J December 17, 1996 MEMORANDUM T0:
James M. Taylor Executive Director for Operations FROM:
Roy P. Zimmerman Orig. signed by J. Roe foe i
Associate Director for Projects Office of Nuclear Reactor Regulation
SUBJECT:
NOVEMBER 1996 REPORT ON THE STATUS OF PUBLIC PETITIONS UNDER 10 CFR 2.206 The attached monthly report reflects the status of 10 CFR 2.206 petitions as of the end of November 1996. This report may not reflect changes in status that have occurred since petition managers submitted data on the November status. Attachment I gives the status of petitions before the Offices of Nuclear Material Safety and Safeguards, Nuclear Reactor Regulation, and Enforcement. Attachment 2 lists decisions before the Commission and the 4
d courts. Attachment 3 lists other sensitive matters which are for internal distribution only.
4 By issuing the monthly report on the status of pending 10 CFR 2.206 petitions, the staff is documenting its responsiveness to petitioners.
To enhance staff.. responsiveness to the public, those parts of the monthly report not of a sensitive nature will be placed in the Public Document Room and on.the< electronic bulletin. board system, making them readily accessible to the public.
~ ~ '
+
AttachInents:
- 1. ' Report on Stat'us'of Public Petitions Under 10 CFR 2.206 2., Decisions Pending Before the Commission and the Courts
-3. -Internal Distribution Only g
cck/atts:'J.L.Milhoa~n,,EDO R. L. Bangart, OSP H. L.: Thompson, EDO G. P. Caputo, 01 J. Blaha, EDO J. F. Cordes, Jr., OCAA
+
i
?
K. D. Cyr, OGC J. R. Goldberg, OGC F. J. Miraglia, NRR L. J. Chandler, OGC l
-C. J. Paperiello, NMSS Regional Administrators J. Lieberman, OE OCA E. Julian, SECY OPA CONTACT: Janet Kennedy, NRR 2
415-3267 Distribution:
(Central Files:
J. Roe (e)
G. Beveridge P.Lohaus P. Anderson /ED0 PUBLIC w/att 1 & 2 only (Att 3 is "NOT FOR EXTERNAL DISTRIBUTION")
k 1 l
B. McCabe E. Adensam (e)
F. Cameron /0GC A. Chaffee G. Deegan/NMSS R. Zimmerman M. Thadani C. Jamerson J. Kennedy 4
u r c.iw. c.,y.e this esci-ne, insic.t. in en. h m =c Copy without attachment / enclosure "E" = Copy with ett cha.nt/ neto ur. =r so copy DOCUMENT NAME:
P:\\206\\0EC96RPT.WP i
I 0FFICE LA:PD31 lE PM:PDVI-l l E NMSS:RMB lE DE E
- ADRQaNRR, lE j,
NAME C.Jamersorhl J. Kennedy E G.G.Beveridge J. Lieberman R.PA limmerman DATE 12/l&/96 7 12/ 10 /96 12/16/96(e) 12/r7/96(e) 12T'r7 /96 CR
- Le - (
(j OFFICIAL RECORD COPY (e) e-mail concurrenceQOiC-E oy.
q{p /7/
ik H %>d f
96122300 9 17 PDR ORG NE ED PDR
t uarg i
k UNITED STATES g
g j
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 3068H001
.,g*
December 17, 1996 MEMORANDUM TO:
James M. Taylor Executive Director for Operations FROM:
Roy P. Zimmerman
.rs 1
Associate Direc for Projects i
Office of Nuclea Reactor Regulation i
SUBJECT:
NOVEMBER 1996 REPORT ON THE STATUS OF PUBLIC PETITIONS UNDER 10 CFR 2.206 The attached monthly report reflects the. status of 10 CFR 2.206 petitions as of the end of November 1996. This report may not reflect changes in status that have occurred since petition managers submitted data on the November status. Attachment I gives the status of petitions before the Offices of j
Nuclear Material Safety and Safeguards, Nuclear Reactor Regulation, and i
Enforcement. Attachment 2 lists decisions before the Commission and the courts. Attachment 3 lists other sensitive matters which are for internal j
distribution only.
)
By issuing the monthly report on the status of pending 10 CFR 2.206 petitions, the staff is documenting its responsiveness to petitioners.
i To enhance staff responsiveness to the public, those parts of the monthly report not of a sensitive nature will be placed in the Public Document Room and on the electronic bulletin board system, making them readily accessible to j
the public.
Attachments:
1.
Report on Status of Public Petitions Under 10 CFR 2.206 2.
Decisions Pending Before the Commission and the Courts 3.
Internal Distribution only ec w/atts:
J. L. Milhoan, EDO R. L. Bangart, OSP H. L. Thompson, EDO G. P. Caputo, 01 J. Blaha, EDO J. F. Cordes, Jr., OCAA K. D. Cyr, OGC J. R. Goldberg, OGC F. J. Miraglia, NRR L. J. Chandler, OGC j
C. J. Paperiello, NMSS Regional Administrators J. Lieberman, OE OCA E. Julian, SECY OPA CONTACT: Janet Kennedy, NRR 415-3267
Report en Status of Public Petiticns Under 10 CFR 2.206 November 1996 i
Contents
- Page Facility Petitioner /EDO No.
h Vogtle Hobby and Mosbaugh/5836 1,26 Advanced Medical Systems, Inc.
Northeast Ohio Regional Sewer District /8663 2
All Power Reactors Blanch /9968 26 Advanced Medical Systems, Inc.
Northeast Ohio Regional Sewer District /10395 3
Oyster Creek Gunter and de Camp,Jr./10473 3 j
Georgia Tech and All Licensees Blockey-O'Brien/10598 5
l Millstone Ross/10600 7
Millstone Ross/15 8
Millstone Ross/16 26 Millstone Ross/17 26 Prairie Island Units 1 and 2 Bjoralt and Gunter/433 27 Millstone Galatis et al./603 9,28 Palisades Sinclair and Skavroneck/665 11 National Institutes of Health Ma and Zheng/721 13,28 Palisades Plant, Point Beach Units 1 and 2, and Arkansas Nuclear One, Units 1 and 2 Shillinglaw/872 15 Davis-Besse Toledo Coalition for Safe Energy, et al./886 17 Catawba Morris /GT96045 26 All Nuclear Power Plants Morris /GT96105 26 Maine Yankee Burt, Friends of the Coast /GT96181 27 t
Oyster Creek de Camp /GT96345 18 Westinghouse Electric Corporation Doyle/GT96400 18 4
St. Lucie, Units 1 and 2 Saporito et al./GT96445 26 Oyster Creek de Camp /GT96452 19 l
l Shieldalloy and Cypress Foote Bauman/GT96596 20 Maine Yankee and All Other Plants Using the RELAP Code for ECCS Analyses Sears /GT96659 21 Northern States Power Company Indopendent Florence Township /GT9669 Spent Fuel Storage Installation
/GT96670 21 Point Beach, Units 1 and 2 Duns, Wisconsin's Citizens' Utility Board /GT96774 22 Shieldalloy Bauman/GT96775 23 San Onofre Nuclear Generating Station Dwyer/GT96778 24 All Users of the VSC-24 Nuclear Waste Storage Cask Sinclair and Roemer/GT96801 24 Connecticut Yankee and Millstone Katz, Citizens Awareness Network /GT96919 24
- Includes Attachments 2 and 3.
i
i 1
i Report on Status of Public Petitions Under 10 CFR 2.206 i
Facility:
Magth Petitioners:
M. Hobby and A. Mosbaugh j
Date of Petition:
9/11/90 Director's Decision To 8e Issued by:
NRR Date Referred to Review Organization:
9/21/90 ED0 Number:
5836 P-90-009 l
OGC Number:
l Scheduled Completion Date:
12/31/96 i
Last Contact with Petitioner (s):
10/18/96 i
Petition Manager:
D. Wheeler Case Attorney:
M. Young /C. Barth 1
l Issues / Action Requested:
Take immediate action regarding alleged " illegal transfer" of operating licenses, repeated and i
willful violations of NRC requirements, and unsafe j
management practices at operating reactors.
