsorber train (s) and verifying that the train (s) i operates with each fan operating for at least 15 minutes.

b.

At least once per 18 months or prior to return to service (1) after any structural maintenance on the HEPA filter or charcoal adsorber housings, or (2) following painting, fire or chemical release in any ventilation zone communicating with the system, by:

1.

Verifying that the charcoal adsorbers remove a99% of a halogenated hydrocarbon refrigerant test gas when they are tested in-place while operating the ventilation system at a flow rate of 8000 cfm i 10%.

2.

Verifying that the HEPA filter banks remove a99% of the DOP when they are tested in-place while operating the ventilation system at a flow rate of 8000 cfm i 10%.

3.

Verifying within 31 days after removal that a laboratory analysis of a carbon sample from one of the charcoal adsorbers demonstrates a removal efficiency of a99% for radioactive methyl iodide when the sample is tested at 30*C, 95% relative humidity, After every 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> of charcoal adsorber operation by verifying c.

within 31 days after removal that a laboratory analysis of a carbon sample obtained from a test canister demonstrates a removal efficiency of a 99% for radioactive methyl iodide when the sample is tested at 30*C, 95% relative humidity.

d.

At least once per 18 months by:

1.

Verifying that the pressure drop across the combined HEPA filter and charcoal adsorber bank is s 3.5 inches water gauge while operating the ventilation system at a flow rate of 8000 cfm 1 10%.

2.

Verifying that on a safety injection test signal or control room intake high radiation test signal, the system automatically actuates in the pressurization mode by opening the outside air supply and diverting air flow through the HEPA filter and charcoal i

adsorber bank.

3.

Verifying that the system can maintain the control room at a positive pressure a 1/8" water gauge relative to the adjacent areas during system operation with makeup air being supplied through the HEPA filters and charcoal adsorbers at the design i

I makeup flow rate of s 2200 cfm.

l SALEM - UNIT 1 3/4 7-20 Amendment No.190 j

l

-~

. - ~. -.. _ _ _ _. _ _.

___m_._

.-._--_..__._.._._.__._._...___-m.-.__

t i

f PLANT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued) 4.

Verifying that on a manual actuation signal, the system will actuate to the required pressurization or recirculation operating mode.

l S.

Verify each CREACS train has the capability to remove the assumed l

heat load.

After each complete or partial replacement of a HEPA filter bank by e.

l verifying that the HEPA filter banks remove a 99% of the DOP when they l

are tested in-place while operating the filter system at a flow rate I

of 8000 cfm i 10%.

I f.

Af ter each complete or partial replacement of a charcoal adsorbers bank by verifying that the charcoal adsorberS remove a 99% of a halogenated l

hydrocarbon refrigerant test gas when they are tested in-place while operating the filter system at a flow rate of 8000 cfm i 10%.

{

i

[

i

(

I r

i r

i 1

I l

l I

l SALEM - UNIT 1 3/4 7-21 Amendment No.190 l

l ITg -tes-v 2 7

gyww

~

m y.

~

.-r>-

g--

+

INSTRUMENTATION BASES 3/4.3.3.1 RADIATION MONITORING INSTRUMENTATION (Continued)

CROSS REFERENCE - TABLES 3.3-6 AND 4.3-3 Func Rad Mon Rad Mon i

MD11 Number Function Area Monitors la 1R5/1R9 Fuel Storage Area lb 1R44 Containment Area i

Process Monitors 2a1 1R12A Containment Purge & Pressure / Vacuum Relief Gaseous Activity 1R41C Plant Vent Noble Gas Monitor may substitute for 1P.12A when the Purge & Pressure / Vacuum Relief Valves are open.

2a2 1R11A Containment Purge & Pressure / Vacuum Relief Air Particulate Activity 2b1 1R45B Medium Range Auxiliary Building Exhaust System (Plant Vent)

Noble Gas Effluent 2b2 1R45C High Range Auxiliary Building Exhaust System (Plant Vent)

Noble Gas Effluent 2b3 1R46 Main Steamline Discharge (Safety Valves and Atmospheric Dump Valves) Noble Gas Effluent 2b4 1R15 Condenser Exhaust System Noble Gas Effluent 3a 1 RIB-1 Unit 1 Control Room Intake Channel 1 (to Unit 1 Monitor)

{

2 RIB-2 Unit 1 Control Room Intake Channel 2 (to Unit 2 Monitor)

]

2 RIB-1 Unit 2 Control Room Intake Channel 1 (to Unit 2 Monitor) 1R1B-2 Unit 2 Control Room Intake Channel 2 (to Unit 1 Monitor) 1 Immediate action (s), in accordance with the LCO Action Statements, means that the required action should be pursued without delay and in a controlled manner.

3/4.3.3.2 MOVABUE INCORE DETECTORS The OPERABILITY of the movable incore detectors with the specified minimum complement of equipment ensures that the measurements obtained from use of this system accurately represent the spatial neutron flux distribution of the reactor core. The OPERABILITY of this system is demonstrated by irradiating each detector used and normalizing its respective output.

