ILLINOIS POWER COMPANY SPECIAL NUCLEAR MATERIAL LICENSE No. SNM-1886 Revised License Application Attachment Q 1.

Clinton Power. Station Procedure, CPS No. 1898.00, Special Nuclear Materials Program.

5 8505170016 850506 PDR-ADOCK 07002947 C

PDR Revised-05/06/85

l ILLINOIS POWER COMPANY CPS No.

1898.00 CLINTON POWER' STATION CLASS CODE:

SNQA i

TITLE:

SPECIAL NUCLEAR MATERIALS PROGP&1 Scope of Revision:

Revised procedure to reflect the use. of FUACS for accounting and movement of SNM.

Updated position titles and revised procedure to the latest format.

Incorporated additional reporting requirements to the NRC.

Incorporated TCFs83-094, 83-536, and 83-688.

Added section for Storage of ShM.

This procedure has been completely revised.

rs 3 4 6,y

)\\'

?-(M.,.bilisv' f

.c INFORMATION ONLY

..h i

s LIST OF EFFECTIVE TCFs TCF NUMBER EFF. DATE EXP. DATE TCF NUMBER EFF. DATE EXP. DATE 9'l-3 R 9 6 - R n YLI NA LIST OF EFFECTIVE ACNs

-PREPARER C. H. Mathews GROUP SUPERVISOR [ C,

<o

. s.,

DEPARTMENT HEAD g h E ^ _

ASST. PWR. PLT ElGR, LJ INTERFACE

9.,Ne2cM4 Alast %,w CONCURRENCE
  1. cer@ G7-

/#

~/

vve#% v CCCD n,42phAMr,s.a.wLs QA CONCURRENCE rs f.'i a.e >Ss a FRG #fge. _

POWER PLANT MANAGER M7#ffi/ O ALARYGUMMITTEE -r&K_/, %

DATE 3"- 2# -P.Lt

~

~

SLAB Page No.

1 of 35 Rev. No.

1

,[.

CPS No. 1898.00 TABLE OF CONTENTS 1.0 Purpose 2.0 Discussion / Definitions 3.0 Responsibility 4.0

-Precautions 5.0 Prerequisites - None 6.0 Limitations and Actions 7.0 Materials and/or-Test Equipment - None 8.0 Procedure 8.- l Designation and Description of Item Control Areas-(ICAs) 8.2 Instructions for Completing Clinton Special Nuclear Material Accountability Forms 8.2.1 FUACS Usage and FACCTAS Development 8.2.2 SNM TRANSFER CHECKLIST Usage 8.2.3 ICA Location / Component List 8.3 Receiving Special Nuclear Material

(

8.4 Internal Transfers of Non-Exempt Quantities of Special 8.5 -

Nuclear Material Storage of Special Nuclear Material 8.5.1 Storage of Non-Exempt Quantities of Special Nuclear Material 8.5.2 Storage of Exempt Quantities of Special Nuclear Material 8.6

' Transfer of Exempt Quantities of Special Nuclear Material 8.7 Shipment of Special Nuclear Material 8.8 Physical Inventory Procedure 8.9 Nuc1' ear Material Isotopic Calculations 8.10 Records and Reports 8.11 System Review and Audit Procedures 8.12 neft, Unaccounted for, or Diversion of Special Nuclear Materials 8.13 Transfer of Inventory Responsibility

~

9.~G

' Acceptance-Criteria - None 10.0 Final Conditions - None 11.0 References i -

SLA38 Page No.

2 of 35 Rev. No.

1

CPS No. 1898.00-TABLE OF CONTENTS Continued 12.0

~ Appendices - None 13.0 Documents F

SLA38 Page No.

3 -of 35 Rev. No.

1

- -. - - - - - ~ ~ ~ - - - - - - - - - -

CPS No. 1898.00 i

1.0

~ PURPOSE This procedure =is; designed to outline the methods and procedures to be used to assure the accountability of Special.

Nuclear. Material (SNM) at.the Clinton Power Station (CPS).

2.0 DISCUSSIONS / DEFINITIONS 2.1 Discussion 2.1.1 That quantity of SNM considered reportable is~ defined in-10CFR70.54 as:

Each. licensee who transfers and each licensee who receives special nuclear material shall complete and distribute a Nuclear Material Transaction Report on.

DOE /NRC Form 741 in accordance with printed instructions for completing the form whenever he transfers or receives a quantity of special nuclear material of 1 gram or more of contained uranium-235, uranium-233, or plutonium, 2.1.2 Physical responsibility for SNM ' passes ' to C

CPS as soon as the SNM is received at a J

security controlled area.

2.1.3 An independent check of the CPS SNM program is provided by the Supervisor of Nuclear Fuel Cycle.

He is-appointed by and reports to the-Manager of Nuclear Station Engineering Depa.-tment.

2.1.4 The SNM_ program described in this procedure shall follow-the provisions of the SNM license.

2.2

-Definitions 2.2.1 Special Nuclear Material - (1) Plutonium, Uranium 233, Uranium enriched in the isotope 233 or in the isotope 235', and any other. material which the Commission, pursuant to the provisions of Section 51 -

of the ACT, determines to be Special Nuclear Material, but does not include source material; (2) any material artificially enriched by any of the

foregoing, but does not include source material.

e i

SLA38 Page No.

4 of 35 Rev. No.

1

C, CPS No. 1898.00-

,1

('

2.2.2 The following items at CPS contain special nuclear material (SNM):

a)

Fuel Assemblies and Fuel Bundles b)

Source Range Monitor (SRM) detectors

- c)

Intermediate Range Monitor (IRM)

= detectors d)

Local Power Range Monitor (LPRM) detectors e). Traversing In-Core Probe (TIP)

, detectors f)

Neutron / Alpha sources containing SNM.

2.2.3 Tagboards - Tagboards are located in the control room and at the individual Item Control Areas.

They show the location of fuel assemblies by tags on hooks for their storage locations.

The tag shall bear the -

bundle serial number.

2.2.4 FUACS - Fuel Accountability System - A 7(

system of computer codes (FUELCOUNT, FUELCHECK, FUELMOVE) designed to provide a c6mplete capability in fuel and core component accounting.

This capability includes item placement history, SNM accounting, and' location content histories.

In addition, to support the site' staff during the refueling outage, the FUACS package provides the. capability to generate item movement instructions necessary to reconfigure the core.

2.2.5 FACCTAS - (Fuel and Core Component Transfer Authorization Sheets) - The FUACS generated material movement instructions that should be used for moving fuel, blade guides, nuclear instruments, and neutron sources while these items are on site.