{
Current Status:
An acknowledgment letter was issued on 10/23/90. The Director of the Office of Nuclear Reactor Regulation issued a partial Director's Decision on 4/23/93 i
l (N)-93-08). On 7/14/93, the Commission vacated the pa.tial Director's Decision and requested that a final d
Director's Decision await completion of a related hearing i
(CLI S3-15). On 2/18/94, the Atomic Safety and Licensing l
Board (ASLB) granted intervenor status to petitioner i
Mosbaugh, admitting him as a party in the license amendment proceeding concerning the proposed transfer of l
operating licenses from Georgia Power to Southern Nuclear j
Operating Company. The contention admitted encompasses l
some of the issues in the 2.206 petition. The hearing on the " illegal transfer" issue was held 1/4-13/95. The l
hearing on the final issue (an alleged misrepresentation of diesel generator test results) began on 4/17/95. On 2/1/96 the NRC issued a Board Notification, 96-01, to the petitioners' attorney advising them of pending actions.
i On 4/10/96, OGC telephoned the petitioner's legal counsel l
in the ASLB proceeding to provide a status update on the I
2.206 petition and inform the legal counsel that there 1
I were no new developments.
1 The hearings were completed and the final filings from all l
parties were submitted to the ASLB by 12/22/95. On 6/20/96 Georgia Power Company and intervenor Mosbaugh filed a joint motion informing the Board that they had arrived at a settlement "in principle" and asked the Board 1
to defer issuing any decision until 9/20/96. One of the l
conditions of the settlement was that the Board terminate j
l the proceedings without a decision. On 8/2/96, petitioner i i m
Mosbaugh filed a cithdrawal of his interventien and, on the same day, petitioner Mosbaugh and the licensee filed a j
joint motion requesting that the ASLB issue an order terminating the proceedings without issuing a decision.
I The ASLB issued an order on 8/16/96 dismissing the case without a decision. The staff received an extension for the scheduled completion date until 10/31/96. The staff received an extension in October 1996 until 11/30/96, and again in November 1996 to 12/31/96 to allow additional time for staff review of the draft Director's Decision.
On 7/1/96, 8/27/96, and 10/18/96, the staff telephoned petitioner Hobby's legal counsel to provide an update on the status of the petition.
Facility:
Advanced Nadical Syst
. Inc.
Petitioner:
Northeast Ohio Regional Sewer District (W. Schatz)
Date of Petition:
3/3/93 Director's Decision To Be Issued by:
NMSS Date Referred to Review Organization:
3/17/93 EDO Number:
8663 OGC Number:
P-93-003 Scheduled Completion Date:
12/26/96 Last Contact with Petitioner (s):
10/22/96 Petition Manager:
J. DeCicco w e Attorney:
R. Weisman Issues / Action Requested:
Modify license for AMS to (1) assume all costs resulting from offsite release of cobalt-60 that has been deposited at the Southerly Treatment Plant and (2) decontaminate the sewer connecting AMS with public sewer system.
Current Status:
An acknowledgment letter was issued on 4/2/93.
Extensive environmental surveys were completed by Region III during the week of 5/24/93 and an inspection report was issued on 7/29/93. A Northeast Ohio Regional Sewer District (NE0RSD) site characterization report was submitted on 6/30/94. A NE0RSD letter of 9/13/94 contained supplemental requests to this petition. An acknowledgment letter was issued on 10/14/94. A NE0RSD letter of 10/13/94 contained a supplemental request to this petition; an acknowledgment letter was issued on 11/2/94.
The scheduled completion date was extended in January and March 1995 to allow preparation of an options paper for the Commission's consideration. The staff provided status updates to the petitioner by telephone on 5/30/95,8/1/95, 10/3/95, 12/4/95, 2/12/96, 4/16/96, and 6/18/96. The completion date was extended in June 1995 to allow additional time for development of the Commission Options Paper. The completion date was extended in September 1995 to allow time for completion of further staff review in support of the Commission Options Paper.
Because of the agency-wide implications of waste disposal, the completion date was extended in December 1995 until 3/29/96, and again in March 1996 to 12/26/96 to c:ntinue staff review of the Commission Options Paper. The staff contacted the petitioner by telephone on 8/20/96, and again on 10/22/96 to discuss the status of the petition.
Facility:
Atier- =' Hadical Sys+ ---. Inc.
Petitioner:
Northeast Ohio Regional Sewer District Date of Petition:
8/19/94
{
Director's Decision To Be Issued by:
1945 5 Date Referred to Review Organization:
8/29/94 EDO Number:
10395 OGC Number:
P-94-020 Scheduled Completion Date:
7/31/97 Last Contact with Petitioner (s):
10/22/96 Petition Manager:
J. DeCicco Case Attorney:
R. Weisman i
Issues / Action Requested:
Amend AMS license to install, maintain, and i
operate alams on all drains from London Road facility.
Current Status:
An acknowledgment letter was issued on 9/7 94. The staff i
/
completed its research of Picker Corporation's (previous i
licensee) license file to establish use/ discontinuance of flow-rate alams in the 1970s. On 12/29/94 the Sewer District requested a license renewal hearing per Subpart L,.10 CFR 2.1205. The staff met on 3/14/95 to discuss the petition. The staff provided status updates to the petitioner by telephone on 5/30/95,8/1/95,10/3/95, 12/4/95, 2/12/96, 4/16/96, and 6/18/96. The scheduled completion date was delayed in June 1995 because of a license amendment request from AMS on 3/22/95, which i
requested installation of a sampling system on a proposed i
lateral sewer line. The completion date was extended in August 1995 to allow time for completion of the staff's review. The petitioner was contacted by telephone on 8/20/96, and again on 10/22/96 to discuss the status of the petition. The staff has requested an extension to the completion date to 7/31/97 to allow time for completion of the license renewal proceedings.
Facility:
Syster Creek Nuclear Generatine Station Petitioners:
P. Gunter and W. de Camp, Jr.
Date of Petition:
9/19/94, as supplemented 12/13/94 i
Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
9/29/94 EDO Number:
10473 OGC Number:
P-94-023 Scheduled Completion Date:
2/3/97,
Last C:ntact cith Petitien2r(s):
10/8/96 Petition Manager:
R. Eaton Case Attorney:-
G. Longo Issues / Action Requested:
Immediately suspend Oyster Creek license until the licensee (1) inspects and repairs or replaces all safety-class reactor internal component parts subject to embrittlement and cracking, (2) provides an analysis on the synergistic effects of through-wall cracking of multiple safety-class components, and (3) addresses generic spent fuel pool design deficiencies of Oyster Creek.
Current Status:
An acknowledgment letter was issued on 10/27/94. On 12/13/94, the petitionere sent a letter appealing NRC's denial to immediately s,apend Oyster Creek's operating license. The petitioner:, stated that the staff did not address their concerns regarding reactor vessel internal cracking and spent fuel pool cooling. A letter responding to the petitioners' appeal was issued on 4/10/95. The staff indicated that it is treating the 12/13/94 letter as a supplement to the 9/26/94 petition. The staff also indicated that NRC regulations make no provisions for appeal or reconsideration of such administrative determinations. The staff advised the petitioners that i
they provided no bases for revisiting the denial of the 9/19/94 request for immediate suspension of the license.
~
On 3/20/95, a letter was sent to the petitioners, for information only, transmitting an NRC letter dated 3/8/95 to Messrs. Lochbaum and Prevatte relating to the safety of spent fuel pool storage at the Susquehanna Steam Electric Station. On 5/22/95, Paul Gunter called to request i
information regarding Oyster Creek shroud bracket fabrication. The petition manager provided the requested information by telephone on 5/23/95.
On 6/16/95, Paul Gunter called to ask why GPUN was moving fuel. The NRC staff advised Mr. Gunter that to the best of its knowledge, the fuel was being moved to a different area of the spent fuel pool to prepare for moving fuel to the dry fuel storage facility. The staff advised Mr. Gunter that GPUN did not intend to transfer the failed fuel element into the dry fuel storage facility. The staff issued a partial Director's Decision (DD-95-18) on 8/4/95 denying Requests (1) and (2) of the 9/19/94 petition and Request (1) of the 12/13/94 supplemental petition.
In a letter of 9/1/95, the Secretary of the Commission advised the petitioners that the Cosuiissioners allowed the time provided by NRC regulations within which the Commission may act to review Director's Decision 95-18 to expire; accordingly, Director's Decision 95-18 became a i
final agency action on 8/28/95.