3/4.3.3.3 THIS SECTION DELETED 3 /4. 3. 3.4 THIS SECTION DELETED SALEM - UNIT 1 B 3/4 3-2 Amendment No.190 l

.._~-. ~

. -. - - - --. -. -. ~ -. - _. - - -. - - -

f

+

I PLANT SYSTEMS l

BASES l

3/4.7.5 FLOOD PROTECTION i

The limitation on flood protection ensures that facility protective j

actions will be taken and operation will be terminated in the event of flood connitions. The limit of elevation 10.5* Mean Sea Level is based on the

{

elevation above which facility flood control measures are required to provide j

protection to safety related equipment.

l l

i I

3/4.7.6 CONTROL ROOM EMERGENCY AIR CONDITIONING SYSTEM The OPERABILITY of the control room emergency air conditioning system l

(CREACS) ensures that 1) the ambient air temperature does not exceed the l

allowable temperature for continuous duty rating for the equipment and l

instrumentation cooled by this system and 2) the control room will remain habitable for operations personnel during and following all credible accident l

conditions.

The CREACS is a shared system between Unit 1 and 2 supplying a common l

Control Room Envelope (CRE). During emergency operation following receipt of

)

a Safety Injection or High Radiation actuation signal, for areas inside the l

CRE, one 100% capacity fan in each Unit's CREACS will operate in a l

pressurization mode with a constant amount of outside air supplied for continued CRE pressurization to 1/8" water gauge.

One fan from each train will automatically start upon receipt of an initiation signal, with one fan in each train in standby. A failure of one fan will result in the standby fan automatically starting.

Each CREACS train has two 100% capacity fans, such that any one of the fcur f ans is sized to provide the required flow for CRE pressurization to 1/8" water gauge positive pressure within the common CRE during an emergency.

A failure of one CREACS filtration train requires manual actions to properly reposition dampers in support of single filtration train operation.

To minimize control room radiological doses, the CREACS outside air is supplied from the non-accident unit's emergency air intake through the cross-connected supply duct (as determined by which unit received an accident l

signal). Outside air is mixed with recirculated air, passed through each CREACS filter bank (pre-filter, HEPA filter, and charcoal filter) and cooling coil, and distributed to the common CRE.

l l

CREACS will be manually initiated in the recirculation mode only in the j

j event of a fire outside the CRE, a toxic chemical release, delivery of l

Ammonium Hydroxide or testing.

l SALEM - UNIT 1 B 3/4 7-5 Amendment No.190

_m I

i PLANT SYSTEMS BASES l

l A significant contributor to this system's OPERABILITY are the dampers l

l which are required to actuate to their correct positions The following dampers are associated with the respective LCo*:

I' a.1 Fan outlet dampers:

1 (2 ) CAA15 and 1 (2) CAA16 These dampers ensure that the flow path for CREACS is operable and are l

l required to open upon CREACS initiation. The associated fan outlet l

damper will open on fan operation.

l a.4 Return air isolation damper:

1 (2) CAA17 When aligned for single train operation, the associated air return isolation damper will be administratively controlled in the open i

position.

l b.

Other dampers required for automatic operation in the pressurization or

{

recirculation modes:

Control Area Air Condit.oning System (CAACS) outside air intake isolation dampers:

1 (2 ) CAA4 0, 1 (2 ) CAA41, 1 (2) CAA43 and 1 (2) CAA4 5 The normally open outside air intake dampers 1(2)CAA40 and inlet plenum isralation dampers 1(2)CAA43 will be closed under emergency conditions.

J ine normally closed outside air intake dampers 1(2)CAA41 and inlet plenum isolation dampers 1(2)CAA45 are normally closed and remain closed i

under emergency conditions.

Control Area Air Conditioning Syrtem (CAACS) exhaust isolation dampers:

1(2) CAA18 and 1(2) CAA19.

i 1

1 These dampers are normally closed and are required to remain closed to prevent inleakage from the outside environment in the event of a toxic release.

Control Room Emergency Air Conditioning System (CREACS) air intake dampers: 1 (2 ) CAA4 8, 1 (2 ) CAA49, 1 (2) CAA50 and 1 (2) CAA51 CREACS outside air intake dampers are maintained closed during ner.nal and recirculation operation and are opened automatically upon initiation of CREACS pressurization. The control logic will automatically open the CREACS air intake dampers fnethest from the radiation source based upon which Unit's Solid State Pro.;ection System (SSPS) or Radiation Monitoring System (RMS) signal is received.

l l

  • Operability of the CREACS requires that each of the Unit 2 dampers are also operable SALEM - UNIT 1 B 3/4 7-Sa Amendment No.190

i

(

PLANT SYSTEMS l

BASES I

CAACS and CREACS interface isolation dampers: 1 (2 ) CAA14 and 1 (2) CAA20 These two dampers are normally open and do not have associated redundant l

dampers. These dampers serve a boundary funcLion by isolating the l

CREACS from the CAACS during emergency operation of the CREACS.

Note: Dampers 1(2) CAA5, CAACS recirculation damper will receive an accident alignment signal to ensure proper accident configuration of CAACS. This damper, however, is not required for the OPERABILITY of CREACS as defined in the LCo.

l The control room envelope is considered intact and able to support operation of the CREACS when the emergency air conditioning system is capable of maintaining a 1/8" water gauge positive pressure with the control room boundary door (s) closed.

Filter testing will be in accordance with the applicable sections of i

ANSI N510 (1975) with the exception that laboratory testing of activated j

carbon will be in accordance with ASTM D3803 (1989).

TS Surveillance Requirement verifies that each fan is capable of operating for at least 15 minutes b/ initiating flow through the HEPA filter and charcoal adsorbers train (s) to ensure that the system is available in a l

standby mode.

1 Each CAACS normal air intake ductwork will have an additional radiation detector channel installed for a total of two detectors per intake. The two l

detector channels from Unit 1 and Unit 2 CAACS air intake provide input to common radiation monitor processors.

