MONTHYEARML20135H8071985-04-12012 April 1985 Procedure CP.104 Re Transient Occurrence That Leaves RCS Being Cooled by HPI Cooling Project stage: Other ML20135H8001985-04-12012 April 1985 Procedure CP.102 Re Normal Cooldown Project stage: Other ML20127D9261985-05-10010 May 1985 Requests Fee Re 850412 Application for Permanent Exemption from Installation of Reactor Vessel Head Vent Project stage: Approval ML20135H8091985-05-29029 May 1985 Rev 1 to Procedure CP.105 Re Transient Termination Following Occurrence That May Require Pressurizer Recovery Solid Plant Cooldown w/once-through Steam Generator Removing Heat & RCS Subcooled Project stage: Other ML20135H8031985-05-29029 May 1985 Rev 1 to Procedure CP.103 Re Transient Termination Following Occurrence That Leaves RCS Saturated w/once-through Steam Generators Removing Heat Project stage: Other ML20135H7971985-05-29029 May 1985 Rev 1 to Procedure E.07 Re Operator Action Project stage: Other ML20126K2251985-06-17017 June 1985 Submits Fee for 850412 Exemption Request Re Vessel Head Vents (10CFR50.44(c)(3)iii),per 850510 Request Project stage: Other ML20135H8121985-08-12012 August 1985 Rev 33 to Procedure B.4 Re Plant Shutdown & Cooldown Project stage: Other ML20135H7931985-09-19019 September 1985 Forwards Operating Procedures,Per Miner Request,To Aid in NRC Review of 850412 Request for Permanent Exemption from Requirements of 10CFR50.44(c) Re Installation of Reactor Vessel Head Vent Project stage: Request ML20138K6991985-12-11011 December 1985 Environ Assessment & Finding of No Significant Impact Re Util 850412 Application for Exemption from 10CFR50.44(c)(3)(iii) Requirements Re Installation of Reactor Vessel Head Vent Project stage: Approval ML20138K6751985-12-11011 December 1985 Forwards Environ Assessment & Finding of No Significant Impact,Re Util 850412 Application for Exemption from 10CFR50.44(c)(3)(iii) Requirements.Notice Forwarded for Fr Publication Project stage: Approval ML20137B5421985-12-24024 December 1985 Safety Evaluation Supporting 850412 Exemption Request from Reactor Vessel Head Vent Requirement of 10CFR50.44(c)(3) (III) Project stage: Approval ML20137B5311985-12-24024 December 1985 Exemption from Requirements of 10CFR50.44(c)(3)(iii) Re Installation of Reactor Vessel Head Vent & Other Sys Required to Maintain Adequate Core Cooling If Accumulation of Noncondensible Gases Causes Loss of Function of Sys Project stage: Approval ML20137B5151985-12-24024 December 1985 Forwards Exemption from Requirements of 10CFR50.44(c)(3) (Iii),Re Installation of Reactor Vessel Head Vent Based on Verification That Noncondensible Gas Bubble Can Be Safely Removed Via Hot Leg High Point Vents,Per 850412 Request Project stage: Approval 1985-05-10
[Table View] |
Text
-
a
- esuun SACRAMENTO MUNICIPAL UTILITY DISTRICT O 6201 S Street, P.O. Box 15830, Sacramento, CA 95813; (916) 452 3211 RJR 85-262 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA June, 1985 0FFICE OF ADHINISTRATION LICENSE FEE MANAGEMENT BRANCH ATIN REBA M DIGGS FACILITIES PROGRAM COORDINATOR U S NUCLEAR REGULATORY COMMISSION WASHINGTON DC 20555 DOCKET 50-312 RANCHO SECO NUCLEAR GENERATING STATION UNIT NO. 1 EXEMPTION REQUEST - 10 CFR 50.44(c)(3)i11, VESSEL HEAD VENTS, FEES Your letter of May 10,_1.935 indicatad that an application fee of $150 is required for the District's exemption request dated April 12, 1985.
1 The District felt that this request was a follow-up to a previous request which resulted in a temporary exemption and that the fee had been previously paid.
Conversations with Mr. Sydney Miner have indicated that this will be treated as a separate request and that a separate fee is required.
Therefore, pursuant to 10 CFR 170, an application fee of $150 is enclosed for the District exemption request dated April 12, 1985.
\\ kh a
a R. J. Rodrig z 4
Assistant Gen al Manager, Ac-o Nuclear h
h
M N
ENC e
s 7
E D
9 m
A p p lic an t.. - - -...... - - - - - - - -... -.. ;
C h e c k f.' o. - - - -
. j /./30- - - - -
Amount- -.
-. k /-
O.
Dato cf C' Date Check Rec'd. - b Received By......
8506190198 850617 v
PDR ADOCK 05000312 0'0 P
PDR I
O
-