Paul Gunter called on 9/14/95 to make sure that the staff was continuing to review the spent fuel pool cooling concern. The petition,
h =
l manager advised Mr. Guntsr that the staff is reviewing this issue generically and that upon completion of its 3
review, NRC will provide him with its evaluation.
j l
In a letter of 11/22/95 to the petitioners, the staff updated the status of its generic review and indicated r
that it had completed onsite assessments of spent fuel j
operations at four sites in addition to the detailed review at Susquehanna Steam Electric Station in response j
j to the 10 CFR Part 21 report. The scheduled completion date was extended in January 1995 to 1/30/96, and again in January 1996 to 7/31/96 because of additional time 3
required for staff review and resolution of issues on a generic action plan on spent fuel storage.
In a letter to the petitioners of 1/24/96, the staff updated the status of the petition and enclosed a copy of Infomation Notice (IN) 95-54, " Decay Heat Management Practices During Refueling Outages," dated 12/1/95. The staff provided a status update to the petitioners by telephone on 2/29/96.
On 4/24/96, the staff informed the petitioner of a change in the NRC petition manager. The petitioner was contacted by telephone on 7/16/96 and informed of a change in the scheduled completion date to 8/31/96.
In August 1996, the scheduled completion date was changed to 9/30/96 to allow for additional staff review.
In September 1996, the completion date was extended to 10/31/96 to allow additional time for review of the draft Director's Decision. The petitioner was contacted by telephone on 10/8/96 and informed of the change in completion date.
The completion date was extended in October 1996 to 12/1/96, and again in November 1996 to 2/3/97 to allow for further staff review.
Facility:
Geornia Tech and All Liconsees Petitioner:
P. B'ockey-O'Brien Date of Petition:
10/23/94; supplemented 11/12/94,12/4/94,2/21/95, 2/23/95,3/6/95,3/28/95,4/18/95,5/18/95,6/27/95, 7/18/95,8/18/95,8/21/95,8/28/95,8/31/95,9/17/95, 10/27/95, 1/10/96, 1/27/96, 3/14/96, and 5/24/96 Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
11/15/94 EDO Number:
10598 OGC Number:
P-94-027 Scheduled Completion Date:
6/30/97 Last Contact with Petitioner (s):
10/24/96 Petition Manager:
M. Mendonca Case Attorney:
M. Stein Issues / Action Requested:
Withdraw license from, shut down, and decommission the Neely Nuclear Research Reactor at the Georgia Institute of Technology; revoke all licenses to discharge radioactive wastes to sewers and waters of the United States and oceans of the world, and revoke all licenses that use as low as reasonably i
achievable critsrion; and add requirements to l
license for the transportation of radioactive material and to prohibit the transport of i
l radioactive material by mail.
Current Status:
The petitioner was informed on 11/21/94 that the 2.206 i
process is a public process. An acknowledgment letter was issued on 11/22/94. The petitioner was contacted and has
{
responded with supplemental letters dated 11/12/94, 12/4/94,2/21/95,2/23/95,3/6/95,3/28/95,4/18/95, l
5/18/95, 6/27/95, and 7/18/95. The scheduled completion i
date of the initial response letter was delayed in i
February 1995 because of the increased scope as a result i
of supplements and potential hearing issues. A status j
update letter was sent to the petitioner on 6/5/95. The scheduled completion date was extended in July 1995 to accommodate the remaining necessary reviews. The staff issued a partial Director's Decision (00-95-15) on 7/31/95 denying the requested actions based on the petition issues 1
considered to date. The final Director's Decision will depend on the license renewal process, including potential j
Atomic Safety and Licensing Board hearings and appeals.
l The staff expects to complete this action by 12/31/96.
1 l
In a letter dated 8/29/95, the Secretary of the Commission i
infomed the petitioner that the partial Director's i
Decision constituted the final action of the Commission on the petition issues considered to date. On 9/12/95, the staff responded to the petitioner's additional letters of 8/18/95, 8/21/95, 8/28/95, and 8/31/95. The staff received additional letters dated 9/17/95,10/27/95, 1/10/96, 1/27/96, and 3/14/96. The staff provided a status update to the petitioner by letter dated 9/12/95.
On 11/15/95, the petitioner was again informed of the status of the response to the petition via personal interaction at a Georgia Tech Research Reactor prehearing conference. The petition manager provided a status update to the petitioner by telephone on 1/22/96. A written update responding to the petitioner's 10/27/95, 1/10/96, 1/27/96, and 3/14/96 letters was'sent to the petitioner on 3/22/96. The petitioner was contacted on 5/22/96 by the petition manager at a limited appearance hearing for the ongoing license renewal proceeding. The petitioner was infcmed that evaluation of the petition was pending completion of the ongoing Atomic Safety and Licensing Board (ASLB) proceeding. The petitioner sent in a supplement dated 5/24/96, which was docketed and provided to the ASLB panel for the license renewal proceeding during the limited appearances on 5/22/96.
In a telephone conversation on 5/31/96, the petitioner indicated to an NRC Region II official that she disagreed with the partial Director's Decision of 7/31/95. This was responded to by letter dated 9/26/96. On 6/17/96 the petitioner called the NRC Chairman to indicate that all the information on her petition had been provided by her 5/24/96 supplement. The petition manager returned the a
call en 6/18/96 and discussed tha status of the 2.206 4
review with the petitioner.
Because of delays in the scheduled completion of the ASLB i
hearing on the remaining contention, the completion date d
for this petition was extended to 6/30/97. The petitioner 2
was contacted by telephone on 8/16/96 to discuss the status of the petition. A status update letter was sent to the petitioner on 10/24/96.
l Facility:
Billstone Petitioner:
A. Ross Date of Petition:
1/15/95; supplements of 10/28/94 and 10/14/95 1
Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
2/7/95 EDO Number:
10600 OGC Number:
P-95-007 Scheduled Completion Date:
3/30/97 Last Contact with Petitioner (s):
10/11/96 l
Petition Manager:
J. Andersen Case Attorney:
S. Chidakel Issues / Action Requested:
Take " accelerated" enforcement action against Northeast Utilities for violations at Millstone involving procedure compliance, work control, and tagging control.
Current Status:
An acknowledgment letter was issued on 2/23/95. The petitioner submitted additional information on 2/8/95, 2/20/95, and 2/23/95.
In the 2/23/95 letter, the petitioner requested that the EDO act on the petition as soon as possible. The staff responded to the additional submittals on 3/20/95. Status update letters were sent to the petitioner on 5/9/95, 7/19/95, and 10/4/95.
The.
status of the petitions was discussed in telephone calls with the petitioner on 5/25/95, 6/2/95, 7/24/95, 8/14/95, 9/22/95, and 5/29/96. On 5/30/95 and 6/2/95, the NRC staff discussed Northeast Utilities' letters of 3/15/95, 3/24/95, and 5/12/95 in telephone calls with the petitioner. An inspection (50-245/95-22, 50-336/95-22, 50-423/95-22) was conducted at the site in May and June 1995 to audit the licensee's response to the petitioner's concerns, which had been forwarded to the licensee. The licensee responded with its investigation into the matters during the first quarter of 1995. Because the results from the inspection were needed to prepare the Director's Decision, the scheduled completion date was extended to 9/30/95, and again to 12/30/95. The completion date was extended in November 1995 to 3/30/96, in March 1996 to 5/30/96, in May 1996 to 7/1/96, in June 1996 to 8/30/96, in August 1996 to 11/30/96, and in October 1996 to 3/30/97 to allow time for further staff review.
. - =. -. - - - - -. - - -...
l Based on a ccpy of the petiticn obtain:d by Nsrtheast Utilities, the licensee voluntarily provided a response to the petition on 5/12/95.
In a letter dated 10/9/95, the f
petitioner stated that the NRC update letters were i
inadequate.
In a letter dated 10/16/95, Congressman Gejdenson requested information concerning the petitioner's 10/9/95 letter. The staff responded to the petitioner on 12/12/95 (and to Congressman Gejdenson on l
12/14/95) and provided a status update on his petitions.