Each radiation monitor processor (one for 1R1B-1/1R1B-2 and one for 2R1B-1/2R1B-2) provides a signal to initiate CREACS in the pressurization mode should high radiation be detected. A minimum of one out of two detectors in either intake will initiate the pressurization mode. With two detector channels inoperable on a Unit, operation may continue as long as CREACS is placed inservice in the pressurization or recirculation mode.

Pressurization mode will be initiated after 7 days with one inoperable detector. Radiological releases during a l

fuel handling accident while operating in the recirculation mode could result in unacceptable radiation levels in the CRE since the automatic initiation capability has been defeated for high radiation due to isolation of the detectors. Therefore, movement of irradiated fuel assemblies or Core j

Alterations at either Unit will not be permitted when in the recirculation mode.

Immediate action (s), in accordance with the LCO Action Statements, means that the required action should be pursued without delay and in a controlled manner.

l l

i SALEM - UNIT 1 B 3/4 7-5b Amendment No.190

I l

PLANT SYSTEMS l

BASES The OPERABILITY of this system in conjunction with control room design provisions is based on limiting the radiation exposure to personnel occupying the control room to 5 rem or less whole body, or its equivalent. This limitation is consistent with the requirements of General Desig; Criterion 19 of Appendix "A", 10 CFR 50.

3/4.7.7 AUXILIARY BUILDING EXHAUST AIR FILTRATION SYSTEM The OPERABILITY of the auxiliary building exhaust air filtration system ensures that radioactive materials leaking from the ECCS equipment following a LOCA are filtered prior to reaching the environment. The operation of this system and the resultant effect on offsite dosage calculations was assumed in the accident analyses. ANSI N510-1975 should be used as a procedural guideline for surveillance testing.

3/4.7.8 SEALED SOURCE CONTAMINATION i

The limitations on removable contamination for sources requiring leak H

testing, including alpha emitters, is based on 10 CFR 70.39(c) limits for plutonium. This limitation will ensure that leakage from byproduct, source, and special nuclear material sources will not exceed allowable intake values, i

SALEM - UNIT 1 B 3/4 7-Sc Amendment No.190 l

pm cagg p

t UNITED STATES y

Ij NUCLEAR REGULATORY COMMISSION

~

e WASHINGTON, D.C. 2006&c001

\\...../

PUBLIC SERVICE ELECTRIC & GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPM1 ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-311 SALEM NUCLEAR GENERATING STATION. UNIT NO. 2 MENDMENT TO FACILITY OPERATING LICENSE Amendment No.173 License No. DPR-75 1.

The Nuclear Regulatory Commission (the Commission or the NRC) has found that:

A.

The application for amendment filed by the Public Service Electric &

Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the li'.ensees) dated l

June 10, 1996, as supplemented June 24, July 1, August 13, September 20, and October 17, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as emended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I;

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issur ce of this amendment is in accordance with 10 CFR Part 51 of the Commtssion's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-75 is hereby amended to read as follows:

. (2) Technical Specifications and Environmental Protection Plan l

The Technical Specifications contained in Appendices A and B, as revised through Amendment No.173, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance, to be implemented within 30 days.

FOR THE NUCLEAR REGULATORY COMMISSION b)Cf V) hylF.Stolz, Director J4 ject Directorate I-2' Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: February 6, 1997 l

. =.

ATTACHMENT TO LICENSE AMENDMENT NO.173 FACILITY OPERATING LICENSE NO. DPR-75 DOCKET NO. 50-311 Revise Appendix A as follows:

Remove Paaes Insert Paaes l

3/4 3-39a 3/4 3-39a 3/4 3-40 3/4 3-40 3/4 3-41a 3/4 3-41a 3/4 7-15 3/4 7-15 3/4 7-16 3/4 7-16 3/4 7-17 3/4 7-17 3/4 7-17a B 3/4 3-2 B 3/4 3-2 B 3/4 3-3 8 3/4 3-3 B 3/4 3-3a B 3/4 3-3a B 3/4 3-4 8 3/4 3-4 B 3/4 3-4a B 3/4 7-5 B 3/4 7-5 B 3/4 7-Sa B 3/4 7-5b B 3/4 7-Sc i

1

=

TABLE 3.3-6 (Continued)

RADIATION MONITORING INSTRUMENTATION MINIMUM CHANNELS APPLICABLE ALARM / TRIP MEASUREMENT INSTRUMENT OPERABLE MODES-SETPOINT RANGE ACTION 2.

PROCESS MONITORS

b. Noble Gas Effluent Monitors 3

8

1) Medium Range Auxilfery 1

1,2,3&4 s3.0x10 pCi/cm 10-10' #Ci/cm 26 Building Exhaust 5 ** m (Alarm only)

(Plant Vent)

2) High Range Auxiliary 1

1,2,3&4 s1. 0x10'pCi/cm' 10-8-10' pCi/cm' 26 Building Exhaust System (Alarm only)

(Plant Vent) 8

3) Main Steamline 1/

1,2,3&4 10 mR/hr 1-10 mR/hr 26 Discharge (Safety MS Line (Alarm only)

Valves and Atmospheric Steam Dumps)

4) Condenser Exhaust 1

1,2,3&4 s7.12x10'. cpm 1-10' cpm 26 System (Alarm only) 3.