The FACCTAS may be used for movement of exempt quantities of SNM.

k SLA38 Page No.

5 of 35 Rev. No.

1

=

CPS Ho. 1898.00

.L 2.2.6 Item Control Areas (ICA) - Areas

[

established for physical and l

=

n administrative control of SNM.

Each ICA is an identifiable physical area such that the nuclear fuel assemblies and nuclear instruments being moved into or out of the ICA can be counted and identified.

Control of fuel into and out of ICAs shall be by item and serial number.

2.2.7 FUELCOUNT - A fuel accountability data storage and retrieval system.

FUELCOUNT maintains current status and historical information on fuel bundles, channels, control rods, nuclear instruments and other core related components.

Current status and content history information are recorded for the reactor core, fuel pool, fuel vault and the associated miscellaneous locations where the core-related components may reside.

Using a computer terminal, personnel can request FUELCOUNT to display on the screen or write to the line printer the current status and location of any or all accounted items, the contents of any or

(

all locations, or complete historical reports for the items or locations.

FDELCOUNT maintains inventory, material balance and transaction records for all items containing Special Nuclear Material (SNM).

These items may be grouped into separate accounts for reporting purposes, and each account may be identified by the Reporting Identification Symbol (RIS)-

assigned to CPS.

FUELCOUNT can rapidly produce up-to-date reports which contain the information required for NRC/ DOE forms 741 (Nuclear Material Transaction Report) and 742 (Matarial Status Report).

FUELCOUNT, therefore, helps meet the requirements of 10CFR70, Sections 70.51 through 70.56.

k SLA38 Page No.

6 of 35 Rev. No.

1

2.. -

__...-..a._ _.

CPS No. 1898.~00 1

-((

2.~2.8

-FUELCHECK - A FUACS module that performs.

configuration validation and verification 4-of auxiliary-data files.

Operating in the

^

batch mode,_FUELCHECK examines the content of_ auxiliary files used within_FUACS.

Any-L' :

' erroneous data base, or item and location 1

conventions established in FUELCOUNT, is indicated with error codes.

Several forms r

of content display summaries are available

'F to summarize information'on the files.

In addition, data.from the -files may be processed to develop a FACCTAS or for automated updating of the data base.

2.2.9 FUELMOVE - This FUACS module enables the i

generation of and management of a data j.

file containing item movement' instructions.

These movement instructions, or ' transactions', when properly applied to an initial item configuration will rearrange the items to form.a desired final configuration.,The' application of the transaction file is most useful, but not limited to, reconfiguration of core components during k

refueling.

2.2.10 Exempt Quantities of SNM - Those. items-i that contain'less than 1 gram of SNM (e.g., LPRM' detectors, TIPS, IRMs, and SRMs).

2.2.11 Non-Exempt Quantities of SNM - Those items-that contain one gram or more of SNM l

(e.g., fuel bundles).

2.2.12 Source Material - Uranium or' thorium, or any combination thereof, in any physical-or chemical forms or ores which contain by weight one-twentieth of one percent (0.05%) or more of (a) uranium, (b) thorium or (c) any combination'thereof.

Source material does not include special oh

-nuclear material.

k:

N

> SLA38 Page No.

7 of 35 Rev. No.

1

- w -. -.

CPS No. 1898.00

[

3.0 RESPONSIBILITY 3.1 The Power Plant Manager.is responsible for the overall-control'of special nuclear. material at CPS and implementation of-this.. program which includes the following duties:

3.1.1 Approving the NRC Material Transfer Forms and Status Reports.

3.1.2 Initiating special audits and other-actions, as necessary, for safeguarding SNM while it is. on site.

3.1.3.

Assuring that the SNM Custodian has fulfilled the requirements of CPS No.

1131.02, EMPLOYEE SCREENING.

3.1.4 Notifying the NRC of lost, unaccounted' for, theft of, or diversion of special nuclear materials and assuring the required follow-up reports are transmitted.

3.2 The Supervisor - Technical shall be responsible for

^

_f' review of this program and for preparing the FACCTAS and the SNM TRANSFER CHECKLIST, CPS No. 1898.00C001, 0'

as needed.

The Supervisor.- Technical shall appoint.a SNM Custodian who will:

3.2.1 Ensure that records concerning the receipt,- inventory, disposal, accidental loss, and transfer of SNM are sent to the Central File, as' required.

4 3.2.2 Calculate, or cause-to be calculated, the isotopic content of.the fuel.

3.2.3 Authorize transfers of SNM.

3.2.4 Conduct or coordinate the SNM inventories and maintain accountability.

3.2.5 Prepare the NUCLEAR MATERIAL TRANSACTION REPORTS (DOE /NRC Form 741) and the MATERIAL STATUS REPORTS'(Form NRC 742).

3.2.6 Coordinate the receipt and shipment of fuel and ensure that the proper forms are received and prepared.

k l

SLA38 Page No.

8 of 35 t-Rev. No.

1

4

=a.ede+6 s e e We sense m e4EupWW*"*

CPS No. 1898.00 f

3.2.7 Ensure that the FUACS data base is maintained current and control who may.

change the data base.

3.2.8 Coordinate the acquisition of all.SNM and source material, and verify that the shipment is within our. licensed limits.

3.3 The Supervisor - Radiation Protection is responsible for part of the care of SNM due to its radioactive nature.

He is responsible for radiation surveys of material upon receipt and shipment and ensuring that the materials are stored in properly posted areas for radioactive materials.

He may also receive subcustody of SNM-from the SNM Custodian.

3.4 The Supervisor - Operations is responsible for the physical transfer of the fuel outside of shipping containers, ensure that each item is moved properly according to the prepared checklist, and ensure the tagboards are updated.

3.5 The Assistant Power Plant Manager - Maintenance (APPM - M) is responsible for interface with the Purchasing Department for receipt and procurement of SNM and shipping services.

He is responsible for

{

handling shipping containers, and the transfer, installation, and removal of fission detectors.

He is responsible for the storage of unirradiated exempt quantities of SNM while in the storeroom.

3.6 The Supervisor - Plant Protection is responsible for providing protection to prevent the unlawful diversion of SNM while within the protected area.

4.0 PRECAUTIONS 4.1 Provide solid stream nozzles for all fire hoses in fuel storage areas when new fuel is stored in the New Fuel Vault and the covers are off, or dry in the upper containment pool racks.

