_ ._.... . _ _ . _. .. __ _ _ _ _ _ _ . .. _ . _ _ _ _ _ _ _ _ _ _ __

, RTS Instrumentation 3.3.1 l

Table 3.3.1-1 (page 5 of 8)

Reactor Trip System Instr w i..Jtion APPLICABLE MODES OR OTHER

, SPECIFIED tEQUIRED SURVEILLANCE ALLOWABLE TRIP l FUNCTION CONDITIONS CHANNELS CONDITIONS REQUIREMENTS VALUE SETPOINT l

14. Turbine Trip
a. Low Fluid 011 1(l) 3 o SR 3.3.1.10 t 500 psig a 580 psig i Pressure SR 3.3.1.16
b. Turbine Stop 1(II 4 P SR 3.3.1.10 t %.7% t %.7%

Valve closure SR 3.3.1.14 open open

15. Safety 1,2 2 trains o SR 3.3.1.13 NA NA l

-Injection (SI)

Input from Engineered Safety Feature Actuation System (ESFAS)

16. Reactor Trip System Interlocks
a. Intermediate 2(d) 2 R SR 3.3.1.11 t 6E-11 amp t 1E-10 anp Range Neutron SR 3.3.1.12 Flux, P 6
b. Low Power 1 1 per S SR 3.3.1.5 NA NA Reactor Trips train Block, P 7
c. Power Range 3 4 S SR 3.3.1.11 s 50.3% RTP s 48% RTP Neutron Flux, SR 3.3.1.12 P-8
d. Power Range 4 S SR 3.3.1.11 s 52.3% RTP 5 50% RTP Neutron Flux, 1 SR 3.3.1.12 P-9
e. Power Range 4 R SR 3.3.1.11 (l,m) (l,m)

Neutron Flux, 1,2 SR 3.3.1.12 P-10 and input to P 7 2 S SR 3.3.1.10 s 12.3% s 10%

f. Turbine Inpulse 1 SR 3.3.1.12 Inpulse Impulse Pressure, P 13 Pressure Pressure Equivalent Equivalent turbine turbine (continued)

(d) Below the P-6 (Intermediate Range Neutron Flux) interlocks.

(j) Above the P 9 (Power Range Neutron Flux) interlock.

(L) For the P-10 input to P-7, the Allowable Value is 512.3% RTP and the Trip Setpoint is 510% RTP.

(m) For the Power Range Neutron Flux, P-10, the Allowable Value is t 7.7% RTP and the Trip Setpoint is l

t 10% RTP.

l l

l Vogtle Units 1 and 2 3.3-18 Amendment No. 96 (Unit 1) i Amendment No. 74 (Unit 2) 9701210562 970110 PDR ADOCK 05000424 P pp