CONTROL ROOM s2.48x10' cpm 10'-10' cpm 27

a. Air Intake -

2/ Intake ##

Radiation Level

    1. Control Room air intakes share d between Unit 1 and 2.
    • ALL MODES and during movement of irradiated fuel assemblies and during core alterations.

l SALEM - UNIT 2 3/4 3-39a Amendment No.173

i e

TABLE 3.3-6 (Continued)

TABLE NOTATION ACTION 23 - With the number of channels OPERABLE less than required by the Minimam Channels OPERABLE requirement, perform area surveys of the monitored area with portable monitoring instrumentation at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

ACTION 24 - With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, comply with the ACTION requirements of Specification 3.4.7.1.

ACTION 25 - With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, comply with the ACTION requirements of Specification 3.9.9.

ACTION 26 - With the number of OPERABLE Channels less than required 4

by the Minimum Channels OPERABLE requirements, initiate the preplanned alternate method of monitoring the appropriate parameter (s), within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, and:

1) either restore the inoperable Channel (s) to OPERABLE status within 7 days of the event, or 2) prepare and submit a Special Report to the Commission pursuant to Specification 6.9.2 within 14 days following the event outlining the action taken, the cause of the inoperability and the plans and schedule for restoring the system to OPERABLE status.

ACTION 27 - With the number of channels OPERABLE one less than required by the Minimum Channels OPERABLE requirement, restore the inoperable channel (s) to OPERABLE status within 7 days or initiate and maintain operation of the Control Room Emergency Air Conditioning System (CREACS) in the pressurization or recirculation mode of operation. CORE ALTERATIONS and movement of irradiated fuel assemblies will be suspended during operation in the recirculation mode.

With no channels OPERABLE in a Control koom air intake, immediately initiate and maintain operation of the CREACS in the pressurization or recirculation mode of operation.

CORE ALTERATIONS and movement of irradiated fuel assemblies will be suspended during eperation in the recirculation mode.

SALEM - UNIT 2 3/4 3-40 Amendment No.173 l

-. _. ~

- -. -..... =......... ~... ~ ~ ~ _

i i

TABLE 4.3-3 (Continued) i I

RADIATION MONI*IVRING INSTRUMENTATION SURVEILLANCE REOUIREMENTS

[

CHANNEL MODES IN WHICH CHANNELS SOURCE CHANNEL FUNCTIONAL SURVEILLANCE INSTRUMENT CHECKS CHECKS CALIBRATION TEST REQUIRED

}

2.

PROCESS MONI'1VRS L

b. Noble Gas Effluent Monitors f
1) Medium Range Auxiliary S

M R

Q 1,

2, 3& 4 Building Exhaust System t

(Plant Vent) r

2) High Range Auxiliary S

M R

Q 1,

2, 3&4 Building Exhaust System (Plant Vent)

3) Main Steamline S

M R

Q 1,

2, 3&4 i

Discharge (Safety f

Valves and Atmospheric

=

Dumps) 4

4) Condenser Exh. Sys.

S M

R Q

1, 2,

3&4 3.

CONTROL ROOM i

a. Air Intake - Radiation Level S

M R

Q L

e L

    • ALL MODES and during movement of irradiated fuel assemblies and during CORE ALTERATIONS.

t f

SALEM - UNIT 2 3/4 3-41a Amendment No.173 i

k i

- ~ -. _ _ _ _ ~ -

I l,

PLANT SYSTEMS 3/4.7.6 CONTROL ROOM EMERGENCY AIR CONDITIONING SYSTEM LIMITING CONDITION FOR OPERATION i

3.7.6 The common control room emergency air conditioning system (CREACS)

i a.

Two independent air conditioning filtration trains (one from each unit) consisting of:

1.

Two fans and associated outlet dampers, 2.

One cooling coil, 3.

One charcoal adsorber and HEPA filter array, 4.

Return air isolation damper.

b.

All other automatic dampers required for operation in the pressurization or recirculation modes.

c.

The control room envelope intact.

4 APPLICABILITY: ALL MODES and during movement of irradiated fuel assemblies and during CORE ALTERATIONS.

ACTION:

MODES 1, 2,

3, and 4 g

a.

With one filtration train inoperable, align CREACS for single filtration train operation within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, and restore the inoperable 4

filtration train to OPERABLE status within 30 days or be in at least 2

HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

i b.

With CREACS aligned for single filtration train operation and with one of the two remaining fans or associated outlet damper inoperable, restore the inoperable fan or damper to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

c.

With the Control Room Envelope inoperable, restore the Control Room I

Envelope to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

d.

With one or both series isolation damper (s) on a normal Control Area I

Air Conditioning System (CAACS) outside air intake or exhaust duct inoperable, close the affected duct within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one isolation d'mper secured in the closed position or be in at least

)

a HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. (Refer to ACTION 27 of Table 3.3-6.)

1 l

  • The CREACS is a shared system with Salem Unit 1 SALEM - UNIT 2 3/4 7-15 Amendment No.173 i

PLANT SYSTEMS LIMITING CONDITION FOR OPERATION (Continued) e.

With one or both isolation damper (s) on an outside emergency air conditioning air intake duct inoperable, close the affected duct within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> by use of at least one isolation damper secured in the closed position and restore the damper (s) to OPERABLE status within 7 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

f.

With any isolation damper between the normal CAACS and the CREACS inoperable, secure the damper in the closed position within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

MODES 5 and 6 or during movement of irradiated fuel assemblies and during CORE ALTERATIONS.

a.