This is to prevent the fuel from being subjected to a fog which could cause an accidental criticality.

4.2 If fuel is to be stored dry in the upper containment pool, then the containment spray mode of RHR shall be tagged out.

4.3 Combustible material shall not be allowed in the New Fuel Vault when fuel is in the New Fuel Vault.

k

?

l SLA38 Page No.

9 of 35 Rev. No.

1

CPS No. 1898.00_

h 5.0 PREREQUISITES None 6.0 LIMITATIONS AND ACTIONS 6.1 The SNM at CPS shall be safeguarded in a manner to prevent unlawful diversion.

SNM when in storage shall be stored under lock and key.

6.2 Internal transfers of fuel shall only be made with a movement-sheet from the time the fuel is removed from the box (i.e., the FUACS generated FACCTAS, or a SNM TRANSFER CHECKLIST).

6.3 There shall be a maximum of three fuel bundles / assemblies not in a storage location at a time.

7.0 MATERIALS AND/OR TEST EQUIPMENT None 8.0 PROCEDURE 8.1 Designation add Description of Item Control Areas (ICAs) 8.1.1 Item Control Areas (ICAs) shall be established for physical and administrative control of non-exempt SNM.

The boundaries of ICAs are intended to provide points for movement and accountability of SNM subject to this procedure.

The ICAs at the Clinton Power Station shall be:

a)

Reactor core b)

Spent Fuel Pool including transfer pool, inclined fuel transfer mechanism c)

Upper Containment Pool d)- New Fuel Storage Vault l.

SLA38 Page No.

10 of 35 Rev. No.

1

,1.,

CPS No. 1898.00

(

e)

Fuel building' floor El 755) f)

Temporary storage areas as designated in writing by the SNM Custodian.

8.1.2 Non-exempt SNM shall be stored within designated ICAs.and may not be -

transported across the boundary of any ICA or to a new location within an ICA without completion.of a FACCTAS or a SNM TRANSFER CHECKLIST.

8.2 Instructions for Completing Clinton Special Nuclear Material Accountability Forms FACCTAS and ONM TRANSFER CHECKLISTS, may be used interchangeably provided the page numbers are kept sequential.

8.2.1 FUACS Usage and FACCTAS Development NOTE Refer to the FUACS Manuals, as needed, for information on the operation of FUACS.

](

8.2.1.1 Routine Use 8.2.1.1.1 SNM composition and exposures for new and spent fuel should.be updated upon arrival to the site and when discharged from the core.

The data for new SNM may be found on the shipping papers or DOE /NRC Form 741.

The isotopic-composition and exposure for each fuel bundle may_be found in the process computer.

As a minimum, the composition and exposures shall be updated on March 31 and September 30-of each year for fuel not in the core to facilitate the reporting requirements of DOE /NRC Form 742.

8.2.1.1.2 Periodically, SNM storage location edits i

may be obtained for placement in the

~ Central File.

Initiate the master menu F

option to have the edit printed on microfiche.

8.2.1.2 Pre-Outage Activities to Generate a FACCTAS 4

SLA38 Page No.

11 of 35 Rev. No.

1 L

CPS No. 1898.00

{

8.2.1.2.1 The following activities are required

~

before writing fuel movements:

a)

Enter interim and target status configurations b)

Update item positions to pre-shuffle

. status c)

Generate a current status file d)

Verify the current status file with FUELCHECK e)

Copy a tagboard file from the new current status file 8.2.1.2.2 While signing onto FUELMOVE, you may generate a transaction file or use an existing one.

If you must generate a new transaction file, it will take about 15 minutes.

8.2.1.2.3 Write fuel moves using.the ' Manual Data Entry' or the "Autogeneration of Transactions' (Autogen) selections.

Page numbers for the FACCTAS should begin with

/

the year i.e.

'78', followed by the page sequence number beginning -with

'l' in the beginning of the year and all moves continuin the year.g in sequence until the end of 8.2.1.2.4 Verify the transaction file with FUELCHECK using the transaction file audit.

If a FACCTAS and/or location edits are desired, those options should also be chosen.

8.2.1.2.5 The FACCTAS shall be approved by the SNM Custodian.- An SRO approval shall also be required when loading / unloading fuel into the core.

k SLA38 Page No.

12 of 35 Rev. No.

1

'~

~

~

~~

i pg

?..

I

'y

?

CPS No. 1898.00 i

p 8.2.1.2.6 For fuel movement, two copies of-the-4 J(?

a? proved FACCTAS shall be forwarded to the Shift Supervisor, one for the SRO, or SRO Limited to Fuel Handling,' supervising the fuel movement, and the other for the. Main.

-m

  • Control Room.

If the FACCTAS is to be N

used for movement of exempt. quantities of-SNM or for movement of other nonfuel-internals (i.e., blade guides (BG),

a control rods (CR), channels), then only

' one copy is required, and it shall be sent to the individual supervising the movement.

8.2.1.3 Usage During an Outage.

8.2.1.3.1 Modify the. transactions file and'FACCTAS, as necessary, with the FUELMOVE/Autogen and FUELCHECK.

-8.2.1.3.2 In order to update the FUELCOUNT data base from a FACCTAS, generate a FUELCOUNT Update File with FUELCHECK using information from the checked off-FACCTAS and the tagboard file.

For. updating FUELCOUNT from a SNM TRANSFER

(-

CHECKLIST each move must be manually entered.

The FUELCOUNT data base files -should be d

u? ated within one' week of the moving of the items.

Although'a per shift update would be helpful if many items -are being moved and/or a revised FACCTAS is G

required.

L t.

8.2.1.3.3 The.SRO,-or SRO Limited to Fuel Handling,

[-

supervising the transfer shall verify'that f

b each transfer is correct.by initialling ~

each step as it is completed.

p 8.2.1.4 Post Outage Activitics 8.2.1.4.1~

Complete the FUELCOUNT data base updates started in Section 8.2.l'.3.2.

L 8.2.1.4.2 A status file comparison of the' data base

-should be performed to' compare the as loaded configuration with the target i

configuration.

t.

. [

n(

]

SLA38 Page No.

13 of 35 W

Rev. No.

1 1

2

.. a

_ ~. _

C-IL

' CPS No. 1898.00 T8.2.1.5 Data Verification AnLitem and. location analysis of the data 4

9 base'should be done by writing a new

v' current status file -then using FUELCHECK to verify that there are no. mistakes.

1

'This may-be done'following any update to

<<C FUELCOUNT. and should be done following an outage.

