Partial Response to FOIA Request for 35 Specified Documents. Forwards Subj Documents.Documents 1,3,5-8,10,12-16,18,19,33, 34 & 35 Available in Pdr.Document 20 Available from ANS
Date released: 05/26/2020 Download: ML20133H069


Sanitized Response to NRC 840511 Ltr Re Violations Noted in Insp Rept 70-1113/83-28.Corrective Actions:Procedure Coi 002 Revised to Stipulate That All Control Limits Will Be Recalculated
ML20133H506
Person / Time
Site: 07001113
Issue date: 06/07/1984
From:
GENERAL ELECTRIC CO.
To:
References
FOIA-85-158
Download: ML20133H506 (3)
Sanitized Insp Rept 70-1113/83-28 on 830920-23.Noncompliance Noted:Failure to Adequately Reevaluate Control Chart Limits at Least Once Per Matl Balance Period & Failure to Establish Written Procedure Re Evaluating Limits
ML20133H481
Person / Time
Site: 07001113
Issue date: 10/28/1983
From: Mcalpine E, Richards B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
FOIA-85-158
Download: ML20133H481 (6)
Sanitized Notice of Violation from Insp on 830920-23
ML20133H456
Person / Time
Site: 07001113
Issue date: 10/31/1983
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
FOIA-85-158
Download: ML20133H456 (2)
Sanitized Ltr Forwarding Safeguards Insp Rept 70-1113/83-28 on 830920-23 & Notice of Violation
ML20133H421
Person / Time
Site: 07001113
Issue date: 10/31/1983
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: LONG J A
GENERAL ELECTRIC CO.
References
FOIA-85-158
Download: ML20133H421 (2)
Sanitized Insp Rept 70-1113/84-11 on 850730-0802.Violations Noted:Failure to Calculate Limits of Error Associated W/ U Dioxide Pellet Shipments & Failure to Organize Record Sys
ML20133H396
Person / Time
Site: 07001113
Issue date: 10/15/1984
From: Mcalpine E, Richards B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
FOIA-85-158
Download: ML20133H396 (8)
Sanitized Notice of Violation from Insp on 840730-0802
ML20133H382
Person / Time
Site: 07001113
Issue date: 10/18/1984
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
FOIA-85-158
Download: ML20133H382 (2)
Sanitized Ltr Forwarding Insp Rept 70-1113/84-11 on 840730- 0802 & Notice of Violation
ML20133H337
Person / Time
Site: 07001113
Issue date: 10/18/1984
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: LEES E A
GENERAL ELECTRIC CO.
References
FOIA-85-158
Download: ML20133H337 (2)
Insp Rept 70-1113/81-14 on 811012-16.Noncompliance Noted: Failure to Evaluate Measurement Control Data W/Appropriate Statistical Methods & Establish Written Procedures for Recording,Analyzing & Reporting Measurement Data
ML20133H304
Person / Time
Site: 07001113
Issue date: 11/02/1981
From: David Jones, Mcalpine E, Richards B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
FOIA-85-158
Download: ML20133H304 (4)
Notice of Violation from Insp on 811012-16
ML20133H285
Person / Time
Site: 07001113
Issue date: 11/04/1981
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
FOIA-85-158
Download: ML20133H285 (2)
Summary of 840710 Meeting W/Ge in Region II Ofc Re Denial of Violation Concerning Statistical Methods Used to Determine Measurement Control Limits.List of Attendees Encl.Safeguards Info Deleted (Ref 10CFR2.790 & 73.21)
ML20133H271
Person / Time
Site: 07001113
Issue date: 07/26/1984
From: Richards B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
FOIA-85-158
Download: ML20133H271 (8)
Sanitized Summary of 840710 Meeting W/Ge in Region II Ofc Re Denial of Violation Concerning Statistical Methods Used to Determine Measurement Control Limits
ML20133H094
Person / Time
Site: 07001113
Issue date: 07/30/1984
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: LONG J A
GENERAL ELECTRIC CO.
References
FOIA-85-158
Download: ML20133H094 (1)
Partial Response to FOIA Request for 35 Specified Documents. Forwards Subj Documents.Documents 1,3,5-8,10,12-16,18,19,33, 34 & 35 Available in Pdr.Document 20 Available from ANS
ML20133H065
Person / Time
Site: 07001113
Issue date: 06/21/1985
From: Felton J
NRC OFFICE OF ADMINISTRATION (ADM)
To: RATNER M G
RATNER, M.G.
References
FOIA-85-158
Download: ML20133H065 (1)