With one filtration train inoperable, align CREACS for single filtration train operation within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />, or suspend CORE ALTERATIONS and movement of irradiated fuel assemblies.

b.

With CREACS aligned for single filtration train operation with one of the two remaining fans or associated outlet damper inoperable, restore the fan or damper to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, or suspend CORE ALTERATIONS and movement of irradiated fuel assemblies.

c.

With two filtration trains inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies.

d.

With the control Room Envelope inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies, e.

With one or both series isolation damper (s) on a normal CAACS outside air intake or exhaust duct inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies until the affected duct is closed by use of at least one isolation damper secured in the closed position.

(Refer to ACTION 27 of Table 3.3-6.)

f.

With one or both series isolation damper (s) on an outside emergency air conditioning air intake duct inoperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies until the affected duct is closed by use of at least one isolation damper secured in the closed position. To resume CORE ALTERATIONS or movement of irradiated fuel assemblies, at least one emergency air intake duct must be operable on each unit.

g.

With any isolation damper between the CAACS and the CREACS

..soperable, immediately suspend CORE ALTERATIONS and movement of irradiated fuel assemblies until the damper is closed and secured in the closed position.

SALEM - UNIT 2 3/4 7-16 Amendment No.173 l

1

PLANT SYSTEMS SURVEILLANCE REQUIREMENTS 4.7.6.1 The control room emergency air conditioning system shall be o

demonstrated OPERABLE:

At least once per 31 days by initiating flow through the HEPA filter a.

and charcoal adsorber train (s) and verifying that the train (s) operates with each fan operating for at least 15 minutes.

4 b.

At least once per 18 months or prior to return to service (1) after any structural maintenance on the HEPA filter or charcoal adsorber housings, or (2) following painting, fire or chemical release in any ventilation zone communicating with the system, by:

1.

Verifying that the charcoal adsorbers remove a 99% of a halogenated I

hydrocarbon refrigerant test gas when they are tested in-place while operating the ventilation system at a flow rate of 8000 cfm a

i 10%.

2.

Verifying that the HEPA filter banks remove a 99% of the DOP when they are tested in-place while operating the ventilation system at a flow rate of 8000 cfm i 10%.

3.

Verifying within 31 days after removal that a laboratory analysis of a carbon sample from one of the charcoal adsorbers demonstrates a removal efficiency of a 99% for radioactive methyl iodide when i

the sample is tested at 30'C, 95% relative humidity, c.

After every 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> of charcoal adsorber operation by verifying within 31 days after remeval that a laboratory analysis of a carbon sample obtained from a test canister demonstrates a removal efficiency 1

of a 99% for radioactive methyl iodide when the sample is tested at 30*C, 95% relative humidity, i

d.

At least once per 18 months by:

1.

Verifying that the pressure drop across the combined HEPA filter and charcoal adsorber bank is s 3.5 inches Water Gauge while operating the ventilation system at a flow rate of 8000 cfm i 10%.

4 2.

Verifying that on a safety injection test signal or control room j

intake high radiation test signal, the system automatically i

actuates in the pressurization mode by opening the outside air supply and diverting air flow through the HEPA filter and charcoal l

adsorber bank.

a 3.

Verifying that the system can maintain the control room at a positive pressure a 1/8" water gauge relative to the adjacent areas during system operation with makeup air being supplied throtigh the HEPA filters and charcoal adsorbers at the design makeup flow rate j

of.s 2200 cfm.

I SALEM - UNIT 2 3/4 7-17 Amendment No.173 l

. _ _ _ _ _ _ _. _. - _ _ _ _ _ _ - - _ _ _. _ _ _ _ _ _ _ _ = _ - -.

._=.._._._._._.._...m__

PLANT SYSTEMS SUAVEILLANCE REQUIREMENTS (Continued) 4.

Verifying that on a manual actuation signal, the system will actuate to the raquired pressurization or recirculation operating mode.

5.

Verify each CREACS train has the capability to remove the assumed heat load.

1 After each complete or partial replacement of a HEPA filter bank by e.

verifying that the HEPA filter banks remove a 99% of the DOP when they l

are tested in-place while operating the filter system at a flow rate of g

8000 cfm i 10%.

l l

f.

After each complete or partial replacement of a charcoal adsorber bank by verifying that the charcoal adsorbers remove a 99% of a halegenated hydrocarbon refrigerent test gas when they are tested in-place while operating the filter system at a flow rate of 8000 cfm i 10%.

l i

I 1

l l

1 l

l l

i i

l i

I SALEM - UNIT 2 3/4 7-17a Amendment No.173 l

~

-~

f i

INSTRUMENTATION j

BASES 3 /4. 3. 3.1 RADIATION MONITORING INSTRUMENTATION (Continued) 4 CROSS REFERENCE - TABLES 3.3-6 and 4.3-3 I

I T/B Table Instrument Description Acceptable RMs Item No.