In a letter dated 10/14/95, the petitioner submitted an j
additional 10 CFR 2.206 request. On 11/24/95 the staff, i
responded to the petitioner's 10/14/95 letter and informed
]
the petitioner that its 10/14/95 letter will be treated as a supplement to this petition. On 2/7/96, 4/16/96, 8/12/96, and.10/ll/96, the staff sent status update j
letters to the petitioner.
i b
Facility:
Nillstone j
j Petitioner:
A. Ross i
Date of Petition:
1/5/95 l
Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
1/20/95 i
EDO Number:
15 i
OGC Number:
P-95-004 j-Scheduled Completion Date:
12/30/96 l
Last Contact with Petitioner (s):
10/11/96 i
Petition Nanager:
J. Andersen S. Chidakel j
Case Attorney:
Issues / Action Requested:
Institute sanctions against department manager, first-line supervisor, and two co-workers for i
engaging in deliberate misconduct in violation of 10 CFR 50.5; investigate procedure violations.
l l
Current Status:
An acknowledgment letter was issued on 2/23/95.
Status
, update letters were sent to the petitioner on 5/9/95, 7/19/95, and 10/4/95. The status of the petitions was discussed in telephone calls with the petitioner on 5/25/95, 6/2/95, 7/24/95, 8/14/95, 9/22/95, and 5/29/96.
On 5/30/95 and 6/2/95, the NRC staff discussed Northeast Utilities' letters of 3/15/95, 3/24/95, and 5/12/95 in telephone calls with the petitioner. An inspection (50-245/95-22,50-336/95-22,50-423/95-22) was conducted at l
the site in May and June 1995 to audit the licensee's response to the petitioner's concerns, which had been i
l forwarded to the licensee. The licensee responded with its investigation into the matters during the first l
^
quarter of 1995. Because the results from the inspection were needed to prepare the Director's Decision, the i
scheduled completion date was extended to 9/30/95, and again to 12/30/95. The completion date was extended in 3
i November 1995 to 3/30/96, in Narch 1996 to 5/30/96, in May i
1996 to 7/1/96, in June 1996 to 8/30/96, in August 1996 to l
. i
l l
9/11/96, in Octcber 1996 to 11/30/96, and in November 1996
[
to 12/30/96 to allow time for further staff review.
Based on a copy of the petition obtained by Northeast Utilities, the licensee voluntarily provided a response to the petition on 8/31/95.
In a letter dated 10/9/95, the petitioner stated that the NRC update letters were inadequate.
In a letter dated 10/16/95, Congressman Gejdenson requested information concerning the petitioner's 10/9/95 letter. The staff responded to the petitioner on 12/12/95 (and to Congressman Gejdenson on 12/14/95) and provided a status update on his petitions.
On 2/7/96, 4/16/96, 8/12/96, and 10/11/96, the staff sent status update letters to the petitioner. The draft Director's Decision is being reviewed by the staff.
i l
Facility:
R111 stone l
Petitioners:
G. Galatis, and E. Hadley on behalf of We the People, Inc.
Date of Petition:
8/21/95, supplemented 8/28/95 Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
8/30/95 EDO Number:
603 OGC Number:
P-95-015 Scheduled Completion Date:
5/31/97 Last Contact with Petitioner (s):
11/15/96 Petition Manager:
S. Dembek Case Attorney:
R. Hoefling Issues / Action Requested:
The petitioners allege that Northeast Utilities (NU) has offloaded more fuel assemblies into the spent fuel pool than permitted under License Amendments 39 and 40; that NU has knowingly operated Millstone in violation of its operating licenses; and that NU has submitted material false statements.
Petitioners seek institution of a proceeding to suspend the operating license for Millstone Unit I for 60 days after the unit is brought into compliance with the license and the design basis.
In addition, the petitioners request that the operating license be revoked until the facility is in full compliance with the terns and conditions of its license; before reinstatement of the license, a detailed independent analysis of the offsite dose consequences of total loss of spent fuel pool water be conducted; that enforcement action be taken against NU pursuant to 10 CFR 50.5 and 50.9; that actions be taken regarding a proposed license amendment pending before the Connission wherein NU seeks to increase the amount of spent fuel it may offload and that the amendment be denied; that the NRC retain an independent expert, at NU's expense, to prepare a safety analysis report on the l
proposed amendment; and that, before the issuance of any amendment, an analysis including both the probability and consequences of applicable events be conducted.
In the supplement, Mr. Galatis raises additional concerns. These concerns are that NU also committed violations by offloading more than one-third of a core of fuel at Millstone Units 2 and 3 and Seabrook Unit 1.
In addition, with regard to Millstone Unit 3, Mr. Galatis is concerned that NU submitted a material false statement to the NRC associated with a license amendment and that an unanalyzed condition exists with regard to system piping for full-core offload events. With regard to Seabrook Unit 1, Mr. Galatis is concerned about technical specification violations associated with a criticality analysis. Finally, the petitioners make the additional request that a public hearing be held in the vicinity of Millstone Unit I to permit comment by the public on the issues raised in the petition.
Northesst Utilities (NU) voluntarily provided its response Current Status:
to the 8/21/95 letter on 9/22/95 and to the 8/28/95 supplement on 10/11/95. On 9/22/95, the staff contacted the petitioner to inform him that issuance of the acknowledgment letter had been delayed because of ongoing investigations by the Office of Investigations (01) and the Inspector General (IG) as well as independent NRC The staff also informed the petitioner that if reviews.
he wanted to intervene in the Millstone Unit I spent fuel The pool amendment, he had until 9/29/95 to do so. The staff acknowledgment letter was issued on 10/26/95.
completed its review of the licensee's amendment request and on 11/9/95 issued the amendment and safety evaluation.
The staff reviewed the IG and OI reports to determine if future inspections at Millstone were needed. A spent. fuel pool inspection was conducted at Millstone in March 1996 to review the 10 CFR 2.206 concerns as well as other spent fuel pool issues. The scheduled completion date was extended in February 1996 to 7/30/96 because of technical issues requiring further staff review. On 2/1/96 and 4/9/96, the staff issued status update letters to the On 2/5/96, a Federal Register notice was petitioner.
issued announcing a 10 CFR 2.206 infomal public hearing to be held on 3/7/96. The 3/7/96 meeting was postponed The meeting that was because of poor weather.
subsequently held on 4/8/96 was well attended and there was considrable public interest in the issues raised in However, the staff did not identify any the petition.
significant new safety issues requiring further staff On 4/12/96 the staff mailed the petitioners and action.
the licensee an advance copy of the 4/8/96 meeting transcript. On 4/24/96 the staff mailed the petitioners the official transcript.
i On 6/7/96 the staff issu:d a status update letter to ths i
The update letter included a 5/21/96 report petitioners.
on the NRC's survey of refueling practices and a 5/17/96 1etter from NU that answered an NRC question raised during l
the 4/8/96 informal public hearing. On 7/19/96 the staff j
issued a status update letter to the petitioners and sent the petitioners a copy of the NRC inspection report for the Millstone I spent fuel pool issues. The completion j
date was extended in August 1996 to 10/31/96, and again in l
October 1996 to 5/31/97 to allow for additional staff On 9/19/96 the staff issued a status update j
review.
letter to the petitioners and sent the petitioners an NRC i
memorandum dated 7/26/96 informing the Commission of the resolution of the spent fuel storage pool action plan issues. On 11/15/96 the staff issued a status update i
letter to the petitioners which included an example of a 10 CFR 50.54(f) letter sent to all plants (except Millstone) requiring information that will provide the i
i staff with added assurance that plants are operated and maintained in accordance with their design bases and any l
deviations are reconciled in a timely manner. See i for further information.
.i Palisades Plant l
Facility:
M. Sinclair and S. Skavroneck on behalf of Don't Waste i
Petitioners:
Michigan and Lake Michigan Federation, respectively l
Date of Petition:
9/19/95, as amended 9/30/96 l
l Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
10/4/95 f
665 i
EDO Number:
P-95-019 1
OGC Number:
Scheduled Completion Date:
12/31/96 i
Last Contact with Petitioner (s):
11/18/96 s
W. Reckley Petition Manager:
L. Clark Case Attorney:
(1) Determine that Consumers Power Company Issues / Action Requested-violated the requirements of 10 CFR 72.212(b) by
~
using the general license provided by 10 CFR 72.210 prior to establishing that conditions set forth in Certificate of Compliance Number 1007, Revision 0, for a cask unloading procedure had been met.
(2) Suspend Consumers Power Company's use of the general license until (a) the safety issues have been resolved, (b) NRC has documented review and approval of the revised cask. unloading procedure, and (c) Cask No. 4 has been unloaded.
(3) Require a penalty of be paid by Consumers Power Company.
$1,300,000 (4) Allow petitioners to participate in the review of the procedures and any other hearings and proceedings initiated in response to this petition.
