l l

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSCE 374ot 1630 Chestnut Street Tower II July 9, 1985 BLRD-50-438/81-56 BLRD-50-439/81-58 U.S. Nuclear Regulatory Commission Region II Attn:

Dr. J. Nelson Grace, Regional Administrator 101 Marietta Street, NW, Suite 2900

\\

Atlanta, Georgia 30323 J

(

Dear Dr. Grace:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - REACTOR COOLANT SYSTEM SUPPORTS AND RESTRAINTS - BOLT TORQUES - BLRD-50-438/81-56, BLRD-50-439/81 FINAL REPORT S

We wish to correct a typographical error in our final report to you o the subject matter dated June 25, 1985. The figure for the minimum specified yield strength in the third line under the heading Safety Implication Ehoule C

read 150 ksi and not the misprinted 180 ksi.

Please correct your reco3 s d

accordingly.

a If you have any questions concerning this matter, please set in touchemith R. H. Shell at FTS 858-2688.

O Very truly yours, TENNESSEE VALLEY AUTHORITY d?FtAd

. W. Hufham, Manager Licensing and Risk Protection ec:

Mr. James Taylor, Director l

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. H. B. Barkley 205 Plant Project Services P.O. Box 10935 Lynchburg, Virginia 24505 RecordL Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 8508140109 050709 PDR ADOCK 05000430 S

PDR An Equal Opportunity Employer s