ESAS rjutomatic Actuation Logic 3.3.7 4
i i
SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.7.1 NOTE When n ESAS automatic actuation leg 4e metrix is placed in an incperable status scicly for performance of this Surveil h nce, entry inte ;;;cciated Ccndition; and Required Action may be dehycd for up to S hours, provided the associated ES function i; maintained.
Perform automatic actuation logic CHANNEL 31 days on a FUNCTIONAL TEST.
STAGGERED TEST BASIS 1
1 Crystal River Unit 3 3.3-19 Amendment No.
9609300304 960923 PDR ADOCK 05000302 P
=
p -.
- i.,
ESAS Automatic Actuation Logic
^
3.3.7 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.7.1 Perform automatic actuation logic CHANNEL 31 days on a FUNCTIONAL TEST.
STAGGERED TEST
)
BASIS 4
i l*
l i
e i
i i
L r
1 i
i Crystal River Unit 3 3.3-19 Amendment No.
d
ESAS Automatic Actuation Logic B 3.3.7 i
i BASES l
l ACTIONS-A.1 and A.2 (continued)
With one or more automatic actuation logic matrices inoperable, the associated component (s) should be placed in the ES configuration. This manual Action essentially fulfills the safety function of the automatic actuation logic.
In some circumstances, placing the component in its ES configuration would impose an undue operational restriction.
In these cases, Required Action A.2 allows for the component status be left as-is, and the supported system component declared inoperable.
Conditions which would potentially preclude placing of a component in its ES configuration include, but are not limited to, violation of system separation, activation of fluid systems that could lead to thermal shock, ~cr isolation of fluid systems that are normally functioning.
The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time is based on operating experience and reflects the urgency associated with the inoperability of a safety system component.
SURVEILLANCE SR 3.3.7.1 REQUIREMENTS SR 3.3.7.1 is the performance of a CHANNEL FUNCTIONAL TEST on a 31 day STAGGERED TEST BASIS. The CHANNEL FUNCTIONAL TEST of the Automatic Actuation Logic nv3d only demonstrate one combination of the three two-out-of-three logic combinations that are required to be OPERABLE.
A different combination is tested at each test interval, such that all three combinations will be confirmed to be OPERABLE by the time the third successive test is completed. The Frequency is based on operating experience that demonstrates the low likelihood of more than one channel failing within the same 31 day interval.
A Note h: been added to indicate entry into the Required Action cf this Specificatica may be deferred for up tc S hours for ; channel inoperable for Surveillance testing provided the remaining twc ESAS channel are capable of performing the
- cciated ES Function.
Thi: allcwance consider: the average time required tc perform the SR and is b :cd on the inability tc perform the Survcillance in the time permitted by the R0guired Acti0n: Or the undC;ir0bility Of perf0rming th0:0 ACTION &r (continued)
Crystal River Unit 3 F 3.3-63 Amendment No.
ESAS Automatic' Actuation Logic B 3.3.7 BASES ACTIONS A.1 and A.2 (continued)
With one or more automatic actuation logic matrices inoperable, the associated component (s) should be placed in the ES i
configuration.
This manual Action essentially fulfills the safety function of the automatic actuation logic.
In some circumstances, placing the component in its ES configuration-would impose an undue operational restriction.
In these cases, Required Action A.2 allows for the component status be left as-is, and the supported system component declared inciperable.
)
Conditions which would potentially preclude placing of a component in its ES configuration include, but are not limited to, violation of system separation, activation of fluid systems that could lead to thermal shock, or isolation of fluid systems that are normally functioning.
The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time is i
based on operating oxperience and reflects the urgency associated with the inoperability of a safety system component.
SURVEILLANCE SR 3.3.7.1 REQUIREMENTS SR 3.3.7.1 is the performance of a CHANNEL FUNCTIONAL TEST on a 31 day STAGGERED TEST BASIS. The CHANNEL FUNCTIONAL TEST of the Automatic Actuation Logic need only demonstrate'one combination of the three two-out-of-three logic combinations that are required to be OPERABLE. A different combination is tested at each test interval, such that all three combinations will be confirmed to be OPERABLE by the time the third successive test is completed.
The Frequency is based on operating experience that demonstrates the low likelihood of more than one channel failing within the same 31 day interval.
(continued)
Crystal River Unit 3 B 3.3-63 Amendment No.