i e no.a no..
o i.
UNITED STATES Guv'ERNMENT Memorandum To
- Files DAT E: November 23, 1960
( _W >
j FROM
, j, bne i
sunjEcr: MALLINCKRODT CHB 4ICAL WORKS APPLICATION FOR AUTHORIZATION TO INCINERATE - LICENSE NO. SM4 DOCKST NO. 70-36 L&R:JJL ANALYSIS AND FINDINGS By application dated October 6,1960, as supplemented November 8, and 16, 1960, Mallinckrodt Chemical Works requests amend-ment to their special nuclear material license No. SMi-33 to authorize the use of an incinerator for concentrating uranium containing trash prior to chemical recovery of the U-235 con-tent.
The trash will consist of filters, rags, etc., and floor mop waters. Batch limitation to 350g U-235 will be under technical supervisory control. 1he pot util be cleaned after each fired i
batch. Flue gas will be monitored and dust is controlled by plastic wrapping of filters prior to handling and firing.
Based on our review of the infomation submitted by the appli-cant, it is hereby determined that License SM(-33 may be amended to authorize the incineration activity.
APPROVED:
96W-
- 4. G. Delaneyf Chief, Nucles(p Materials Branch L
i 1-e s s.{
i g.,
. ~ ' _
a e'..., -