Channels I

la Fuel Storage Area 2R5 or 2R9 lb Containment Area 2R44A and B 2ala Containment Gaseous Activity Purge &

2R12A or Pressure / Vacuum Relief Isolation 2R41A, B and pm a) 2alb Containment Gaseous Activity RCS Leakage 2R12A Detection 2a2a Containment Air Particulate Activity Purge &

2R11A Pressure / Vacuum Relief Isolation 2a2b Containment Air Particulate Activity RCS 2R11A Leakage Detection i

2b1 Noble Gas Effluent Medium Range Auxiliary 2R45B*

Building Exhaust System (Plant Vent) 2b2 Noble Gas Effluent High Range Auxiliary 2R45C*

Building Exhaust System (Plant Vent) 2b3 Noble Gas Effluent Main Steamline Discharge -

2R46 Safety Valves and Atmospheric Steam Dumps 2B4 Noble Gas Effluent Condenser Exhaust System 2R13 3a Unit 2 Control Room Intake Channel 1 (to Unit 2 RIB-1 2 Monitor)

Unit 2 Control Room Intake Channel 2 (to Unit 1 RIB-2 1 Monitor)

Unit 1 Control Room Intake Channel 1 (to Unit 1R1B-1 1 Monitor)

Unit 1 Control Room Intake Channel 2 (to Unit 2 RIB-2 2 Monitor)

(1)

The channels listed are required to be operable to meet a single operable channel for the Technical Specificiation's 'Mmimum Channels Operable

  • requirement.

(2)

For Mode 6, the serpoint applies to 2R41D using 2 a Background fmm 2R41 A. For Modes 1,2,3,4 & 5, the setpoint applies to 2R41D per Specification 3.3.3.9. The measurement range applies to 2R41 A and B which display in uCi/cc usmg the appropnate channel conversion factor form cpm to uCi/cc.

(3)

If 2R45 is out of service 2R41 may be used to meet the technical specificianon action requirement.

SALEM UNIT 2 B 3/4 3-2 Amendment No.173

INSTRUMENTATION BASES Immediate action (s), in accordance with the LCO Action Statements, means that the required action should be pursued without delay and in a controlled manner.

3/4.3.3.2 MOVABLE INCORE DETECTORS The OPERABILITY of the movable incore detectors with the specified minimum complement of equipment ensures that the measurements obtained from use of this system accurately represent the spatial neutron flux distribution of the reactor core. The OPERABILITY of this system is demonstrated by irradiating each detector used and normalizing its respective output.

For the purpose of measuring Fn(Z) or Fas, a full incore flux map is used.

Quarter-core flux maps, as defined in WCAP-8648, June 1976, may be used in recalibration of the excore neutron flux detection system, and full incore flux maps or symmetric incore thimbles may be used for monitoring the QUADRANT POWER TILT RATIO when one Power Range Channel is inoperable.

3/4.3.3.3 THIS SECTION DELETED 3/4.3.3.4 l

j l

THIS SECTION DELETED 3/4.3.3.5 REMOTE SHUTDOWN INSTRUMENTATION The OPERABILITY of the remote shutdown instrumentation ensures that sufficient capability is available to permit shutdown and maintenance of HOT STANDBY of the f acility from locations outside of the control room. This capability is required in the event control room habitability is lost and is consistent with General Design Criterion 19 of 10 CFR 50.

3/4.3.3.6 THIS SECTION DELETED 3/4.3.3.7 ACCIDENT MONITORING INSTRUMENTATION The OPERABILITY of the accident monitoring instrumentation ensures that sufficient information is available on selected plant parameters to monitor and assess these variables following an accident. This capability is consistent with the Recommendations of Regulatory Guide 1.97, " Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant Conditions During and Following an Accident," December 1975 and NUREG-0578, "TMI-2 Lessons Learned Task Force Status Report and Short-Term Recommendations."

SALEM - UNIT 2 B 3/4 3-3 Amendment No.173

l INSTRUMENTATION BASES 3/4.3.3.8 RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION 1

The radioactive liquid effluent instrumentation is provided to monitor and i

control, as applicable, the releases of radioactive materials in liquid effluents during actual or potential releases of liquid effluents. The alarm / trip setpoints for these instruments shall be calculated and adjusted in accordance with the procedures in the ODCM to ensure that the alarm / trip will occur prior to exceeding the limits of 10 CFR Part 20. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50. The purpose of tank level indicating devices is to assure the detection and control of leaks that

{

if not controlled could potentially result in the transport of radioactive materials to UNRESTRICTED AREAS.

CROSS REFERENCE - TABLES 3.3-12 and 4.3-12 1

T/S Table Instrument Description Acceptable RMS Item No.

Channels la Liquid Radwaste Effluent Line Gross Activity 2R18 1

lb Steam Generator Blowdown Lines Gross Activity 2R19A,B,C, j

and D*

2a Containment Fan Coolers - Service Water Line 2R13A, B and Discharge Gross Activity C*

2b Chemical Waste Basin Line Gross Activity R37 d)

The channels hsted are required to be operable to meet a single operable channel for :he Techr.ical Specification's *Mmimum Channels Operable

  • requirement.

3 /4. 3. 3. 9 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION The radioactive gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents during actual or potential releases of gaseous effluents. The alarm / trip setpoints for these instruments shall be calculated and adjusted in accordance with the procedures in the ODCM to ensure that the alarm / trip will occur prior to exceeding the limits of 10 CFR Part 20. This instrumentation also includes provisions for monitoring (and controlling) the concentrations of potentially explosive gas mixtures in the waste gas holdup system. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.

SALEM - UNIT 2 B 3/4 3-3a Amendment No. 173

O INSTRUMENTATION BASES CROSS REFERENCE - TABLES 3.3-13 and 4.3-13 T/s Table Instrument Description Acceptable RMS Iteen No.

Channels la Waste Gas Holdup System Noble Gas Activity 2R41A, B and DUC) 2a Containment Purge and Pressure - Vacuum 2R12A or 2R41A, Relief Noble Gas Activity B and D"*)

3a Plant Vent Header System Noble Gas Activity 2R16 or 2R41A, B and D"")

(1)

The channels listed are required to be operable to meet a single operable channel for the Technical Specification's 'Mmimum Channels Operable" requirement.