3-8.2.2-SNM TRANSFER CHECKLIST Usage A SNM TRANSFER CHECKLIST may1be used for movement of any SNM, in lieu of a FACCTAS.

Use of a SNM TRANSFER CHECKLIST may

. require more-work r.o complete than a FACCTAS;.therefore, the SNM TRANSFER CHECKLIST is best suired for moving small numbers of items, incorporating moves into FACCTAS (verify that this does not interfere with the FACCTAS movements), or when receiving new fuel.

8.2.2.l SNM TRANSFER CHECKLISTS should be sequentially numbered with FACCTAS.

Enter-the year-sequence,-such as 78-1, 78-2, etc.

The purpose of this numbering scheme

'{?

is to show that no checklists are missing from.the records.

8.2.2.2 The initiator should be a member of the Technical ~ Department Nuclear Group, or a designee.

The-initiator shall enter the j ob - name and page - number.

The 7 age numbers are provided to aid-in keeping the pages of a particular job together for the operator's convenience.

Clearly describe the material to be transferred.

Whenever possible, the smallest physical unit (e.g., one fuel assembly) shall be-identified by serial number.

8.2.2.3 Enter the Location from which the-SNM is to be moved.

W

~8.2.2.4 Enter the Location to which the SNM is.to be moved.. The propeE orientation NW, NE,-

SE, or SW shall be entered when required.

Each intermediate stop where an incividual' operation is performed should be designated.

(

SLA38 Page No.

14 of 35 Rev. No.

I

w. _. _ -

.s,

+,

CPS-No. 1898.00 8.2.2.5 The initiator shall sign the appropriate

'L line.

A line is also provided for a member of the Nuclear Group to check the correctness of the prepared moves.

Checking is recommended.

8.2.2.6 The SNM TRANSFER CHECKLIST shall now be forwarded ~to the SNM Custodian for

. approval.

'An SRO approval shall also be'

-required when loading / unloading fuel into the core.

8.2.2.7 For fuel movement, two copies of.the approved SNM TRANSFER CHECKLIST shall be forwarded to the Shift Supervisor, one for the SRO, or SRO Limited to Fuel Handling, supervising the fuel movement and the other for the Main Control Room.

If the

- SNM' TRANSFER CHECKLIST is to be used for movement of exempt quantities of SNM or for movement of other.nonfuel internals (i.e., blade guides (BG), control rods (CR), channels), then only one copy is required, and it shall be sent to the individual supervising the movement.

j 8.2.2.8 The SRO, or SRO Limited to Fuel Handling, supervising the transfer shall verify

-(

that each transfer is correct by initialing each step.as it is completed.

8.2.2.9 The completed' checklist shall be returned to the SNM Custodian.

8.2.3

  • ICA Location / Component List ICA Location / Component Lists provide a listing of contents at a specified ICA used for component and/or fuel' storage (grid positions.for vaults, pools, core, etc.)

Edits of ICA Location / Component Lists may be obtained from the FUELCOUNT data base.

8.3 Receiving Special Nuclear Material

'8 3.1 The SNM Custodian shall ensure that sufficient personnel will be available to receive the SNM upon its scheduled arrival i

at the Clinton site, i

l

.I I

SLA38-Page No..

15 of 35 Rev. No.

1

=..... _

o+

~y,

-w.

.,n

-nn-w,,

_,.4.s,-wse-,-.s

,o_a----.-m--,,,,.,.m.,w-.-

e--,.-,-

L J

CPS No;-1898.00.

8.3;2 The SNM Custodian shall notify the

71 Supervisor - Stores, and the Supervisor -

(___

Radiation Protection, or their designees

~ ~ '

in advance when SNM is expected'to1 arrive in accordance with CPS No. 1907.01, RECEIPT OF RADIOACTIVE MATERIAL.

8.3.3-The'SNM Custodian shall arrange with the Supervisor - Plant Protection, or his designee, for the required security of the nuclear material shipment upon its y

-arrival 8.3.3.1 If a new fuel shipment, of greater than 10,000-grams, fails to arrive after.the.

estimated arrival time, the SNM Custodian shall initiate a CPS CONDITION REPORT,. CPS No. 1016.01F001, and-immediately begin a trace investigation of the shipment to determine if any is lost or unaccounted for.

Also, immediately notify the NRC Operations Center via the Emergency Notification System as soon as possible, and in all cases in one hour, and document on a Record of Coordination.

A written report shall~ follow within.15 days, to Region III-per Section 8.12.

f..

(10C7R73.71(a)).

' 8.3.3.2 In the event a shipment of SNM of greater

-than 10,000 grams of U-235, fails to arrive after the expected arrival time, or.

if there is a discrepancy in the amount'of-SNM delivered,.the SNM Custodian should notify:

- Power Plant Manager Supervisor - Stores Supervisor - Nuclear Fuel Cycle Shipper Supervisor - Radiation Protection 8.3.4 Upon arrival of a SNM shipment at the site, security shall notify the Supervisor

- Stores, the SNM Custodian, Supervisor -

g

^

Radiation Protection, and'the Supervisor -

Plant Protection or their designees before the SNM is brought on site.

SIJ38 Page No.

16 of 35 Rev. No.

1

-4

--es4*-

n aem ay q,.

y+e.4 y

-q p-sww-=%q ^ Wes

,-Dp+v-'

.-s.gw e,w-g,

-,es,-*%

vee-vy-e-w--6---

wrW=

wwe-- -.

v w ee w'rww-*-

a- - - - - - - - -w-ww

CPS.No. 1898.00 8.3.5 The shipping crates of SNM shall-be

, (,

promptly counted and confirmed to be

.\\'

correct by the SNM Custodian or his designee.

8.3.6 Radiation Protection personnel shall

-monitor the unloading per RECEIPT OF RADIOACTIVE MATERIAL.

The shipment should be placed under lock and key.or constant surveillance, -as directed by the SNM Custodian or his designee until its-contents is verified and' stored in an appropriate ICA.

8.3.7 The NUCLEAR MATERIAL TRANSACTION REPORT (DOE /NRC' Form 741) should be received in three copies from the shipper, if-the shipment contains greater than 1 gram of SNM.. It shall-be promptly completed after receipt of nuclear material.

Copies should be verified by the SNM Custodian, or his designee, and marked per NUREG BR 0006.

Verification should include a check of the DOE /NRC Form 741 against the shipping papers presented by the carrier's driver and the shipping containers received.

The Power Plant Manager should (f

then sign.the DOE /NRC Form 741 and enter

.\\

the date the SNM shipment was received.

