ML20126B196

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 70-0036/92-05 on 921116-20.Violations Noted,But Not Cited
ML20126B196
Person / Time
Site: 07000036
Issue date: 12/09/1992
From: Wiedeman D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Rode J
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
Shared Package
ML20126B198 List:
References
NUDOCS 9212220006
Download: ML20126B196 (2)


Text

.-

(\\% f k6 l

DEC 0 91992 Combustion Engineering, Inc.

License No. SNM-33 ATIN:

James A. Rode Docket No. 70-0036/92005 Plant Manager P. O. Box 107, Highway P Hematite, MO 63047

Dear Mr. Rode:

This refers to the routine unannounced inspection conducted by Mr. George M.

France, III of this office on November 16-20, 1992, of activities authorized by NRC Special Nuclear Material License No. SNM-33, and to the discussion of our findings with you and your staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined during the inspection.

Within these areas, the inspection consisted of a selective examinat;on of procedures and representative recordt, observations, and interviews with personnel.

During this inspection, certain of your activities appeared to be in violation of NRC requirements. However, as described in the enclosed inspection report, the violations were categorized at Severity Level V and are not being cited because the criteria specified in Section VII.B.1 of the " General Statement of Policy and Procedures for NRC Enforcement Actions," (Enforcement Policy, 10 CFR Part 2, Appendix C (1992), were satisfied.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC Public Document Room.

We will gladly discuss any questions you have concerning this inspection.

Sincer,p.

/

g-..__

~

D. G. Wiedeman, Acting Chief Fuel Facilities and Contaminated Sites Section

Enclosure:

Inspection Report No. 70-0036/92005 See Attached Distribution RIII RIII-Gr#iiin o [p France /sd Cani

/N'M

'f[f4

/

9212220006 921209 PDR ADOCK 07000036 C

PDR l

fc 01

!l/

13 :

DEC 0 91992_

Combustion _ Engineering Inc.

2 Distribution cc w/ enclosure:

Jeremiah W. (Jay) Nixon,.

Missouri State Senator Dr. R. S. Siudek, President, ABB CE Nuclear Fuel Mr. S. B. Junkrans, Vice President, Manufacturing Operations Mr. A. E. Scherer, Vice President, Regulatory Affairs Mr. L. Grossman, Director, Manufacturing Technology, Nuclear Fuel Combustion Engineering, Inc.

Mr. C. B._Brinkman, Manager, Washington Nuclear Operations Mr. J. F. Conant, Manager, Nuclear Materials Licensing Mr. H. E. Eskridge, Manager,- Nuclear Licensing, Safety and Accountability M. Tokar, NMSS/IMSB DCD/DCB (RIDS)