(2) 2R41D is the setpoint channel. 2R41 A and 2R41B are the measurement channels.

3 /4. 3. 4 TURBINE OVERSPEED PROTECTION This specification is provided to ensure that the turbine overspeed protection instrumentation and the turbine speed control valves are OPERABLE and will protect the turbine from excessive overspeed.

Protection from turbine excessive overspeed is required since excessive overspeed of the turbine could generate potentially damaging missiles which could impact and damage safety-related components, equipment or structures.

The overspeed protection instrumentation consists of five solenoid valves and one trip mechanism which can be grouped into three independent systems. These aret 1.

Mechanical Overspeed Trip The mechanical overspeed trip valve will dump the autostop oil. The dump of the autostop oil will open the oil operated interface valve to dump the emergency electro-hydraulic trip fluid.

2.

Electrical Overspeed Trip The electrically sensed overspeed will trip two solenoid valves either of which will dump the autostop oil. The dump of the autostop oil will open the oil operated interface valve to dump the emergency electro-hydraulic trip fluid. The solenoid valves associated with the electrical overspeed are also energized by the various generator protections trips.

Salem Unit 2 B 3/4 3-4 Amendment No.173 T~

~

INSTRUMENTATION BASES 1

The dump of the autostop oil will actuate a solenoid to dump the emergency electro-hydraulic trip fluid. This solenoid serves as a backup for both the mechanical and electrical overspeed trips.

The I

backup solenoid is also energized by the various generator protections trips.

3.

Overspeed Protection Controller Either of the two overspeed protection control solenoid dump valves will dump the control electro-hydraulic trip fluid from the governor and intercept valves. When turbine speed decreases, and the oversreed condition clears, the signal is removed and the governor and intercept valves reopen.

Salem Unit 2 turbine is operated at full time, full are admission. To prevent excessive steam flow induced cyclic stresses of the control stage blading, perform turbine valve testing in accordance with manufacturer's recommendations.

During normal power operation, turbine valve testing is performed at a frequency consistent with the methodology presented in WCAP-11525, "Probabilistic Evaluation of Reduction in Turbine Valve Test Frequency." This report evaluates the contribution of failure or unavailability of the turbine valve safety function to the probability that the turbine will overspeed and eject a missile.

It concludes that extended intervals between turbine valve functional tests can be achieved without exceeding the NRC acceptance criteria for the probability of a turbine missile ejection incident.

Factors which affect the selected valve test interval include low pressure turbine rotor type and inspection interval; turbine valve type, arrangement and overspeed control; and secondary side water chemistry.

Salem Unit 2 B 3/4 3-4a Anendment No.173

__________m i

o l

PLANT SYSTEMS 1

BASES t

l

\\

3/4.7.5 FLOOD PROTECTION l

The limitation on flood protection ensures that facility protective l

actions will be taken and operation will be terminated in the event of flood l

conditions. The limit of elevation 10.5' Mean Sea Level is based on the 1

^

elevation above which facility flood control measures are required to provide protection to safety-related equipment.

3/4.7.6 CONTROL ROOM EMERGENCY AIR CONDITIONING SYSTEM The OPERABILITY of the control room emergency air conditioning system (CREACS) ensures that 1) the ambient air temperature does not exceed the allowable temperature for continuous duty rating for the equipment and instrumentation cooled by this system and 2) the control room will remain habitable for operations personnel during and following all credible accident conditions.

The CREACS is a shared system between Unit 1 and 2 supplying a common control Room Envelope (CRE).

During emergency operation following receipt of a Safety Injection or High Radiation actuation signal, for areas inside the CRE, one 100%. capacity fan in each Unit's CREACS will operate in a pressurization mode with a constant amount of outside air supplied for continued CRE pressurization to 1/8" water gauge. One fan from each train will automatically start upon receipt of an initiation signal, with one fan in each train in standby. A failure of one fan will result in the standby fan automatically starting.

Each CREACS train has two 100% capacity fans, such that any one of the four fans is sized to provide the required flow for CRE pressurization to 1/8" water gauge positive pressure within the common CRE during an emergency.

A failure of one CREACS filtration train requires manual actions to properly reposition dampers in support of single filtration train operation.

To minimize control room radiological doses, the CREACS outside air is supplied from the non-accident unit's emergency air intake through the cross-connected supply duct (as determined by which unit received an accident signal). Outside air is mixed with recirculated air, passed through each CREACS filter bank (pre-filter, HEPA filter, and charcoal filter) and cooling coil, and distributed to the common CRE.

CREACS will be manually initiated in the recirculation mode only in the event of a fire outside the CRE, a toxic chemical release, delivery of Ammonium Hydroxide or testing.

SALEM - UNIT 2 B 3/4 7-5 Amendment No.173

PLANT SYSTEMS BASES A significant contributor to this system's OPERABILITY are the dampers which are required to actuate to their correct positions. The following dampers are associated with the respective LCO*:

I a.1 Fan outlet dampers:

1(2) CAA15 and 1(2) CAA16 These dampers ensure that the flow path for CREACS is operable and are required to open upon CREACS initiation. The associated fan outlet damper will open on fan operation.

i 1

a.4 Return air isolation damper:

1 (2) CAA17 i

when aligned for single train operation, the associated air return isolation damper will be administratively controlled in the open position.

b.

