ML20127F224

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 70-1151/85-02 on 850219-22 & Notice of Violation
ML20127F224
Person / Time
Site: Westinghouse
Issue date: 03/13/1985
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Damore M
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML20127F179 List:
References
NUDOCS 8505200367
Download: ML20127F224 (1)


Text

-

.f

0L f ,

HAR 13196 Westinghouse Electric Corporation ATTN: Mr. Mead D'Amore,' Acting Manager Colt nbia ~ Plant

-Nuclear Fuel Division

. Drawer R Columbia, SC' 29250 Gentlemen:

SUBJECT:

REPORT.NO.- 70-1151/85-02

- On February 19 - 22, 1985, NRC inspected activities authorized by NRC License No. SNM-1107 for your Columbia facility. At the conclusion of the inspection, the findings were discussed with 'those members of your staff identified in the

~

enclosed inspection report.

JAreas examined during.the inspection are identified in the report. Within these s

areas, the. inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observation of activities

'in progress.

The inspection - findings indicate that certain activities -violated NRC require-

.ments. The violations, references to pertinent requirements, and elements to be included in your response ate presented in the enclosed Notice of Violation'.

In accordance with 10 CFR 2.790(a), a copy -of this letter, .its enclosures, and

.your reply will be placed in NRC's Public Document Room upon completion of our evaluation of. the reply. If you wish to withhold information contained therein,

.please notify this office by telephone or include a ' written application to withhold information in your response. Such application must be consistent with-

.the requirements of 2.790(b)(1).

- The responses directed by this letter and the enclosures are not subject to the clearance procedures of the Office of Management and Budget issued under the Paperwork Reduction Act of 1980, PL.96-511.

Should you have any questions concerning this letter, please contact us.

L L, Sincerely, l

J. Philip Stohr, Director L Division of Radiation Safety

'and Safeguards-

Enclosures:

1. Notice of Violation i: 2.. Inspection Report No. 70-1151/85-02

-bcc: (See Page'2) i .,

I l

~

8505200367 850412 PDR ADOCK 07001151 ,

C PDR 3

< -