ej,.,
<v g
P \\ 3 4 Westinghouse 6 gg B m oive manufactwing Department Electric Corporation Drawer R Columbia, Seth Carolina 29250
@03 TIS 2610 April 4, 1985 U.' S. Nuclear Regulatory Commissian ATTN: -Mr. J. Philip Stohr, Director Division of Radiation Safety and Safeguards Region II 101 Marietta Street, N.
W., Suite 2900 Atlanta, Georgia 30323
.RE: EC Report No. 70-1151/85-02 Gentlemen:
Pursuant to the provisions delineated in Section 2.201 of the WC's " Rules of Practice," Part. 2, Title 10, Code of Federal Regulations, Westinghouse therein provides, in ~ Appendix A, formal response to your -letter of March 13, 1985, ~ regarding your - inspection of our facilities' conducted during the period February 19-22, 1985.
Should you ' have any questions or require additional information, please telephone me at (803) 776-2610.
I.hereby affirm that the statements L me h in. this response are true and
-correct to the best of my knowledge and belief.
Sincerely, WESTINGHOUSE ELECTRIC CORPORATION L
^
@sm_
Mead D'Amore, Acting Manager s
Columbia Plant j,
=MD:lb WP2334E:3
!1 --
Attachme' t: Appendix A n
!.I-8505200360 850412 PDR ADOCM 07001151 C
PDR iJ
= "
, $ * ' ' April -4,1985 70-1131/85-02 APPENDIX A ESTINGHOUSE RESPONSE TO NRC NOTICE OF VIOLATION Item:
Failure to = maintain cartridge filters within the gross weight limit specified by procedure.
(1) The violation is ' correct as stated in your Notice of Violation.
-(2) The violation was caused by a defect in the weighing scale and failure of ~ the operator to follow Operating Procedure CSR 5015,
" Washing Machine".
-(3) L The operation was immediately suspended and the cartridge filters were transferred from.the hopper to other containers for reweighing.
The inoperative scale was replaced and the new scale calibrated on February 20, 1985.
This scale was placed under a control format which assures routine calibration and documentation.
Furthermore, the responsibility for-all Conversion Area scale documentation and control was assigned to an individual Conversion Area supervisor.
All applicable operators were reinstructed on procedures used in this operation.
(4) An. audit was performed during February to determine weighing scale operability and calibration for ' other scales in the Contamination Controlled Area. No significant deviations were observed.
(5) Full compliance has been achieved.
WP2334E:3p.2 p-L t
I