Other dampers required for automatic operation in the pressurization or recirculation modes:

1 Control Area Air Conditioning System (CAACS) outside air intake j

isolation dampers:

1 (2 ) CAA4 0, 1 (2 ) CAA41, 1 (2) CAA43 and 1 (2) CAA45 l

The normally open outside air intake dampers 1(2)CAA40 and inlet plenum isolation dampers 1(2)CAA43 will be closed under emergency conditions.

The normally closed outside air intake dampers 1(2)CAA41 and inlet plenum isolation dampers 1(2)CAA45 are normally closed and remain closed under emergency conditions.

Control Area Air Conditioning System (CAACS) exhaust isolation dampers:

1(2)CAA18 and 1(2)CAA19.

These dampers are normally closed and are required to remain closed to prevent inleakage from the outside environment in the event of a toxic release.

Control Room Emergency Air Conditioning System (CREACS) air intake dampers: 1 (2 ) CAA4 B, 1 (2 ) CAA4 9, 1 (2) CAA50 and 1 (2) CAA51 CREACS outside air intake dampers are maintained closed during normal and recirculation operation and are opened automatically upon initiation of CREACS pressurization. The control logic will automatically open the CREACS air intake dampers farthest from the radiation source based upon which Unit's Solid State Protection System (SSPS) or Radiation Monitoring System (RMS) signal is received.

  • Operability of the CRECS requires that each of the Unit i dampers are also operable SALEM - UNIT 2 B 3/4 7-5a Amendment No173

~..

- ~. -. _. - - - - -. -. -

-. - - -. - ~

4 e

}

PLANT SYSTEMS f

i BASES

}

=======================....==.............................................

j CAACS and CREACS interface isolation dampers: 1(2) CAA14 and 1(2) CAA20 These two dampers are normally open and do not have associ ated redundant dampers. These dampers serve a boundary function by isolating the l

CREACS from the CAACS during emergency operation of the CREACS.

I j

Note: Dampers 1(2) CAA5, CAACS recirculation damper will receive an accident i

alignment signal to ensure proper accident configuration of CAACS. This damper, however, is not required for the OPERABILITY of CREACS as defined in j

the LCO.

The control room envelope is considered intact and able to support operation of the CREACS when the emergency air conditioning system is capable cf maintaining a 1/8" water gauge positive pressure with the control room J

boundary door (s) closed.

Filter testing will be in accordance with the applicable sections of i

ANSI N510 (1975) with the exception that laboratory testing of activated carbon will be in accordance with ASTM D3803 (1989).

1 TS Surveillance Requirement verifies that each fan is capable of operating for at least 15 minutes by initiating flow through the HEPA filter and charcoal adsorber train (s) to ensure that the system is available in a j

standby mode.

Each CAACS normal air intake ductwork will have an additional radiation detector channel installed for a total of two detectors per intake.

The two j

detector channels from Unit 1 and Unit 2 CAACS air intake provide input to common radiation monitor processors. Each radiation monitor processor (one for 1 RIB-1/1R1B-2 and one for 2R1B-1/2R1B-2) provides a signal to initiate CREACS in the pressurization mode should high radiation be detected. A minimum of one out of two detectors in either intake will initiate the pressurization mode, With two detector channels inoperable on a Unit, operation may continue as long as CREACS is placed inservice in the pressurization or recirculation mode.

Pressurization mode will be initiated after 7 days with one inoperable detector. Radiological releasec during a fuel handling accident while operating in the recirculation mode could result in unacceptable radiation levels in the CRE since the automatic initiation capability has been defeated for high radiation due to isolation of the detectors. Therefore, movement of irradiated fuel assemblies or Core Alterations at either Unit will not be permitted when in the recirculation mode.

Immediate action (s), in accordance with the LCO Acrion Statements, means i

that the required action should be pursued without delay and in a controlled manner.

SALEM - UNIT 2 B 3/4 7-5b Amendment No.173

PLANT SYSTEMS 1

BASES r

==================================================================

The OPERABILITY of this system in conjunction with control room design provisions is based on limiting the radiation exposure to personnel occupying i

the control room to 5 rem or less whole body, or its equivalent. This limitation is consistent with the requirements of General Design Criterion 19 4

of Appendix "A", 10 CFR Part 50.

3/4.7.7 AUXILIARY BUILDING EXHAUST AIR FILTRATION SYSTEM The flowrates specified for surveillance testing correspond to the i

maximum design flow for the charcoal adsorber. This is the limiting condition for system performance under accident conditions. Testing at this flow assures that the charcoal adsorber removal efficiency, and the system bypass leakage are within the assumed values of the accident analysis. Operation at lower flowrates is conservative with respect to the accident analysis assumptions.

3/4.7.8 SEALED SOURCE CONTAMINATION The limitations on removable contamination for sources requiring leak testing, including alpha emitters, is based on 10 CFR 70.39(c) limits for plutonium. This limitation will ensure that leakage from byproduct, source, and special nuclear material sources will not exceed allowable intake values.

Sealed sources are classified into three groups according to their use, with surveillance requirements commensurate with the probability of damage to a source in that group.

Those sources which are frequently handled are required to be tested more often than those which are not.

Sealed sources which are continuously enclosed within a shielded mechanism (i.e., sealed sources within radiation monitoring or boron measuring devices) are considered to be stored and need not be tested unless they are removed from the shielded mechanism.

4 SALEM - UNIT 2 B 3/4 7-Sc Amendment No.173