_-

3.13 SECONDARY COOLANT SYSTEM ACTIVITY Applicability Applies to the limiting conditions for operation when reactor coolant system pressure is greater than 300 psig or Tavg is greater than 200 F.

Objective To limit the inventory of activity in the secondary system.

Specification 3.13.1 The specific activity of the secondary coolant system shall be

< 0.10 p Ci/ gram DOSE EQUIVALENT I-131.

3.13.2 With the specific activity of the secondary coolant system > 0.10p Ci/ gram DOSE EQUIVALENT I-131, be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

Bases The limitations on secondary system specific activity ensure that the resultant off-site radiation dose will be limited to a small fraction of 10 CFR Part 100 limits-in the event of a steam line rupture.

This dose includes the effects of a coincident 1.0 GPM primary-to-secondary tube leak in the steam generator of the affected steam line.

hhh DO K

[

P Amendment No.

3-58 v--

7__m

_.__._..__,._.,.,.__y

,y-r_.,

__.,,n

._, y..

3.___.~.,-_-.-.

.a='

g TABLE-4.1-3 Cent'd.

@g Item-Check Frequency 5

4.

Spent Fuel Pool Water Sample Boron concentration Monthly and after each makeup

~

5.

Secondary Coolant System Activity Isotopic analysis for DOSE At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> when

'g EQUIVALENT I-131 concentration reactor coolant system pressure is greater than 300 psig or Tav y

is greater than 200 F g

6.

Boric Acid Mix Tank or Reclaimed Boric Boren concentration Twice weekly ***

Acid Tank

7. -

Deleted i

8.

Deleted 9.

Deleted 10.

Sodium Hydroxide Tank Concentration.

Quarterly and after each makeup 11.

Deleted l12.

Deleted Until the specific activity of tne primary coolant system is restored within its limits.

Sample to be taken after a minimum of 2 EFPD and 20 days of POWER OPERATION have elapsed since the reactor was last subscritical for 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or longer.

4 Deleted.