'. l Current Status:
Th2 petiticn manag2r spsks uith tha petitieners by telephone on 10/16/95 to' inform them that the 10 CFR 2.206 1
process is public and.to obtain clarification on one issue. The staff issued an acknowledgment letter on 10/24/95. The petition manager, the Palisades project i
manager, and.a member of the Plant Systems Branch spoke to the petitioner and another member of the public on i
11/15/95. Most of the questions asked by the petitioner i
concerned transportation casks and were only vaguely related to the petition. On 11/20/95 the staff sent Consumers Power Company a request for. information on cask i
unloading procedures. A copy of the request was forwarded to the petitioners. The petition manager provided an update to the petitioners on~12/15/95 and 12/18/95.
Consumers Power Company responded to the request for additional information on 12/20/95. The staff sent a copy of the request for additional information and the licensee i
response of 12/20/95 by letter to the petitioners on 2/14/96.
In response to a request from Petitiorer Sinclair, the staff sent a letter dated 12/28/95, documenting that the staff is not aware of any reactor licensee who has offloaded a spent fuel dry storage cask.
In a letter dated 6/18/96, the staff identified the subsequent offloading of a cask at Point Beach and corrected the record by identifying two additional occurrences of cask unloadings in the 1980's.
The scheduled completion date was delayed because of the staff review (begun before the petition was received) of Revision I to the Palisades cask unloading procedure. On 2/14/96, the staff extended the due date for the Director's Decision to 6/28/96 on the basis of the current status of the staff's review of Revision 1 of the unloading procedure. The staff provided an update of the status of the petition by telephone to Petitioner Skavroneck on 2/21/96, and to Petitioner Sinclair on 3/25/96. The completion of the review of Revision I has slipped pending additional review of the 5/28/96 hydrogen ignition event at Point Beach.
In addition, a second request for additional information was sent to the licensee in a letter dated 6/20/96. The licensee responded to this request in a letter dated 7/19/96.
In a phone conversation between the NRC case attorney and the attorney for the Lake Michigan Federation, the Lake Michigan Federation attorney indicated that she felt there were documents the petition manager should have forwarded that had not been sent. The NRC case attorney agreed to look at recent documents associated with this docket and send any required by NRC procedures. The Lake Michigan Federation attorney also indicated that she believed the staff's denial of the Petition to Intervene from the Michigan Attorney General was inappropriate because she considers this to be a proceeding. The NRC case attorney explained the staff's position that it is not a proceeding based on Section 2.206. The petitioner's attorney did not agree and sent a letter to that effect on 5/8/96. -.
i l
Tha staff received the 5/8/96 lettsr from the attorney for i
the Lake Michigan Federation questioning the staff's i
handling of this petition and the 2.206 process in general. The staff responded on 6/6/96 and explained that 3
the NRC's review of the petition is not the subject of a 1
formal proceeding. On 7/18/96, the staff responded to a i
similar letter dated 5/15/96 from the Assistant Attorney General for the State of Michigan. The staff also received a letter dated 7/12/96 from the Attorney General j-of Michigan regarding the timeliness of the staff's l
1 response to the petition and the event at Point Beach.
j Chainman Jackson responded to the Attorney General in a letter dated 8/26/96.
The public exit meeting for the inspection of Revision 1 l
of the Palisades cask unloading procedure has been delayed i
due to the event at Point Beach. Based on the anticipated technical and resource implications of the Point Bevh i
event, the staff extended the due date for this pr, 3 ion i
to 10/31/96. Following routine update discussion:. ith w
the petitioner on 6/17/96, the staff provided, b) letter dated 7/2/96, a list of documents received or transmitted i
i by the staff pertaining to the petition. On 6/17/96 the staff received a letter from the petitioners regarding the j
hydrogen ignition event at Point Beach.
The staff responded to the 6/17/96 letter in a letter dated 8/8/96.
The staff review of the original Palisades cask unloading procedure performed in support of this petition, will be i
documented in a routine NRC inspection report. The status l
of the staff's review was conveyed to petitioner Sinclair i
in a telephone conversation on 8/28/96. A telephone
)
conversation was held with petitioner Roemer on 9/25/96 regarding related documents, processes related to confimatory action letters, and the status of the petition review. Additional documents related to the.
petition were sent to the petitioners on 9/30/96. The i
petitioners amended the petition on 9/30/96 to include j
issues identified following the hydrogen ignition event at Point Beach. The scheduled completion date was extended 2
in October 1996 to 11/15/96, and in November 1996 to 1
1 12/31/96 in order to address the amendment to the petition. A draft Director's Decision is being reviewed by the staff. Additional material and a status of the petition were provided to the petitioners in a letter dated 11/7/96. A telephone conversation was held with petitioner Sinclair on 11/13/96 to discuss NRC processes for confimatory action letters and the NRC response to a letter from Senator Levin. Status update letters were sent to the petitioners on 11/14/96 and 11/18/96.
Facility:
National Institutes of Health (NIH)
Petitioners:
Drs. M. Ma and B. Zheng (D. Katz)
Date of Petition:
10/10/95.
Dirsctor's Decision To Be Issued by:
NNSS Date Referred to Review Organization:
10/10/95 EDO Number:
721 OGC Number:
P-95-021 Scheduled Completion Date:
2/28/97 Last Contact with Petitioner (s):
11/12/96 Petition Manager:
C. Jones Case Attorney:
G. Longo Issues / Action Requested:
(1) Suspend or revoke materials license of NIH because of willful, reckless, and deliberate violation of numerous regulatory requirements resulting in internal contamination of the petitioner, the petitioner's fetus, and other NIH employees; (2) take other appropriate enforcement action against NIH for its willful and reckless violation of 10 CFR Part 20.
Current Status:
The petitioner was informed on 10/17/95 that the 2.206 process is a public process. An acknowledgment letter was issued on 10/30/95. The request that license no. 19-00296-10 be immediately suspended or revoked pending resolution of the petition was denied in the acknowledgment letter. On 11/2/95, the NRC issued a demand for information to NIH in which it requested that NIH submit a complete and thorough response to each of the issues raised in the petition. The response was received by the NRC on 12/11/95. The NRC, in a letter to NIH dated 1/29/96, forwarded to NIH a redacted version of a 1995 augmented team inspection (AIT) report and scheduled an open predecisional enforcement conference at NRC Headquarters on~2/26/96. NIH responded in a letter dated 2/14/96 requesting an extension of the predecisional enforcement conference until the middle of April.
In a letter dated 3/19/96 to NIH's General Council, the NRC stated that the open predecisional enforcement conference i
had been set for 4/19/96 at NRC Headquarters and that several apparent. violations identified during the 1995 NRC AIT, as well as during a special inspection conducted in j
late 1995, would be discussed at the conference.
The petitioners submitted a reply (dated 3/25/96) to NIH's response to NRC's Demand for Information which discusses a number of concerns raised by NIH's submittal to the NRC (dated 12/11/95). On 3/25/96 NIH wrote to NRC's General Counsel requesting, among other items, that the NRC hold the predecisional enforcement conference in Region I, and that the meeting be held as a closed meeting not open to the public. Subsequently, a representative from NRC's j
i Office of General Counsel informed NIH that NRC's plans were to go forward with an open conference on 4/19/96.
i NIH responded in writing (letter dated 4/16/96) and informed the NRC that NIH would not attend the enforcement conference scheduled on 4/19/96 in order to preserve privacy interests associated with the issues raised and would instead make a written submission to the NRC AIT inspection report by 5/24/96. - - - - -
The staff extended completien of this 2.206 by 3 months i
due to the delay in receiving the NIH submittal and i
notified the petitioner of the delay by telephone on 5/6/96. NIH submitted its response on 5/23/96 (which was received by NRC on 5/28/96) to the apparent violations as described in an NRC letter dated 1/29/96. The staff reviewed the document and on 6/6/96 placed a copy of the NIH redacted response in the NRC Public Document Room.
The petition manager provided a status update to the l
petitioner by telephone on 6/5/96. The staff issued a Notice of Violation (N0V) and proposed imposition of civil penalty on 8/23/96 regarding the failure to secure from unauthorized removal or limit access to licensed materials that were stored in unrestricted areas. The petitioner was contacted by telephone on 8/23/96 and informed that the staff was requesting a 3-month extension to the j
scheduled completion date to allow time for additional i
staff review of the exposure events.
