ML20127E005

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs,Revising Surveillance Intervals for Local Leak Rate Tests to Meet Intent of 10CFR50,App J
ML20127E005
Person / Time
Site: Millstone Dominion icon.png
Issue date: 05/31/1978
From:
NORTHEAST NUCLEAR ENERGY CO.
To:
Shared Package
ML20127E000 List:
References
NUDOCS 8505170205
Download: ML20127E005 (1)


Text

LIMITING CONDITION FOR OPERATION SURVEILLANCE REQUIREMENT e.

Local Leak Rats Tests-(LLRT)

(1) Primary containment. testable 5

penetrations and isolation valves shall be tested at a pressure of 43 psig except the main steam line isolation valves shall be tested at a pressure of 25 psig each refueling outage, at. intervals not to exceed 2 years.

Bolted double-gasketed seals -

shall be tested whenever the-seal is closed after being opened and at least once n

during each refueling outage, at intervals not to exceed 2 years.

(2) Personnel air lock door seals shall be tested at a pressure of 10 psig each operating cycle.

f.

Acceptance criteria and corrective action for LLRT:

If the total leakage rates listed below are exceeded, repairs and '

retests shall be performed to correct the condition.

O i

(1) Double-gasketedseals10%L(o (43).

(2)

(a) Testable penetrati9ns:

and isolation valves 50%

Lto (43).

(b) Any one penetration ori isolation valve except main steam line isola-:

~

tion valves 5% Lto

)

8505170205 780531 M-9 'o $

3/4 7-6 p

.