ML20128Q081

From kanterella
Jump to navigation Jump to search
Nonproprietary Analytical Rept for South Texas Project 1, Houston Lighting & Power Co
ML20128Q081
Person / Time
Site: South Texas STP Nuclear Operating Company icon.png
Issue date: 10/31/1977
From: Basol M, Halliday J, Hofses A
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
To:
Shared Package
ML20128P958 List:
References
CENC-1302, CENC-1302-01, CENC-1302-1, NUDOCS 8507260582
Download: ML20128Q081 (4)


Text

. .

REPORT NUMRER CENC 1302 Stl8JUOT CATEGORY:

" ANALYTICAL REPO6T" ENGINEERING CG,idVSTit/J ENG'NUERildG,INC.

NUCLEAR COMFONEN TS E:iuliv2F. RING DEPARTidair C. E. CONTRACT NO.11073 ANALYTION. P.F.70.*tT FOR COUTH T:fMS PP.OJECT N9.1 NOU$ TON *.lGFTING AND POWER COMPANY l

l J. Hallkte, l A. 5. >iofses October 19/7 POWER r! SYSTEMS l COMBUSTION ENGINEERING, INC.

Nuclear Components Department CHATTANOOGA, TENNESSEE, U.S.A.

DR A O 8

THIS DOCUMEN'T IS THE PROPERTY OF i COMBUSTION ENGINEERING. INC., WINDSOR CONNECTICUT,

' AND IS NOT TO BE REPRODUCED, OR USED TO FURNISH ANY

( INFORMATION FOR MAKING OF DRAWINGS OR APPARATUS EXCEPT WHERE PROVIDED FOR BY AGREEMENT WITH SAID COMPANY.

l L

ABSTRACT i The structural integrity of the Houston Lighting and Power Company, South Texas Project No.1 Reactor Vessel, C.E. Contract 11073 is established in this The vessel is designed in accordance with the requirements of the report. 952545, Rev. 0* dated June,1,1977 Westinghouse Equipment Specification No.

and the 1971 Edition of Section III of the ASME Code with Addenda through the i Summer of 1973 and Code Case N-52 (1605). All requirements are satisfied.

  • Plus Interim E-Specs No. 1 thru 4.
  • PREPARED BY Y. >

b&

A. 5. Hofses //

J. 'lliday f Thermal Engine #

5 ctural Engineer CHECXED BY M sul & L ALA J.g. SchwalT M. Basol TMnnal Engineer Structural Engineer

/LO*V W V fk - is R. N. Denton D. W. Vroom Supervisor Thennel

( Supervisor Structural APPROVED BY

/F. P. Hill, Jr.

Manager Analytical Department P. Hlqv<hs so su f

A lYYb?

'/ 'N

\ 0F 1 It is hereby certified that the components described in this Analytical Report have been properly and completely reconciled with the requirements of the ASME Boiler and Pressure vessel Code,Section III, and this certification is provided as required by Paragraph NA-3356 of said ASME Code,Section III.

O 9 (9) h' I

e 9