The DOE /NRC Form 741.shall be distributed as illustrated in Figure 1.

8.3.8 The SNM Custodian or designee shall conduct a piece count and verification of the component serial numbers, with those on the shipper's documents.

This'should be done within two working days'of receipt.

The tamper seals shall also be checked.

Immediate steps shall be taken to reconcile any differences in piece count totals or identification numbers.

8.3.8.1 This verification shall be done at receipt if there is reason to believe the SNM has been lost or stolen.

i

.SLA38 Page No.

17 of 35 i'

Rev. No.

1

. CPS No. 1898.00 8.3.8'.2 If the piece count verification indicates

.(

that SNM has been stolen or if SNM is

(.

unaccounted for, initiate a CPS CONDITION-REPORT, and notify NRC Region III at (312) 790-5500 immediately and document on a Record of Coordination.

A follow-up report.shall be due in 15' days per Section 8.12.

y d

h SLA38-Page No.

18 of 35 j'

Rev. No.

1

r

.n f

oo

'l i

C4 C3 C2 Cl

~b s

se Form 741 Mail per Shipper SNM Supervisor Super-from shipper NUftEG/

Records Nuclear Fuel visor -

BR-0006 Central Files Cycle Stores N

Ho 1

tn O = original C = Copy

n m

n yy CPS as Receiver m

g l

DOE /NRC Form 741_ Distribution g

z 2

~

00 W

00 c

W On.

(A W

.i t

j i

~

CPS No. 1898.00

f 8.3.9 Copies-of bills of lading, shipping memos,

.(

' packing lists, the DOE /NRC Form 741, and other ship? ng forms accompanying the i

shipment should be given to the Storeroom.

8.3.10 A FACCTAS should be developed or a SNM TRANSFER CHECKLIST, may be filled out indicating transfers between the shipping container and the initial storage ICA. ~

The SNM identification number should be recorded on the SNM TRANSFER CHECKLIST as the incoming SNM is identified or in advance when the identification numbers are available.

8.3.11 The normal receipt processing should be conducted by the Storeroom in accordance with CPS No. 1513.01 HANDLING, STORAGE AND SHIPPING.

8.3.12 The Technical Department should have three.

tags prepared for each fuel bundle received to be used in conjunction with the local Tag Boards.

The tags should be placed on the Tag Board to correspond to the position of the fuel assemblies in the New Fuel Storage Vault or Spent Fuel

(

Storage Pool.

~ ~ ~

8.3.13 The FACCTAS or the SNM TRANSFER CHECKLIST, completed for receipt of SNM, shall be routed to the SNM Custodian for distribution and filing, per Section 8.10.

8.3.14 The SNM Custodian should ensure that the NUCLEAR MATERIAL TRANSACTION REPORT (DOE /NRC Form 741) and the Packing List are in agreenent.

8.4 Internal Transfers of Non-Exemot Quantities of Special Nuclear Material 8.4.1 Transfers of fuel into, out of, or within the New Fuel Storage Vault, Spent Fuel Pool and the Upper Containment Storage Pool shall be accomplished upon authorization of the SNM Custodian, or appointed member of the Technical Department Nuclear Group.

i t

SLA38 Page No.

20 of 35

(

j Rev. No.

1

=

CPS No. 1898.00 8.4.2

-Transfers of. fuel out of or within the 2{a).

. core ICA shall be accomplished only upon

.E authorization of the SNM Custodian and an

- SRO. -

8.4.3 The SNM Custodian shall notify in. advance Radiation Protection Supervision of any movement of fuel.

Radiation Protection shall ensure that the area is posted, per-CPS No. 1024.03, STATION RADIOLOGICAL AREAS, ACCESS CONTROL AND DESIGNATIONS.

8.4.4 The FACCTAS, or appropriate checklist, should be prepared in advance by the Technical Department Nuclear Group for movement of fuel across or within any.ICA boundaries.

8.4.4.1 Movement steps should be followed in order for each job, with the exception of the -

FACCTAS where moves in the Containment and Fuel Building may be done as independent as-practical.

NOTE There shall be a maximum of'three-fuel

(

bundles / assemblies not in a storage 16 cation'at a time.

8.'4.4.2 In special cases, for example, when'the order of item arrival or channel serial numbers are not known'in advance, the SNM TRANSFER CHECKLIST may b~e written by Technical Department personnel, Hor designees, as the moves are made and approved later by the SNM Custodian.

8.4.5 The SRO, or SRO Limited to Fuel Handling, responsible for the movement of SNM shall certify by initialing the checklist that the movement has been verified.

8.4.6 Field changes to FACCTAS and the. approved checklists may be made if the intent of the transfer is not changed; therefore, this means corrections to discovered errors or a change-in the sequence of moves to help streamline the transfer.

-k SLA38

.Page No.

21 of 35 Rev. No.

1 i.

n. -

+

.s-

^*

{

CPS No. 1898.00 r

8.4.6.1 zThese changes may be made by preparing =a

'C new FACCTAS, or by changing.the new SNM-

-X TRANSFER CHECKLIST and numbered XX-XXa~, b, etc.-indicating the page of revision, where XX-XX is the_page being revised.

8.4.6.2

' Changes.to a.FACCTAS, or SNM TRANSFER:

CHECKLIST, may be made by a member of the Technical Department Nuclear Group and an SRO.

8.4.7

- Whenever.SNM is transferred from one ICA.

to another,_the serial number of.the item-should be verified if legible.

8.4.8 The-Tag Boards should be updated by the Operations Department for each move by-adding, removing, or transferring the associated fuel assembly tags..

8.4.9 Upon completion of~a fuel transfer,'the FACCTAS or SNM TRANSFER CHECKLIST, and all changes, should be routed to the SNM Custodian for filing, per Section.8.10.-

The SNM Custodian shall'also ensure that-the FUELCOUNT data-base 'is updated per Section 8.2.1.3.2.

8.5.

Storage of Sp4cial Nuclear Material

. 8.5.1 Storage of-Non-Exempt Quantities of Special-Nuclear Material 8.5.1.1 Fuel shall be stored in permanent ICAs that meet the requirements for Level C components per ANSI N45.2.3-1973, GE design specification 22A4478'and CPS No.

1019.02, SYSTEM CLEANLINESS.

The storage-requirements for this shall be'as follows:

SLA38 Page No.

22 of-35 L

Rev. No.