On 9/23/96, NIH responded to the above-referenced NOV, and protested the proposed imposition of civil penalty for l
violations of security requirements, as well as other violations cited in the 8/23/96 NOV. The staff is proposing to extend the completion date for this petition to 2/28/97 to allow sufficient time for review of the NIH i
response and appropriate staff action. See Attachment 3 for further details.
i I
Facilities:
Palisades Plant. Point Beach Units 1 and 2. Arkansas I
huclear One. Units 1 and 2 i
Petitioner:
F. Shillinglaw j
Date of Petition:
11/17/95 l
Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
12/28/95 EDO Number:
872 I
OGC Number:
P-95-023 Scheduled Completion Date:
12/31/96 Last Contact with Petitioner (s):
12/3/96 Petition Manager:
W. Reckley L. Clark l
Case Attorney:
Issues / Action Requested:
NRC take action to prohibit loading of VSC-24 casks at any nuclear site until the MSB #4 cask with indications in a weld, located at the Palisades. nuclear plant, is unloaded and the lessons learned are incorporated into the unloading procedures.
In support of this request the petitioner pointed out that a dry cask storage 4
action plan issued by the NRC on 7/28/95, states l
that the unloading procedures developed by i
licensees tend to be simplistic in that they do 2
not consider certain contingencies and assumptions. The petitioner asserts that because these types of problems are discovered through 1.
=r-v
+w v
w
experience, tha pr per way to unload the casks will'not be known until the defective cask at j
Palisades is actually unloaded.
Ir, addition, the petitioner states that matters su'.h as cooling, radiation exposure control during cutting, shim removal, and pool contamination require detailed NRC evaluation and, therefore, should not be simply left to the licensees to perfom without-NRC oversight.
Current Status:
The staff discussed the 10 CFR 2.206 process with the petitioner on 12/7/95 because the letter submitted was not clearly a petition. The petitioner was informed that the 2.206 process is a public process. The petitioner s
indicated she wanted the letter handled as a 10 CFR 2.206 petition. The acknowledgment letter to the petitioner was issued on 1/18/96. The staff plans to use the results of and the a similar 2.206 petition dated 9/19/95 (EDO 665) des cask separate staf? review of Revision 1 of the Palisa unloading procedure in responding to this petition. The scheduled completion date.was initially based on the estimatec. completion date of 4/30/96 for the staff review of Revision 1 of the Palisades procedure. On 2/14/96, the scheduled completion date was extended to 6/28/96 on the basis of the status of the staff's inspection of Revision 1 of the unloading procedure. The staff has reviewed i
information submitted by the Palisades licensee in letters dated 12/20/95~and 7/19/96 in response to an NRC request-for additional infomation on a related petition (EDO 665). The staff provided an update to the petitioner by letter dated 4/10/96. The completion of the review of Revision 1 to the cask unloading procedure has been delayed due to the 5/28/96 hydrogen ignition event during loading of a cask at Point Beach.
Based on the anticipated technical and resource implications of the Point Beach event, the staff extended the due date for this petition to 10/31/96. The' staff provided the petitioner with a status update in a letter dated 6/11/96. Due to concerns related to the timeliness of responding to the petition, the staff has decided to pursue completion.of the Director's Decision prior to completion of the inspection of the revised cask unloading procedure. The staff's review of the origin.21 wlanding procedure will be documented in a routine NRC bspaction report. The status of the staff's review was conveyed to the petitioner in a telephone conversation on 8/26/96. A collection of documents related to the petition were sent to the petitioner on 9/30/96. The draft Director's Decision for the related Palisades petition (EDO 665) is being reviewed by the staff. The response to this petition will be provided after EDO 665 is coa.pleted.
Additional petitions related to dry cask storage have been received by the staff in recent weeks. These factors have caused an additional delay in responding to this petition.
The petitioner was informed by letter dated 11/7/96 that -
the staff had extendid the scheduled completien date for this petition to 12/31/96. The petitioner was contacted i
by telephone on 12/3/96 to inform her that the l
confirmatory action letter had been closed for Arkansas Nuclear One and that cask loading would be initiated at i
that facility. A draft Director's Decision is being reviewed by the staff.
Facility:
Davis-Besse Petitioners:
Toledo Coalition for Safe Energy, et al.
Date of Petition:
12/5/95 Director's Decision To Be Issued by:
IMSS Date Referred to Review Organization:
12/15/95 ED0 Number:
886 OGC Number:
P-95-024 Scheduled Completion Date:
1/31/97 Last Contact With Petitioner (s):
12/10/96 Petition Manager:
E. Shum Case Attorney:
L. Clark Issues / Action Requested:
Requests the NRC to immediately issue orders to prevent the loading of spent nuclear fuel into the VECTRA Technologies Inc., NUHOMS-24P dry shielded canisters at the Davis-Besse nuclear power station until an NRC rulemaking and/or license modification hearing is conducted on all safety-related changes which have been made to the canisters, as described in the Safety Analysis Report.
Current Status:
The petitioner was informed that the 2.206 process is a public process. An acknowledgment letter was issued on 12/18/95 denying the petitioner's request to immediately issue orders to prevent cask loading. A status letter was sent to the petitioner on 1/23/96. The staff is preparing a draft Director's Decision. Because of the additional review required, in March 1996 the scheduled completion date for the Director's Decision was extended. The staff provided a status update to the petitioner by telephone on 4/18/96. The staff extended the completion date in May 1996 from 5/6/96 to 9/30/96. This extension was needed to support a staff inspection of the cask manufacturer which is scheduled for August 1996. The petitioner was contacted by telephone on 6/19/96 and informed of the delay in the completion date. 1he inspection report will be referenced in the final Director's Decision. The staff contacted the petitioner by telephone on 9/17/96 and provided him a status update report. The scheduled completion date was extended in September 1996 to 11/15/96 to allow additional time for staff review. The staff is proposing to extend the completion date for this petition to 1/31/97 to complete review of the draft Director's Decision. The petitioner was informed of the change in completion date by telephone on 12/10/96.
N Facility:
Gyster Creek Petitioner:
W. de Camp, Oyster Creek Nuclear Watch i
i Date of Petition:
5/11/96 Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
6/12/96 EDO Number:
GT96345 OGC Number:
P-96-018 Scheduled. Completion Date:
2/3/97 Last Contact with Petitioner (s):
10/8/96 Petition Manager:
R. Eaton Case Attorney:
H. McGurren Issues / Action Requested:
Requests NRC take " appropriate disciplinary action" against the licensee regarding a statement the licensee made in a neighborhood news letter which the petitioner believes to be inaccurate.
Current Status:
The staff contacted the petitioner by telephone on 7/16/96 and informed him of the staff's intent to issue a Director's Decision for this petition in conjunction with the Director's Decision for a similar petition (GT96452).
The petitioner was also informed that the 2.206 process is a public process. The scheduled completion date was extended in August 1996 to 9/30/96, in September 1996 to 10/31/96, in October 1996 to 12/16/96, and in November 1996 to 2/3/97 to allow time for additional staff review.
The petitioner was contacted by telephone on 10/8/96 and informed of the change in completion date.
Facility:
Westinehouse Electric Corooration Petitioner:
Shannon T. Doyle Date of Petition:
5/30/96 Director's Decision To Be Issued by:
OE Date Referred to Review Organization:
6/5/96 EDO Number:
GT96400 OGC Number:
P-96-014 Scheduled Completion Date:
1/31/97 Last Contact with Petitioner (s):
10/15/96 Petition Manager:
N. Manish l
Case Attorney:
S. Chidakel Issues / Action Requested:
Requests the NRC to take immediate action and issue a show cause order or civil penalty pertaining to Westinghouse's allegedly providing false information to the Department of Labor (DOL)
Administrative Law Judge concerning qualifications for health physics (HP) technicians at Westinghouse. -
Current Status:
The petiticner tas ccntacted by telephine en 7/7/96. -An l
acknowledgment letter was issued on 8/16/96 that (1) 1 denied the petitioner's request to institute a show cause j
order or civil penalty; (2) requested additional i
information from the petitioner relating to missing pages from an enclosure from the National Registry of Radiation 4
Protection Technologists (NRRPT); (3) requested a complete copy of the transcipt of the testimony given in the hearing before the DOL Administrative Law Judge; and (4) requested additional clarification regarding the alleged i
false statement by Westinghouse. A separate letter was j
sent to Westinghouse on 8/16/96 requesting a response-within 30 days to the issues raised in the petition.
