. _ _ _

HEPORT NUMBER CENC - 1332 SUBJECT CATEGORY:

" ANALYTICAL REPORT" ENGINEERING COMBUSTION ENGINEERING,INC.

NUCLEAR COMPONENTS ENGINEERING DEPARTMENT C.E. CONTR ACT NO.11073 ADDENDUM 1 f

TO ANALYTICAL REPORT FOR SOUTH TEXAS PROJECT NO.1 HOUSTON LIGHTING AND POWER COMPANY

,a

  • wg C. F RENCH 4

,, W J. CHARNESKl COMBUSTION ENGINEERING, INC.

JUNE 1978 Nuclear Components Department CHATTANOOGA, TENNESSEE, U.S.A.

hD D

)) 90 A

PDI4

1 THIS DOCU!EliT IS TIIE PROPERTY OF C0!GUSTI0!i E!!OIliEERI!iG, I!!C., WI!E)SOR, C0!1!iECTICUT, AliD IS It0T TO DE REPRODUCED, OR USED TO FUR!!IS!! A!TY I!iFOR!MTIO!! FOR IMKI!!3 0F DRAWI!!GS OR APPARATUS EXCEPT WlERE PROVIDED FOR DY AGREE!EliT WITl! SAID C0!@A!Pl.

O e

i l

e

u v -

I f

TADLE OF C0!.TE!TS l

I II.TRODUCTIO!!....................................

2 i

II SCOPE...........................................

2

)

III S IO!!IFIC A!TT PIO ULTD.............................

2 IV APPEliDICES A.

Structural Analysin.........................

A-1 D.

Thorr.nl Analycic............................

D-1 l

l

-.s

o AP9 TRACT lhe structural integrity of the !!ouston Lighting and Power Company, routh Texas Project flo.1 Reactor Vossol, C.E. Contract 11073 is potablished in this report.

The vennel in desinged in accordanco rith the requirements of the Westinghouso Equipment Specification to. 952545, Rev. o' dated June 1, 1977 and the 1971 Edition of lection III of the A0!'E Code with Addenda through the Summer of L973 and Code Case li-52 (1605).

All requirements are satisfied.

'Plus Interim E-Specs !!o.1 thru 4 l

PREPARED BY

$44$ h YJ'-

AAmJAs

l. French J. J. QMrnoski pupervisor Thormal Engincor I

f cilEcKED BY 1hh&LJ d / L sf

.asol

~

~

/)'R.(Jchwall N

$tructural Engincor Thormal Engincor l

BEVINED BY

$nso h U

t. C. Watson

/

f D. W. Vroom Bection l'.anager Supervisor Thormal APPTOVED BY F. P. Hill, Jr.

Ihnager Department

.gg

'*e lp.'

jf

'.h Q

/

\\ *% 4,

li

t..

1 g[c

  • eo, s 4s 0F %%

lt is hereby cortified tha Yo components described in this Analytical i

l loport have boon proporly and coc:pletely reconciled with the requiro-l tents of the A31/2 Dollar and Prosauro Vossol Codo, Coction III, and l

Lhis cortification is provided as required by Paragraph !!A-3356 of l

laid A0!E Codo, Coction III.

1 l

l

"--~%__

~__M

  • g 4

h 4

I 1

1 e

_---