Forwards Laboratory Test Repts & Responses That Document Results of Fire Endurance Testing Described in Engineering Rept, Evaluation of Thermo-Lag Fire Barrier Sys.
Date released: 05/21/2020 Download: ML20127K787


Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (24 Inch Tray W/Air Drops).
ML20128H119
Person / Time
Site: Comanche Peak 
Issue date: 01/14/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H119 (609)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (24 Inch Tray W/Tee).
ML20128H112
Person / Time
Site: Comanche Peak 
Issue date: 01/13/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H112 (454)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (Two 3 Inch Conduits W/Junction Boxes).
ML20128H102
Person / Time
Site: Comanche Peak 
Issue date: 01/07/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H102 (265)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (3/4 Inch,3 Inch & 5 Inch Conduits W/Radial Bends).
ML20128H092
Person / Time
Site: Comanche Peak 
Issue date: 01/05/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H092 (248)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (30 Inch Tray).
ML20128H077
Person / Time
Site: Comanche Peak 
Issue date: 01/13/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H077 (446)
Fire Endurance Test of Thermolag 330-1 Fire Protective Envelope (36 Inch Tray W/Tee).
ML20128H068
Person / Time
Site: Comanche Peak 
Issue date: 11/04/1992
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H068 (447)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (3/4 Inch,1-1/2 Inch & 2 Inch Conduits).
ML20128H052
Person / Time
Site: Comanche Peak 
Issue date: 01/13/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H052 (571)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (Two 3 Inch Conduits W/Junction Boxes).
ML20128H031
Person / Time
Site: Comanche Peak 
Issue date: 01/11/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H031 (545)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (30 Inch Tray W/Tee).
ML20128H018
Person / Time
Site: Comanche Peak 
Issue date: 01/13/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128H018 (448)
Fire Endurance Test of Thermo-Lag 330-1 Fire Protective Envelope (12 Inch Tray).
ML20128G998
Person / Time
Site: Comanche Peak 
Issue date: 01/13/1993
From: Humphrey C, Priest D
OMEGA POINT LABORATORIES
To:
References
Download: ML20128G998 (504)
Draft P848/D11, Procedure for Determination of Ampacity Derating of Fire Protected Cables.
ML20128G994
Person / Time
Site: Comanche Peak 
Issue date: 04/06/1992
From: Alhussaini T, Bhatia P, Gwal A
INSTITUTE OF ELECTRICAL & ELECTRONICS ENGINEERS
To:
References
Download: ML20128G994 (30)
Ampacity of Power Cable Wrapped W/330-660 Installed as Free Air Drop.
ML20128G986
Person / Time
Site: Comanche Peak 
Issue date: 10/02/1992
From: Blagbrough R
STONE & WEBSTER, INC.
To:
References
Download: ML20128G986 (172)
Cable Ampacity Derating Factors for Conduits Boxed in W/ Thermolag (TSI Product).
ML20128G968
Person / Time
Site: Comanche Peak 
Issue date: 02/24/1987
From: Petty K
STONE & WEBSTER, INC.
To:
References
Download: ML20128G968 (131)
Design Validation of Conduits W/Thermolag.
ML20128G955
Person / Time
Site: Comanche Peak 
Issue date: 12/29/1992
From: Riding K
ABB IMPELL CORP. (FORMERLY IMPELL CORP.)
To:
References
Download: ML20128G955 (391)
Calculation of Weights Due to Fire Protection Matl.
ML20128G949
Person / Time
Site: Comanche Peak 
Issue date: 01/22/1993
From: Riding K
ABB IMPELL CORP. (FORMERLY IMPELL CORP.)
To:
References
Download: ML20128G949 (21)
Procedure Change Notice 01 to Rev 2 to 2IM-5.02-CND, Conduit & Conduit Support Design.
ML20128G931
Person / Time
Site: Comanche Peak 
Issue date: 08/18/1992
From: Ashley G, Pandy D, Pugh C
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
References
Download: ML20128G931 (240)
Rev 0,to Evaluation of Unit 2 Thermo-Lag Configurations.
ML20127K812
Person / Time
Site: Comanche Peak 
Issue date: 01/19/1993
From: Dibe R, Hootm C
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
References
Download: ML20127K812 (181)
Forwards Laboratory Test Repts & Responses That Document Results of Fire Endurance Testing Described in Engineering Rept, Evaluation of Thermo-Lag Fire Barrier Sys.
ML20127K789
Person / Time
Site: Comanche Peak 
Issue date: 01/19/1993
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20127K789 (24)
Forwards Laboratory Test Repts & Responses That Document Results of Fire Endurance Testing Described in Engineering Rept, Evaluation of Thermo-Lag Fire Barrier Sys.
ML20127K784
Person / Time
Site: Comanche Peak 
Issue date: 01/19/1993
From: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20127K784 (22)