The petitioner contacted the NRC's Office of Enforcement i
on 9/5/96 to determine if Westinghouse was required to respond to the staff's letter of 8/16/96, and whether the petitioner could get a copy of Westinghouse's letter before responding to the staff's letter to him of 8/16/96.
The staff contacted the petitioner on 9/6/96 and informed l
him that Westinghouse is not a licensee of the Commission and therefore is not required to respond to the staff's i
letter, and that the petitioner could get a copy of Westinghouse's response, but that the petitioner cannot wait on the Westinghouse response before responding to the
/
NRC's letter to him.
L l
On 9/30/96, the staff contacted the petitioner by telephone to identify whether he had responded to the staff's letter of 8/16/96. The petitioner stated that he f
would mail his response by 10/4/96. On 10/15/96, the staff received the petitioner's response to the staff's letter of 8/16/96.
In addition,'the staff spoke with the l
petitioner on 10/15/96 and informed him that the staff had received his response and that it was being reviewed by j
j the staff. Also on 10/15/96, Westinghouse contacted the i
staff and requested an extension (until 11/8/96) to j
respond to the staff's letter of 8/16/96. The staff j
granted Westinghouse's request. The scheduled completion date was extended in November 1996 to 1/31/97 to allow i
time for additional staff review.
/
Facility:
Oyster Creek Petitioner:
W. de Camp, Oyster Creek Nuclear Watch Date of Petition:
6/14/96 i
l Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
7/1/96 i
EDO Number:
GT96452 OGC Number:
P-96-018 1
Scheduled Completion Date:
2/3/97
)
Last Contact with Petitioner (s):
10/8/96 Petition Manager:
R. Eaton 3
j Case Attorney:
H. McGurren i
4 i,
- (.
1 Issues /Acticn R:quasted:
R:qu2sts NRC take action in relation to apparently false public testimony given by the management of GPU Nuclear. Specifically, petitioner requests
~
(1) that the NRC investigate the situation at Oyster Creek in order to ascertain whether there is some special factor at Oyster Creek that would indeed justify Mr. Barton's [then Director of Oyster Creek Station] sworn statement that it is unsafe to operate the Oyster Creek reactor without full core offload capacity, and (2) that if no special situation disqualifies Oyster Creek from operating without full core offload capacity, that NRC take appropriate disciplinary action against GPU Nuclear management for making a false statement under oath.
Current Status:
The staff contacted the petitioner by telephone on 7/16/96 and informed him of the staff's intent to issue a Director's Decision for this petition in conjunction with the Director's Decision for a similar petition (GT96345).
The petitioner was also informed that the 2.206 process is a public process. The scheduled completion date was extended in August 1996 to 9/30/96, in September 1996 to 10/31/96, in October 1996 to 12/16/96, and in November 1996 to 2/3/97 to allow time for additional staff review.
The petitioner was contacted by telephone on 10/8/96 and informed of the change in the scheduled completion date.
Facility:
Shieldalloy and Cypress Foote foreviously Foote Mineral)
Petitioner:
S. Bauman Date of Petition:
7/22/96 Director's Decision To Be Issued by:
NMSS-Date Referred to Review Organization:
8/27/96 EDO Number:
GT96596 OGC Number:
P-96-019 Scheduled Completion Date:
12/31/96 Last Contact with Petitioner (s):
10/2/96 Petition Manager:
J. Kennedy Case Attorney:
M. Rafky Issues / Action Requested:
Requests that Foote Mineral's license be reinstated, and that Shieldalloy and Cypress Foote be made co-responsible licensees with regard to the proper remediation and decommissioning of the Shieldalloy site. Also requests that any and all parties found to be involved in any wrongdoing as alleged in this complaint be terminated from employment, and that where appropriate, criminal charges be pursued. Requests that the environmental impact statement now being performed for the Shieldalloy site be teminated, and that Shieldalloy and Cypress Foote be jointly ordered to submit a decommissioning plan for licensed 4
materials that includes only a plan to remediate licensed materials (to include grading and evaluation of all various assorted options, including disposal at a licensed disposal facility). Finally, the petition requests that the Ohio Environmental Protection Agency and Department of Health evaluate all unlicensed slag found at the Shieldalloy site.
In Section Two of the petition, the petitioner alleges that Shieldalloy's decoinnissioning plan would wrongfully six licensed and unlicensed waste.
Current Status:
The petitioner was contacted on 10/2/96 and informed that the 2.206 process is a public process. An acknowledgment letter is being prepared.
Facility:
Haine Yaream and All Other Plants Usina the an no c M e for ECC5 Analyses Petitioner:
P. Sears Date of Petition:
8/19/96 Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
9/9/96 EDO Number:
GT96659 OGC Number:
P-96-020 Scheduled Completion Date:
1/31/97 Last Contact with Petitioner (s):
9/24/96 Petition Manager:
D. Dorman Case Attorney:
G. Longo i
Issues / Action Requested:
Requests the NRC take action with regard to the Maine Yankee Nuclear Power Station and all users of the RELAP computer code for emergency core cooling systems (ECCS). Specifically, the petitioner requests that the NRC fine Maine Yankee Atomic Power Company and Yankee Atomic Electric Company if computer runs have not been kept in accordance with YAEC's computer code quality assurance procedures, and that the NRC inspect all users of RELAP and fine those users not operating within required computer code verification procedures.
Current Status:
An acknowledgment letter was issued on 9/24/96.
Facility:
Northern states Power Company ISFSI Petitioner:
Florence Township, M Date of Petitions: 8/26/96 Director's Decision To Be Issued by:
MSS Date Referred to Review Organization:
9/13/96 EDO Number:
GT96669/GT96670 OGC Number:
P-96-021 Scheduled Completion Date:
2/15/97 Last Contact with Petitioner (s):
10/3/96
- l Petitlen Manager
N. De111gatti Case Attorney:
L. Clark Issues / Action Requested:
Two petitions request that the NRC take various actions regarding Northern States Power Company's (NSP) application for an Independent Spent Fuel Storage Installation (ISFSI). Specifically, petitioner requests that the NRC reject NSP's application for an ISFSI, or, in the alternative, suspend taking any action on the application pending the completion of litigation in the State courts. Requests that NSP be required to name the local governments expected to respond in the event of an emergenev and allow 60 days for local governments to comment on the proposed emergency plan. Requests the NRC take enforcement action against NSP for violating the. requirements of 10 CFR 72.32(a)(14) by not permitting the petitioner to comment on the proposed emergency plan before submission to the NRC. Specifically, the NRC is asked to impose a penalty in the amount of one million dollars and require NSP to compensate petitioner in the amount of $7500 for time expended by its Board and attorney in attempting to obtain the emergency plan before submission to the NRC.
Current Status:
The attorney for the petitioner was informed on 10/3/96 that the 2.206 process is a public process. The staff has determined that only the request for enforcement action falls within the purview of 10 CFR 2.206. All other aspects of the petition will be considered as part of NSP's application for the offsite ISFSI. An acknowledgment letter is being prepared.
Facility:
Point Beach Petitioner:
D. Duas on behalf of Wisconsin's Citizens' Utiliti Board Date of Petitions: 9/30/96 Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
10/2/96 EDO Number:
GT96774 OGC Number:
P-96-022 Scheduled Completion Date:
2/15/97 Last Contact with Petitioner (s):
12/10/96 Petition Manager:
W. Reckley Case Attorney:
L. Clark l
Issues / Action Requested:
(1) Order Wisconsin Electric Power Company (WEPCO) to retain 24 empty and available spaces in the Point Beach spent fuel pool to provide the capability to permit retrieval of spent fuel from a VSC-24 cask in the event of an accident requiring removal of spent fuel from the cask or in the event that conditions of the Certificate of -
1 f
Compliance (C0C) for the VSC-24 rcquire removal of il spent fuel from the cask, until such time that i
WEPC0 has other options available to it to remove spent fuel from a cask in the event conditions j
warrant it.