1

--Mr*Wv-d-

dr

%4

,.s~e-ume geevy,i A -wwyg7 v w W4,mp-a.---.pm e v s

p -- M ew+y wm y grMtMegrWH.we+-*-g-

__Www q wwwwwwwwgerg-M-'V-p,e-gy-M'-Wv---

y4W

CPS No. 1898.00

+*

a)

If new fuel is to be stored in the New

, ()-

Fuel Storage Vault (vault) then the metal cover shall be in place except during fuel movement.

When the vault is open, the fire hoses in the area shall be affixed with. solid stream nozzles to prevent a fog or mist.

The vault will remain suberitical if flooded.

Criticality monitors shall be operable for dry storage.

Also, no combustible material shall be allowed in the vault when new fuel is in storage there.

b)

New fuel may be stored dry in the Spent Fuel Pool (SFP) provided no spent fuel is present and if it is covered with a non-flammable cover to protect the fuel.

New fuel may also se stored wet in the SFP.

Spent fuel shall be stored wet in the SFP.

Criticality monitors shall be operable for dry storage.

If fuel is stored wet in the SFP, then the water chemistry shall be checked per CPS No.

6001.01, SAMPLING AND ANALYSIS REQUIREMENTS.

(-

c)

New and spent fuel may be stored in the Upper Containment Poof (UCP) during refueling operations.

Water chemistry shall meet the requirements of SAMPLING AND ANALYSIS REQUIREMENTS.

e New fuel for the initial fuel load may be stored dry, provided the fire hose nozzles are of the stream type and the containment spray mode of RHR is tagged out, to prevent a fog or mist on the refueling floor.

d)

New fuel may be stored in its shipping crate.

If fuel is to be stored in its crate, the area shall be posted per STATION RADIOLOGICAL AREAS, ACCESS CONTROL AND DESIGNATIONS.

NOTE Fuel shall not be stored hooked to a grapple.

4 SLA38 Page No.

23 of 35 Rev. No.

1

CPS No. 1898.00 8.5.1.2' In the event of an accidental criticality, E(J,

immediately' evacuate the' area and notify o

n\\1 the Shift / Asst. Supervisor.

A CPS CONDITION REPORT shall be initiated so that Region-III of the NRC can be notified iL immediately by telephone-(312) 790-5500, f

telegraph, mailgram, or. facsimile.

8.5.1.3 Item Control Areas when containing " fuel shall be classified as " vital areas as

(

. !1 defined in 3.4 Vital Area,,of American National Standard for Industrial Security for Nuclear Power Plants N18.17-1973'and implemented-per the Security Plan.-

efore B

the initial fuel load, the Security Plan may not be fully implemented.

In this i

case, the safeguards requirement of the fuel storage license will be implemented.

8.5.2 Storage of Exempt Quantities of Special Nuclear Material

.t Exempt quantities of SNM shall be stored

~

in controlled access areas but need not be in an ICA.

The area shall be roped off i'

and posted, as necessary, per CPS No.

1024.03, STATION RADIOLOGICAL AREAS,

[-

ACCESS CONTROL AND DESIGNATIONS.

.\\

Documentation for' item locations shall be through the use of FUACS, SNM TRANSFER CHECKLIST, or by memo to the SNM-

-3 Custodian.

q 8.6

-Transfer of Exempt Quantities of Special Nuclear Material

[

NOTE Items'containing less than 1 gram of SNM do not need to be stored in an item control area.

A locked area L

is sufficient, see Section 8.5. A FACCTAS or SNM' TRANSFER CHECKLIST is'not necessary but may be used to aid in~the transfer.

The FUELCOUNT data base should be updated for these items or the transfer may be documented by a memo to the~SNM Custodian.

Isotopic calculations need not be performed.

8.6.1 Transfers of exempt c uantities of SNM shall be.accomplishec, upon authorization of the SNM Custodian.

.I i

!. (-

.SLA38 Page No.

24 of 35 Rev. No.

1

]

~

c

.[

CPS No. 1898.00

.8.6.2 Radiation Protection Supervision shall Lbe.

C notified in advance of any movement of-SNM and provide proper posting per CPS No.

1024.03, STATION RADIOLOGICAL AREAS, ACCESS CONTROL AND DESIGNATIONS.

8.6.3 If a FACCTAS or SNM TRANSFER CHECKLIST is used, the Supervisor-responsible for the movement-of-exempt. quantities of:SNM shall certify by signature on the. checklist that the movement has been veri.fied.

If they are not used, a memo shall be sent to the SNM Custodian describing the movement.

8.6.4 Field changes to the approved FACCTAS or SNM TRANSFER CHECKLIST may be made as-necessary by the person supervising the movement.

These changes may be made by producing _ a new FACCTAS or producing.a new SNM TRANSFER CHECKLIST, numbered XX-XXa, b, etc., indicating the page of revision, where XX-XX is the page being revised.

8.6.5-Upon completion of_a transfer, if they are C

used, the FACCTAS or SNM TRANSFER CHECKLIST and all' changes should be routed to the SNM Custodian for filing.

The SNM Custodian shall also ensure that the FUELCOUNT data base is updated.-

8.7 Shipment of Special Nuclear Material 8.7.1 Before transferring Special Nuclear Material, the receiver's license shall be verified that it authorizes receipt of the type, form, and quantity of SNM to be.

transferred.

The following methods for verification may be used (10CFR70.42):

a)

The SNM Custodian, or designee, may review a current copy of the receiver's specific license, or registration certificate, or k

SLA38 4

Page No.

25 of 35 Rev. No.

1

m CPS No. 1898.00 b)

The SNM Custodian, or designee, may C

review a written certification by the receiver that he is authorized by license or registration certificate to receive the type, form, and quantity of SNM to be transferred, specifying the license or registration certificate number, issuing agency and expiration date, or c)

For emergency shipment, the SNM Custodian, or designee, may accept oral certification by the receiver that he is authorized by license or registration certificate to receive the type, form, and quantity of SNM to be transferred, specifying.the license or registration certificate number, issuing agency and expiration date -

PROVIDED, that the oral certification is confirmed in writing within 10 days, or d)

The SNM Custodian, or designee, may obtain other sources of information compiled by a reporting service from official records of the Commission or

-.(..

State as to the identity of licensees the licensing agency of an Agreement and the scope and expiration dates of licenses and registrations or e)

When none of the above methods are available, or if the SNM Custodian, or-designee, desires to verify that~

information received by one of the above methods is correct or up-to-date, he may obtain and record confirmation from the NRC or the licensing agency of an Agreement State that the receiver is licensed to receive the SNM.

8.7.2 The SNM Custodian should provide information to the Supervisor - Stores to allow arrangement for a qualified carrier and establishment of shipment routing.

SIJJ8 Page No.

26 of 35 i

Rev. No.

1

n CPS No. 1898.00 8.7.3 The SNM Custodian shall ensure that the necessary NUCLEAR MATERIAL T'lANSACTION 3

REPORT.(DOE /NRC Form 741) is prepared for shipment of SNM of greater than-1 gram per N M G BR-0006.

The Power Plant Manager-will then sign and enter the date on the form.

The DOE /NRC Form 741 shall be distributed per Figure 2.

The form must be dispatched on the same' day the material is shipped.

8.7.4 Prior to shipment of SNM,-the'SNM Custodian shall consult with the Supervisor - Radwaste to ensure conformance to CPS No. 1913.00,

. RADIOACTIVE MATERIALS SHIPPING MANUAL, and to supply information required for the shipment of fissile material.

8.7.5 For the shipment of spent fuel, the fuel cask shall be designed to accommodate the normal and accident conditions described in 10CFR71.

Also, the overland offsite transportation of the cask will conform to trans ortation rules and regulations of 49CFR 73.

.(

8.'7.6 When loading fuel bundles into the shipping cask, the fuel bundle ID numbers shall be verified visually with the numbers listed on the SNM transfer form and~the shipping list.

The verification shall be documented by a signature on -the appropriate form.

NOTE There shall be a maximum of three fuel bundles / assemblies not in a storage location at a time.

8.7.7 The Tag Boards should be updated by the Operations Department for each and every move when fuel has been moved.

8.7.8 The SNM Custodian will release the shipment to the carrier by signing the RADIOACTIVE MATERIAL SHIPMENT RECORD,' CPS No. 1913.00F001.

k[

SLA38 Page No.

27 of 35 Rev. No.

1 i

=. '..

t CPS No. 1898.00 8.7.9 As soon as the carrier leaves the C'.

protected area, the SNM Custodian, or designee, shall notify the consignee by telephone, telegraph, or teletype, of the time of departure of the shipment, the method of transportation-(including the name of the carrier), estimated time of arrival, and document on a Record of Coordination.

8.7.10 copies of bills of lading, shipping memos, packing lists, the DOE /NRC Form 741, and other shipping forms accompanying the shipment should be routed to the storeroom before transmittal to the Central File.

8.7.11 The FACCTAS or SNM TRANSFER CHECKLIST completed as a result of shipping operations shall be routed to the SNM Custodian for updating of the FUELCOUNT data base and filing.

SLA38 Page No.

28 of 35 Rev. No.

1

7 _. -

m 11 1

}

C6 t

1 C5 C4 l

C3 C2 C1 I.

0 g

Receiver Mail per SNH Super -

Supervisor NUREC/

g*ecord{

visor Nuclear Fuel y

BR-0006 y[{a Stores Cycle g

s r

g s,

g O = Original C2 N

f I

C = Copy

}

o N

. o m

o t

< oo 9

i o

m z z 2

.o

.o

.o DOE /NRC Form 741 i

h CPS as shipper' I

'o w

o rw o

V

=

e I

9 CPS No. 1898.00

. 8.8 Physical Inventory Procedure

(-

8.8.1 A complete serial number inventory of non-exempt items in the possession of CPS including both a piece count and serial number verification of the New Fuel Storage Vault and Spent Fuel Storage Pool should be conducted after a refueling outage and one other time during the operating cycle or when required by the Power Plant Manager.

The core-shall be - -. - -

2 verified after refueling / fuel movements are complete per CPS No. 2209.01, CORE VERIFICATION.

Errors found shall be corrected using a new FACCTAS or SNM TRANSFER CHECKLIST and then reverified.

A piece count of the New Fuel Storage Vault, Spent Fuel Storage Pool, and core (if it is visible) shall be made at least every.6..

months and compared with the FUELCOUNT Location Current Status.

The results of the inventories shall be reported to the Power Plant Manager and the Supervisor of Nuclear Fuel Cycle.

8.8.2 A complete piece count inventory of,all.__

unirradiated exempt items in the C-possession of CPS shall be made at least every 6 months.

The results of this inventory shall be reported to the Power Plant Manager and the Supervisor of Nuclear Fuel Cycle.

8.8.3 The Power Plant Manager may require special inventories to be conducted at any time.

8.8.4 Inventory records shall be retained per Section 8.10.

s

~ ~ ~

i SLA38 Page No.

30 of 35 Rev. No.

1 aw~--..t~m---y-sy-%f

.a.m-p-p,qyr,9.-.-,..m, -, -. -

c.-p..-

-rg,4 c--.g3

,-,n.=.m.9--=

gym-q+--i,.9-,w.,

.99

-~,.

.,,.r.,c

.wmgw+,e4-

~~

CPS No, 1898.00 8.9

. Nuclear Material Isotopic Calculations The process computer calculates and edits, for fuel accounting purposes, the raw isotopic composition of all-the fuel in the reactor.

This data may be periodically put in the FUELCOUNT data base ~.

The

' Current Inventory Status Report' (item 3.3.1 of FUELCOUNT) will then provide the data needed to complete DOE /NRC Form 742.

The DOE /NRC Form 742 shall be made as of March 31~and September 30 of each year and filed within thirty days after the end of the period covered by the report (10CFR70.53(a)(1)).

NOTE A DOE /NRC Form 742 does not need to be completed until such time that CPS is authorized to possess at any one time and location, SNM in a quantity totaling more than 350 grams of contained uranium-235, uranium-233, plutonium, or any combination thereof.

8.10 Records and Reports The.SNM records are. Quality Assurance Records and will have lifetime retention covered by PLANT RECORDS PREPARATION AND RETENTION, CPS No. 1017.01, and TECHNICAL RECORDS, CPS No. 1317.01.

Data for the

(.

Central File from FUACS should be obtained on microfiche until a tape can be archived (not applicable for FACCTAS).

8.10.1 Receipt Records:

This section should contain copies of NUCLEAR MATERIAL TRANSACTION REPORTS (DOE /NRC Form 741) and other forms associated with the receipt of new fuel.

8.10.2 Completed SNM TRANSFER CHECKLIST, CPS No.

1898.00C001 and completed FACCTAS sheets.

8.10.3 Shipping Records:

This section shall contain copies of NUCLEAR MATERIAL TRANSACTION REPORTS (DOE /NRC Form 741) listing Clinton Power Station as shipper.