(2) Order users of the VSC-24 cask not to load VSC-24 casks until the C0C, Safety Analysis Report l
'(SAR) and Safety Evaluation Report (SER) are i
amended to contain operating controls and limits j
that prevent hazardous conditions, including but j
not limited to the generation of explosive gases, due to VSC-24 material reactions with environments encountered during loading, storage, and unloading of the VSC-24 cask.
i Current Status:
The petitioner was informed on 10/3/96 that the 2.206 process is a public process. An acknowledgment letter addressing the petitioner's immediate concern regarding offloading of the reactor core during the Point Beach Unit 2 refueling outage was issued on 10/11/96. The current status of staff reviews related to NRC Bulletin 96-04, potential loading dates for VF.C-24 casks, and staff activities related to the petition were discussed with the petitioner during a telephone conversation on 10/31/96.
i The petitioner was contacted by telephone on 12/3/96 to inform him that the confirmatory action letter had been i
closed for Arkansas Nuclear One and that cask loading l
would be initiated at that facility. An acknowledgment letter denying the petitioner's second request was issued i
on 12/10/96.
l l
Facility:
Shieldalloy 1
Petitioner:
S. Bauman Date of Petitions:
10/11/96 i
Director's Decision To Be Issued by:
MSS' Date Referred to Review Organization:
10/23/96 ED0 Number:
GT96775.
i OGC Number:
P-96-023 Scheduled Completion Date:
2/8/97 Last Contact with Petitioner (s):
11/14/96 Petition Manager:
G.. Comfort
[
Case Attorney:
M. Rafky Issues / Action Requested:
Requests that Shieldalloy's license for its Newfield, New Jersey site be revoked and
" downgraded" to one permitting possession of low-level radioactive wastes for the purpose of decommissioning only.
Petition also asserts, as a basis for this request, that Shieldalloy cannot meet NRC financial assurance requirements.
I Current Status:
An acknowledgment letter was issued on 11/14/96.
?
i
l Facility:
San Onofre Nuclear Generatine Station Petitioner:
S. Dwyer i
Date of Petition:
9/22/96 i
Director's Decision To Be Issued by:
NRR j
Date Referred to Review Organization:
10/24/96 ED0 Number:
GT96778 j
OGC Number:
P-96-024
~
Scheduled Completion Date:
3/14/97 Last Contact with Petitioner (s):
11/22/96 i
Petition Manager:
M. Fields i
Case Attorney:
H. McGurren l
Issues / Action Requested:
Requests the NRC shut down the San Onofre Nuclear Generating Station "as soon as possible" pending a i
complete review of the "new seismic risk."
i j
Current Status:
The petitioner was contacted by internet electronic mail i
on 10/16/96 and informed that the 2.206 process is a l
public process. An acknowledgment letter was issued on l
11/22/96.
1 i
Facility:
All Users of the VSC-24 Muclear Maste Storace Cask l
Petitioners:
M. Sinclair and E. Roemer on behalf of Don't Waste Michigan and Lake Michigan Federation, respectively j
Date of Petition:
10/18/96 i
Director's Decision To Be Issued by:
NMSS i
Date Referred to Review Organization:
11/13/96 EDO Number:
GT96801 OGC Number:
P-96-025 Scheduled Completion Date:
3/31/97 Last Contact with Petitioners:
11/26/96 l
Petition Manager:
M. Bailey Case Attorney:
L. Clark Issues / Action Requested:
Prohibit the loading of any and all VSC-24 nuclear t
waste storage casks by users of the cask under the i
i general license, until the NRC, following an j
f independent third party review of the VSC-24 cask design, has amended the Safety Analysis Report (SAR), Safety Evaluation Report (SER), and Certificate of Compliance (C0C) to address the significant safety concerns raised in the petition.
Current Status:
The petitioners were contacted by telephone on 11/26/96 and infor1 sed that the 2.206 process is a public process.
An acknowledgment letter is being prepared.
1 Facility:
Connecticut Yan N and Millstone Units 1. 2. and 3 Petitioners:
D. Katz, Citizens Awareness Network and P. Gunter, Nuclear l
Inforisation and Resource Service
l Date of Petition:
11/25/96 Director's Decision To Be Issued by:
NRR Date Referred to Review Organization:
EDO Number:
GT96919 OGC Number:
P-96-026 Scheduled Completion Date:
5/31/97 Last Contact with Petitioners:
Petition Manager:
Case Attorney:
R. Hoefling Issues / Action Requested:
Petitioners request the staff to take the following actions:
(1) immediately suspend or revoke Northeast Utilities' (NU) license to operate the Connecticut Yankee (CY) and Millstone reactors due to chronic mismanagement; i
(2) investigate the possibility that NU made material misrepresentations to the NRC concerning engineering calculations and other information or actions relied upon to assure the adequacy of safety systems at CY and Millstone; (3) if an investigation determines that NU deliberately provided insufficient and/or false or misleading J
information to the NRC, revoke NU's operating licenses for CY and Millstone, or, if not, keep the reactors off-line pending a Department of i
Justice independent investigation; (4) if the reactors remain operating, petitioners request that they remain on the NRC's " watch list"; (5) keep CY and Millstone off-line until.NU's chronic mismanagement has been analyzed, remedial management programs put into effect and the NRC has evaluated and approved the effectiveness of NU's actions; (6) in the event NU decides to decommission any or all of the reactors at issue, petitioners request the NRC not to permit any.
decommissioning activity to take place until the above issues are resolved; and (7) commence an investigation into how the staff allowed the illegal situation at NU's Connecticut reactors to exist and continue over a decade.
Current Status:
This petition was recently received by the staff and is being reviewed for appropriate action.
END OF STATUS REPORT
Decisions Pending Before the Commission and the Courts Petitioners:
N. Hobby /A. Mosbaugh Facility /EDO No.:
Yantle/5836 Decision No./(Date):
D0-93-08 (4/23/93) (Partial)d and remanded to staff Comments:
Denied. DD-93-08 was vacate (CLI-93-15).
4 Petitioner:
C. Norris Facility /EDO No.:
All 9_elear Power Plants /GT96105 Decision No./(Date):
DD-96-12 (9/26/96) (Final) 4 Comments:
Denied.
Petitioner:
C. Norris Facility /ED0 No.:
Catawba /GT96045 Decision No./(Date):
DD-96-14 (10/10/96) (Final)
Comments:
Denied.
Petitioner:
A. Ross Facility /EDO No.:
M111 stone /16 Decision No./(Date):
DD-96-16 (10/31/96) (Final)
Comments:
Denied.
Petitioner:
A. Ross Facility /EDO No.:
M111 stone /17 Decision No./(Date):
DD-96-17 (10/31/96) (Final)
Comments:
Denied.
i Petitioner:
P. Blanch Facility /EDO No.:
All Power Reactors /9968 Decision No./(Date):
DD-96-18 (11/6/96) (Final)
Requests (1) and (2) were granted in part. Request Comments:
(3) was outside the scope of the 2.206 process and the staff determined that the requested action in i
Request (4) was not needed.
Petitioner:
T. Saporito et al.
St. Lucie. Units 1 and 2/GT96445 Facility /EDO No.:
1 Decision No./(Date):
DD-96-19 (11/18/96) (Final)
Comments:
Denied.
1
/
i Petitlener:
A.D. Burt (Fricnds of the Coast - Opposing Nuclear Pollution) t Facility /EDO No.:
Raine Yankee /GT96181 Decision No./(Date):
00-96-20 (11/20/96) (Final)
Comments:
Requests (1), (4), in part, and (5) were denied in the acknowledgment letter dated 5/13/96. Request (6) was determined to be moot. Requests (2), (3), and in part (4) were denied in DD-96-20.
Petitioner:
S. Bjoralt and P. Gunter Facility /EDO No.:
Prairie Island Units 1 and 2/433 Decision No./(Date):
00-96-21 (11/27/96) (Final)
Comments:
Denied.
tND OF DECISION 5 PENDING 0
1
< - NOT FOR EXTERNAL DISTRIBUTION Petitions Involving the Office of Enforcement (OE),
the Office of Investigations (01), the Inspector General (IG), and the Department of Justice (00J), and Other Sensitive Information Petitioners:
G. Galatis, and E. Hadley on behalf of We the People, Inc.
Facility /EDO No.:
Rillstons/603 Comments:
The 01 report and issues regarding potential licensee wrongdoing have been forwarded to the Department of Justice for review and coordination.
Petitioners:
Drs. N. Ma and B. Zheng (D. Katz)
Facility /EDO No.:
National Institutes of Health /721 Comments:
The staff is awaiting completion of the pending FBI investigation.into the alleged willful contamination of the petitioner.
END OF PENDING ACTIONS I
h
, <u--- NOT FOR EXTERNAL DISTRIBUTION -->>>