It wilt also include copies of associated plant shipping lists sent with each shipment.

8.10.4 MATERIAL STATUS REPORT (DOE /NRC Form 742).

i.

l' 4

l SLA38 Page No.

31 of 35 e

Rev. No.

1

o

~

CPS No. 1898.00 8.10.5 Inventory Reports.

8.10.6 ICA Location / Component Lists from FUELCOUNT.

8.10.7 Fuel Assembly Isotopic data and exposure data (not required for exempt items).

8.10.8 Fuel Histories from FUELCOUNT.

8.11 System Review and Audit Procedures 8.11.1 Reviews and audits of material control and accounting grocedures and practices and audits of the SNM program shall be conducted by IPC QA/QC.

8.11.2-The Supervisor of Nuclear Fuel Cycle may perform an internal audit of the accountability program at any time.

8.12 Theft.' Unaccounted for, or Diversion of Special Nuclear Material 8.12.l_

If a theft, diversion (or attempted suspected diversion), or loss of SNM is discovered or suspected, or if SNM is

[

unaccounted for, notify the Power Plant A

Manager, the SNM Custodian, the Supervisor

- Radiation Protection, and the Supervisor

- Plant Protection.

8.12.2 Action should be taken to prevent further theft or diversion of SNM and to locate and recover the missing SNM.

The assistance of Suaervisor - Plant Protection and the Supervisor - Radiation Protection should be obtained, if necessary.

n SLA38 Page No.

32 of 35 Rev No.

1

_=

e-

[. ).#

CPS No. 1898.00 s

w 8.12.3 After a theft, diversion (or attempted

' (L L

or suspected diversion), or loss has been r\\

reported or verified, the Power Plant Manager should notify the Vice President.

The Power Plant Manager shall also immediately notify the NRC Region-III, Office of Inspection and Enforcement,'in' Glen Ellyn, Illinois, by telephone (312)-

790-5500, telegram, or telety>e, for any incident in which an attempt 1as been made or is believed to have been made to commit a theft or unlawful diversion of SNM, or-if SNM is lost.

A CPS CONDITION REPORT shall be initiated-(10CFR70.52) at this time to begin a trace investigation if SNM-is lost in shipment.

8.12.4 The SNM Custodian shall conduct a1 o

follow-up investigation and file a written

o report setting forth the details of the incident within a period of fifteen days of the initial report to the NRC Region-III office.

8.13 Transfer of Inventory Responsibility The SNM Custodian may transfer the accountability of

(

exempt quantities of SNM contained in sources to the

(

Supervisor - Radiation Protection.

Accountability shall then be per CPS No. 1924.03, RADI0 ACTIVE SOURCE CONTROL, LEAK TESTING, AND ACCOUNTABILITY.

t' 9.0 ACCEPTANCE CRITERIA None i

10.0 FINAL' CONDITIONS None

11.0 REFERENCES

11.1 ANSI N 15.8-1974, Nuclear Material Control Systems for Power Plants 11.2 Reg. Guide 5.26, 4/75, Selection of Material Balance Areas and Item Control Areas j,.

t

r SLA38 Page No.

33 of 35

!!lt Rev. No.

1

r CPS No. 1898.00 11.3 Reg. Guide 5.29, 6/75, Nuclear Material Control Systems for Nuclear Power Plants 11.4 American National Standard for Industrial Security for Nuclear Po<wer Plants N 18.17-1973 11.5.

ANSI N 45.2.3-1973, Housekeeping During the Construction Phase of Nuclear Power Plants 11.6 Code of Federal Regulations, Title 10, Parts 70, 71' and 73 11.7 Code of Federal Regulations, Title 49, part 173 11.8 NUREG BR-0006:' Instructions for Completing Nuclear Material Transaction Reports: Form DOE /NRC 741 11.9 Instructions to Licenses for the Preparation and Distribution of Form DOE /NRC 742 - Material Status Report 11.10 Fuel. Assembly and Component, Handling, Shipping and Storage Criteria, GE Design Specification 22A4478 11.11 FSAR Section 9.1.4.2.1, 9.1.1.3.2 11.12 FSAR Section 15.7.5.2

(

11.13 FUACS-B6, Training Course Material 11.14 FUELCOUNT-B6, An Interactive Fuel Accountability Data Storage'and Retrieval System, User's Manual and Programmers Guide 11.15 FUELCHECK-B6, FUACS File Verification Utility Program, User's Manual and Programmer's Guide 11.16 FUELMOVE-B6, Fuel Accountability Sof tware Movement Instruction Processor, User's Manual and Programmer's Guide 11.17 CNP 5.03, PROCUREMENT, CONTkOL, AND HANDLING OF RADIOACTIVE MATERIAL 11.18 CPS No. 1013.02, FUEL HANDLING

~ ' ~ "

11.19 CPS No. 1016.01, CPS CONDITION REPORTS 11.20 CPS No. 1017.01, PLANT RECORD PREPARATION, TRANSMITTAL, AND RETENTION l:

?,

k.

SLA38 Page No.

34 of 35 Rev. No.

1 L

CPS No. 1898.00

.e 11.21 CPS No. 1019.02, SYSTEM CLEANLINESS 11.22 CPS No. 1024.03, STATION RADIOLOGICAL AREAS, ACCESS CONTROL AND DESIGNATIONS 11.23 CPS No. 1131.02, EMPLOYEE SCREENING 11.24 CPS No. 1317.01, TECHNICAL RECORDS 11.25 CPS No. 1513.01, HANDLING, STORAGE, AND SHIPPING 11.26 CPS No. 1907.01', RECEIPT OF RADIOACTIVE MATERIAL 11.27 CPS No. 1913.00, RADIOACTIVE MATERIALS SHIPPING MANUAL

,11.28 CPS No. 1924.03, RADIOACTIVE SOURCE CONTROL, LEAK TESTING AND ACCOUNTABILITY 11.29 CPS No. 2209.01, CORE VERIFICATION 11.30 CPS No. 3703.01, REFUELING OPERATIONS 11.31 CPS No. 3703.02, FUEL HANDLING PLATFORM OPERATIONS 11.32 CPS No. 6001.01, SAMPLING AND ANALYSIS REQUIREMENTS 12.0 APPENDICES

(

None 13.0 DOCUMENTS CPS No. 1898.00C001, SNM TRANSFER CHECKLIST.

(

SLA38 Page No.

35 of 35 Rev. No.

1

..... }

....